IMPORTANT NOTE: The information contained in this document supersedes all previously published

information regarding this product. Product specifications are subject to change without prior notice. Part Number MN/CRS180.IOM Revision 8 CRS-180 70/140 MHz IF 1:1 Redundancy Switch Installation and Operation Manual Accessory Product for use only with Comtech EF Data CDM-625, CDM-750, CDM-570, CDM-700, CDM-710, and CDM-710G Modems (Modem Firmware and Hardware Requirements Apply)

ER-CRS180-EA8 Rev -

This document is not subject to revision/update! PLM CO C-0027990 Page 1 of 2 Errata A Comtech EF Data Documentation Update Original Manual Part Number/Rev: MN/CRS180.IOM REV 8 Errata Number/ PLM Document ID: ER-CRS180-EA8 PLM CO Number: C‐0027990 Comments: The updated information will be incorporated into the next formal revision of the manual. Change: NOTES: 1. CDM-625 and CDM-625A switch configurations are identical. 2. Throughout the manual, replace "CDM-625" with "CDM-625/A". 3. CDM-760 and CDM-750 switch configurations are identical.

ER-CRS180-EA8 Rev -

This document is not subject to revision/update! PLM CO C-0027990 Page 2 of 2 This page is intentionally blank.

Copyright © Comtech EF Data, 2011. All rights reserved. Printed in the USA.

Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161 CRS-180 70/140 MHz IF 1:1 Redundancy Switch Installation and Operation Manual Accessory Product for use only with Comtech EF Data CDM-625, CDM-750, CDM-570, CDM-700, CDM-710, and CDM-710G Modems (Modem Firmware and Hardware Requirements Apply) Part Number MN/CRS180.IOM Revision 8 October 24, 2011

TABLE OF CONTENTS

TABLE OF CONTENTS .............................................................................................................. III TABLES .................................................................................................................................. VII FIGURES................................................................................................................................. VII PREFACE ................................................................................................................................. XI About this Manual .................................................................................................................. xi Reporting Comments or Suggestions Concerning this Manual .................................................. xi Related Documents ................................................................................................................ xi Conventions and References ..................................................................................................xii Warnings, Cautions and Notes .................................................................................................. xii Examples of Multi‐Hazard Notices ............................................................................................. xii Metric Conversion ...................................................................................................................... xii Recommended Standard Designations...................................................................................... xii Trademarks ............................................................................................................................... xiii Safety and Compliance .......................................................................................................... xiii Electrical Safety and Compliance .............................................................................................. xiii Operating Environment ............................................................................................................ xiii Equipment Connection ............................................................................................................. xiv European Union Electromagnetic Compatibility (EMC) Directive (2004/108/EEC) ......................... xiv European Union Low Voltage Directive (LVD) (2006/95/EC) ................................................... xiv European Union RoHS Directive (2002/95/EC) .......................................................................... xv European Union Telecommunications Terminal Equipment Directive (91/263/EEC) .............. xv CE Mark ...................................................................................................................................... xv Warranty Policy ..................................................................................................................... xvi Limitations of Warranty ............................................................................................................ xvi Exclusive Remedies .................................................................................................................. xvii Getting Help ........................................................................................................................ xviii Contacting Comtech EF Data .................................................................................................. xviii Returning a Product for Upgrade or Repair .............................................................................. xix CHAPTER 1. INTRODUCTION ......................................................................................... 1–1

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Table of Contents MN/CRS180.IOM iv 1.1 Overview .................................................................................................................. 1–1 1.1.1  Modem Side Connectors............................................................................................. 1–2 1.1.2  Antenna Side Connectors ........................................................................................... 1–3 1.2 Functional Description ............................................................................................. 1–3 1.2.1  Operation with CDM‐625/750/570/700/710/710G ................................................... 1–3 1.2.1.1 1:1 IP Redundancy Data Switching – Functional Description ............................. 1–5 1.2.1.1.1  CDM‐570 (with optional IP Module) Managed Switch or Router Modes ..... 1–5 1.2.1.1.2  CDM‐625/750/700/710/710G Managed Switch Mode ................................ 1–7 1.2.1.1.3  CDM‐625 (with Optional IP Packet Processor) – Router Mode .................. 1–10 1.3 Summary of Specifications ..................................................................................... 1–13 CHAPTER 2. INSTALLATION ........................................................................................... 2–1 2.1 Unpacking and Inspection ........................................................................................ 2–1 2.2 Mounting ................................................................................................................. 2–2 CHAPTER 3. MODEM AND SWITCH CONFIGURATION ................................................... 3–1 3.1 Overview .................................................................................................................. 3–1 3.2 Configuring CDM‐625s for 1:1 Redundancy .............................................................. 3–3 3.2.1  User Remote Ethernet M&C Interface ....................................................................... 3–3 3.2.2  Carrier‐in‐Carrier® Redundancy Configuration ........................................................... 3–4 3.3 CDM‐750 Operation in 1:1 Redundancy ................................................................... 3–5 3.4 Configuring CDM‐570s for 1:1 Redundancy .............................................................. 3–7 3.4.1  IP Redundancy Configuration ..................................................................................... 3–8 3.4.2  Non‐IP Redundancy Configuration ............................................................................. 3–9 3.5 Configuring CDM‐700s/CDM‐710s/CDM‐710Gs for 1:1 Redundancy ...................... 3–11 3.5.1  IP Redundancy Configuration ................................................................................... 3–12 3.5.2  Non‐IP Redundancy Configuration ........................................................................... 3–12 3.6 CRS‐180 Switch DIP Settings ................................................................................... 3–13 CHAPTER 4. CABLES AND CONNECTIONS ...................................................................... 4–1 4.1 Overview .................................................................................................................. 4–1 4.2 Cabling to the CDM‐625 ........................................................................................... 4–3 4.2.1 CRS‐180 Æ CDM‐625 Control and IF Interface Cabling Kit KT‐0000159 ....................... 4–3

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Table of Contents MN/CRS180.IOM v 4.2.2  Modem‐to‐Switch Control Interface Connection ....................................................... 4–4 4.2.3  Modem‐to‐Switch IF Interface Connection ................................................................ 4–5 4.2.4  Modem‐to‐User Data Interface Connections and Examples ...................................... 4–6 4.2.4.1 RS‐422/232 Interface Example ........................................................................... 4–7 4.2.4.2 HSSI Interface Example ....................................................................................... 4–7 4.2.4.3 ASI Interface Example ......................................................................................... 4–8 4.2.4.4 Quad E1 Interface Example ................................................................................. 4–9 4.2.4.5 G.703 Balanced Interface Example ................................................................... 4–10 4.2.4.6 G.703 Unbalanced Interface Example .............................................................. 4–10 4.2.4.7 Overhead Interface Example ............................................................................ 4–11 4.2.4.8 Engineering Service Channel (ESC) Interface Example ..................................... 4–11 4.2.4.9 10/100 Ethernet Interface Examples ................................................................ 4–12 4.2.4.9.1  Managed Switch Mode (with/without IP Packet Processor) ...................... 4–12 4.2.4.9.2  Router Mode (Optional IP Packet Processor Required) .............................. 4–13 4.2.4.9.3  Data Interface Connections using IP Sub‐Mux ............................................ 4–14 4.2.4.10 PMSI Interface Example ................................................................................ 4–14 4.3 Cabling to the CDM‐750 ......................................................................................... 4–15 4.3.1  Modem‐to‐Switch Control and IF Interface Connection .......................................... 4–15 4.3.2  Modem‐to‐User Data Interface Connections and Examples .................................... 4–17 4.3.2.1 RJ‐45 Gigabit Ethernet Data Interface Example ............................................... 4–17 4.3.2.2 Optical Gigabit Ethernet Interface Option Example ......................................... 4–18 4.3.2.3 Serial Data Interface Kit and Connection Examples ......................................... 4–19 4.3.2.3.1  KT/12542 Single G.703 E3/T3 75Ω (PIIC) Interface Kit ................................ 4–20 4.4 Cabling to the CDM‐570 ......................................................................................... 4–21 4.4.1  CRS‐180 Æ CDM‐570 1:1 Redundancy Kit KT/11599 ............................................... 4–21 4.4.2  Modem‐to‐Switch Control Interface Connection ..................................................... 4–22 4.4.3  Modem‐to‐Switch IF Interface Connection .............................................................. 4–23 4.4.4  Modem‐to‐User Data Interface Connections and Examples .................................... 4–24 4.4.4.1 RS‐422/232 Interface Example ......................................................................... 4–25 4.4.4.2 G.703 Balanced Interface Example ................................................................... 4–25 4.4.4.3 G.703 Unbalanced Interface Example .............................................................. 4–26 4.4.4.4 10/100 Ethernet Interface Example ................................................................. 4–27 4.5 Cabling to the CDM‐700 ......................................................................................... 4–29 4.5.1  Modem‐to‐Switch Control and IF Interface Connection .......................................... 4–29 4.5.2  Modem‐to‐User Data Interface Kits and Connection Examples ............................... 4–31 4.5.2.1 Dual G.703 E3/T3/STS‐1 75Ω Data Interface (CDI‐10) Kit KT/12542 and HSSI Data Interface (CDI‐60) Kit KT/12578 ....................................................................... 4–32 4.5.2.2 155MB Copper Data Interface (CDI‐50) Kit KT/12579 ...................................... 4–33 4.5.2.3 OC‐3 Data Interface (CDI‐50) Kits KT/12580 (Single‐Mode) or KT/12581 (Multi‐ Mode)................................................................................................................ 4–34 4.5.2.4 Gigabit Ethernet Data Interface (CDI‐70) Example ........................................... 4–35

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Table of Contents MN/CRS180.IOM vi 4.6 Cabling to the CDM‐710 ......................................................................................... 4–37 4.6.1  Modem‐to‐Switch Control and IF Interface Connection .......................................... 4–37 4.6.2  Modem‐to‐User Data Interface Kit and Connection Examples ................................ 4–39 4.6.2.1 ASI 75Ω Data Interface (CDI‐40) Kit KT/12579 .................................................. 4–40 4.6.2.2 HSSI Data Interface (CDI‐60) Interface Kit KT/12578 ........................................ 4–41 4.6.2.3 Gigabit Ethernet Data Interface (CDI‐70) Example ........................................... 4–42 4.7 Cabling to the CDM‐710G ....................................................................................... 4–43 4.7.1  Modem‐to‐Switch Control and IF Interface Connection .......................................... 4–43 4.7.2  Modem‐to‐User Data Interface Kit and Connection Examples ................................ 4–45 4.7.2.1 Single G.703 E3/T3/STS‐1 75Ω Data Interface (CDI‐10‐1) Kit KT/12583 ............... 4–46 4.7.2.2 HSSI Data Interface (CDI‐60) Kit KT/12586 ....................................................... 4–47 4.7.2.3 Gigabit Ethernet Interface (CDI‐70) Example ................................................... 4–48 CHAPTER 5. CONNECTOR PINOUTS ............................................................................... 5–1 5.1 Overview .................................................................................................................. 5–1 5.2 Modem Side: Type ‘BNC’ IF Connectors .................................................................... 5–2 5.3 J3 Control Connector (Top) – Modem ‘A’ .................................................................. 5–2 5.4 J4 Control Connector (Bottom) – Modem ‘B’ ............................................................ 5–3 5.5 Antenna Side: Type ‘BNC’ IF Connectors ................................................................... 5–3 APPENDIX A. CABLE DRAWINGS ..................................................................................... A‐1 A.1 Introduction .............................................................................................................. A‐1 A.2 Control Interface Cables ............................................................................................ A‐1 A.2.1 Universal Control Cable, DB‐9M Æ DB‐9M ............................................................. A‐2 A.2.2 Adapter Control Cable, RoHS, DB‐9M Æ DB‐15F .................................................... A‐3 A.2.3 Optional ‘Y’ Splitter Adapter Control Cable, (2X) DB‐9M Æ DB‐15F ....................... A‐4 A.2.4 Optional Control Cable, Non‐muting, DB‐9M Æ DB‐15F ........................................ A‐5 A.3 IF / Data Interface Cables .......................................................................................... A‐6 A.3.1 Modem to CRS‐180, 70/140 MHz Coaxial Cable, RoHS, Type ‘BNC’ 50Ω ................ A‐8 A.3.2 Modem to User, 70/140 MHz Coaxial Cable, RoHS, Type ‘BNC’ 75Ω ...................... A‐9 A.3.3 Modem to User, Splitter Cable, (2X) DB‐25M Æ DB‐25F ...................................... A‐10 A.3.4 Modem to User, CDM‐625 Data ‘Y’ Splitter Cable, (2X) DB‐9M Æ DB‐9F ............ A‐11 A.3.5 Modem to User, Quad E1 ‘Y’ Splitter Adapter Cable, (2X) DB‐15F Æ DB‐9M ....... A‐12 A.3.6 Modem to User, Quad E1 ‘Y’ Splitter Adapter Cable, (2X) RJ‐48F Æ DB‐9M ........ A‐13 A.3.7 Modem to User, Quad E1 ‘Y’ Splitter Adapter Cable Kit (KT‐0000122) ................. A‐14

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Table of Contents MN/CRS180.IOM vii A.3.8 Modem to User, Overhead User Data ‘Y’ Splitter Cable, (2X) HD‐44M Æ HD‐44F ...... ................................................................................................................................ A‐15 A.3.9 Modem to Modem Shielded Multi‐drop CnC® Plus, CDM‐625 1:1 Cable, DB‐9M Æ DB‐9M ................................................................................................................... A‐16 A.3.10 User to CRS‐180, Coax Cable, RoHS, Type ‘BNC’ 75Ω ............................................ A‐17 A.3.11 Modem to User, Optical Gigabit Ethernet Single‐Mode OR Multi‐Mode Cable Assemblies, (2X) Type ‘LC’ Æ (4X) Type ‘LC’ ............................................................ A‐18 A.3.12 Modem to User G.703 Balanced User Data ‘Y’ Splitter Cable, (2X) DB‐15M Æ DB‐15M ...................................................................................................... A‐19 A.3.13 Modem to User, HSSI User Data ‘Y’ Splitter Cable, (2X) HD‐50M Æ HD‐50F ........ A‐20 A.3.14 Modem to User, OC‐3 Single‐Mode OR Multi‐Mode Cable Assemblies, Type ‘SC/UPC’ Æ (2X) Type  ‘SC/UPC’ ........................................................................... A‐21 TABLES Table 1‐1. CRS‐180 Application Summary .................................................................................. 1–2 Table 3‐1. CRS‐180 DIP Switch Settings .................................................................................... 3–13 Table 5‐1. Modem Side Type ‘BNC’ Connectors ......................................................................... 5–2 Table 5‐2. J3 ‐ Modem ‘A’ Control Connector Pin Assignments ................................................. 5–2 Table 5‐3. J4 ‐ Modem ‘B’ Control Connector Pin Assignments ................................................. 5–3 Table 5‐4. J7 (Rx) and J8 (Tx) Type ‘BNC’ Connectors ................................................................. 5–3 FIGURES Figure 1‐1. CRS‐180 70/140 MHz IF 1:1 Redundancy Switch ..................................................... 1–1 Figure 1‐2. CRS‐180 – Modem Side Connectors ......................................................................... 1–2 Figure 1‐3. CRS‐180 – Antenna Side Connectors and Ground Lug ............................................. 1–3 Figure 1‐4. CDM‐570 1:1 IP Redundancy Router Mode – ‘A’ Online .......................................... 1–6 Figure 1‐5. CDM‐570 1:1 IP Redundancy Router Mode – Switchover (‘B’ Online) ..................... 1–7 Figure 1‐6. CDM‐625/750/700/710/710G 1:1 IP Redundancy Managed Switch Mode ............. 1–8 Figure 1‐7. CDM‐625/750/700/710/710G 1:1 IP Redundancy Managed Switch Mode – Switchover ..... ............................................................................................................................................. 1–9 Figure 1‐8. CDM‐625 1:1 IP Redundancy Router Mode – ‘A’ Online ........................................ 1–11 Figure 1‐9. CDM‐625 1:1 IP Redundancy Router Mode – Switchover (‘B’ Online) .................. 1–12 Figure 2‐1. KT/11708 Mounting Panel Kit (for horizontal or vertical mounting) ....................... 2–2 Figure 3‐1. CDM‐570 Configuration Interfaces ........................................................................... 3–7 Figure 3‐2. CDM‐570 CLI 1:1 Redundancy Configuration screen ............................................... 3–9 Figure 3‐3. CRS‐180 Antenna Side – DIP Switches .................................................................... 3–13 Figure 4‐1. CDM‐625 Modem‐to‐Switch Control Connections ................................................... 4–4 Figure 4‐2. CDM‐625 Modem‐to‐Switch 70/140 MHz IF Connections ....................................... 4–5 Figure 4‐3. CDM‐625 Block Diagram: User Æ Modem Æ Switch Æ Traffic .............................. 4–6 Figure 4‐4. CDM‐625 RS‐422/232 1:1 Example .......................................................................... 4–7

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Table of Contents MN/CRS180.IOM viii Figure 4‐5. CDM‐625 HSSI 1:1 Example ...................................................................................... 4–7 Figure 4‐6. CDM‐625 ASI 1:1 Example ........................................................................................ 4–8 Figure 4‐7. CDM‐625 Quad E1 1:1 Example ................................................................................ 4–9 Figure 4‐8. CDM‐625 G.703 Balanced 1:1 Example .................................................................. 4–10 Figure 4‐9. CDM‐625 G.703 Unbalanced 1:1 Example ............................................................. 4–10 Figure 4‐10. CDM‐625 Overhead 1:1 Example ......................................................................... 4–11 Figure 4‐11. CDM‐625 ESC 1:1 Example ................................................................................... 4–11 Figure 4‐12. CDM‐625 10/100 Ethernet 1:1 Example – Managed Switch Mode ..................... 4–12 Figure 4‐13. CDM‐625 10/100 Ethernet 1:1 Example – Router Mode ..................................... 4–13 Figure 4‐14. CDM‐625 PMSI 1:1 Example ................................................................................. 4–14 Figure 4‐15. CDM‐750 Modem‐to‐Switch Control & IF Connections – KT‐0000160 ................ 4–16 Figure 4‐16. CDM‐750 RJ‐45 Gigabit Ethernet 1:1 Example ..................................................... 4–17 Figure 4‐17. CDM‐750 Optical Gigabit Ethernet 1:1 Example .................................................. 4–18 Figure 4‐18. CDM‐750 Block Diagram: User Æ Modem Æ Switch Æ Traffic .......................... 4–19 Figure 4‐19. CDM‐750 G.703 E3/T3 PIIC Interface Kit – KT/12542 ........................................... 4–20 Figure 4‐20. CDM‐570 Modem‐to‐Switch Control Connections............................................... 4–22 Figure 4‐21. CDM‐570 Modem‐to‐Switch 70/140 MHz IF Connections ................................... 4–23 Figure 4‐22. CDM‐570 Block Diagram: User Æ Modem Æ Switch Æ Traffic .......................... 4–24 Figure 4‐23. CDM‐570 RS‐422/232 1:1 Example ...................................................................... 4–25 Figure 4‐24. CDM‐570 G.703 Balanced 1:1 Example ................................................................ 4–25 Figure 4‐25. CDM‐570 G.703 Unbalanced 1:1 Example ........................................................... 4–26 Figure 4‐26. CDM‐570 10/100 Ethernet 1:1 Example............................................................... 4–27 Figure 4‐27. CDM‐700 Modem‐to‐Switch Control & IF Connections – KT/12554 .................... 4–30 Figure 4‐28. CDM‐700 Block Diagram: User Æ Modem Æ Switch Æ Traffic .......................... 4–31 Figure 4‐29. CDM‐700 G.703 E3/T3/STS‐1 and HSSI 1:1 Example .............................................. 4–32 Figure 4‐30. CDM‐700 155MB Copper 1:1 Example ................................................................. 4–33 Figure 4‐31. CDM‐700 OC‐3 1:1 Example (Single‐Mode shown) .............................................. 4–34 Figure 4‐32. CDM‐700 Gigabit Ethernet (GigE) 1:1 Example .................................................... 4–35 Figure 4‐33. CDM‐710 Modem‐to‐Switch Control & IF Connections – KT/12554 .................... 4–38 Figure 4‐34. CDM‐710 Block Diagram: User Æ Modem Æ Switch Æ Traffic .......................... 4–39 Figure 4‐35. CDM‐710 ASI 1:1 Example .................................................................................... 4–40 Figure 4‐36. CDM‐710 HSSI 1:1 Example .................................................................................. 4–41 Figure 4‐37. CDM‐710 Gigabit Ethernet (GigE) 1:1 Example .................................................... 4–42 Figure 4‐38. CDM‐710G Modem‐to‐Switch Control & IF Connections – KT/12554 ................. 4–44 Figure 4‐39. CDM‐710G Block Diagram: User Æ Modem Æ Switch Æ Traffic .......................... 4–45 Figure 4‐40. CDM‐710G Single G.703 E3/T3/STS‐1 1:1 Example ............................................... 4–46 Figure 4‐41. CDM‐710G HSSI 1:1 Example ................................................................................ 4–47 Figure 4‐42. CDM‐710G Gigabit Ethernet (GigE) 1:1 Example ................................................. 4–48 Figure 5‐1. CRS‐180 – Modem and Antenna Side Connectors ................................................... 5–1 Figure A‐1.  Universal Control Cable (CEFD P/N CA/WR9378‐4) ................................................. A‐2 Figure A‐2. Adapter Control Cable (CEFD P/N CA/WR12135‐1) .................................................. A‐3 Figure A‐3. Optional ‘Y’ Splitter Adapter Control Cable (CEFD P/N CA/WR13011‐4).................. A‐4 Figure A‐4. Optional Control Cable (CEFD P/N CA‐0000187) ...................................................... A‐5

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Table of Contents MN/CRS180.IOM ix Figure A‐5. Tx/Rx 50Ω Type ‘BNC’ RoHS Coax Cable (CEFD P/N PL/0946‐1) ............................... A‐8 Figure A‐6. 75Ω Type ‘BNC’ User Data Coaxial Cable (CEFD P/N CA/BNC75OHM) ..................... A‐9 Figure A‐7. 1:1 User Data Splitter Cable (CEFD P/N CA/RB10461‐1) ......................................... A‐10 Figure A‐8. 1:1 User Data ‘Y’ Splitter Cable (CEFD P/N CA‐0000071) ........................................ A‐11 Figure A‐9. 1:1 Quad E1 User Data ‘Y’ Splitter Adapter Cable (CEFD P/N CA‐0000163) ........... A‐12 Figure A‐10. Quad E1 User Data ‘Y’ Splitter Adapter Cable (CEFD P/N CA‐0000164) ............... A‐13 Figure A‐11. Quad E1 User Data ‘Y’ Splitter Adapter Cable Kit (CEFD P/N KT‐0000122) .......... A‐14 Figure A‐12. Overhead User Data ‘Y’ Splitter Cable (CEFD P/N CA‐0000070) ........................... A‐15 Figure A‐13. Modem to Modem Shielded Multi‐drop CnC® Plus, CDM‐625 1:1 Cable (CEFD P/N CA‐0000276) ......................................................................................................... A‐16 Figure A‐14. Tx/Rx 75Ω Type ‘BNC’ RoHS Coax Cable (CEFD P/N PL/0813‐4) ........................... A‐17 Figure A‐15. Optical Gigabit Ethernet User Data Cable Assembly (See Table for CEFD P/N) .... A‐18 Figure A‐16. G.703 Balanced User Data ‘Y’ Splitter Cable (CEFD P/N CA/WR10522‐1) ............ A‐19 Figure A‐17. HSSI User Data ‘Y’ Splitter Cable (CEFD P/N PP/SC3523) ...................................... A‐20 Figure A‐18. OC‐3 User Data Cable Assembly (See Table for CEFD P/N) ................................... A‐21

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Table of Contents MN/CRS180.IOM x This page is intentionally blank.

About this Manual

This  manual  provides  installation  and  operation  information  for  the  Comtech  EF  Data  CRS‐180 70/140 MHz IF 1:1 Redundancy Switch.  This is a technical document intended for the persons responsible for the operation and maintenance of the CRS‐180 and its supported modems. Reporting Comments or Suggestions Concerning this Manual Comtech EF Data welcomes comments and suggestions regarding the content and design of this manual. To submit comments, contact the Comtech EF Data Technical Publications Department: [email protected]. Related Documents • Comtech EF Data CDM‐625 Advanced Satellite Modem Installation and Operation Manual  (CEFD P/N MN‐CDM625) • Comtech EF Data CDM‐750 Advanced High‐Speed Trunking Modem Installation and Operation Manual (CEFD P/N CDM‐750) • Comtech EF Data CDM‐570/CDM‐570L/CDMR‐570L  Satellite Modem Installation and Operation Manual (CEFD P/N MN/CDM570L.IOM) • Comtech EF Data CDM‐700 Satellite Modem Installation and Operation Manual  (CEFD P/N MN/CDM700.IOM) • Comtech EF Data CDM‐710 Broadcast Satellite Modem Installation and Operation Manual  (CEFD P/N CDM710.IOM) • Comtech EF Data CDM‐710G High‐Speed Satellite Modem Installation and Operation Manual (CEFD P/N MN‐CDM710G)

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Preface MN/CRS180.IOM xii Conventions and References Warnings, Cautions and Notes A WARNING gives information about a possible hazard that MAY CAUSE DEATH or SERIOUS INJURY. A CAUTION gives information about a possible hazard that MAY CAUSE INJURY or PROPERTY DAMAGE. A NOTE gives important information about a task or the equipment. A REFERENCE directs the user to additional information about a task or the equipment. Examples of Multi-Hazard Notices Metric Conversion Metric conversion information is located on the inside back cover of this manual. This information is provided to assist the operator in cross‐referencing non‐Metric to Metric conversions. Recommended Standard Designations Recommended Standard (RS) Designations have been superseded by the new designation of the Electronic Industries Association (EIA). References to the old designations may be shown when depicting  actual  text  displayed  on  the  individual  product  Web  or  Telnet  (i.e.,  remote  control) interface pages for the unit (e.g., RS‐232). All other references in the manual will be shown with the EIA designations.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Preface MN/CRS180.IOM xiii Trademarks Product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. The user should carefully review the following information: Safety and Compliance Electrical Safety and Compliance The unit complies with the EN 60950 Safety of Information Technology Equipment (Including Electrical Business Machines) safety standard. The equipment is rated for operation at ±12 volts DC. It has a maximum power consumption of 1 Watt, and draws a maximum of 80 mA at +12 volts DC and 120 mA at ‐12 volts DC. The power supply current is, in all circumstances, supplied by either a single Comtech EF Data modem, or a pair of these modems. IF THE UNIT IS OPERATED IN A VEHICLE OR MOVABLE INSTALLATION, MAKE SURE THE UNIT IS STABLE. OTHERWISE, EN 60950 SAFETY IS NOT GUARANTEED. Operating Environment DO NOT OPERATE THE UNIT IN ANY OF THESE EXTREME OPERATING CONDITIONS: • AMBIENT TEMPERATURES LESS THAN 0° C (32° F) OR MORE THAN 50° C (122° F). • PRECIPITATION, CONDENSATION, OR HUMID ATMOSPHERES OF MORE THAN 95% RELATIVE HUMIDITY. • UNPRESSURIZED ALTITUDES OF MORE THAN 2000 METRES (6561.7 FEET). • EXCESSIVE DUST. • FLAMMABLE GASES. • CORROSIVE OR EXPLOSIVE ATMOSPHERES.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Preface MN/CRS180.IOM xiv Equipment Connection THE CRS‐180 IS DESIGNED FOR OPERATION ONLY WITH THE COMTECH EF DATA MODEMS LISTED IN THIS MANUAL. THESE MODEMS SUPPLY DC OPERATING CURRENT (ELECTRONICALLY FUSED AND PROTECTED) AND CONTROL SIGNALS FOR THE CORRECT FUNCTIONING OF THIS UNIT. CONNECTION TO OTHER MANUFACTURERS’ EQUIPMENT COULD RESULT IN DAMAGE TO THE UNIT. THE CRS‐180 IS NOT COMPATIBLE WITH OTHER COMTECH EF DATA MODEMS NOT LISTED IN THIS MANUAL. European Union Electromagnetic Compatibility (EMC) Directive (2004/108/EEC) Independent testing verifies that the unit complies with the following standards: • Emissions, EN 55022 Class B – Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment. In a domestic environment, this deive may cause radio interference that requires the user to take adequate protective measures. • Immunity, EN 55082‐1 – Generic Immunity Standard: Residential , Commercial, and Light Industry. • Federal Communications Commission (FCC) Code of Regulation Part 15, Subpart B. TO MAKE SURE THAT THE UNIT COMPLIES WITH THESE STANDARDS, OBEY THESE INSTRUCTIONS: • Use coaxial cable that is of good quality for connections to the L‐Band Type ‘N’ Tx (transmit) and Rx (receive) female connectors. • Use Type 'D' connectors that have back‐shells with continuous metallic shielding. Type ‘D’ cabling must have a continuous outer shield (either foil or braid, or both). The shield must be bonded to the back‐shell. • Operate the unit with its cover on at all times. European Union Low Voltage Directive (LVD) (2006/95/EC) Symbol Description Type of power cord required for use in the European Community. ! CAUTION: Double‐pole/Neutral Fusing ACHTUNG:  Zweipolige bzw. Neutralleiter‐Sicherung

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Preface MN/CRS180.IOM xv International Symbols Symbol Definition Symbol Definition Alternating Current Protective Earth Fuse Chassis Ground For additional symbols, refer to Warnings, Cautions and Notes listed earlier in this Preface. European Union RoHS Directive (2002/95/EC) This unit satisfies (with exemptions) the requirements specified in the European Union Directive 2002/95/EC  on  the  Restriction  of  the  use  of  certain  Hazardous  Substances  in  Electrical  and Electronic Equipment (RoHS). European Union Telecommunications Terminal Equipment Directive (91/263/EEC) In  accordance  with  the  European  Union  Telecommunications  Terminal  Equipment  Directive 91/263/EEC,  the  unit  should  not  be  directly  connected  to  the  Public  Telecommunications Network. CE Mark Comtech EF Data declares that the unit meets the necessary requirements for the CE Mark.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Preface MN/CRS180.IOM xvi Warranty Policy Comtech EF Data products are warranted against defects in material and workmanship for a specific period from the date of shipment, and this period varies by product.  In most cases, the warranty period is two years. During the warranty period, Comtech EF Data will, at its option, repair or replace products that prove to be defective. Repairs are warranted for the remainder of the original warranty or a 90 day extended warranty, whichever is longer. Contact Comtech EF Data for the warranty period specific to the product purchased. For equipment under warranty, the owner is responsible for freight to Comtech EF Data and all related customs, taxes, tariffs, insurance, etc.  Comtech EF Data is responsible for the  freight  charges  only  for  return  of  the  equipment  from  the  factory  to  the  owner. Comtech  EF  Data  will  return  the  equipment  by  the  same  method  (i.e.,  Air,  Express, Surface) as the equipment was sent to Comtech EF Data. All equipment returned for warranty repair must have a valid RMA number issued prior to return and be marked clearly on the return packaging.  Comtech EF Data strongly recommends all equipment be returned in its original packaging. Comtech EF Data Corporation’s obligations under this warranty are limited to repair or replacement of failed parts, and the return shipment to the buyer of the repaired or replaced parts. Limitations of Warranty The warranty does not apply to any part of a product that has been installed, altered, repaired, or misused in any way that, in the opinion of Comtech EF Data Corporation, would affect the reliability or detracts from the performance of any part of the product, or  is  damaged  as  the  result  of  use  in  a  way  or  with  equipment  that  had  not  been previously approved by Comtech EF Data Corporation. The warranty does not apply to any product or parts thereof where the serial number or the serial number of any of its parts has been altered, defaced, or removed. The warranty does not cover damage or loss incurred in transportation of the product. The warranty does not cover replacement or repair necessitated by loss or damage from any cause beyond the control of Comtech EF Data Corporation, such as lightning or other natural and weather related events or wartime environments. The warranty does not cover any labor involved in the removal and or reinstallation of warranted equipment or parts on site, or any labor required to diagnose the necessity for repair or replacement.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Preface MN/CRS180.IOM xvii The warranty excludes any responsibility by Comtech EF Data Corporation for incidental or consequential  damages  arising  from  the  use  of  the  equipment  or  products,  or  for  any inability to use them either separate from or in combination with any other equipment or products. A fixed charge established for each product will be imposed for all equipment returned for warranty repair where Comtech EF Data Corporation cannot identify the cause of the reported failure. Exclusive Remedies Comtech EF Data Corporation’s warranty, as stated is in lieu of all other warranties, expressed, implied, or statutory, including those of merchantability and fitness for a particular purpose.  The buyer shall pass on to any purchaser, lessee, or other user of Comtech  EF  Data  Corporation’s  products,  the  aforementioned  warranty,  and  shall indemnify and hold harmless Comtech EF Data Corporation from any claims or liability of such purchaser, lessee, or user based upon allegations that the buyer, its agents, or employees  have  made  additional  warranties  or  representations  as  to  product preference or use. The remedies provided herein are the buyer’s sole and exclusive remedies.  Comtech EF Data  shall  not  be  liable  for  any  direct,  indirect,  special,  incidental,  or  consequential damages, whether based on contract, tort, or any other legal theory.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Preface MN/CRS180.IOM xviii Getting Help Contacting Comtech EF Data Contact Comtech EF Data for: • Technical Support – Product support or training. • Customer Service – Information on returning an in‐warranty or out‐of‐warranty product for upgrade  or  repair.  Be  prepared  to  provide  the  product  model  number  and  its  serial number. Contact Comtech EF Data Customer & Technical Support during normal business hours (Monday through Friday, 8 A.M. to 5 P.M Mountain Standard Time (MST)): For: Contact: CRS‐170A Technical Support and Service Telephone +1.480.333.4357 Email [email protected] Fax +1.480.333.2500 Comtech EF Data Web Site Main Page http://www.comtechefdata.com Customer and Technical Support http://www.comtechefdata.com/support.asp RMA (Return Material Authorization) http://www.comtechefdata.com/rmaform.asp Comtech EF Data Main Number +1.480.333.2200 Mailing Address 2114 West 7th Street Tempe, Arizona 85281 USA Review the Warranty Policy before contacting Comtech EF Data Technical Support or Customer Service.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Preface MN/CRS180.IOM xix Returning a Product for Upgrade or Repair Step Task 1 Go to the Comtech EF Data Service page (http://www.comtechefdata.com/service.asp) and read the Return Material Authorization section in its entirety. 2 Request a Return Material Authorization Number: • On the Comtech EF Data Service page: Select the Return Material Authorization hyperlink. • On the Comtech EF Data Support page (http://www.comtechefdata.com/support.asp): Click [Send RMA Request] (http://www.comtechefdata.com/rmaform.asp); • Fill out the RMA form completely; • Click [Send Email]. • Alternately: o Send an e‐mail providing this same detailed information to Comtech EF Data Customer Service ([email protected]). o Contact Comtech EF Data Customer & Technical Support by phone or fax. 3 Pack the product in its original shipping carton and protective packaging. 4 Ship the product back to Comtech EF Data. Shipping charges should be prepaid.

Chapter 1. INTRODUCTION

1.1 Overview Figure 1-1. CRS-180 70/140 MHz IF 1:1 Redundancy Switch The  CRS‐180  70/140  MHz  IF  1:1  Redundancy  Switch  module,  shown  in  Figure  1‐1,  is  a  50Ω, 70/140  MHz  Tx‐Rx  IF  signal  switch  designed  for  use  with  IF  satellite  modems  in  a  1:1 configuration. The Tx side switches the Online unit onto the transmit coaxial cable. The Rx side of the switch uses power dividers to provide both demodulators with the same IF signal from the LNB, thus reducing switching time. The CRS‐180 is designed to support 1:1 redundancy for Comtech EF Data CDM‐625, CDM‐750, CDM‐570, CDM‐700, CDM‐710, and CDM‐710G modems. Table 1‐1 summarizes the CRS‐180 1:1 IF  Switch  applications,  including  requirements  for  supporting  data  switching  hardware  and software.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–2 Table 1-1. CRS-180 Application Summary Modem 1:1 Data Switch Other Information* CDM-625 Built into the CDM-625 Firmware 1.1.1 or higher CDM-750 Built into the CDM-750 Firmware 1.1.1 or higher CDM-570 Built into the CDM-570 • Firmware 1.6.7 or higher • Hardware Revision 3 CDM-570 IP Module User-provided hub or Layer 2 switch Firmware 1.5.4.2 or higher CDM-700 Built into the CDM-700 • Firmware 1.1.6 or higher • Hardware Revision 3 CDM-710 Built into the CDM-710 • Firmware 2.4.1 or higher • Hardware Revision 3 CDM-710G Built into the CDM-710G Firmware 5.1.1 or higher * Firmware updates are free and may be downloaded from the Comtech EF Data web page. If a modem does not meet the hardware requirements, contact CEFD – hardware revision upgrades must be performed at CEFD. 1.1.1 Modem Side Connectors The modem side connectors, shown in Figure 1‐2 and outlined in the accompanying table, provide all necessary external connections between the CRS‐180 70/140 MHz IF 1:1 Redundancy Switch module and the specified Comtech EF Data modems. Name Ref Des Connector Type Function RX A J1 BNC IF Input to Modem ‘A’ RX B J2 BNC IF Input to Modem ‘B’ TX A J5 BNC IF Output from Modem ‘A’ TX B J6 BNC IF Output from Modem ‘B’ Control A J3 9-pin ‘D’ (female) Control Interface with Modem ‘A’ Control B J4 9-pin ‘D’ (female) Control Interface with Modem ‘B’ Figure 1-2. CRS-180 – Modem Side Connectors J6 TX B J5 TX A J3 Control A J2 RX B J1 RX A J4 Control B

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–3 1.1.2 Antenna Side Connectors Two 50Ω female BNC connectors on the antenna side of the CRS‐180 70/140 MHz IF Switch module provide the coaxial cable connections to the outdoor transmit and receive equipment. Refer to Figure 1‐3 and the accompanying table for details. Name Ref Des Connector Type Function RX J7 BNC IF Input TX J8 BNC IF Output Figure 1-3. CRS-180 – Antenna Side Connectors and Ground Lug 1.2 Functional Description The  CRS‐180  70/140  MHz  IF  1:1  Redundancy  Switch  module  performs  the  Tx  and  Rx  coaxial switching required for redundant modem operation with an outdoor BUC and LNB. 1.2.1 Operation with CDM-625/750/570/700/710/710G The CRS‐180 is configured with two modems to form a complete 1:1 redundant modem system. Within the CRS‐180, a redundancy controller continually monitors the status of faults for both modems to determine which modem should be Online and Offline. The control cables between the modems and the CRS‐180 include four signal groups: • First, serial full‐duplex communication lines are routed from one modem to the other modem  via  the  CRS‐180.  Using  these  lines,  this  Online  modem  can  interrogate  the Offline  modem  at  regular  intervals  to  determine  its  configuration.  If  a  difference  in configuration is detected, the Online modem will reconfigure the Offline modem so that the configurations are always synchronized. This process is entirely automatic – if the Offline modem is replaced, it does not have to be manually reprogrammed to match the Online modem. • Second, the Modem’s Unit, Tx and Rx faults signals from both modems are routed to the CRS‐180. This allows the redundancy controller to always know the health status of both modems.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–4 • Third, the online/offline signals are routed from the CRS‐180 to each modem. Based on the  modem  faults,  the  CRS‐180  will  determine  which  modem  should  be  Online  and Offline. In the event that both modems indicate faults through some malfunction, the CRS‐180 switch will select, by default, Modem ‘A’. • Fourth, +12V is routed from each modem to the CRS‐180 for operational power. This power from both modems is diode OR’d so that the switch remains active if power is lost from one of the modems. IF  Switching  –  The  CRS‐180  provides  IF  redundancy,  but  when  switching  occurs,  it accommodates more than just the IF signals. On the Rx side, the Rx IF signal from the LNB is split in a power divider to continuously drive both the Online and Offline demodulator. The Offline demodulator  can  then  maintain  lock  so  that  it  is  ready  to  quickly  assume  Online  status  for receive traffic when a switchover is required. Data  Switching  is  accomplished  inside  each  modem,  in  the  data  interface  itself.  A  ‘Y’  cable connects  both  the  Online  modem  and  the  Offline  modem  to  the  terrestrial  data  source. Transmit data drives both modems in parallel so that the standby modulator is always ready to come  Online.  Termination  impedance  for  the  modem  line  receivers  is  active  in  the  Online modem. On the Rx side of the interface, TRI‐STATE® control of the Offline modem line drivers keeps the Offline modem from interfering with the Rx data traffic. Send timing output from the Offline modem is also TRI‐STATE®1. Manual Switching is enabled by the User via the Online modem, through its front panel or by remote control. Automatic Switching Selection is controlled by the User via the Online modem.  Then,  from  the  CRS‐180,  the  User  determines  the  conditions that cause an automatic switchover using two DIP switches – Unit+Tx and Unit+Rx – located on the antenna side of the CRS‐180 and labeled Switch Conditions. This selection provides a great deal of flexibility in the operation of the switch: the User can select between Modem Unit faults  only;  Modem  Unit  faults  or  Receive  Traffic  faults;  Modem  Unit faults or Transmit Traffic faults; or all three. Also located on the antenna side of the CRS‐180 are two green LEDs that indicate which modem is Online. With the ‘bridging’ architecture of the CRS‐180 (whereby identical terrestrial data traffic signals are  routed  to  both  Online  and  Offline  modems),  the  redundancy  controller  can  avoid unnecessary switchovers. By examining the fault status of both modems, it can infer if the fault is external to the system. For example, the CRS‐180 has been configured to switch following Unit faults  or  Transmit  Traffic  faults,  and  the  modems  have  been  configured  for  external  clock operation. Now, suppose that the external equipment (network, multiplex, router, etc.) fails – both the Offline and Online modems will now show a Transmit Traffic fault (No Clock Detected from  Terrestrial  Port).  The  CRS‐180  Controller  State  Machine  will  see  that  both  faults  have 1 TRI‐STATE is a registered trademark of National Semiconductor.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–5 occurred at the same time (in fact, within a 0.5 second window), and infers that the fault is external. Therefore, no unnecessary switchover is initiated. 1.2.1.1 1:1 IP Redundancy Data Switching – Functional Description 1.2.1.1.1 CDM-570 (with optional IP Module) Managed Switch or Router Modes • Do not use the M&C Ethernet port (bottom RJ‐45 connector) when the optional IP Module is installed. • All  configuration  changes  can  only  be  made  to  the  Online  Modem  and  will require the User to “Save Parameters to permanent storage” to ensure the configuration change is also applied to the Backup Modem. Managed  Switch  (Ethernet  Bridge)  Mode:  For  the  CDM‐570  in  Managed  Switch  Mode  (also known as “Ethernet Bridge Mode”) the user MUST use an external Ethernet hub to insure that traffic will continue after a switchover. If an Ethernet switch is used, there could be a several minute outage while the Ethernet Switch “re‐learns” the correct output Ethernet port. Using a “dumb”  Ethernet  hub  allows  LAN‐to‐WAN  traffic  to  continue  even  after  a  switchover  occurs since both modems will be receiving the LAN traffic. In Managed Switch Mode, both modems should be assigned a unique Management IP address on the same subnet in order to share the parameter file. Router  Mode:  For  the  CDM‐570  in  Router  Mode,  the  user  should  use  an  external  Ethernet switch. Router mode does not require a “dumb” hub as with Managed Switch Mode and, for performance reasons, an Ethernet switch is highly recommended. In Router Mode, both modems must be assigned a unique Management IP address on the same subnet (172.18.10.21/24 and 172.18.10.22/24 as shown in Figure 1‐4 and Figure 1‐5). This is used  to  share  the  param  file.  A  Traffic  IP  address  on  the  subnet  must  also  be  assigned (172.18.10.20/24) in the Online modem. Whichever modem is Online will assume the Traffic IP. When there is a switchover to the backup modem, this modem will now assume the Traffic IP. As shown in Figure 1‐5, the backup modem will also broadcast a “gratuitous ARP” that will tell all local devices to now associate a new MAC address for the Traffic IP 172.18.10.20. Each device will update their ARP tables and traffic will resume virtually instantaneously.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–6 Figure 1-4. CDM-570 1:1 IP Redundancy Router Mode – ‘A’ Online

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–7 Figure 1-5. CDM-570 1:1 IP Redundancy Router Mode – Switchover (‘B’ Online) 1.2.1.1.2 CDM-625/750/700/710/710G Managed Switch Mode A standard, user‐provided Ethernet Layer 2 Switch is needed when a CDM‐625, CDM‐750, CDM‐ 700, CDM‐710, or CDM‐710G modem is configured for Managed Switch Mode (also known as “Ethernet Bridge Mode”) terrestrial traffic. A Layer 2 Switch is designed to limit the traffic that egresses each port by only sending Ethernet packets out the port that the destination network device is located. The switch maintains a table ‐ known as the dynamic Content‐Addressable Memory (CAM) table ‐ that maps MAC addresses to switch ports. When a packet arrives, in which an entry for that specific destination MAC is

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–8 CDM-625/750/700/710/710G CDM- 625/750/700/710/710G CDM-625/750/700/710/710G unknown to the switch, it sends the packet out all ports and waits for response packets in an attempt  to  identify  which  port  that  particular  MAC  resides.  Once  the  device  responds,  the switch is able to map the MAC to the port in the CAM table. Any new arriving packets destined for that MAC address will be forwarded only out the port identified in the CAM table. Most switch CAM tables do have a flush or timeout value, but is normally set to a very high number to limit the amount of times the switch has to broadcast a packet out all ports. It is also important to note that CAM entries for a specific port are cleared when a port link goes down. Figure 1-6. CDM-625/750/700/710/710G 1:1 IP Redundancy Managed Switch Mode Figure 1‐6 shows a Managed Switch Mode 1:1 IP Redundancy setup with the Ethernet data interface of both modems connected to a Layer 2 Switch. Both modems are operational – Modem ‘A’ is Online and connected to Port 4 of the Layer 2 Switch. Modem ‘B’ is Offline and connected to Port 3 of the Layer 2 Switch, but the Ethernet link is not active because only the Online modem will have an active Ethernet data interface. Also, Local PC ‘A’ is connected to Port 1 of the Layer 2 Switch. When Ethernet traffic is sent from Local PC ‘A’ across the satellite link to remote PC ‘B’, the Layer 2 Switch will “learn” the MAC addresses of both PCs and will have these dynamic entries in its CAM Table: Port 1     MAC 00‐00‐00‐00‐00‐11  (Local PC ‘A’) Port 3     No entries, port down Port 4     MAC 00‐00‐00‐00‐00‐22  (Remote PC ‘B’)

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–9 CDM-625/700/710/710G/750 CDM-625/750/700/710/710G CDM-625/750/700/710/710G Figure 1-7. CDM-625/750/700/710/710G 1:1 IP Redundancy Managed Switch Mode – Switchover As shown in Figure 1‐7, in the event of a fault occurring on the Online Modem ‘A’, the following will occur: • Modem ‘A’ goes offline and disables its Ethernet data interface. • Simultaneously, Modem ‘B’ goes online and enables its Ethernet data interface. • Layer 2 Switch ‘A’ senses that Port 4 is no longer active and clears the CAM table entries for that port. • When the next Ethernet packet from Local PC ‘A’ destined for Remote PC ‘B’ arrives at Switch ‘A’, there is no CAM entry for the PC ‘B’ MAC, so it will be broadcast to all active ports. • When  the  next  Ethernet  packet  from  Remote  PC  ‘B’  arrives  at  Switch  ‘A’,  Switch  ‘A’ dynamically adds the PC ‘B’ MAC to the CAM table for Port 3.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–10 Note the following: 1. The Managed Switch Mode method of redundancy is intended to be equivalent to pulling the Ethernet cable from one port and putting it into a different port on the same switch. 2. For  the  CDM‐625  modem:  The  user  may  configure  one  of  the  CDM‐625’s  four  available 10/100  Ethernet  ports  for  M&C  Ethernet.  As  configured  in  Dedicated  Management  Port Mode,  when  the  modem  is  offline  the  M&C‐designated  port remains functional  and available for operation, while the three remaining ports are unavailable. Otherwise, if none of  the  10/100  Ethernet  ports  are  reserved  for  M&C  operation,  all  four  ports become unavailable when the modem is offline. This configuration must be enabled on both modems. Refer to the CDM‐625 Advanced Satellite Modem Installation and Operation Manual for instructions to configure one of the four 10/100 Ethernet ports for each modem for remote Ethernet M&C. Dedicated  Management  Port  Mode  is  not  configurable  for  use  when  the optional  IP  Packet  Processor  is  installed  and  enabled.  With  the  IP  Packet Processor enabled, as a means to avoid Ethernet Networking Loops, only one of the CDM‐625’s four 10/100 Ethernet Ports is used for each modem at any given time. 3. For  the  CDM‐750/700/710/710G  modems:  When  the  modem  is  offline,  although all GigE port(s) are  unavailable,  the  M&C  Ethernet  port  remains  functional  and  available  for operation. 4. Installation must use a true switching device, not a hub device. 1.2.1.1.3 CDM-625 (with Optional IP Packet Processor) – Router Mode All configuration changes can only be made to the Online Modem and will require the  User  to  “Save  Parameters  to  permanent  storage”  to  ensure  the  configuration change is also applied to the Backup Modem. For  the  CDM‐625  with  the  optional  IP  Packet  Processor  installed  and  enabled  and  the configuration set for Router Mode, the user needs to provide an external Ethernet switch. In Router Mode, both modems must be assigned a unique Management IP address on the same subnet (172.18.10.21/24 and 172.18.10.22/24 as shown in Figure 1‐8 and Figure 1‐9). This is used  to  share  the  param  file.  A  Traffic  IP  address  on  the  subnet  must  also  be  assigned (172.18.10.20/24) in the online modem. The Traffic IP Address must be different from either Management IP Address.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–11 Whichever modem is online will assume the Traffic IP. When there is a switchover to the backup modem, this modem will now assume the Traffic IP. Per Figure 1‐9, the backup modem will also broadcast a “gratuitous ARP” which will tell all local devices to now associate a new MAC address for the Traffic IP 172.18.10.20. Each device will update their ARP tables and traffic will resume virtually instantaneously. Figure 1-8. CDM-625 1:1 IP Redundancy Router Mode – ‘A’ Online

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–12 Figure 1-9. CDM-625 1:1 IP Redundancy Router Mode – Switchover (‘B’ Online)

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Introduction MN/CRS180.IOM 1–13 1.3 Summary of Specifications Equipment Type IF 1:1 Redundancy Switch Manufacturer Comtech EF Data, Tempe, Arizona Comtech EF Data Modems Supported • CDM-625 Advanced Satellite Modem (18 kbps – 25 Mbps) • CDM-750 Advanced High-Speed Trunking Modem • CDM-570 70/140 MHz Satellite Modem • CDM-700 70/140 MHz Satellite Modem • CDM-710 70/140 MHz Broadcast Satellite Modem • CDM-710G 70/140 MHz High-Speed Satellite Modem Operating Modes • Fully Automatic under control of supporting 1:1 switch. • Manual under control of supporting 1:1 switch. Architecture • Full bridging architecture with configuration synchronization. • Tx switching guarantees the Offline modem is muted at least 60 dB down. • Rx IF signal fed to both Online and Standby units. Switch Conditions Tx/Rx switching follows state of supporting data switching via control input from data switch. IF Switching/ Splitting • Tx IF: Switched by RF relay (1.5 dB max loss, 40 dB min ON/OFF isolation) • Rx IF: Passive power splitting (4dB max loss) Tx-Rx Isolation 40 dB min, 50 - 190 MHz IF Impedance Optimized for 50Ω (> 10 dB return loss on external IF ports), 75Ω supported with the use of external RF transformers (included). IF Connectors 50Ω BNC Female IF Frequency Range 50 to 190 MHz Weight 1.1lbs (0.5kg) Dimensions 1.7 H x 5.7 W x 4.1 D inches (43 H x 143 W x 104 D mm [excluding connectors]) 19-inch rack mounting kit available. Power requirements 1 Watt maximum +12 volts DC @ 80 mA (max) (Power supplied by modems) Approvals ‘CE’ as follows: • EMC • Safety

Chapter 2. INSTALLATION

2.1 Unpacking and Inspection The CRS‐180 70/140 MHz IF 1:1 Redundancy Switch module and its Installation and Operation Manual were packaged and shipped in a reusable cardboard carton containing protective foam spacing. This equipment contains parts and assemblies sensitive to damage by Electrostatic Discharge (ESD). Use ESD precautionary procedures when handling the equipment. Once opened, inspect the shipment: Step Task 1 Keep all shipping materials for storage or reshipment. 2 Check the packing list to ensure the shipment is complete. 3 Inspect the equipment for any possible damage incurred during shipment. Contact the carrier and Comtech EF Data immediately to submit a damage report if damage is evident. 4 Review this manual and the pertinent modem’s  Installation and Operation Manual carefully to become familiar with 1:1  redundancy operation. 5 Proceed to Sect. 2.2  Mounting.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Installation MN/CRS180.IOM 2–2 2.2 Mounting Figure 2-1. KT/11708 Mounting Panel Kit (for horizontal or vertical mounting) The CRS‐180 is designed to be freestanding, or mounted at the rear of the rack containing the modems using the available Comtech EF Data Mounting Panel Kit KT/11708. As shown in Figure 2‐1, this kit  allows the module to be mounted into the rack horizontally or vertically. Otherwise, because of the module’s small size and weight, the user may choose to let the module hang freely, supported by the interfacing cables.

Chapter 3. MODEM AND SWITCH

CONFIGURATION 3.1 Overview In order to avoid damage to the modems and CRS‐180 switch, it is important to follow this sequence of configuration: • First,  configure  the  modems  for  1:1  redundant  operation  as  outlined  in  this chapter in Sect. 3.2 through Sect. 3.5. • Second, once the modems have been properly configured for 1:1 redundant operations, set the DIP switches on the CRS‐180 to the correct modem selection, as outlined in this chapter in Sect. 3.6 CRS‐180 Switch DIP Settings. • Third, once the modem and switches have been properly configured, connect the cables between the powered OFF modems and switch as outlined in Chapter 4. CABLES AND CONNECTIONS.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–2 This page is intentionally blank.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–3 3.2 Configuring CDM-625s for 1:1 Redundancy CDM‐625 Advanced Satellite Modem Installation and Operation Manual  (CEFD P/N MN‐CDM625) The  CDM‐625  Advanced  Satellite  Modem  automatically  detects  if  it  is  connected  to  a  1:1 redundancy system – the steps required to configure both modems are therefore minimal, with some exceptions: • If  the  CDM‐625  has  the  optional  IP  Packet Processor  installed  and  enabled,  1:1 Redundancy is controlled from the CDM‐625 Web Server Interface Redundancy page. When  both  the  traffic  and  backup modems are equipped with the optional IP Packet Processor and are connected to the CRS‐180  L‐Band  1:1  Redundancy  Switch), there  is  no  need  to  use  the  drop‐down menu here, as Packet Processor Redundancy is enabled automatically. If it is desired to operate either modem outside of the redundant setup as a standalone unit, use the drop‐down menu to select Packet Processor Redundancy for that specific modem as Disabled. • If  terrestrial  data  is  not  Ethernet  and  CnC  will  not  be  used,  then  no  modem  1:1 redundancy configuration is needed. Otherwise, if either apply, refer to the sections that follow. 3.2.1 User Remote Ethernet M&C Interface The user may configure one of the CDM‐625’s four available 10/100 Ethernet ports for M&C Ethernet. As configured in Dedicated Management Port Mode, when the modem is offline the M&C‐designated port remains functional and available for operation, while the three remaining ports are unavailable. Otherwise, if none of the 10/100 Ethernet ports are reserved for M&C operation, all four ports become unavailable when the modem is offline. This configuration must be enabled on both modems. Refer  to  the  CDM‐625  Advanced  Satellite  Modem  Installation  and  Operation  Manual  for instructions to configure  one of the four 10/100 Ethernet ports for each modem for remote Ethernet M&C. Dedicated  Management  Port  Mode  is  not  configurable  for  use  when  the  optional  IP Packet Processor is installed and enabled. With the IP Packet Processor enabled, as a means  to  avoid  Ethernet  Networking  Loops,  only  one  of  the  CDM‐625’s  four  10/100 Ethernet Ports is used for each modem at any given time.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–4 3.2.2 Carrier-in-Carrier® Redundancy Configuration If Carrier‐in‐Carrier® (CnC) is utilized, the CnC control setting must be set to Redundancy mode using the CDM‐625 front panel menus. Configuration of the CnC control setting for CDM‐625 1:1 Redundancy is as follows: Step Procedure 1 From the top-level SELECT: menu, navigate each menu level using the ◄► arrow keys and the ENTER key until the PMSI control mode screen appears as follows: SELECT: Configuration Æ CnC Æ PMSI-control CnC PMSI mode: Redundancy (Idle, Redundancy, Talk, Listen) (v) From the CnC PMSI mode screen, use the ▲ ▼ arrow keys to select Redundancy, and then press ENTER. 2 The two CDM-625s will now need to be connected together via use of a 1:1 PMSI cable (note that this cable bypasses the CRS-180). Chapter 4. CABLES AND CONNECTIONS. The Pre-Mapped Symbol Interface (PMSI) is a function associated with DoubleTalk® Carrier- in-Carrier® that permits the modulator in a selected unit to provide a direct copy of its output (the outbound interferer) to the second modem. The other modem may then choose to take the PMSI signal and use it for its own CnC reference. In this 1:1 redundancy, the PMSI is an RS-485 multi-drop bus system where one device transmits and the other device on the multi- drop bus is configured to receive.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–5 3.3 CDM-750 Operation in 1:1 Redundancy CDM‐750 Advanced High‐Speed Trunking Modem Installation and Operation Manual (CEFD P/N MN‐CDM750) The CDM‐750 Advanced High‐Speed Trunking Modem automatically detects if it is connected to a 1:1 redundancy system. With both modems automatically configured for 1:1 operation, the online  modem  keeps  the  offline  modem  updated  as  online  modem  configuration  changes occur. The user can also manually ‘force’ backup of the online modem. Use the CDM‐750 front panel to select the  Utility X 1:1 screen: Press ENTER key to force Unit into Standby (1:1 only) If the unit is part of a 1:1 redundant pair and this unit is currently online, press ENTER to force the current unit to switch to standby mode.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–6 Notes:

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–7 3.4 Configuring CDM-570s for 1:1 Redundancy CDM‐570/CDM‐570L/CDMR‐570L  Satellite  Modem  Installation  and  Operation Manual (CEFD P/N MN/CDM570L.IOM) For correct operation of the CRS‐180, the CDM‐570 Satellite Modems must have the following installed: • Base Modem Firmware Version 1.6.7 (or higher) • IP Module Firmware Version 1.5.4.2 (or higher) • Hardware Revision 3 • This manual also presumes that the CDM-570 has been factory-configured for 50Ω Rx and Tx operation. If the modems do not meet this requirement, contact Comtech EF Data. Firmware updates  are  free  and  may  be  downloaded  from  the  CEFD  web  page.  Hardware revision upgrades must be performed at CEFD. CDM-570 Front Panel Serial console Command Line Interface (CLI) Figure 3-1. CDM-570 Configuration Interfaces Because the modem automatically detects if it is connected to a 1:1 redundancy system, the steps required to configure both modems are minimal. Use the modem’s front panel to fully configure, monitor, and control the modem operation. The front panel keypad and display are used to display all available options. Nested menus display all prompts needed by the User to carry  out  a  required  action.  Refer  to  the  pertinent  modem’s  user  manual  for  detailed configuration information. Alternately, configuration, monitoring and control of redundant systems is possible via remote means over an RS‐485 multi‐drop bus using the Serial console Command Line Interface, where data is transmitted in asynchronous serial form using ASCII characters (see Figure 3‐1). Refer back to the modem manual for detailed information on either methodology.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–8 3.4.1 IP Redundancy Configuration Setup of a CDM‐570 1:1 IP Redundancy System, using the CLI, is as follows: Step Procedure 1 The two modems will need an Ethernet connection to each other through a Layer 2 switch (preferred) or hub. 2 Before connecting the modems to the CRS-180, you will need to first configure the following CDM-570 IP module settings: • Redundancy Configuration Æ 1:1 Redundancy set to DISABLED. • Administration Æ Working Mode: Both modems need to be set to the same Working Mode. • Administration Æ Features: Both modems need to have the same IP Option Feature set. 3 On both modems, enter a unique IP Address that is on the same subnet (Interface Configuration Æ Ethernet Interface Æ IP Address). Verify that you can ping from one modem to the other (Operations and Maintenance Æ Diagnostics Æ Ping). 4 On both modems, set Redundancy Configuration Æ 1:1 Redundancy to ENABLED. Save Parameters to permanent storage and power down both modems. 5 Connect the modems to the CRS-180.. CDM‐570/CDM‐570L/CDMR‐570L Satellite Modem Installation and Operation Manual (CEFD P/N MN/CDM570L.IOM): Sect. H.6 Cabling with the CDM‐570 IF. 6 While monitoring the Serial console CLI on both modems, observe the following after powering on both modems at the same time (also observe the CRS-180 Online LEDs to see which modem is the Online modem). Online modem CLI displays: 1:1 Redundancy (Auto Detected) Redundancy: PARAM File Connection Established. Redundancy: Sending PARAM File... Offline modem CLI displays: 1:1 Redundancy (Auto Detected) Redundancy: Received PARAM File... Writing 5447 bytes to PARAM file on Flash 7 On the Online modem, select the Redundancy Configuration menu (Figure 3-2). Observe that the correct IP Address/Mask is displayed for the Local and Redundant Unit. You will then need to set the Traffic IP Address/Mask (this also needs to be in the same subnet as the Management IP addresses).

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–9 Figure 3-2. CDM-570 CLI 1:1 Redundancy Configuration screen All  configuration  changes  can  only  be  made  to  the  Online  CDM‐570  and  will require  the  user  to  “Save Parameters to permanent storage”  to ensure the configuration change is also applied to the Backup CDM‐570. 3.4.2 Non-IP Redundancy Configuration Setup  of  the  CDM‐570  modems  for  1:1  Redundancy,  when  the  terrestrial  data  type  is  non‐ Ethernet (i.e. RS422, G.703), is as follows: Step Procedure 1 On both modems, Enable 1:1 Redundancy: Redundancy Configuration Æ 1:1 Redundancy set to ENABLE. 2 Connect all cables – including the control cable, IF cable and data ‘Y’cables – to the modems and the CRS-180. Chapter 4. CABLES AND CONNECTIONS

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–10 Notes:

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–11 3.5 Configuring CDM-700s/CDM-710s/CDM-710Gs for 1:1 Redundancy • CDM‐700 Satellite Modem Installation and Operation Manual  (CEFD P/N MN/CDM700.IOM) • CDM‐710 Broadcast Satellite Modem Installation and Operation Manual  (CEFD P/N CDM710.IOM) • CDM‐710G Satellite Modem Installation and Operation Manual (CEFD P/N MN‐CDM710G) For  correct  operation  of  the  CRS‐180,  the  CDM‐700,  CDM‐710,  and  CDM‐710G modems must have the following installed: • For the CDM‐700:       ► Firmware Version 1.1.6 (or higher)       ► Hardware Revision A (chassis with round‐buttoned keypad) • For the CDM‐710:       ► Firmware Version 2.4.1 (or higher)       ► Hardware Revision A (chassis with round‐buttoned keypad) • For the CDM‐710G:       ► Firmware Version 5.1.1 (or higher) If the modems do not meet this requirement, contact Comtech EF Data. Firmware updates  are  free  and  may  be  downloaded  from  the  CEFD  web  page.  Hardware revision upgrades must be performed at CEFD. Note  that  Hardware  upgrades  are  possible  only  for  the  Rev.  A  chassis  and  later versions  of  the  CDM‐700/710  –  1:1  redundancy  operation  is  not  available  with hardware prior to Rev. A. Use each modem’s front panel to fully configure, monitor, and control the modem operation. The  front  panel  keypad  and  display  are  used  to  display  all  available  options.  Nested  menus display all prompts needed by the User to carry out a required action. Refer to the pertinent modem’s user manual for detailed configuration information.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–12 3.5.1 IP Redundancy Configuration Setup  of  the  CDM‐700/CDM‐710/CDM‐710G  modems  for  1:1  IP  Redundancy  (i.e.,  when  the terrestrial data type is GigE) is as follows: Step Procedure 1 Before connecting the modems to the CRS-180, you will need to first configure the following IP module settings on the modem. From the modem front panel: CONFIG Æ AUX (Redundancy Mode) Æ ENA/DIS set to Disable. 2 On both modems, set the redundancy to the Enable state: CONFIG Æ AUX (Redundancy Mode) Æ ENA/DIS set to Enable. Press ENTER to save parameters to flash memory 3 Connect all cables – including the control cable, IF cable and data cables – to the modems and the CRS-180. Additionally, both modems will need an Ethernet connection to each other through a Layer 2 switch. Chapter 4. CABLES AND CONNECTIONS 4 Verify that one modem is ONLINE by the front panel LEDs; also verify that the ONLINE LEDs for the CRS-180 indicate the same online state as the modems. All  configuration  changes  can  only  be  made  to  the  Online  Modem  and  will require  the  user  to  “Save Parameters to permanent storage”  to ensure the configuration change is also applied to the Backup Modem. 3.5.2 Non-IP Redundancy Configuration Setup of the CDM‐700/CDM‐710/CDM‐710G modems for 1:1 Redundancy when the terrestrial data type is non‐Ethernet (i.e. HSSI, G.703) is as follows: Step Procedure 1 On both modems, set the redundancy to the Enable state: CONFIG Æ AUX (Redundancy Mode) Æ ENA/DIS set to Enable. 2 Connect all cables – including the control cable, IF cable and data ‘Y’cables – to the modems and the CRS-180. Chapter 4. CABLES AND CONNECTIONS

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–13 3.6 CRS-180 Switch DIP Settings The ‘Switch Conditions’ DIP switches are set depending upon the type of Tx or Rx traffic conditions resultant of switchover. Some modems have additional settings or alarm  masks  that  affect  conditions  –  refer  to  the  pertinent  modem  manual  for detailed explanations. Figure 3‐3 shows the DIP switches for setting ‘Switch Conditions’ on the Antenna Side of the CRS‐180 70/140 MHz IF 1:1 Redundancy Switch. Table 3‐1 illustrates the ‘Switch Conditions’ DIP switch settings that determine switchover functionality for a given redundancy configuration. Table 3-1. CRS-180 DIP Switch Settings ‘Switch Conditions’ DIP Settings DIP Left Switch Right Switch Result Down (Off) Down Switchover upon a Unit fault Up Down Switchover upon a Unit or Tx Traffic fault Down Up Switchover upon a Unit or Rx Traffic fault Up Up Switchover upon a Unit or Tx Traffic or Rx Traffic fault Figure 3-3. CRS-180 Antenna Side – DIP Switches

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Modem and Switch Configuration MN/CRS180.IOM 3–14 Notes:

Chapter 4. CABLES AND

CONNECTIONS 4.1 Overview When  assembling  a  Comtech  EF  Data  1:1  Redundancy  System,  in  addition  to  purchasing  the desired modem pair (one Redundant modem, one Traffic modem), the user must also purchase a redundancy  kit  tailored  to  that  modem  choice.  This  kit  provides  –  in  addition  to  the  CRS‐180 70/140  MHz  IF  1:1  Redundancy  Switch  module  –  all  cables  and  components  required  for interconnection of the redundant configuration to various interfaces (i.e., control, IF, and data), excluding Ethernet, which requires user‐provided cables and Layer 2 switching. The  modem‐specific  sections  in  this  chapter  identify  the  redundancy  kit  required  for  that particular  configuration.  The  individual  redundancy  kit  item(s)  required  to  assemble  specific interface examples are further identified. • It is physically impossible to connect all available data interface solutions within a single 1:1 redundancy system at a given time. For example, when using the CDM‐625  in  a  1:1  system,  the  user  is  unable  to  establish  an  ASI  interface together  with  a  G.703  Unbalanced  interface,  or  an  RS‐422/232  interface together  with  an  HSSI  interface.  Therefore,  the  quantities  of  cables  and accessories furnished with each redundancy kit have been predetermined with this operational limitation taken into consideration. • The  type  of  1:1  Y‐Splitter  cable  required  for  modem‐to‐user  interconnection depends on the user’s data interface. It is essential to ensure that the control and IF connections, both Rx and Tx, are made correctly.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–2 This page is intentionally blank.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–3 4.2 Cabling to the CDM-625 1. For information on the CDM‐625’s  1:1  auto‐enable functionality, see: • Chapter 3. MODEM AND SWITCH CONFIGURATION • CDM‐625 Advanced Satellite Modem Installation and Operation Manual (CEFD P/N MN‐CDM625) 2. For information on the cables and cable assemblies specified in this section, see: • Appendix A. CABLE DRAWINGS 4.2.1 CRS-180 Æ CDM-625 Control and IF Interface Cabling Kit KT-0000159 Terrestrial data interface components/kits must be ordered separately. See Sect. 4.2.4  for  CDM‐625  terrestrial  data  interface  configuration  and  connection examples and details. Comtech EF Data’s KT‐0000159 1:1 Redundancy Control/IF Interface Cabling Kit is required for control and 70/140 MHz switch‐to‐modem cabling connections: KT-0000159 1:1 Redundancy Control / IF Interface Cabling Kit (CRS-180 Æ CDM-625) CEFD Part No. Qty Description Used For Ch. 4 Fig PL/11560-1 1 CRS-180 Switch – Top Assembly 1:1 Redundancy 4-1 4-2 CA/WR9378-4 2 Control Cable – Universal, DB-9M Æ DB-9M, 4’ Modem Æ Switch Control 4-1 PL/0946-1 4 IF (Tx/Rx) Coax Cable – 50Ω Type ‘BNC’, 4’ Modem Æ Switch IF Interface 4-2 XF/BNC-MF-50-75 2 Transformer, 50-75Ω, 2-200 MHz, BNC, M/F User Æ Switch IF Interface 4-2 See  Sect.  4.2.2  and  Figure  4‐1  in  this  chapter  for  details  of  the  CDM‐625  Modem‐to‐Switch Control Interface connection, and Sect. 4.2.3 and for details of the CDM‐625 Modem‐to‐Switch IF Interface connections. These figures illustrate how to connect a pair of CDM‐625 modems together  with  the  CRS‐180  70/140  MHz  IF  1:1  Redundancy  Switch  module;  the  table  that accompanies each figure lists the cables provided in KT‐0000159 for this initial setup.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–4 4.2.2 Modem-to-Switch Control Interface Connection When connecting the Control cable between the CRS‐180 and the modems, ensure that screw locks on the ‘D’ type connectors are securely fastened. This will prevent the accidental unmating of the cable, particularly when a standby unit is being removed or replaced. CEFD Part No. Qty Description CA/WR9378-4 2 Control Cable – Universal, DB-9M, 4’ Figure 4-1. CDM-625 Modem-to-Switch Control Connections

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–5 4.2.3 Modem-to-Switch IF Interface Connection EXAMPLE: The Tx IF from ‘ Modem A’ connects to the Tx IF port ‘J5 | Tx A’ on the CRS‐180; similarly, the Tx IF from ‘Modem B’ connects to the Tx IF port ‘J6 | Tx B’ on the CRS‐180. The same logic applies for the Rx IF connections. It is important to note that failure to observe this requirement will result in system malfunction. Item CEFD Part No. Qty Description 1 PL/0946-1 4 IF Coax Cable, 50Ω 2 XF/BNC-MF-50-75 2 Transformer, 50-75Ω, 2-200 MHz, BNC, M/F Figure 4-2. CDM-625 Modem-to-Switch 70/140 MHz IF Connections Modem‐to‐Switch IF Connection Notes: 1. Excluding modems, all components depicted in Figure 4‐1 are provided in the KT‐0000159 CDM‐ 625 70/140 MHz IF 1:1 Redundancy Kit (see Sect. 4.2.1). 2. 50‐75Ω transformers (Item 2) are required on the Rx (J7) and Tx (J8) connectors, located on the antenna side of the switch, when the user supplies a 75Ω Rx/Tx connection.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–6 4.2.4 Modem-to-User Data Interface Connections and Examples The data cables and components identified in each of the examples that follow in this section must be purchased separately, as required. In addition to the control and IF switch‐to‐modem cabling shown previously, a number of data interface configurations are available for the CDM‐625. The block diagram shown in Figure 4‐3 is typical for the examples shown in Sects. 4.2.4.1 through 4.2.4.8. With the exception of the 10/100 Ethernet Interface configuration shown in Figure 4‐12, where customer‐supplied Ethernet cables and Layer 2 switches are used, one cable/component set per 1:1 modem pair is required for each user interface (see examples for specified quantities). Figure 4-3. CDM-625 Block Diagram: User Æ Modem Æ Switch Æ Traffic

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–7 4.2.4.1 RS-422/232 Interface Example CEFD Part No. Qty Description CA/RB10461-1 1 Cable – 1:1 ‘Y’ Splitter, (2X) DB-25M Æ DB-25F Figure 4-4. CDM-625 RS-422/232 1:1 Example 4.2.4.2 HSSI Interface Example CEFD Part No. Qty Description CA/RB10461-1 1 Cable – 1:1 ‘Y’ Splitter, (2X) DB-25M Æ DB-25F PL-0000307 1 CIC-60 – Interconnect Converter, DB-25M Æ HD-50F (SCSI-II) Figure 4-5. CDM-625 HSSI 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–8 4.2.4.3 ASI Interface Example KT/12579 ASI 75Ω Interface Kit CEFD Part No. Qty Description CA/BNC75OHM 4 Cable – IF BNC, 75Ω, 1’ RF/SA32KC-IN/OUT 2 Combiner – 2-way w/Bracket, 0.25-300 MHz, 75Ω BNC Figure 4-6. CDM-625 ASI 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–9 4.2.4.4 Quad E1 Interface Example The  G.703  Balanced  and  Auxiliary  G.703  DB‐9F  single  connectors  are  used  for  Quad  E1 operation. Note the following: 1. As shown in Figure 4‐7, the CA‐0000071 ‘Y’ Cable provides for two ports of E1 (i.e., Ports 1/2 ‐or‐ Ports 3/4). 2. If the user desires three or four separate ports of E1 (i.e., Port 1 and Port 2 ‐or‐ Port 3 and Port 4), then optional adapter cables may be purchased from Comtech EF Data to adapt the G.703  Balanced  and  Auxiliary  G.703  DB‐9F  single  connector  pairs  to  outgoing  Quad  E1 connector pairs as follows: Cable (CEFD Part No.) Converts (1) 9-pin Type ‘D’ (DB-9F) paired connection (e.g., Modem A AND Modem B G.703 Balanced connector pair –or– Modem A AND Modem B Auxiliary G.703 connector pair) to: See App. A Fig. CA-0000163 (2) 15-pin Type ‘D’ (DB-15F) connectors A-9 CA-0000164 (2) RJ-48 female connectors A-10 KT-0000122 (4) BNC 75Ω female connectors – (2) Tx, (2) Rx A-11 All three cabling options plug into the single ‘To User’ connector side of each CA‐0000071 ‘Y’ Splitter cable used. Figure 4-7. CDM-625 Quad E1 1:1 Example CEFD Part No. Qty Description CA-0000071 2 Note 1 Cable – 1:1 ‘Y’ Splitter, (2X) DB-9M Æ DB-9F, 8”

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–10 4.2.4.5 G.703 Balanced Interface Example CEFD Part No. Qty Description CA-0000071 1 Cable – 1:1 ‘Y’ Splitter, (2X) DB-9M Æ DB-9F, 8” Figure 4-8. CDM-625 G.703 Balanced 1:1 Example 4.2.4.6 G.703 Unbalanced Interface Example KT/10553-1 G.703 Unbalanced Interface Kit CEFD Part No. Qty Description CA/BNC75OHM 4 Cable – IF BNC, 1’ CN/BNC-TEE-JPJ 2 T-Adapter, 50Ω BNC Figure 4-9. CDM-625 G.703 Unbalanced 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–11 4.2.4.7 Overhead Interface Example CEFD Part No. Qty Description CA-0000070 1 Cable – 1:1 ‘Y’ Splitter, (2X) HD-44M Æ HD-44F, 8” Figure 4-10. CDM-625 Overhead 1:1 Example 4.2.4.8 Engineering Service Channel (ESC) Interface Example CEFD Part No. Qty Description CA-0000071 1 Cable – 1:1 ‘Y’ Splitter, (2X) DB-9M Æ DB-9F, 8” Figure 4-11. CDM-625 ESC 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–12 4.2.4.9 10/100 Ethernet Interface Examples 4.2.4.9.1 Managed Switch Mode (with/without IP Packet Processor) Figure 4‐12 shows a block diagram and cabling example of a CDM‐625 1:1 modem configuration using the 10/100 Ethernet Interface in Managed Switch (Ethernet Bridge) Mode. Direct connection is made via one to four RJ‐45 ports using user‐provided Ethernet cables and Layer 2 switches, so no cables or kit is required. The cabling example depicts all four Ethernet ports used. CDM-625 Block Diagram: 10/100 Ethernet Interface – Managed Switch Mode Figure 4-12. CDM-625 10/100 Ethernet 1:1 Example – Managed Switch Mode

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–13 4.2.4.9.2 Router Mode (Optional IP Packet Processor Required) Figure 4‐13 shows a block diagram and cabling example of a CDM‐625 1:1 modem configuration using  the  10/100  Ethernet  Interface  in  Router  Mode,  with  the  optional  IP  Packet  Processor installed  and  enabled.  Direct  connection  is  made  via  only  one  of  four  RJ‐45  ports  using  user‐ provided Ethernet cables and a Layer 2 switch, so no cables or kit is required. CDM-625 Block Diagram: 10/100 Ethernet Interface – Router Mode Figure 4-13. CDM-625 10/100 Ethernet 1:1 Example – Router Mode

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–14 4.2.4.9.3 Data Interface Connections using IP Sub-Mux Chapter 15. IP SUB‐MUX in CDM‐625 Advanced Satellite Modem Installation and Operation Manual (CEFD P/N MN‐CDM625) Sub‐Mux is a secondary framing structure which combines one to four ports of 10/100 Ethernet (IP) traffic – as shown in Figure 4‐12 – with any currently available combination of framing and interface type (excluding IP itself) – as shown in Figure 4‐4 through Figure 4‐11. The composite data rate to the modulator and from the demodulator is referenced to the primary, non‐IP data interface rate by a specific ratio selected by the user. 4.2.4.10 PMSI Interface Example The  Pre‐Mapped  Symbol  Interface  (PMSI)  is  a  function  associated  with  DoubleTalk®  Carrier‐in‐ Carrier® (CnC®) that permits the modulator in a selected unit to provide a direct copy of its output (the outbound interferer) to the offline modem in a 1:1 pair. The offline modem will then take the PMSI signal and use it for its own CnC® reference. The PMSI is an RS‐485 point‐to‐point bus system where one device transmits, and the other device on the bus is configured to receive. See Figure 4‐14 to connect and secure the CDM‐625 Multi‐drop CnC® Plus 1:1 Cable CA‐0000276 (2X DB‐ 9M, 1’), required between the Redundant Modem and each Traffic Modem using CnC. The CA-0000276 Multi-Drop CnC PLUS 1:1 Cable bypasses the CRS-180 70/140 MHz IF 1:1 Redundancy Switch. If  CnC®  is  enabled  with  a  CDM‐625  1:1  pair,  before  any  switch  configurations  can  be  made, specific configuration steps must be taken with each CDM‐625 to ensure proper operation of the pair within a configured CRS‐180 1:1 Redundancy System. Chapter 3. MODEM AND SWITCH CONFIGURATION CEFD Part No. Qty Description CA-0000276 1 CDM-625 Data Cable – Shielded, Multi-drop CnC® Plus, 1:1, (2X) DB-9M, 1’ Figure 4-14. CDM-625 PMSI 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–15 4.3 Cabling to the CDM-750 1. For information on the CDM‐750’s  1:1  auto‐enable functionality, see: • Chapter 3. MODEM AND SWITCH CONFIGURATION • CDM‐750 Advanced High‐Speed Trunking Modem Installation and Operation Manual (CEFD P/N MN‐CDM750) 2. For information on the cables and cable assemblies specified in this section, see: • Appendix A. CABLE DRAWINGS 4.3.1 Modem-to-Switch Control and IF Interface Connection Figure 4‐15 shows the control and IF connections for the CDM‐750 to the CRS‐180. All control and IF  components  are  provided  for  the  CDM‐750  in  the  KT‐0000188  CRS‐180  70/140  MHz  IF  1:1 Redundancy Kit. Note the following: 1. Use of the XF/BNC‐MF‐50‐75 transformers (Item 2) on the antenna side Rx (J7) and Tx (J8) connectors are required only when the user supplies a 75Ω Rx/Tx antenna connection. 2. Use of the XF/BNC‐MF‐50‐75 transformers (Item 2) on the switch‐to‐modem side Rx (J1, J2) and Tx (J5, J6) connectors are always required in order to accommodate the CDM‐750’s 75Ω Rx/Tx operability.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–16 KT-0000177 70/140 MHz IF 1:1 Redundancy Kit (CRS-180 Æ CDM-750) Item CEFD Part No. Qty Description 1 PL/11560-1 1 Top Assy, CRS-180 70/140 MHz IF 1:1 Redundancy Switch 2 XF/BNC-MF-50-75 (Notes 1,2) 6 Transformer, 50-75Ω, 2-200 MHz, BNC, M/F 3 CA/WR9378-4 2 Control Cable, Universal, DB-9M, 4’ 4 PL/0813-4 4 Cable, Special, 75Ω IF BNC, 4’ Figure 4-15. CDM-750 Modem-to-Switch Control & IF Connections – KT-0000160

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–17 4.3.2 Modem-to-User Data Interface Connections and Examples In  addition  to  the  control  and  IF  switch‐to‐modem  cabling  shown  in  the  previous  section,  a number of data interface configuration kits are available for use with the CDM‐750. 4.3.2.1 RJ-45 Gigabit Ethernet Data Interface Example When  no  optional  data  interfaces  are  installed  via  the  available  J7  Optical  port  or  Plug‐In Interface Card (PIIC) slots, by default the CDM‐750 provides a 10/100 Ethernet data interface via two copper RJ‐45 Gigbabit Ethernet  (also referred to as GigE or GbE) Interface ports. Figure 4‐16 shows a block diagram and cabling example of a CDM‐750 1:1 modem configuration using these RJ‐45 ports (this example depicts use of both ports). Direct connection is made with user‐provided Ethernet cables and Layer 2 switches, so no cables or kit is required. CDM-750 Block Diagram: 10/100 Ethernet Interface Figure 4-16. CDM-750 RJ-45 Gigabit Ethernet 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–18 4.3.2.2 Optical Gigabit Ethernet Interface Option Example Figure 4‐17 depicts a CDM‐750 1:1 modem configuration using the FAST‐activated J7 Optical SFP port and optional Optical Gigabit Ethernet Interface module (CEFD P/N IC‐0000058). Depending on the mode – Single Mode or Multi Mode – installation involves use of either one CA‐0000560 Optical Single‐Mode Y‐Cable set, or one CA‐0000559 Multi‐Mode Y‐Cable set.  Mode configuration is  easily distinguished  by  the  color of  the  cables; for Single‐Mode  configurations, yellow cabling is used by the CA‐0000560 ‘Y’ Cable, whereas a Multi‐Mode configuration using the CA‐0000559 ‘Y’ Cable features orange cabling. Type LC sockets, part of optional IC-0000058 SFP Module, typical for Single-Mode or Multi-Mode Optical Gigabit Ethernet: CEFD Part No. Qty Description CA-0000560 1 ‘Y’ Cable Assy – RoHS-Compliant, Single-Mode Optical, LC Connectors -OR- CEFD Part No. Qty Description CA-0000559 1 Y’ Cable Assy – RoHS-Compliant, Multi-Mode ‘Optical, LC Connectors Figure 4-17. CDM-750 Optical Gigabit Ethernet 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–19 4.3.2.3 Serial Data Interface Kit and Connection Examples For all CDM‐750 serial data interface configurations, separate cabling kits are needed. For each user  interface,  one  interface  kit  per  1:1  modem  pair  is  required  (see  examples  for  specified quantities). For example, Sect. 4.3.2.3.1 identifies the interface kit used for the G.703 PIIC data interface. Figure  4‐18  shows  a  block  diagram  typical  for  the  kits  shown  in  this  section.  Note  that  this cabling diagram is not applicable to the standard Gigabit Ethernet Data Interface configuration – as shown in Sect. 4.3.2.1 and Figure 4‐17, user‐provided Ethernet cables and Layer 2 Switches are used. Figure 4-18. CDM-750 Block Diagram: User Æ Modem Æ Switch Æ Traffic Note that, while data interface cards may be installed into both Interface Option slots, only one interface is operable at a given time. The following table outlines the data interface operating combinations allowable in Interface Option slots 1 and 2 of the CDM‐750 chassis: Allowable CDM-750 Interface Operating Combinations PIIC Slot 1 PIIC Slot 2 G.703 E3/T3 None None G.703 E3/T3

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–20 4.3.2.3.1 KT/12542 Single G.703 E3/T3 75Ω (PIIC) Interface Kit KT/12542 Single G.703 E3/T3 75Ω Interface Cabling Kit (G.703 E3/T3 75Ω PIIC) CEFD Part No. Qty Description CA/BNC75OHM 4 Cable – IF, BNC 75Ω, 1’ RF/SA32KC-IN/OUT 2 Combiner – 2-Way w/Bracket, 0.25-300 MHz, BNC 75Ω Figure 4-19. CDM-750 G.703 E3/T3 PIIC Interface Kit – KT/12542

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–21 4.4 Cabling to the CDM-570 1. For information on the CDM‐570’s  1:1 auto‐enable functionality, see: • Chapter 3. MODEM AND SWITCH CONFIGURATION • CDM‐570/CDM‐570L/CDMR‐570L Satellite Modem Installation and Operation Manual (CEFD P/N MN/CDM570L.IOM) 2. For information on the cables and cable assemblies specified in this section, see: • Appendix A. CABLE DRAWINGS 4.4.1 CRS-180 Æ CDM-570 1:1 Redundancy Kit KT/11599 Reference to how the items provided in Redundancy Kit KT/11599 are used with all possible CDM‐570 data interface configurations is as follows: KT/11559 1:1 Redundancy Control/IF Interface Cabling Kit (CRS-180 Æ CDM-570) CEFD Part No. Qty/Kit (REF) Description Used For Ch. 4 Fig PL/11560-1 1 CRS-180 Switch – Top Assembly 1:1 Redundancy 4-19 4-20 PL/0946-1 4 IF (Tx/Rx) Coax Cable, 50Ω Type ‘BNC’, 4’ Modem Æ Switch IF Interface 4-20 CA/WR9378-4 2 Control Cable – Universal, DB-9M Æ DB-9M, 4’ Modem Æ Switch Control 4-20 XF/BNC-MF-50-75 2 Transformer, 50-75Ω, 2-200 MHz, BNC, M/F User IF Tx/Rx Interface 4-20 CA/RB10461-1 1 Cable – 1:1 Y-Splitter, (2X) DB-25M Æ DB-25F RS-422/232 Interface 4-22 CA/WR10522-1 1 Cable – 1:1 Y-Splitter, (2X) DB-15M Æ DB-15F G.703 Balanced 4-23 KT/10553-1 1 G.703 Unbalanced Interface Kit containing: (Qty 4) CA/BNC75OHM Cable – IF BNC, 1’ (Qty 2) CN/BNC-Tee-JPJ T-Adapter, 50Ω BNC G.703 Unbalanced 4-24 Figure 4‐20 and Figure 4‐21 show how to connect a pair of CDM‐570 modems together with the CRS‐180 70/140 MHz IF 1:1 Redundancy Switch module; the table for each figure lists the cable assemblies provided in KT/11559 for this initial setup. It is essential to ensure that the control and IF connections, both Rx and Tx, are made correctly. See  Sect.  4.4.2  in  this  chapter  for  details  of  the  CDM‐570  Modem‐to‐Switch  Control  Interface connection; Sect. 4.4.3 for details of the CDM‐570 Modem‐to‐Switch IF Interface connection; and Sect. 4.4.4 for details of the CDM‐570 data interface configurations.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–22 4.4.2 Modem-to-Switch Control Interface Connection When connecting the Control cable between the CRS‐180 and the modems, ensure that screw locks on the ‘D’ type connectors are securely fastened. This will prevent the accidental unmating of the cable, particularly when a standby unit is being removed or replaced. CEFD Part No. Qty Description CA/WR9378-4 2 Control Cable – Universal, DB-9M, 4’ Figure 4-20. CDM-570 Modem-to-Switch Control Connections

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–23 4.4.3 Modem-to-Switch IF Interface Connection Item CEFD Part No. Qty Description 1 PL/0946-1 4 IF Coax Cable, 50Ω 2 XF/BNC-MF-50-75 2 Transformer, 50-75Ω, 2-200 MHz, BNC, M/F Figure 4-21. CDM-570 Modem-to-Switch 70/140 MHz IF Connections Modem‐to‐Switch IF Connection Notes: 1. Excluding  modems,  all  components  depicted  in  Figure  4‐21  are  provided  in  the  KT/11559 CDM‐570 70/140 MHz IF 1:1 Redundancy Kit (see Sect. 4.4.1). 2. 50‐75Ω transformers (Item 2) are required on the Rx (J7) and Tx (J8) connectors, located on the antenna side of the switch, when the user supplies a 75Ω Rx/Tx connection. EXAMPLE: The Tx IF from ‘ Modem A’ connects to the Tx IF port ‘J5 | Tx A’ on the CRS‐180; similarly, the Tx IF from ‘Modem B’ connects to the Tx IF port ‘J6| Tx B’ on the CRS‐180. The same logic applies for the Rx IF connections. It is important to note that failure to observe this requirement will result in system malfunction.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–24 4.4.4 Modem-to-User Data Interface Connections and Examples In addition to the control and IF switch‐to‐modem cabling shown previously, a number of data interface configurations are available for the CDM‐570. The block diagram shown in Figure 4‐22 is typical for the examples shown in Sects. 4.4.4.1 through 4.4.4.3. With the exception of the 10/100 Ethernet Interface configuration shown in Sect. 4.4.4.4, where user‐provided Ethernet cables and hub are used, one cable/component set per 1:1 modem pair is required  for each user interface (see examples for specified quantities). Figure 4-22. CDM-570 Block Diagram: User Æ Modem Æ Switch Æ Traffic Unless otherwise specified, the interface cables and components identified in each of the examples that follow are provided in the KT/11559 CDM‐570 1:1 Redundancy Kit (see Sect. 4.4.1).

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–25 4.4.4.1 RS-422/232 Interface Example CEFD Part No. Qty Description CA/RB10461-1 1 Cable – 1:1 ‘Y’ Splitter, (2X) DB-25M Æ DB-25F Figure 4-23. CDM-570 RS-422/232 1:1 Example 4.4.4.2 G.703 Balanced Interface Example CEFD Part No. Qty Description CA/WR10522-1 1 Cable – 1:1 ‘Y’ Splitter, (2X) DB-15M Æ DB-15F Figure 4-24. CDM-570 G.703 Balanced 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–26 4.4.4.3 G.703 Unbalanced Interface Example G.703 Unbalanced 1:1 Interface Kit KT/10553-1 CEFD Part No. Qty Description CA/BNC75OHM 4 Cable – IF BNC, 1’ CN/BNC-TEE-JPJ 2 T-Adapter, 50Ω BNC Figure 4-25. CDM-570 G.703 Unbalanced 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–27 4.4.4.4 10/100 Ethernet Interface Example Figure 4‐26 shows a block diagram and cabling example of a CDM‐570 1:1 modem configuration using the 10/100 Ethernet Interface. User‐provided Ethernet cables are connected directly to the ports, so no cables or kit is required. For the CDM‐570 in Managed Switch (Ethernet Bridge) Mode, the user MUST use an external  Ethernet  hub  to  insure  that  traffic  will  continue  after  a  switchover.  If  an Ethernet switch is used, there could be a several minute outage while the Ethernet Switch  “re‐learns”  the  correct  output  Ethernet  port.  Using  a  “dumb”  Ethernet  hub allows  LAN  to  WAN  traffic  to  continue  even  after  a  switchover  occurs  since  both modems will be receiving the LAN traffic. CDM-570 Block Diagram: 10/100 Ethernet Interface Figure 4-26. CDM-570 10/100 Ethernet 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–28 Notes:

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–29 4.5 Cabling to the CDM-700 1. For information on configuring the CRS‐180 70/140 MHz IF 1:1 Redundancy Switch with the CDM‐700 Satellite Modems for 1:1 operation, see: • Chapter 3. MODEM AND SWITCH CONFIGURATION • CDM‐700 Satellite Modem Installation and Operation Manual (CEFD P/N MN/CDM700.IOM) 2. For information on the cables and cable assemblies specified in this section, see: • Appendix A. CABLE DRAWINGS 4.5.1 Modem-to-Switch Control and IF Interface Connection Figure 4‐27 shows the control and IF connections for the CDM‐700 to the CRS‐180. All control and IF components are provided in the KT/12554 CRS‐180 70/140 MHz IF 1:1 Redundancy Kit (terrestrial  data  interface  components/kits  must  be  ordered  separately  –  see  Sect.  4.5.2  for more information). Note the following: 1. Use of the XF/BNC‐MF‐50‐75 transformers (Item 2) is required on the Rx (J7) and Tx (J8) connectors, located on the antenna side of the switch, when the user supplies a 75Ω Rx/Tx connection. 2. Use of the XF/BNC‐MF‐50‐75 transformers (Item 2) on the Rx A and Rx B ports, located on the modem side of the switch, is dependent on the CDM‐700’s factory configuration for 50Ω or  75Ω  Rx  operability.  If  the  modems  in  use  are  configured  as  50Ω  Rx  units,  the transformers will not be used on the Rx side and the 50Ω cable (Item 4) will be used in place of the 75Ω cable (Item 3). 3. To provide User access to modem “Fault Summary Relay,” Control ‘Y’ Cable CA/WR13011‐4, sold separately, is available for use in place of the CA/WR12135‐1 cable. 4. Control Cable CA/WR12135‐1 will mute the Offline modem’s Tx IF. If this is not desired, then an alternate cable, Control Cable CA‐0000187, sold separately, is available for use in place of the CA/WR12135‐1 cable.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–30 KT/12554 70/140 MHz IF 1:1 Redundancy Kit Item CEFD Part No. Qty Description 1 PL/11560-1 1 Top Assy, CRS-180 70/140 MHz IF 1:1 Redundancy Switch 2 XF/BNC-MF-50-75 (Notes 1,2) 4 Transformer, 50-75Ω, 2-200 MHz, BNC, M/F 3 PL/0813-4 (Note 2) 2 Cable, Special, IF BNC, 75Ω 4 PL/0946-1 (Note 2) 4 Cable, Special, IF BNC, 50Ω 5 CA/WR12135-1 (Notes 3, 4) 2 Cable Assy, Control Adapter RoHS-Compliant Figure 4-27. CDM-700 Modem-to-Switch Control & IF Connections – KT/12554

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–31 4.5.2 Modem-to-User Data Interface Kits and Connection Examples In  addition  to  the  control  and  IF  switch‐to‐modem  cabling  shown  in  the  previous  section,  a number of data interface configurations are available for use with the CDM‐700. The kits featured in this section can be supplied with the CRS‐180 for use with the CDM‐700. Figure 4-28. CDM-700 Block Diagram: User Æ Modem Æ Switch Æ Traffic Figure 4‐28 shows a block diagram typical for the kits shown in Sects. 4.5.2.1 through 4.5.2.3. Separate interface cabling kits are needed for these CDM‐700 data interfaces. For example, Sect. 4.5.2.1 identifies the interface kits used for the CDI‐10 Dual G.703 E3/T3/STS‐1 and the CDI‐60 HSSI Data Interfaces. With the exception of the CDI‐70 Gigabit Ethernet Data Interface configuration shown in Sect. 4.5.2.4, where user‐provided Ethernet cables and Layer 2 Switch are used, one interface kit per 1:1 modem pair is required for each user interface (see examples for specified quantities). The data interface combinations allowable in Interface Slots 1 and 2 of the CDM‐700 chassis are as follows: Allowable CDM-700 Combinations Interface Slot 1 Interface Slot 2 Dual G.703 (CDI-10) None Dual G.703 (CDI-10) HSSI (CDI-60) GigE (CDI-70) OC3 Optical (CDI-50-1) Single Mode None OC3 Copper (CDI-50-1) None HSSI (CDI-60) None HSSI (CDI-60 GigE (CDI-70) GigE (CDI-70) None GigE (CDI-70) None Dual G.703 (CDI-10) HSSI (CDI-60) GigE (CDI-70)

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–32 4.5.2.1 Dual G.703 E3/T3/STS-1 75Ω Data Interface (CDI-10) Kit KT/12542 and HSSI Data Interface (CDI-60) Kit KT/12578 Figure 4‐29 shows an example of a CDM‐700 1:1 modem configuration with the CDI‐10 Dual G.703 Data Interface installed in Slot 1, and the CDI‐60 HSSI Data Interface installed in Slot 2. The figure depicts installation of one KT/12542 Dual G.703 Interface Kit (each kit can supply one or two CDI‐10 interfaces), and one KT/12578 HSSI Interface Kit. KT/12542 G.703 (CDI-10) 75Ω Interface Kit CEFD Part No. Qty Description CA/BNC75OHM 8 Cable – IF BNC, 75Ω, 1’ RF/SA32KC-IN/OUT 4 Combiner – 2-way w/Bracket, 0.25-300 MHz, 75Ω BNC KT/12578 HSSI (CDI-60) Interface Kit CEFD Part No. Qty Description PP/SC3523 1 Cable - RoHS-Compliant, HSSI ‘Y’ Splitter, (2X) HD-50M Æ HD-50F, 3” Figure 4-29. CDM-700 G.703 E3/T3/STS-1 and HSSI 1:1 Example To/From User To User From User

