RF SOLUTIONS EZTEXT Manual
| Brand: | RF SOLUTIONS |
| Category: | Remote Control |
| Model: | EZTEXT (Manual ) |
| File Type: | |
| File Size: | — |
| Pages: | 14 |
Text of RF SOLUTIONS EZTEXT Manual
RF SOLUTIONS EZTEXT 2013 REG No 277 4001, ENGLAND.
Page 1 of 14
EZTEXT - GSM REMOTE CONTROL
• Two Way Remote Control From a Cell phone
• Easy to Install and Configure using SMS commands
(No PC required).
• 2 Digital Inputs (Volt Free)
• 2 x Relay Outputs rated 240Vac 5A
• Optional external Temperature / Humidity Measurement
• User Can set inputs and outputs Names
• Outputs controlled by SMS text message
• Automatically Sends SMS message when inp
2013 REG No 277 4001, ENGLAND. Page 2 of 14
EZTEXT - GSM REMOTE CONTROL
1. Insert Simcard
Please note:
•
Insert SIM Card before applying power (standard 3 Volt SIM only).
•
The message memory of the SIM card should be clear before it is fitted.
•
Ensure that the SIM card has not been PIN Code Protected!
•
Beware of Pay-as-you-go SIM which require regular top-up to remain active.
•
It is recommended to bar Incoming voice calls to th
2013 REG No 277 4001, ENGLAND. Page 3 of 14
EZTEXT - GSM REMOTE CONTROL
3. LED Indication at Startup
4. LED Indication After Startup (Normal Operation)
Good
OK
Poor
Signal Strength
Activity LED’s
Receiving an SMS
RX
TX
GSM
Transmitting an SMS
Intermittent Flash GSM Healthy
Loging onto Network
(traffic light sequence)
30
20
10
Error!
(All Flash ON / OFF together)
Error - No GSM Service
1. Check SimCard
2. Check Antenna Connection
30
20
10
R
2013 REG No 277 4001, ENGLAND. Page 4 of 14
EZTEXT - GSM REMOTE CONTROL
5. Optional Battery Backup (880mAH Lithium rechargeable)
The battery provides an automatic backup supply to continue normal operation when power fails. EZTEXT
can also send an SMS when power is switched to battery and when main power is restored.
The battery is recharged and maintained when power is present
In the event of a complete power loss, EZTEXT will retain user c
2013 REG No 277 4001, ENGLAND. Page 5 of 14
EZTEXT - GSM REMOTE CONTROL
7. Optional Temperature / Humidity Measurement
Using the Cable adaptor CBA-EZTEMP provides a 1metre plug in cable with temperature probe.
This enables the EZTEXT temperature monitor and control functions
Connect Cable
CBA-EZTEMP
Here
2012 REG No 277 4001, ENGLAND.
Page 6 of 14
EZTEXT - GSM REMOTE CONTROL
8. User Set-Up Commands
Title
Command
Description
Example
Password
UPW
UPW#UNITPW
User must send UPW command within 5 mins after power applied. Setting the UPW
is carried out by sending this text message to the unit.
The User Password (4 – 8 Characters) is case sensitive and can consist of any
letters or numbers.
If for any reason the unit password is lost, remove all
2012 REG No 277 4001, ENGLAND. Page 7 of 14
EZTEXT - GSM REMOTE CONTROL
9. INPUT Commands.
Title
Command
Description
Example
Set an Input
Name
IPNAME
IPNAME?
When the input changes this is the name that the EZTEXT will transmit in its
text message
UNITPW#IPNAMEn#
This designates a to an EZTEXT input (max15 characters)
n=1 - 4 for inputs1 to 4
UNITPW#IPNAME?
Requests the name given to all inputs
1234#IPNAME1,Gate
Sets input 1 to
2012 REG No 277 4001, ENGLAND. Page 8 of 14
EZTEXT - GSM REMOTE CONTROL
INPUT Commands cont….
Title
Command
Description
Example
Set No of
Input
Acitvations
before SMS
Sent
IPCNT
IPCNTVAL?
Sets the number of times an input must be activated befre an sms is sent
2012 REG No 277 4001, ENGLAND. Page 9 of 14
EZTEXT - GSM REMOTE CONTROL
10. Output Commands
Title
Command
Description
Example
Activate an
Output
OUT
Turns an Output ON or OFF
UNITPW#OUTn,x
n=Relay number = 1 to 4
x=Relay Status = ON, OFF
1234#OUT1,ON
Turns Output1 ON
Set an output
name
OPNAME
OPNAME?
This designates a name to an EZTEXT output
UNITPW#OPNAMEn,name
n=Output no
name= name can be upto 15 characters.
UNITPW#OPNAME?
Requests the na
2012 REG No 277 4001, ENGLAND. Page 10 of 14
EZTEXT - GSM REMOTE CONTROL
11. Power Fail Commands
Title
Command
Description
Example
Number to text
on Power
Failure
PFNUM
PFNUM?
PFNUMDEL
This command sets a number to text (max 5 nos) when Power Failed (only if
optional battery fitted)
UNITPW#PFNUM#
Sets the number to text on power fail
UNITPW#PFNUM?
Requests the current numbers that are stored
UNITPW#PFNUMDEL
PFNUMDEL Deletes all
RF SOLUTIONS Remote Control Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
ELITE |
User Manual: RF SOLUTIONS ELITE (GXHPX2, Upd.27-06-2026) |
2 | 454 | 87 | 27-06-2026 | |
TAURUSDIN |
TAURUSDIN (Remote Control ePDF Guide, #7I7TS7) |
2 | 1089 | 251 | 06-09-2026 | |
TRAP |
#6239F7: TRAP Remote Control Quick start manual |
2 | 259 | 39 | 20-08-2026 | |
PRO Series |
User Guide: RF SOLUTIONS PRO Series (17I279, Upd.16-07-2026) |
6 | 1473 | 266 | 16-07-2026 | |
HORNETPRO Series |
User Manual: RF SOLUTIONS HORNETPRO Series (HA417L, Upd.25-09-2026) |
7 | 1371 | 288 | 25-09-2026 | |
ELITE-KIT |
RF SOLUTIONS ELITE-KIT User Guide (Manual ), @H14B85 |
10 | 1122 | 247 | 18-09-2026 | |
RIoT-Minihub |
Remote Control #8ZD36Z |
8 | 1455 | 335 | 06-06-2026 | |
QS-TRAP-SHUFFLE-R1 |
QS-TRAP-SHUFFLE-R1 (Remote Control ePDF User Guide, #164I1M) |
8 | 962 | 212 | 31-08-2026 |