Measure wind speed as an anemometer
•
Measure light intensity as a Lux meter
•
LCD display
•
ARC compatibility
•
Micro-B USB Charging Port
•
Solar Charge Panel
•
Built-in Lithium Ion battery
•
Water proof
AUTOMATE™
Solar Powered Wind & Sun Sensor
AUTOMATE™ | Solar Powered Wind & Sun Sensor is a device for measuring wind speed
and light intensity. The information is transmitted to ARC outdoor motorized shades that
will move to their top or bottom limits.
MT02-0301-072001_PRGM_v2.2 NOVEMBER 2019
all-guides
com
2 | Automate™ Programming Instructions | MT02-0301-072001
ROLLEASE ACMEDA
1
STATIC TITLE
SAFETY INSTRUCTIONS
WARNING: Important safety instructions to be read before installation and use.
Incorrect installation or use can lead to serious injury and will void manufacturer’s liability and warranty.
It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference.
Statement Regarding FCC Compliance
This device complies with Part 15 of the FCC Rules / Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et
Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes :
1. L’appareil ne doit pas produire de brouillage; 2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Do not dispose of in general waste.
Please recycle batteries and damaged electrical products appropriately.
•
Do not submerge in water or expose to extreme
temperatures.
•
Persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience
and knowledge should not be allowed to use this
product.
•
Use or modification outside the scope of this
instruction manual will void warranty.
•
Installation and programming to be performed by a
suitably qualified installer.
•
Follow installation instructions.
•
For use with motorized shading devices.
•
Keep away from children.
•
Frequently inspect for improper operation. Do not use
if repair or adjustment is necessary.
•
Keep clear when in operation.
•
Replace battery with correctly specified type.
Rollease Acmeda declares this equipment is in compliance
with the essential requirements and other relevant
provisions of R&TTE Directive 2014/53/EU
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
Any changes or modifications not expressly approved by
the party responsible for compliance could void the user’s
authority to operate the equipment.
Automate™ Programming Instructions | MT02-0301-072001 | 3
1
STATIC TITLE
TECHNICAL DATA / KIT CONTENTS
KIT COMPONENTS
Technical Specifications
Wind speed range
0-180 km/h [0-112mph]
Light intensity range
0-100 kLux
Frequency
433.92 MHz
Modulation
FSK
Transmitting power
<8dBm
Transmission distance
35 meters indoors, 200 meters open space
115 ft indoors, 656 ft in open space
Ambient operating temperature
-20 0C - +60 0C
-4 0F - +140 0F
Battery capacity
220 mAh
Charging current
67 mA by solar energy; 250 mA by USB
Standby electric current consumption
10 uA
Ingress protection
IP54
Pack Contents:
1 x Solar Powered Wind & Sun Sensor
2 x Screws
2 x Screw Wall Plug
Compatible Motors
MT01-1145-050001 - AUTOMATE | ARC FT Motor [AU]
MT01-1145-069002 - AUTOMATE | ARC FT SLIM Motor Quiet [US]
MT01-1145-069003 - AUTOMATE | ARC FT SLIM Motor [US]
MT01-1145-069004 - AUTOMATE | ARC FT SLIM Motor Quiet - 20’ Cord [US]
4 | Automate™ Programming Instructions | MT02-0301-072001
ROLLEASE ACMEDA
1
STATIC TITLE
CONTENTS
1
INSTALLATION
5
2
FUNCTIONAL OVERVIEW
6
2.1 Components
6
2.2 LCD Display
9
2.3 Measure wind speed & light intensity
10
2.4 Display the pre-set threshold value
10
2.5 Change the threshold value
11
2.6 Pair or unpair the sensor to a motor using a pre-paired remote
11
3
WIND & LIGHT CONTROL
13
3.1 Disable or enable the detection of wind and light
13
3.2 Wind speed control
13
3.3 Light control
14
4
TROUBLE SHOOTING
15
Automate™ Programming Instructions | MT02-0301-072001 | 5
1
STATIC TITLE
1.
Find an appropriate location outdoors
2.
Remove the base covers
3.
The solar panel must be face up and in direct sunlight
4.
Fix the sensor to a suitable surface
5.
Re-attach the base covers
6.
Ensure the three rotating cups are in an approximately horizontal position
1
INSTALLATION
6 | Automate™ Programming Instructions | MT02-0301-072001
ROLLEASE ACMEDA
1
STATIC TITLE
2.1
Components
Anemometer cup
Display
Menu
Up
Adjust
P2
USB Port Cover
Micro-B USB port
Factory Setting Button
Luminosity Sensor
Solar Panel
2
FUNCTIONAL OVERVIEW
all-guides
com
Automate™ Programming Instructions | MT02-0301-072001 | 7
NOTES:
1.
Anemometer cups: mounted at one end of the three horizontal arms at equal angles to each other on
a vertical shaft. The air flow past the cups in any horizontal direction turns the cups in a manner that is
proportional to the wind speed. The wind speed is measured in real-time by counting the turns of the
cups over a set time period.
2.
Luminosity Sensor: luminance in Lux is measured by a photo-diode and digitized using an empirical
formula to approximate the human eye response. The ambient light intensity is measured once every 16
seconds.
3.
Solar Panel: convert the sun light energy into electric energy to charge the internal battery.
4.
Menu button: loop displays or change the the threshold of wind speed and light intensity.
5.
Adjust button:
•
Loop displays of the values of wind speed and light intensity.
•
Press the Adjust key to subtract 1 from the present threshold value in its adjust mode.
•
Press and hold Adjust key to continuously decrease the threshold value in its adjust mode.
6.
UP Button:
•
Trigger the paired motor to move upward.
•
Press the UP button to add 1 to the present threshold value in its adjust mode.
•
Press and hold the UP button to continuously increase the threshold value in its adjust mode.
7.
P2 button: used to pair the sensor to a motor.
8.
Factory Setting button:
•
Reset the sensor to the factory default setting: Holding down the Menu button and pressing the
Factory Reset Button makes the sensor enter the low power factory setting. After the LCD becomes
blank, the factory default values have been reloaded to the memory as the pre-set threshold values.
Pressing the Factory Setting Button and releasing again returns the sensor to the normal status.
•
Default Factory Settings: Light alarm value is 10kLux, wind speed value is 10km/h [6mph].
•
Display all symbols on the LCD display.
8 | Automate™ Programming Instructions | MT02-0301-072001
ROLLEASE ACMEDA
2.1
COMPONENTS CONTINUED
•
Can be used to charge the internal battery.
•
The Micro-B port should always be covered during the outdoor usage to maintain a waterproof seal.
OPTIONAL:
USB Cable: MTPS-USBCABLE-6
Automate™ Programming Instructions | MT02-0301-072001 | 9
1.
While the power is on, the LCD displays all marks and the sensor monitors the command from the USB
port for 3 seconds. After that, the sensor enters the normal working state.
2.
The LCD screen lighting stays active for 1 minute. If there is no operation, the sensor automatically
switches its screen off for energy saving, but the program will keep running for normal detection and
command transmissions. When the screen is off, pressing any (non-reset) button triggers the screen to
be on again for another minute.
3.
Sun icon: indicates the light intensity detection mode.
4.
Flag icon: indicates the wind speed detection mode.
5.
Battery icon: The voltage of the internal battery is checked by its inner program once every day. The
appearance of this battery icon indicates that its voltage is below 3.0V.
6.
RF signal icon: displayed when transmitting a signal.
2.2
LCD Display
WIND
LIGHT
433MHz RF
SIGNAL
BATTERY
LOOP
VALUE
WIND SPEED
UNIT
LIGHT UNIT
10 | Automate™ Programming Instructions | MT02-0301-072001
ROLLEASE ACMEDA
In the sleep mode (blank screen), pressing the Adjust key can loop through light intensity or wind speed. When
the loop icon, , is present, the system will automatically display them in a cycle (5 seconds). The sequence
is light > wind > loop (light).