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–33 4.5.2.2 155MB Copper Data Interface (CDI-50) Kit KT/12579 Figure  4‐30  shows  an  example  of  a  CDM‐700  1:1  modem  configuration  with  a  CDI‐50  Data Interface  installed  in  Slot  1  for  use  with  155MB  Copper  data,  and  Slot  2  empty.  The  figure depicts installation of one KT/12579 155MB Copper Interface Kit – each kit can supply one or two CDI‐50 interfaces. KT/12579 155MB Copper (CDI-50) Interface Kit CEFD Part No. Qty Description CA/BNC75OHM 4 Cable – IF BNC, 75Ω, 1’ RF/SA32KC-IN/OUT 2 Combiner – 2-way w/Bracket, 0.25-300 MHz, 75Ω BNC Figure 4-30. CDM-700 155MB Copper 1:1 Example To User From User

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–34 4.5.2.3 OC-3 Data Interface (CDI-50) Kits KT/12580 (Single-Mode) or KT/12581 (Multi-Mode) Figure  4‐31  depicts  a  CDM‐700  1:1  modem  configuration  with  installation  of  one  CDI‐50  Data Interface installed in Slot 1 for use with OC‐3 data, and Slot 2 empty. The figure depicts installation of one KT/12580 OC‐3 Single‐Mode  Interface Kit. Multi‐Mode configurations  use  the KT/12581 OC‐3 Multi‐Mode Interface kit. Mode configuration is easily distinguished by the color of the cables included in the kit; for Single‐ Mode  configurations,  yellow  cabling  is  used  as  shown  in  Figure  4‐31,  whereas  a  Multi‐Mode configuration (not shown) features orange cabling. KT/12580 OC-3 Single-Mode (CDI-50) Interface Kit CEFD Part No. Qty Description PP/CPS2A12501 2 Cable Assy – RoHS-Compliant, Optical Coupler, SC/UPC Connectors OR KT/12581 OC-3 Multi-Mode (CDI-50) Interface Kit CEFD Part No. Qty Description PP/CPM6A1250 2 Cable Assy – RoHS-Compliant, Optical Coupler, SC/UPC Connectors Figure 4-31. CDM-700 OC-3 1:1 Example (Single-Mode shown)

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–35 4.5.2.4 Gigabit Ethernet Data Interface (CDI-70) Example See CEFD White Paper “Bridged Ethernet Interface Redundancy” available for download from Comtech EF Data’s Web site (www.comtechefdata.com). Figure  4‐32  shows  an  example  of  a  CDM‐700  1:1  modem  configuration  with  a  CDI‐70  Gigabit Ethernet  Data  Interface  installed  in  Slot  1,  and  Slot  2  empty.  User‐provided  Ethernet  cables  are connected directly to the interface, so no kit is required. CDM-700 Block Diagram: Gigabit Ethernet (GigE) Interface Figure 4-32. CDM-700 Gigabit Ethernet (GigE) 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–36 Notes:

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–37 4.6 Cabling to the CDM-710 1. For information on configuring the CRS‐180 70/140 MHz 1:1 Redundancy Switch with the CDM‐710 Broadcast Satellite Modems for 1:1 operation, see: • Chapter 3. MODEM AND SWITCH CONFIGURATION • CDM‐710 Broadcast Satellite Modem Installation and Operation Manual (CEFD P/N MN/CDM710.IOM) 2. For information on the cables and cable assemblies specified in this section, see: • Appendix A. CABLE DRAWINGS 4.6.1 Modem-to-Switch Control and IF Interface Connection Figure 4‐33 shows the control and IF connections for the CDM‐710 to the CRS‐180. All IF and control components are provided in the KT/12554 CRS‐180 70/140 MHz IF 1:1 Redundancy Kit (terrestrial data interface components/kits must be ordered separately). Note the following: 1. Use of the XF/BNC‐MF‐50‐75 transformers (Item 2) is required on the Rx (J7) and Tx (J8) connectors, located on the antenna side of the switch, when the user supplies a 75Ω Rx/Tx connection. 2. Use of the XF/BNC‐MF‐50‐75 transformers (Item 2) on the Rx A and Rx B ports, located on the modem side of the switch, is dependent on the CDM‐710’s factory configuration for 50Ω or  75Ω  Rx  operability.  If  the  modems  in  use  are  configured  as  50Ω  Rx  units,  the transformers will not be used on the Rx side and the 50Ω cable (Item 4) will be used in place of the 75Ω cable (Item 3). 3. To provide User access to modem “Fault Summary Relay,” Control ‘Y’ Cable CA/WR13011‐4, sold separately, is available for use in place of the CA/WR12135‐1 cable. 4. Control Cable CA/WR12135‐1 will mute the Offline modem’s Tx IF. If this is not desired, then an alternate cable, Control Cable CA‐0000187, sold separately, is available for use in place of the CA/WR12135‐1 cable.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–38 KT/12554 70/140 MHz IF 1:1 Redundancy Kit Item CEFD Part No. Qty Description 1 PL/11560-1 1 Top Assy, CRS-180 70/140 MHz IF 1:1 Redundancy Switch 2 XF/BNC-MF-50-75 (Notes 1,2) 4 Transformer, 50-75Ω, 2-200 MHz, BNC, M/F 3 PL/0813-4 (Note 2) 2 Cable, Special, IF BNC, 75Ω 4 PL/0946-1 (Note 2) 4 Cable, Special, IF BNC, 50Ω 5 CA/WR12135-1 (Notes 3, 4) 2 Cable Assy, Control Adapter RoHS-Compliant Figure 4-33. CDM-710 Modem-to-Switch Control & IF Connections – KT/12554

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–39 4.6.2 Modem-to-User Data Interface Kit and Connection Examples In  addition  to  the  control  and  IF  switch‐to‐modem  cabling  shown  in  the  previous  section,  a number of data interface configuration kits are available for use with the CDM‐710. Figure 4-34. CDM-710 Block Diagram: User Æ Modem Æ Switch Æ Traffic Figure  4‐34 shows  a  block  diagram  typical  for  the  kits  shown  in  Sects.  4.6.2.1  and  4.6.2.2. Separate cabling kits are needed for these CDM‐710 data interfaces. For example, Sect. 4.6.2.1 identifies the interface kit used for the CDI‐40 ASI Data Interface. With the exception of the CDI‐70 Gigabit  Ethernet  Data  Interface  configuration  shown  in  Sect.  4.6.2.3,  where  user‐provided Ethernet cables and Layer 2 Switch are used, one interface kit per 1:1 modem pair is required for each user interface (see examples for specified quantities). The data interface combinations allowable in Interface Slots 1 and 2 of the CDM‐710 chassis are as follows: Allowable CDM-710 Combinations Interface Slot 1 Interface Slot 2 ASI (CDI-40) None HSSI (CDI-60) None None GbE (CDI-70)

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–40 4.6.2.1 ASI 75Ω Data Interface (CDI-40) Kit KT/12579 Figure 4‐35 shows an example of a CDM‐710 1:1 modem configuration with the CDI‐40 ASI Data Interface installed in Slot 1, and Slot 2 empty. The figure depicts installation of one KT/12579 ASI Interface Kit. Be sure to connect to the lower BNC connectors labeled “1:1” on the CDI-40 ASI Data Interface. The Rx port on each interface has been tuned to be 3 dB higher amplitude to compensate for the presence of the RF/SA32KC-IN/OUT 2-way combiner. KT/12579 ASI (CDI-40) 75Ω Interface Kit CEFD Part No. Qty Description CA/BNC75OHM 4 Cable – IF BNC, 75Ω, 1’ RF/SA32KC-IN/OUT 2 Combiner – 2-way w/Bracket, 0.25-300 MHz, 75Ω BNC Figure 4-35. CDM-710 ASI 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–41 4.6.2.2 HSSI Data Interface (CDI-60) Interface Kit KT/12578 Figure 4‐36 shows an example of a CDM‐710 1:1 modem configuration with the CDI‐60 HSSI Data  Interface  installed  in  Slot  1,  and  Slot  2  empty.  The  figure  depicts  installation  of  one KT/12578 HSSI Interface Kit. KT/12578 HSSI (CDI-60) Interface Kit CEFD Part No. Qty Description PP/SC3523 1 Cable - RoHS-Compliant, HSSI ‘Y’ Splitter, (2X) HD-50M Æ HD-50F, 3” Figure 4-36. CDM-710 HSSI 1:1 Example To/From User

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–42 4.6.2.3 Gigabit Ethernet Data Interface (CDI-70) Example See CEFD White Paper “Bridged Ethernet Interface Redundancy” available for download from Comtech EF Data’s Web site (www.comtechefdata.com). Figure 4‐37 shows a block diagram and cabling example of a CDM‐710 1:1 modem configuration with a CDI‐70 Gigabit Ethernet Data Interface in Slot 2, and Slot 1 empty. User‐provided Ethernet cables are connected directly to the interface, so no kit is required. CDM-710 Gigabit Ethernet (GigE) Interface – Block Diagram Figure 4-37. CDM-710 Gigabit Ethernet (GigE) 1:1 Example

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–43 4.7 Cabling to the CDM-710G 1. For information on configuring the CRS‐180 70/140 MHz 1:1 Redundancy Switch with the CDM‐710 Broadcast Satellite Modems for 1:1 operation, see: • Chapter 3. MODEM AND SWITCH CONFIGURATION • CDM‐710G High‐Speed Satellite Modem Installation and Operation Manual (CEFD P/N MN‐CDM710G.IOM) 2. For information on the cables and cable assemblies specified in this section, see: Appendix A. CABLE DRAWINGS 4.7.1 Modem-to-Switch Control and IF Interface Connection Figure 4‐38 shows the control and IF connections for the CDM‐710G to the CRS‐180. As with the CDM‐710,  all  control  and  IF  components  are  provided  for  the  CDM‐710G  in  the  KT/12554 CRS‐180 70/140 MHz IF 1:1 Redundancy Kit (terrestrial data interface components/kits must be ordered separately). Note the following: 1. Use of the XF/BNC‐MF‐50‐75 transformers (Item 2) is required on the Rx (J7) and Tx (J8) connectors, located on the antenna side of the switch, when the user supplies a 75Ω Rx/Tx connection. 2. Use of the XF/BNC‐MF‐50‐75 transformers (Item 2) on the Rx A and Rx B ports, located on the modem side of the switch, is dependent on the CDM‐710G’s factory configuration for 50Ω  or  75Ω  Rx  operability.  If  the  modems  in  use  are  configured  as  50Ω  Rx  units,  the transformers will not be used on the Rx side and the 50Ω cable (Item 4) will be used in place of the 75Ω cable (Item 3). 3. To provide User access to modem “Fault Summary Relay,” Control ‘Y’ Cable CA/WR13011‐4, sold separately, is available for use in place of the CA/WR12135‐1 cable. 4. Control Cable CA/WR12135‐1 will mute the Offline modem’s Tx IF. If this is not desired, then an alternate cable, Control Cable CA‐0000187, sold separately, is available for use in place of the CA/WR12135‐1 cable.

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–44 KT/12554 70/140 MHz IF 1:1 Redundancy Kit Item CEFD Part No. Qty Description 1 PL/11560-1 1 Top Assy, CRS-180 70/140 MHz IF 1:1 Redundancy Switch 2 XF/BNC-MF-50-75 (Notes 1,2) 4 Transformer, 50-75Ω, 2-200 MHz, BNC, M/F 3 PL/0813-4 (Note 2) 2 Cable, Special, IF BNC, 75Ω 4 PL/0946-1 (Note 2) 4 Cable, Special, IF BNC, 50Ω 5 CA/WR12135-1 (Notes 3,4) 2 Cable Assy, Control Adapter RoHS-Compliant Figure 4-38. CDM-710G Modem-to-Switch Control & IF Connections – KT/12554

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–45 4.7.2 Modem-to-User Data Interface Kit and Connection Examples In addition to the basic switch‐to‐modem cabling shown in the previous section, a number of data interface configuration kits are available for use with the CDM‐710G. Figure 4-39. CDM-710G Block Diagram: User Æ Modem Æ Switch Æ Traffic Figure 4‐39 shows a block diagram typical for the kits shown in Sects. 4.7.2.1 and Sect. 4.7.2.2. Separate cabling kits are needed for these CDM‐710G data interfaces. For example, Sect. 4.7.2.1 identifies the interface kit used for the CDI‐10‐1 Single G.703 Data Interface. With the exception of the CDI‐70 Gigabit Ethernet Data Interface configuration shown in Sect. 4.7.2.3, where user‐provided Ethernet cables and Layer 2 Switch are used, one interface kit per 1:1 modem pair is required for each interface (see examples for specified quantities). The data interface combinations allowable in Interface Slots 1 and 2 of the CDM‐710G chassis are as follows: Allowable CDM-710G Combinations Interface Slot 1 Interface Slot 2 Single G.703 (CDI-10-1) None HSSI (CDI-60) None None GigE (CDI-70)

CRS-180 70/140 MHz IF 1:1 Redundancy Switch

Revision 8 Cables and Connections MN/CRS180.IOM 4–46 4.7.2.1 Single G.703 E3/T3/STS-1 75Ω Data Interface (CDI-10-1) Kit KT/12583 Figure  4‐40  shows  an  example  of  a  CDM‐710G  1:1  modem  configuration  with  the  CDI‐10‐1 Single G.703 Data Interface installed in Slot 1, and Slot 2 empty. The figure depicts installation of one KT/12583 Single G.703 Interface Kit. KT/12583 Single G.703 (CDI-10-1) 75Ω Interface Kit CEFD Part No. Qty Description CA/BNC75OHM 4 Cable – IF BNC, 75Ω, 1’ RF/SA32KC-IN/OUT 2 Combiner – 2-way w/Bracket, 0.25-300 MHz, 75Ω BNC Figure 4-40. CDM-710G Single G.703 E3/T3/STS-1 1:1 Example MODEM A MODEM B To User From User

Other Switch Manuals