Mastervolt MasterBus Power Interrupter Operation & User’s Manual
Read Online
Read the Mastervolt MasterBus Power Interrupter Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
USERS MANUAL / GEBRUIKERSHANDLEIDING
BETRIEBSANLEITUNG / MANUEL D’UTILISATION
MANUAL DE UTILIZACION / INSTRUZIONI PER L’USO
MasterBus Power Interrupter
Switch off (part of) MasterBus network for power saving
MASTERVOLT
Snijdersbergweg 93,
1105 AN Amsterdam
The Netherlands
Tel.: +31-20-3422100
Fax.: +31-20-6971006
www.Mastervolt.com
Copyright © 2015 Mastervolt v 1.0 May 2015
ENGLISH:
PAGE 1
May 2015 / MasterBus Power Interrupter / EN
1 GENERAL INFORMATION
1.1
Use of this manual
Copyright © 2015 Mastervolt. All rights reserved.
Reproduction, transfer, distribution or storage of part
or all of the contents in this document in any form
without the prior written permission of Mastervolt is
prohibited.
This manual serves as a guideline for the safe and
effective
operation
of
the
MasterBus
Power
Interrupter.
Keep this manual at a secure place!
1.2
Guarantee specifications
Mastervolt guarantees that this product was built
according to the legally applicable standards and
stipulations. If you fail to act in accordance with the
regulations, instructions and stipulations in this
user’s manual, damage can occur and/or the
product will not fulfil the specifications. This may
mean that the guarantee will become null and void.
The standard guarantee period is two years after
date of purchase.
1.3
Liability
Mastervolt can accept no liability for:
consequential damage due to use of the
MasterBus Power Interrupter;
possible errors in the manuals and their results;
Use that is inconsistent with the purpose of the
product.
CAUTION!
Never remove the identification label.
2 FUNCTION
The MasterBus Power Interrupter is designed to
switch off (part of) the MasterBus network to reduce
power drain from, for instance, a battery. An internal
relay (dis)connects MasterBus power between the
two MasterBus connectors.
The MasterBus Power Interrupter operation is
entirely MasterBus based. See www.mastervolt.com
for information about MasterBus and the MasterBus
event structure. The table below shows the
functions.
Monitoring
Description
Default
Range
State
Part of MasterBus network can be switched on
(Activated) or off (Standby). Read only.
Activated
Activated/ Standby
Control
Button to change the State.
Activated
Activated/ Standby
Configuration
General
Language
Set the MasterBus Power Interrupter menu
language
English
See specifications
Device name
Any name you wish with 12 characters max
Depowering
12 characters max
Events locked
Check box for installers to lock event
configuration. Only operable by installers.
Unchecked
Unchecked/
Checked
Configuration Startup
Startup
Select condition at Startup.
On
On/ Off/ Last
Event commands
Activate
The MasterBus Power Interrupter can be
switched on (Activated) or off (Standby) with this
Event command.
-
-
MPC stop
Do not use.
-
-
MPC reduce
Do not use.
-
-
EN / MasterBus Power Interrupter / May 2015
3
3 INSTALLATION
3.1
Overview
Insert the MasterBus cables, see below.
Functional scheme of the MasterBus Power Interrupter.
3.2
Operation.
One (free choice) of the MasterBus connectors
should be connected to a MasterBus powering
device, like a MasterBus USB Interface or Mass
Charger, with a MasterBus cable.
The
other
MasterBus
connector
should
be
connected to a non-powering device like a
MasterView Easy display. You will then be able to
disconnect the MasterView Easy display from
MasterBus power. Every non-powering MasterBus
device will be disconnected from MasterBus power
attached to this connection.
The default start-up configuration is “On”. This
means that MasterBus Power is available (switched
on) in a start-up situation. This setting can be
changed to “Off” or “Last” in the configuration page
of MasterBus. Use “Last” if you want the MasterBus
Power Interrupter to remember the last state in a
start-up situation.
The MasterBus Power Interrupter can be used to
make a segregation between powering and non-
powering devices on a MasterBus network. By doing
so, you can manually switch the MasterBus Power
off by changing the device state to standby using the
control button in the monitoring page of MasterBus.
Events are available to change the device state
automatically.
MasterBus
Power
(non-powering
devices) can be switched off (Standby) when, for
instance, a low battery situation is detected in a
MasterShunt or Mass Combi.
1. Communication LED, illuminating when
the state is “Activated”
MasterBus connector
Function:
“Standby”: Relay is open Switched off
MasterBus Power.
“Activated”: Relay is closed Switched
on Masterbus Power.
MasterBus Power Interrupter
Article number:
77031550
Delivery also includes:
MasterBus cable, MasterBus Terminating device, User’s manual
Function of instrument:
Switching off (part of) MasterBus network for power saving
Languages available:
English
Power consumption:
132 mW
MasterBus Powering:
No
Din rail mounting:
Yes, Din rail 30 mm [1.2 inch]
Protection degree:
IP 21
Dimensions:
66 x 78 x 32 mm [2.6 x 3.1 x 1.3 inch]; see drawing below
Weight:
Approx. 80 gr [0.18 lb]
= MasterBus connector
Dimensions in mm (inch) and connections
4,5 [0.18]
69 [2.7]
4.0 [0.16]
33 [1.3]
33 [1.3]
6.0 [0.24]
78 [3.1]
32 [1.3]
4.0 [0.16]
Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands