Metrotech 880B Operation Manual
Read Online
Read the Metrotech 880B Operation Manual online using the built-in PDF viewer.
Key Pages of Document
Corporate Headquarters Metrotech Eastern U.S. Service Center Metrotech European Service Center 3251 Olcott Street 1824 Murfreesboro Road, Ste. 104 Seba KMT Santa Clara, CA 95054 Nashville, TN 37217 Dr. Herbert Iann St. 6 800-446-3392 800-624-6210 96148 Baunach, Germany 408-734-1400 Direct 615-366-7323 Direct +49 9544 680 408-734-1415 Fax 615-360-9855 Fax +49 9544 2273 Fax www.metrotech.com ...
Metrotech has received ISO 9001:2001 Quality Management System Certification. Metrotech adheres to the quality standard guidelines of ISO 9001:2001 and ensures quality in its design/development, production, installation, and servicing disciplines. © Metrotech Corporation 2008 Metrotech Corporation 3251 Olcott Street, Santa Clara, CA 95054 Tel: 1.800.446.3392; 1.408.734.1400 Fax: 1.408.734.1415 E-mail: [email protected] Internet ...
Page 1 Introduction…………………………………………………………… 5 2 Model 880 Equipment………………………………………………… 5 2.1 Standard Equipment……………………………………………. 5 2.2 Technical Specifications……………………………………….. 5 2.3 880B: Controls & Indicators…………………………………... 6 3 Checkout Procedure……………� ...
Figure Page 2-1 880B: Standard Equipment…………………………….… 5 2-2 880B: Controls and Indicators…………………………… 6 4-1 Typical Peak Reading……………………………………… 7 4-2 Vertical Orientation – Smooth Peak Response………….. 8 4-3 Horizontal Orientation – Sharp Pinpointing Null……….. 8 4-4 Two Readings of Target Depth……………………………. 9 4-5 D ...
only buried magnetic (iron and steel) objects, rejecting those objects that are not magnetic, i.e. aluminum cans, bottle caps, etc. The “fine tuned” sensitivity of the 880B makes it possible to locate magnetic objects at greater depths. The Metrotech Model 880B provides utility companies, contractors, engineers or surveyors with a v ...
gradient field intensity Weight: 1 lb. 10 oz. (3/4 kg) Dimensions: 43”L x 2 ½”W x 1 ½”T (109 x 6.9 x 3.8 cm) Temperature: Operating: 0º F to +122º F (-10º C to +50º C) Storage: -4º F to +158º F (-20º C to +70º C) Construction: High Impact UV Resistant Plastic Figure 2-2: 880B Controls and Indicators 2.3 880B: Controls and Indicators Figure 2-2 Designation ...
higher the tone, the closer the object. 3 CHECKOUT PROCEDURE 1) Hold the unit (in a vertical position) 6 – 12 inches above a 10p nail. Turn the ON/OFF/SENSITIVITY knob to “12 o’clock” position. The unit should display full meter deflection. 2) If neither the 880B meter nor speaker respond, replace the batteries. See Section 5.1 for battery replacement instructions. This ...
instrument will switch to the operating mode. 2) Turn the ON/OFF/SENSITIVITY knob so that the meter reads in the “SET” position. 3) Hold the instrument in front of you and sweep it from side to side, keeping the end of the instrument as close to the ground as possible. 4) When the 880B approaches a ferrous target, the audible tone will increase, corr ...
4.2 Typical Signatures and Operating Hints You can develop a good sense of target depth by taking two readings from a target – one with the instrument tip at the ground surface, and one with the end of the 880B four to twelve inches above the ground. The response to a shallow target diminishes more rapidly than that of a deeper target. See Figure 4-4. Once a target depth has been estimated, a rough idea of it ...
Figure 4-7: Narrow, Vertical Target, Not Strongly Magnetized Figure 4-8: Narrow, Vertical, Strongly Magnetized ...
Figure 4-10: Sloping, Narrow, Target Strongly Magnetized Figure 5-1: Replacing the 880B Receiver Batteries ...
dry, clean and free of grit. Store the 880B (in its carrying case) in a cool, dry place. Do not expose to excessive temperatures. 5.1 Battery Replacement The only maintenance requirement for Model 880B is to monitor the condition of the battery and replace the battery when necessary. To replace the battery follow the steps below: 1) Ha ...
change without notice. Metrotech Corporation makes no warranty of any kind with regard to the information contained in this manual, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Metrotech shall not be liable for errors contained herein, nor for incidental or consequential damages ...
Related Devices for Metrotech 880B:
Metrotech Corporate Headquarters 3251 Olcott Street Santa Clara, CA 95054 1 800 446 3392 Toll Free - Sales 1 800 638 7682 Toll Free - Service 1 408 734 1400 Dir Complete usage guide for the Metrotech MetroMark i5000 Series Measuring Instruments. This documentation details procedures for setup guidelines, cleaning instructions, connectivity setup, interface navigation.
810™ Line Tracer OPERATIONS MANUAL SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION Corporate Headquarters Metrotech Eastern U.S. Service Center Metrot Advanced user guide for the Metrotech 810 Line Tracer Measuring Instruments. The document details configuration and reset instructions, maintenance guidelines, system configuration.
9800XT™ SFL2 SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION Corporate Headquarters Metrotech Eastern U.S. Service Center Metrotech European Service C Practical user guide for the Metrotech 9800XT SFL2 Series Security Sensors. This manual describes setup, usage, and functional overview, calibration steps, technical overview, component replacement.
2 480B™ SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION Corporate Headquarters Metrotech Eastern U.S. Service Center Metrotech European Service Center Comprehensive user handbook for the Metrotech 480B Security Sensors. It describes step-by-step performance details, setup validation, device reset instructions, software installation.
810 DX™ Pipe and Cable Locator SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION Corporate Headquarters Metrotech Eastern U.S. Service Center Metrotech Usage and setup manual for the Metrotech 810 DX Measuring Instruments. This manual covers installation support, shutdown procedures, technical specifications, usage examples.
1 880B ™ SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION Corporate Headquarters Metrotech Eastern U.S. Service Center Metrotech European Service Cente Setup instructions for the Metrotech 880B Security Sensors. This guide presents setup instructions, system configuration, setup guidelines, technical assistance.
480B™SFL 2Dx SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION Corporate Headquarters Metrotech Eastern U.S. Service Center Metrotech European Service C Step-by-step guide for the Metrotech 480B SFL 2Dx Measuring Instruments. It explains maintenance and hardware setup, backup procedures, component overview.
Security Sensors: Frequently Requested PDF Instructions
Wireless detectors / Vezeték Nélküli Érzékelõk / Bezdrôtové snímaèe Intruder alarm system BK1, BK3, BK4, BT1 SECOLINK wireless detectors / SECOLINK Ve Setup and usage guide for the SECOLink BK1 Security System. It describes maintenance tasks and operating modes, warranty information, system checks.
Doc No. FM0458 issue F Page 1 169MHz Telecare Devices Flood Detector _________________________________________________________________________________________ Official installation manual for the LEGRAND Tynetec ZXT424 Security Sensors. The guide explains operation and service procedures, troubleshooting, diagnostic information.
1. INTRODUZIONE DT1000AM è un sensore a doppia tecnologia con funzione antiacceca- mento e lente antistrisciamento, gestito da microprocessore, la sezione infr Device technical manual for the Fracarro DT1000AM Security Sensors. The manual contains instructions for calibration steps, error codes, power management, service procedures.
___________________________________________ __MANUALE DI INSTALLAZIONE __ __TECHNICAL MANUAL__ _________MADE IN ITALY________ Rilevat Instruction reference guide for the ITALIANA SENSORI 8017-ISR013 Security Sensors. The document highlights operating procedures and repair references, connectivity setup, hardware instructions.