Press the MENU button repeatedly to display the pre-set threshold values in a cycle, the corresponding icon,
, flashes to indicate that the pre-setting value is displayed. Pressing the MENU key again returns
to the normal mode. The sequence is: display the light intensity threshold value > display the wind speed
threshold value > return to normal mode.
2.3
Measure wind speed & light intensity
2.4
Display the pre-set threshold value
Press ADJUST button
Press MENU button
Press ADJUST button
Press MENU button
Automate™ Programming Instructions | MT02-0301-072001 | 11
1.
Press and hold the Menu button for 2 seconds to enter the setting mode, then press the Menu key to
toggle the setting sequence: Set the light threshold value > Set the wind speed threshold value > Exit the
setting state.
The flash of the setting number displayed on the screen indicates the setting mode. In this mode, the threshold
values can be increased by pressing the UP button and decreased by pressing the Adjust button.
After 10 seconds without input, the sensor automatically returns to normal display mode. When settings are
completed, the values, including light alarm values and wind speed alarm values are automatically save to the
EEPROM. Resetting the sensor or powering down does not change those pre-set values.
1.
Pair the motor to a remote
NOTE:
•
The sensor can only work well when the motor was configured with the upper and bottom limits.
•
The pair relationship is kept even if the motor power is reset or the sensor is reset to its default setting.
2.5
Change the threshold value
2.6
Pair or unpair the sensor to a motor using a pre-paired remote
Approx.
Motor Response
Motor Response
Hold P1 button on
motor head.
Hold STOP on
controller to add or
remove.
US FT
motor head
AU FT
motor head
all-guides
com
12 | Automate™ Programming Instructions | MT02-0301-072001
ROLLEASE ACMEDA
1.
Pair the motor to a remote
2.
Pair or unpair a motor to the sensor using a pre-paired remote
2.6
Pair or unpair the sensor to a motor using a pre-paired remote continued
Press P2 on
controller.
Press P2 on
controller.
Press P2 on the
sensor to add or
remove it.
Press P2 to wake
the sensor as
required.
Motor Response
Motor Response
Motor Response
NOTE:
•
The motor function should be turned on to detect wind and light before the sensor can initialize the motor
movement.
•
If the pair is successfully done, the motor can be triggered to move upward by pressing the UP button on
the sensor.
•
After the sensor is paired to a motor, it can independently drive the motor without the remote.
•
Ensure the wind and light sensor functionality on the motor is enabled prior to pairing the wind and sun
sensor.
Automate™ Programming Instructions | MT02-0301-072001 | 13
1
STATIC TITLE
3.1
Disable or enable the detection of wind and light
•
The wind speed control function can be disabled by setting its threshold to ZERO. Other threshold values
enable this function.
•
The light intensity function can be disabled by setting its threshold to ZERO. Other threshold values
enable this function.
1.
Pair the motor with a controller
2.
Once paired to the motor:
3.
Repeating this function disables the wind and sun sensor functionality:
Press P2 on
controller.
Press P2 on
controller.
Press UP on
controller.
Press UP on
controller.
Press STOP on
controller.
Press STOP on
controller.
Motor Response
Motor Response
Motor Response
Motor Response
Motor Response
Motor Response
3
WIND & LIGHT CONTROL
3.2
Wind speed control
When the wind speed continuously exceeds the threshold value of wind speed (for longer than 3 seconds),
the sensor command is executed to control the motor “UP” action. If the wind speed continously exceeds the
threshold, the sensor sends the “UP” command every 1 minute until 14 times.To prevent the motorized shades
from frequently opening and closing under a gust, the motor does not operate for next 8 minutes.
14 | Automate™ Programming Instructions | MT02-0301-072001
ROLLEASE ACMEDA
3.3
Light control
•
If the light control function is turned on, the sensor sends a command to trigger the motor to move
DOWN when the environmental light intensity is higher than the threshold. After this period, the sensor
temporarily disables its light detection for the next 15 minutes.
•
If the light control function is on, the sensor drives the motor UP when the light intensity continues to be
less than the set value for 15 minutes.
