iRest SL-D180 Operation Instructions Manual
Read Online
Read the iRest SL-D180 Operation Instructions Manual online using the built-in PDF viewer.
Text of the manual
Thanks for purchasing this product. Please read this manual instruction carefully in
order to know how to use this product correctly before operation. Please pay more
attention to some important safety warning and keep this manual book properly for
future use.
Note: Our Company reserves the right to revise the design and description of this
product without any further notice. Please refer to the actual color of this product.
CONTENTS
Safety and maintenance issues
Method and function of buttons
Product parts and methods of use
Cleaning and maintenance
Troubleshooting
Method of use
Product features
Safety and maintenance issues
Safety and maintenance issues
1.IMPORTANT SAFETY WARNING
Do not allow any foreign matter to enter the clearance between the massage head and the
casing
Do not allow the product to come into contact with water so as to avoid any possible
accidents that may result from a short circuit.
If the mains cable or plug is damaged, do not disassemble and attempt to repair it by yourself.
Please contact your distributor.
Ensure that the mains power is suitable for this product.
Please disconnect the product from the mains supply after use or before cleaning to avoid
damage to the equipment or personal injury.
Please use this product according to this Manual.
Do not use any spare parts and attachments other than those recommended.
Do not use this product if its casing or mains cable is damaged.
Do not use this product if you are under the influence of alcohol or feeling unwell.
Do not use this product with too much force so as to avoid injury.
Do not keep this product on for more than 15 minutes so as to avoid overheating.
Do not use this product within one hour of eating.
Please use this product carefully according to your doctor's advice if you have a neck or back
injury or if you have had an operation recently.
2.WORKING ENVIRONMENT
Do not use this product in a highly humid environment such as a bathroom.
Do not use this product immediately after there has been a sharp change in the
environmental temperature.
Do not use this product in an environment where there are lots of dust or corrosive gases.
Do not use this product when it is covered by a blanket or pillow, etc.
3.PEOPLE THAT SHOULD NOT USE THIS PRODUCT
People with contagious skin conditions
Patients with osteoporosis
Patients with heart diseases and with electronic medical instruments like a heart pacemaker
People in a high fever
Women that are pregnant or menstruating
Those who are injured or suffering from any body surface disease
The appliance has a heated surface. Persons insensitive to heat must be careful when using
the appliance.
Children under 14-year old or people mentally unbalanced without being Supervised are not
allowed to use this machine.
Those who to need rest according to a doctor's advice or those who do not feel well
Do not use this product when you are wet
Do not use this product on a pet.
4.SAFETY PRECAUTIONS
Do not plug or unplug this product when your hands are wet
Do not pull the cable when unplugging. Do not plug or unplug carelessly.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
Do not damage the cable or change the circuit of the product.
Please cease using this product in case of a power cut in order to avoid any body injury upon
sudden power resumption.
Please stop using this product and consult your local supplier if you notice anything abnormal
with the product during use.
Please stop using this product and consult your doctor for advice
encloser
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
The appliance has a heated surface. Persons insensitive to heat must be careful when using
the appliance.
Please do not pull controller connecting line, in cause that power cord fracture or plug with
bad contact. When pulling out power plug, Please Hold the plug pulled back, rather than
directly draw the power cord.
When the whole machine does not working, please immediately stop using it to pull out
power plug.
This product is prohibited in the following locations: Bathroom and kitchen high
temperature lights
damp
high voltage and the source of fire and water.
Far away from sharp objects, the machine can't be used when its
was
damaged.
Do not force it with fierce pressure or put body pressure on the massage mat. Don't
touch with hard objects; don't weigh or tread it.
Method and function of buttons
the new concept of kneading massage,match the human body engineering design
of the neck and the shoulder.
the massage head is specially designed according to the neck and shoulder to give
you the most comfortable experience.
U shaped,arm in arm design,strong or gentle type, strength is decided by ourselves.
clockwise and anti-clockwise kneading automatic conversion system.
kneading direction manually choose funciton.
warm function controll separately,promote the blood circulation effectively.
Switch operation is very simple.
PolyurethaneHigh-grade material holster
Using the safety of the overheating protection device
ON or OFF
Set the rated working time for 20 minutes
Start after 20 minutes automatically stop operation
can change the rotation direction in the start.
Can use in a particular place
massage in a specific direction.
Waist massage
Abdominal
massage
Leg massage
Foot massage
you can choose to stop heating function when it is working,
press onetime, stop heating function , press again,
heating function work again
Product parts and methods of use
Cleaning and maintenance
Troubleshooting
Input:100-240vac 50/60hz 1.6a
Output:dc 12v
Power
Method of use:(1)the power insert into the massage
(2)The power plug insert into the socket
car charger
Method of use
Car charger socket outlet ends respectively connected to the
massager and vehicle socket outlet.
1.after using products, must pull the plug, then cool to stay safe before you start cleaning
2.After using, please use wet cloth clean up dust and dirt on the product.
3.
4.Please do not use wet cloth clean control panel, lest cause failure, can only use dry
cloth to wipe the control panel
5.
Please do not use corrosive cleaner, such as benzene or thinner to clean this product.
Products when not in use for a long time, please wipe clean, load cases, placed in
ventilated and dry place, in order to avoid the product be affected with damp and
affect use.
This chapter sums up the most frequently encountered problems in using this product
If you have problems not mentioned in the list, you should try the following steps.
Turning off the power of the product, unplug the power plug from the socket
Keep this product closed 60 minutes.
Insert the plug into the power socket and open the switch.
If the problem persists, please contact our customer service center.
the fault
the reason
management
The product can't work.
the socket is unpluged.
Power button is not open
This product has just finished
massage 20 minutes and
automatically switch machine
to stay mode
Products placed on the over-
load (for example, someone
standing on the products, or
have a weight placed on top
of the product).
plug the socket safely
open the power
NO/OFF
If you want to
massage again,please click
NO/OFF again.
Unplug the product power plug,
remove the excess weight.
Please insert product power and
will be open again.
product heat
The power supply cord
damaged, the product smoke
The thermostat heating
disconnect protection
You already make the pro-
duct more groups of mass-
age 20 minutes.
Cool
Internal explosion
Remove the power plug and let
its cooling products, after use
unplug the power plug of the
product
Stop using immediately and
contact the seller.
Method of use
Model:SL-D180
Name:Neck and shoulder warm massager
Ated voltage:12V
Rated power:24W
Rated working time:15minutes
Product safeguard construction: