Sensit ULTRA-TRAC APL Quick Start Instructions

Specifications

Brand: Sensit
Category: Measuring Instruments
Model: ULTRA-TRAC APL (Quick Start Instructions)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Sensit ULTRA-TRAC APL Quick Start Instructions online using the built-in PDF viewer.

Text of the manual

Prepare the area by creating a grid pattern

prior to testing. Perform all Scans on like-surfaced areas such as asphalt, concrete, rock, grass. Always perform multiple scans. Do not test on expansion joints or cracks in the surface. Hold the APL as straight up as possible. TERMS: Slice – individual test point Scan – A series of slices along a single line Pipe Map – the results of a single scan CAUTION: Consult instruction manual for product specifications regarding pipe detection limits. The APL may detect subsurface voids that are not pipe systems. This is not a substitute for the instruction manual. It is for reference only. Read and understand the instruction manual before use. MADE IN USA Distributed by: 851 Transport Drive Valparaiso, IN 46383-8432 Phone: 219 465 2700 Web: www.gasleaksensors.com Innovative Detection Solutions

Press and hold the power button until

the display illuminates. Display will remain blank for 10-15 seconds during start up prior to displaying Sensit logo followed by “Select a depth”. 2. Place measuring device in desired test area. For best results limit the test length (scan) to 10ft. 3. Using the A or C button select test depth. Deep is greater than 10ft. Normal is up to 10ft. 4. Using the A or C button select a scan direction. Step to Left or Step to Right. 5. Using the A or C button select a step distance. 6 or 12 inches. For softer surfaces and/or shallow depths us 6 inch distances. 6. Place instrument on ground adjacent to the first mark on your measuring device. 7. Place foot on footpad. 8. Push the handle firmly forward. 9. Press and release the large black scan button at the top of the handle (just below the control box). 10. Move to the next test location (slice) adjacent to the next 6 or 12 inch mark on the measuring device. 11. Repeat steps 7-10 until scan distance has been completed. 12. Press the C button to review the “Pipe Map”. 13. Mark the locations on the ground adjacent to the measuring device as shown on the APL. 14. Move measuring device forward or backward 6-10 ft away from current location. Repeat steps 6-13. 15. Repeat scan process as needed to mark location. 16. Review marks to determine direction of pipe. 17. To turn off hold the power button until the display turns off (after 5 beeps). ULTRA-TRAC® APL QUICK-START INSTRUCTIONS

Other Measuring Instruments Manuals