Sensit ULTRA-TRAC APL Quick Start Instructions
Read Online
Read the Sensit ULTRA-TRAC APL Quick Start Instructions online using the built-in PDF viewer.
Text of the manual
Prepare the area by creating a grid pattern
prior to testing.
Perform all Scans on like-surfaced areas
such as asphalt, concrete, rock, grass.
Always perform multiple scans.
Do not test on expansion joints or cracks in
the surface.
Hold the APL as straight up as possible.
TERMS:
Slice – individual test point
Scan – A series of slices along a single line
Pipe Map – the results of a single scan
CAUTION:
Consult instruction manual for product
specifications regarding pipe detection
limits.
The APL may detect subsurface voids that
are not pipe systems.
This is not a substitute for the
instruction manual. It is for
reference only.
Read and understand the
instruction manual before use.
MADE IN USA
Distributed by:
851 Transport Drive
Valparaiso, IN 46383-8432
Phone: 219 465 2700
Web: www.gasleaksensors.com
Innovative Detection Solutions
Press and hold the power button until
the display illuminates. Display will remain
blank for 10-15 seconds during start up
prior to displaying Sensit logo followed by
“Select a depth”.
2.
Place measuring device in desired test
area. For best results limit the test length
(scan) to 10ft.
3.
Using the A or C button select test
depth. Deep is greater than 10ft. Normal
is up to 10ft.
4.
Using the A or C button select a scan
direction. Step to Left or Step to Right.
5.
Using the A or C button select a step
distance. 6 or 12 inches. For softer surfaces
and/or shallow depths us 6 inch distances.
6.
Place instrument on ground adjacent
to the first mark on your measuring device.
7.
Place foot on footpad.
8.
Push the handle firmly forward.
9.
Press and release the large black scan
button at the top of the handle (just below
the control box).
10. Move to the next test location (slice)
adjacent to the next 6 or 12 inch mark on the
measuring device.
11. Repeat steps 7-10 until scan distance
has been completed.
12. Press the C button to review the “Pipe
Map”.
13. Mark the locations on the ground
adjacent to the measuring device as shown
on the APL.
14. Move measuring device forward or
backward 6-10 ft away from current location.
Repeat steps 6-13.
15. Repeat scan process as needed to
mark location.
16. Review marks to determine direction of
pipe.
17. To turn off hold the power button until
the display turns off (after 5 beeps).
ULTRA-TRAC® APL
QUICK-START INSTRUCTIONS