INOR IPAQ-L User Instructions
Text of the manual
MEASURE OF SUCCESS
USER INSTRUCTIONS
www.inor.com, www.inor.se
The manual must be read prior to adjustment
and/or installation. All information subject to
change without notice.
86BIQ00006 2003-5
SWEDEN
GERMANY
USA
ADDRESS
1860 Renaissance Blvd.
Sturtevant, WI 53177, USA
PHONE
+1-262-884-4535
FAX
+1-262-884-4537
E-MAIL
[email protected]
ADDRESS
PO Box 9125
S-200 39 MALMÖ, Sweden
PHONE
+46-40-31 25 60
FAX
+46-40-31 25 70
E-MAIL
[email protected]
ADDRESS
Rodenbacher Chaussee 6
D-63457 Hanau-Wolfgang; Germany
PHONE
+49-6181-582940
FAX
+49-6181-582944
E-MAIL
[email protected]
FINLAND
ADDRESS
Unikkotie13
01300 VANTAA, Finland
PHONE
+358- 9-83850210
FAX
+358-9-83850219
E-MAIL
[email protected]
The transmitter is configured from a standard IBM compatible PC by
using the IPRO software version 3.07 or later. The latest version of
IPRO can be downloaded from http://www.inor.com. When the
transmitter is set from a PC no calibration is needed.
When calibrate/configure ”online” with the input
connected to hazardous area the ATEX certified version of
IPRO-X cable must be used.
The transmitter is polarity protected and will not be damaged by
connecting the power supply with the wrong polarity, but the out-
put will be 0 mA.
The maximum load in the output loop depends on the supply
voltage,see ”DATA shortform”
”Isolation input/output/PC” mentioned in the data sheet,
indicates signal isolation only. It shall not be interpreted as
an IS galvanic isolation like an isolating barrier. Therefore
ordinary care in selecting barrier and grounding should be
considered for the IPAQ-LX.
Sensor wire check: the transmitter uses a pulsating technique to
monitor sensor break or sensor shortened to avoid measuring errors.
This pulsating signal may interfere with some electronic calibrators.
By selecting ”Sensor Break = None” in the IPRO software and
download the configuration into the transmitter the pulsating signal
is turned off.
GENERAL INFORMATION
INTRODUCTION
IPAQ-L is a universal and intelligent 2-wire rail-mounted transmitter
for temperature and other measurement applications.
IPAQ-LX is the Intrinsic Safe version for use in Ex-applications.
DIMENSIONS
Intelligent 2-wire
DIN Rail Temperature
Transmitter
CONFIGURATION
The IPAQ-L/LX transmitter must be powered, when you configure
the transmitter, (see ”Connections” fig.1). If IPRO (the IPAQ software)
isn’t installed in your PC, install the software.
For keeping the safety of the internal circuits in the
IPAQ-LX, always use Ex-power supply or a zener barrier with
limitations according to Ex-data and IPRO-X configuration
cable when making a configuration.
When choosing differential temperature measuments with Pt100 be
sure to select ”sensor break” = none.
Configuration from PC is ”on-line”, that is, the transmitter can be
configured while in operation if the area is known to be non-hazardous.
The output is frozen while transmission from PC to IPAQ take place.
When transfer is done the transmitter uses the new parameters.
ATEX
!
IPAQ-LX, isolated (ATEX)
70IPLX0001
IPAQ-LX, isolated (FM)
70IPLX1001
IPAQ-L, isolated, mA input
70IPL00003
Software and cable
IPRO-X (IPRO with cable)
70CFG00092
LIMITED WARRANTY
INOR Process AB, or any other affiliated company within the Inor Group (hereinafter
jointly referred to as ”Inor”), hereby warrants that the Product will be free from
defects in materials or workmanship for a period of five (5) years from the date of
delivery (”Limited Warranty”). This Limited Warranty is limited to repair or replacement
at Inor’s option and is effective only for the first end-user of the Product. Upon
receipt of a warranty claim, Inor shall respond within a reasonable time period as to
its decision concerning:
1Whether Inor acknowledges its responsibility for any asserted defect in
materials or workmanship; and, if so,
2the appropriate cause of action to be taken (i.e. whether a defective
product should be replaced or repaired by Inor).
This Limited Warranty applies only if the Product:
1is installed according to the instructions furnished by Inor;
2is connected to a proper power supply;
3is not misused or abused; and
4there is no evidence of tampering, mishandling, neglect, accidenta damage,
modification or repair without the approval of Inor or damage done to the
Product by anyone other than Inor.
This Limited Warranty is provided by Inor and contains the only express warranty
provided.
INOR SPECIFICALLY DISCLAIMS ANY EXPRESS WARRANTY NOT PROVIDED
HEREIN AND ANY IMPLIED WARRANTY, GUARANTEE OR REPRESENTA-
TION AS TO SUITABILITY FOR ANY PARTICULAR PURPOSE, PERFORMANCE,
QUALITY AND ABSENCE OF ANY HIDDEN DEFECTS, AND ANY REMEDY FOR
BREACH OF CONTRACT, WHICH BUT FOR THIS PROVISION, MIGHT ARISE
BY IMPLICATION, OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING IMPLIED WARRANTIES OF MER-CHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE. EXCEPT AS PROVIDED HEREIN,
INOR FURTHER DISCLAIMS ANY RESPONSIBILITY FOR LOSSES, EXPENSES,
INCONVENIENCES, SPECIAL, DIRECT, SECONDARY OR CONSEQUENTIAL
DAMAGES ARISING FROM OWNERSHIP OR USE OF THE PRODUCT.
Products that are covered by the Limited Warranty will either be repaired or replaced
at the option of Inor. Customer pays freight to Inor, and Inor will pay the return
freight by post or other “normal” way of transport. If any other type of return freight
is requested, customer pays the whole return cost.
DATA (shortform)
CONNECTIONS
ORDERING TABLE
IPAQ-LX EX-DATA
Approval Demko 03 ATEX 134461X
CE 0539
II (1)G
[EEx ia] IIC
Output (terminals 5-6)
(current loop)
Ui :
30 VDC
Ii :
100 mA
Pi :
0,9 W
Li :
0 mH
Ci :
1 nF
Input (terminal 1-2-3-4)
(Intrinsically safe sensor terminals)
Uo:
30 V
Io :
27 mA
Lo :
50 mH
Co:
52 nF
The equipment must be electrically connected (terminal 5 and 6) via a certified
isolating interface/zener barrier -and shall be placed outside the hazardous area.
IPAQ-L/LX are designed to fit on a standard DIN Rail.
IPAQ-LX must be installed in safe area.
Connect input, output and power supply acc. to fig. 1-9.
INSTALLATION
Power supply: IPAQ-L
7.5 to 36 VDC
IPAQ-LX
8 to 30 VDC
Isolation in/out:
1500 VAC
Output:
4-20 mA
Operating temperature:
-20 to +70 °C
T1
T2
mV
RTD
(Pt100)
T/C
RTD
100%
0%
RTD
RTD
(Pt100)
100%
0%
RTD
4-wire connection
Pt100
Diff temperature T1 > T2
Potentiometer
3-wire connection
Potentiometer
4-wire connection
Voltage
mV
Thermocouple
Supply voltage U (VDC)
RTD
3-wire connection
Fig 3
Fig 4
Fig 5
Fig 6
Fig 7
Fig 8
Fig 9
IPAQ-L
IPAQ-LX
!
!
Fig 1
Fig 2