•
Wind sensor trigger overrides light sensor, and moves motor up into top limit or tension, despite motor
having moved down due to strong light.
Factory default threshold:
•
wind speed=10km/h
•
light intensity=10klux
Light Definitions:
High >10klux
Moderate <10klux
NOTE:
1.
After the sensor is powered on and a motor is paired to it, the sensor transmits an “UP” command
immediately if the environmental wind speed is detected to be faster than the threshold. After 10 seconds,
the sensor repeats the signal transmission ONCE. Its wind detection is disabled for another 3 minutes
and the light control function is suspended for 15 minutes. Manual operation of pressing the “UP” and
“SET” keys does not re-send the command transmission.
2.
If the sensor detects strong light and wind, it transmits one command at least 5 times. Before its
environment changes, the sensor suspends the signal transmission but still operates its normal
functions such as the detection of light, wind and LCD functions.
Summary
Mostly
Sunny
Mostly
Sunny
Mostly
Sunny
Mostly
Sunny
Temp.
Max
°C
26
27
31
28
°F
79
81
88
82
Temp.
Min
°C
14
14
16
17
°F
58
58
61
63
Light Intensity
High
High
High
Moderate
Wind
Speed
km/h
3
12
4
12
2
10
9
13
mp/h
2
8
3
8
1
6
6
8
Motor Direction
STOP
UP
DOWN
Factory default threshold: wind speed=10km/h light intensity=10klux
Define: High>10Klux, Moderate<=10klux
Summary
Temperature
Light intensity
Rainfall
Wind speed
Motor direction
Move Down
Move up
NO action
Factory default threshold: wind speed=10km/h light intensity=10klux
Define: High>10Klux, Moderate<=10klux
Summary
Temperature
Light intensity
Rainfall
Wind speed
Motor direction
Move Down
Move up
NO action
Factory default threshold: wind speed=10km/h light intensity=10klux
Define: High>10Klux, Moderate<=10klux
Summary
Temperature
Light intensity
Rainfall
Wind speed
Motor direction
Move Down
Move up
NO action
Factory default threshold: wind speed=10km/h light intensity=10klux
Define: High>10Klux, Moderate<=10
Summary
Temperature
Light intensity
Rainfall
Wind speed
Motor direction
Move Down
Move up
NO action
Automate™ Programming Instructions | MT02-0301-072001 | 15
1
STATIC TITLE
4
TROUBLE SHOOTING
Problem
Cause
Remedy
Motor is not responding
Sensor battery is discharged
Recharge battery with a USB cable
Radio interference/Shielding
Ensure transmitter is positioned
away from metal objects and that
the motor aerial/receiver is kept
straight and away from metal
Receiver distance is too far from
transmitter
Move transmitter to a closer
position
Power failure
Check the connection from power
supply to motor
Incorrect wiring
Check if wiring is connected
correctly
Pairing error
Press UP button on sensor to verify
pairing
The motor’s function of detecting
wind/light is off
Turn on the function
Motor extends then constantly
retracts unexpectedly
Wind or light threshold is too low
Increase the threshold to reduce
sensitivity
Extend motorized shade is
casting shadow onto sensor
Check & reposition sensor if
necessary
Motor does not react to wind or
light setting
Wind sensitivity is too high or too
low
Adjust sensitivity
Time interval of strong wind is
less than 3 minutes
The wind triggering time length
must be over 3 minutes
Time interval of light is less than
15 minutes
The light triggering time length
must be over 15 minutes
ROLLEASE ACMEDA | AUSTRALIA
110 Northcorp Boulevard,
Broadmeadows VIC 3047
T +61 3 9355 0100 | F +61 3 9355 0110
ROLLEASE ACMEDA | USA
750 East Main Street, 7th Floor
Stamford, CT 06902
T +1 00 552 5100 | F +1 203 64 0513
ROLLEASE ACMEDA | EUROPE
Via Conca Del Naviglio 18, Milan
(Lombardia) Italy
T +39 02 8982 7317 | F +39 02 8982 7317
[email protected]
rolleaseacmeda.com