882D Belt Scale Integrator and 882IS/882IS Plus Indicators
Single Analog Output Option Card
The Single Analog Output Card (PN 164704) provides either a 0-10 VDC or 0-20 mA (4-20 mA) output, proportional to the
selected mode source (can also be controlled via the iRite user program).
See the 882D technical manual (PN 184260) or the 882IS I/O Module installation manual (PN 194139) for complete instruction
of the corresponding product on opening the enclosure and the necessary connection ports.
Manuals and additional resources are available from the Rice Lake Weighing Systems website at www.ricelake.com
Warranty information can be found on the website at www.ricelake.com/warranties
Always disconnect power before opening an enclosure. Option card is not hot swappable.
A grounding wrist strap must be worn to protect components from electrostatic discharge (ESD) when working
inside an enclosure.
Kit (PN 190528) Parts
Figure 1. Analog Output Option Card
The included parts kit contains items used for installation of the card. See the 882D technical manual or the 882IS I/O Module
installation manual for more information on shield grounding.
Part No.
Description
Qty
164704
Board Assembly, Single Com
1
190927
Parts Kit (*includes the parts listed below)
1
*15130
Washer, Lock NO 6 Type A (used for stud grounding)
1
*15631
Cable Tie, 3 inch Nylon (secures cable in panel mount installation)
4
*153878
Connector, 4 Pos Screw Terminal (interface connector)
1
*180826
Nut, M4 x 0.7 Hex (used for stud grounding)
1
*194487
Screw, SEMS Phillips M3 x 6 (secures card to controller assembly)
3
*53075
Clamp, Ground Cable Shield (used for stud grounding)
1
Table 1. Analog Output Option Card Kit Parts List
WARNING
CAUTION
PN 190908 Rev B
December 3, 2019
882D and 882IS Single Analog Output Option Card
2
Visit our website www.RiceLake.com
Installation Procedure
882D – the analog output option card works in option card slot 1 (J8 connector) and slot 2 (J9 connector) of the
882D CPU board (Rice Lake Weighing Systems also offers interface option cards that must be used in
slot 1, which would require the analog output option card to be used in slot 2 if used simultaneously)
882IS – the analog output option card works in the option card slot (J8 connector) of the 882IS I/O Module board
(I/O Module board only has one option card slot)
1.
Disconnect power to the unit.
2.
Remove the backplate from the 882D enclosure or the 882IS I/O Module.
3.
Connect option card to J8 or J9 connector on the 882D CPU board or to J8 connector on the 882IS I/O Module board.
4.
Secure the option card board with the three provided M3 screws from the option kit.
5.
Route the cable and make the connection to the option card.
Figure 2. Analog Output Option Card
For the 882D, the option card slot selected for the installation of the analog output card determines the analog output
number available: Slot 1 = Output 1; Slot 2 = Output 3
6.
Ensure no excess cable is left inside the enclosure and use the provided cable ties to secure loose cables inside the
enclosure as needed.
7.
Ground the shield cable using the grounding stud on the enclosure with the included cable clamp.
8.
Tighten the cord grip and cord grip nut.
9.
Reinstall the backplate to the 882D enclosure or the 882IS I/O Module.
10. Reconnect power to the unit.
The analog output must be calibrated after the indicator has been configured and calibrated.
The 882D and 882IS automatically recognizes all installed option cards when the unit is powered on.
No hardware-specific configuration is required to identify the newly-installed card to the system.
Connector
Pin
Channel 1
J1
1
I+
2
I-
3
V+
4
V-
Table 2. Pin Assignments
Note
J3
J6
J4
LED8
LED1
LED2
LED3
J1
1
2
3
4
Pins:
V-
V+
I-
I+
CHANNEL 1
Note
Note
882D and 882IS Single Analog Output Option Card
© Rice Lake Weighing Systems ● All Rights Reserved
3
LED Status Indicators
Figure 3. Analog Output Option Card LEDs
Specifications
LED
Status
1
LED Card Status
2
Green – LED Channel 1 is good
3
Red – LED Channel 1 is faulty
Table 3. LED Status Light Descriptions
J3
J6
J4
J1
V-
V+
I-
I+
LED8
LED1
LED2
LED3
Resolution
16-bit, monotonicity over
temperature
Linearity
±0.03% of full scale input
Current Output
0–20 mA or 4–20 mA (20% offset)
Maximum Load
840
Resistance
Power Consumption
Voltage Output
Minimum Load
3.9 W (max. load @ 20 mA)
0–10 VDC
1.1 K
Resistance
Power Consumption
3.9 W (max. load @ 10 VDC)
Input Protection
Short circuit protection, 300 W
transient voltage suppression
Protection for ESD, EFT
(electrical fast transients), tertiary
lightning, and system-generated
transients per IEC 60001-4-2,
60001-4-4, and 60001-4-5;
European Standards EN50082
and EN61000-4
230 W. Coleman St. • Rice Lake, WI 54868 • USA
U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319
Rice Lake Weighing Systems is an ISO 9001 registered company.
© Rice Lake Weighing Systems Specifications subject to change without notice.
www.ricelake.com
PN 190908 Rev B
December 3, 2019