Via Austria, 26 – 35127 – PADOVA – ITALY

Tel. +39.049.8705355 - 8705359 - Fax +39.049.8706287 For manuals and configuration software, visit www.seneca.com/myboat MI004981-E INSTRUCTIONS IN ORIGINAL LANGUAGE ENGLISH - 1/7 EE INSTALLATION MANUAL MyBoat Real time remote control and alarm management device for boats This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The content of this document corresponds with the products and technologies described. Data herein may be modified or supplemented for technical and/or sales purposes.

Polycarbonate / ABS material.

LED SIGNALS ON THE FRONT PANEL LED STATUS LED MEANING GSM (Yellow) Off MyBoat off Medium flash (64 ms ON / 800 ms OFF)  Network search  No signal  SIM card with incorrect pin Slow flash (64 ms ON / 3000 ms OFF)  Registration to the GSM network successful Fast flash (64ms ON / 300 ms OFF)  Successful access to the Internet network  Correct APN  Registration to the GPRS network successful PWR (Green) On Off MyBoat on MyBoat off PRODUCT DESCRIPTION  MI004981-E ENGLISH - 2/7 80 mm 108 mm 32 mm 8 mm MyBoat is a flexible control system consisting of a smart control unit and wireless monitoring sensors for the remote control and alarm management in real time of yachts, boats and general and fleet. As well as managing the communication with the sensors and the SENECA cloud platform, the control unit is set for the advanced configuration and optional remote control of 4 digital inputs, 1 timed relay output (e.g. siren), 1 non-timed relay output (auxiliary), 1 analogue input for service battery sensor (already wired to the control unit power supply) and 1 fuel level analogue input. For information on the functions of your kit, refer to the summary table on the package.

SYMBOLS ON THE ENCLOSURE

PWR power button Slot for mini SIM GSM antenna Micro SD card slot Scroll display button (SCR) Micro USB connector TECHNICAL SPECIFICATIONS POWER SUPPLY Voltage absorption Internal battery (buffer) 6 – 15 V , 500 mA Max.  3.5 W Max. Lithium Ion 3.7 V - 1000 mAh, rechargeable.  ENVIRONMENTAL CONDITIONS Temperature Humidity Storage temperature Protection rating Seneca recommends use at 0 to 45 ° C for correct operation. With the power supply present: -20 .. + 55 °C. With use of the battery (when discharged): -20 .. + 45 ° C. Charging is possible in the range: 0 .. +45°C. 30% – 90%, non condensing. from -20 °C to +20 °C <1 year; from -20 °C to +45 °C <3 months; from -20 °C to +60 °C < 1 month IP20  MI004981-E ENGLISH- 3/7 SD SIM Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling programs). The symbol on the product or its packaging shows that the product must be disposed of at a collection centre authorised to recycle electrical and electronic waste. The full content of this manual must be read before operation. The device is to be exclusively used by qualified electricians. Damaged parts must be replaced by the manufacturer, who is also responsible for repairing the device. The product is sensitive to electrostatic discharges. Take appropriate measures during operation. The warranty shall become null and void in the event of improper use or tampering with the device or accessories supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this manual are not followed. For optimum reception of the GPS signal from satellites, it is best to place the MyBoat horizontally in an area not covered by metal structures. If this is not possible, an optional external antenna with 3m cable (code AGPS) is available. Follow the procedure supplied with the package for the installation of the external antenna.

BASIC CARD SPECIFICATIONS

DIGITAL INPUTS Type Maximum frequency Threshold OFF Threshold ON 4 inputs Reed, contact, PNP, Pulscap 30 Hz ANALOGUE INPUTS Accuracy type 2 inputs Voltage 0 - 30 V  / Current 0 - 20 mA 0.1% of the full scale VOLTAGE OUTPUT: +12 V  50 mA (maximum current) TEMPERATURE SENSOR NTC thermistor USB PORT 1 reserved micro USB port DISPLAY CONNECTIONS CPU ARM 100 Mhz 32 bit INTERNAL MEMORY FLASH 2 MByte (log) Micro SD slot Type/ Memory Push-Push for SD card and SD HC card / max 32GB SIM slot Type Push-Push for mini SIM (15 x 25 mm) MMCX CONNECTOR External GPS antenna connector (optional) GSM Quad band (850 / 900 / 1800 / 1900 MHz) GPS CARD SPECtIFICATIONS RECEIVER 22 channels SENSITIVITY -165 dBm FIX TIME 32 s usually ACCURACY up to 2.5 m RECEIVER AND SENSOR SPECIFICATIONS TECHNOLOGY LoRa ® FREQUENCY BANDS 863 ÷ 870 MHz SENSITIVITY up to -146 dBm RF POWER + 14 dBm RELAY EXPANSION CARD SPECIFICATIONS (OPTIONAL) REFERENCE STANDARDS  MI004981-E ENGLISH- 4/7 STANDARD ETSI EN 301 489-7 EN301 511 EN301 489-1 IEC / EN 60950 DIGITAL OUTPUTS 2 outputs Relay 3 A max - 250V SPST (with shared terminal) 0 - 3 V, I < 1 mA 6 - 24 V, I > 3 mA 128 x 32 LCD Dots with visible area of 39 mm x 8.6 mm Spring clamps, 3.5 mm pitch, connector for Micro USB and SMA connector for GSM Antenna

• ON/OFF BUTTON AND SCROLL DISPLAY BUTTON

• MICRO USB PORT AND POWER SUPPLY • AUTO SHUTOFF INSERTING THE SIM CARD AND SD CARD • INSERTING THE SIM CARD • INSERTING THE MICRO SD CARD  MI004981-E ENGLISH - 5/7 INITIAL POWERING ON OF THE DEVICE ANTENNA micro USB PWR SCR ANTENNA SIM card SD card MyBoat is supplied in "shipping mode". This mode avoids any unnecessary discharge of the battery during storage and shipping. When switched on for the first time, power the device with the power cord supplied; this allows "shipping mode" to be exited. MyBoat is equipped with a PWR button located on the top left side (front panel view). Pressing this button turns the module on and off. To switch it off, hold the PWR key down for a few seconds. MyBoat is also equipped with a SCR button, located on the top right side (front panel view). Pressing this key displays the parameters. The device has a micro USB connector on the left side of its enclosure, which can be used for configuration, firmware updates and to recharge the internal battery. To recharge the internal battery, use: - the power cord with cigarette lighter socket, equipped with a fuse connecting the cables to the + and- (GND) terminals. - a PC via the micro USB port with a standard cable. Power supply through the USB jack is not suitable for fixed installations, or configurations where relays and/or digital inputs are used. If the display indicates "LOW BAT", it means that the internal battery is almost empty: after 60 seconds from this indication, the device switches off automatically. To restore the battery charge to an appropriate value, power the device using one of the recommended modes. MyBoat has an entry for mini SIM located in the right side of the enclosure. To insert the card in its corresponding slot, make sure the metal contacts are facing right (as seen in the figure). MyBoat is equipped with an SD card input that can be used to update the device's firmware and update the information and connection parameters with the world's best known telephony operators. Note: DO NOT REMOVE THE CONTENT OF THE SD CARD PROVIDED. THIS MAY RESULT IN FAILED DATA CONNECTION WITH THE MYBOAT SERVICE. The input for micro SD card is located on the right side of the enclosure. To insert the SD card in its corresponding slot, make sure the metal contacts are facing right (as seen in the figure).

ENGLISH - 6/7

• INSERTION AND EXTRACTION FROM TERMINALS WITH A PUSH-WIRE Insertion o a rigid cable f Press down Recommended flaying: 8-9 mm Insertion o a flexible cable f A Press with screwdriver B Insert the cable Extraction of a cable A Press with a screwdriver B Extract the cable • PUSH-WIRE TERMINAL BLOCK (timed) AUX1 Shared of the two relays (not timed) AUX2 1 2 3 (normally closed) DIN4 AUX + 12 Vdc (service battery sensor) AIN 1 0 V= 0%; 10 V = 100% NTC 4 5 6 7 8 9 10 1 GND (Sensor input) NTC + Power - Power 12 13 + - 1 2 3 4 5 6 7 8 9 10 11 12 - + 13 MyBoat has a terminal block inside its enclosure. To access the internal terminal block of the device, unscrew the screw at the centre of the black cover positioned at the bottom of the enclosure and lift up. In the side figure, the cover has been removed. IMPORTANT: With the relay card, mobile wiring of cables connected to terminals is not permitted. To make the cables from the terminals safe, use the break-out passages in the back of the enclosure. When the wiring is complete, fasten the protective cover on the device with the screw to prevent any accidental contact. (normally closed) DIN3 (normally closed) DIN2 (normally closed) DIN1

External GPS antenna with 3 m cable

A-GPS A-GSM/QUAD-N CPS-TIP-MP MYBOAT-S1 MYBOAT-S2 MYBOAT-S3 MYBOAT-S4 MYBOAT-S5 MYBOAT-S6 MYBOAT-S7 MYBOAT-S8 External GSM / QUAND-N antenna with 5 m cable SPARE ACCESSORIES Spare cigarette lighter power supply Replacement sensor for access control Replacement sensor for bilge monitoring Replacement sensor for access control Replacement sensor for battery monitoring Replacement sensor for battery monitoring Replacement sensor for bilge monitoring Replacement sensor for access control Replacement sensor for access control CONTACTS Technical support [email protected] Product information [email protected]  MI004981-E ENGLISH - 7/7