Regent Lighting Solutions Longo Installation Instructions

Text of the manual

ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN

ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN 1 PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION. PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION. Regent Lighting reserves the right to change specifications modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. WARNING: TO AVOID FIRE, SHOCK OR DEATH TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING ALL LUMINAIRES SUPPLIED AND TO BE INSTALLED ABOVE AND BELOW 5 METERS ARE IN COMPLIANCE WITH SANS 60598 SECTION 3.5.6 ACCORDING TO THE MANUFACTURER GUARANTEE AND WARRANTY Electrical products can cause death, injury, or damage to property. Installation of this product must be carried out by a qualified electrician, in compliance with SANS 10142 or corresponding regulations of the country of installation. On completion of installation, the Certificate of Compliance must be updated. WARNING Electronic Control Device Electronic Control Device WARNING 3 - 13 MAIN REEF SERVICE ROAD, CORNER SPRINGBOK AND MAIN REEF ROAD, INDUSTRIA, JOHANNESBURG. SOUTH AFRICA. TEL : +27 11 474 0171 www.regentlight.co.za REGENT LIGHTING A DIVISION OF WAHL INDUSTRIES. Save These Instructions for Future Reference ELECTRIC SHOCK HAZARD This equipment is to be serviced by trained personnel only. ELECTRIC SHOCK HAZARD This equipment is to be serviced by trained personnel only. Longo DO NOT CONNECT THE FITTING LIVE March 2018 For non replacable lightsources: The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced 92MM Product installed finished with conduit drainage FFL / Tiled Surface Grout Concrete Drain Product installed finished with gravel drainage Requirements:  Be sure the electricity to the system you are working on is isolated.  If the main supply power (live) is on, it will cause damage to the luminaire. 1. Select required position. Create a cavity with drainage for fitting in the ground/paving at the required position. The total height of the product is 92mm and SHOULD be level with the FINISHED floor level - FFL (the tiled surface). *NB: GRAVEL FOR DRAINAGE - Lay at least 150mm of gravel beneath the well of the cavity and check drainage efficiency. Ensure there is a drain under the gravel when installing the fitting into paving or cement. 92MM FFL / Tiled Surface Grout Concrete Gravel DO NOT PLUG (CONNECT) WHEN LIVE AS IT WILL CAUSE DAMAGE TO THE LUMINAIRE. 9 9. Place the fitting into the aluminium extrusion. Connect to main supply using the electrical tail supplied from the fitting. Ensure the fitting is secure in the aluminium extrusion. Fitting Electrical tail Mains to Luminaire Earth Loop Green/Yellow Switch Live Red Neutral loop Black or Blue (L) Brown (E) Green/Yellow (N) Blue DO NOT PLUG (CONNECT) WHEN LIVE AS IT WILL CAUSE DAMAGE TO THE LUMINAIRE.

This product should be installed by a competent person i.e. Qualified electrician.

This product requires a constant stable electrical supply 220V - 240V VAC 50Hz - alternating current. The product must be regularly maintained, including the replacement of lamps/LED timeously. This product could be HAZARDOUS if not used correctly, it could cause electric shock, serious bodily harm or death. This product is not a toy, please keep away from children. This product may contain small parts that can be swallowed. Use only the correct light bulbs/LED as stipulated on the carton for the product. Any modifications of this product after supply will result in the guarantee being void. Spare parts may become unavailable over time.Items can vary slightly from the picture on the carton Coastal humidity can affect the longevity of the light fitting over time. Be sure to follow the steps in the order given. Read instructions carefully. Important Safety Instructions 2 3 Drain Conduit Drain Conduit locator Casting polystyrene plug Protrude the drain conduit through the polystyrene 3. Place the casting polystyrene plug with the drain conduit in position on the slab before casting the concrete. Ensure the polystyrene plug is at the correct level on the positioning wedges. Cast the concrete / surface bed. 2. Place the Drain conduit locator under the casting polystyrene plug before placing it in the cavity. Protrude the drain conduit through the polystyrene. 2 3 92MM Casting polystyrene plug F.F.L SLAB Surface bed/ concrete Positioning wedge Drain conduit STEP 2 2 5 Polystyrene Casting plug Surface bed Conduit for wiring to main supply 4. Ensure there is a conduit in the cavity to the main supply. All fittings are supplied with an electrical tail. 4 5. A. Once the concrete has set, remove the polystyrene casting plug from the cavity, indicated in A & B. Surface bed without polystyrene casting plug Drainage B Casting polystyrene plug Concrete surface bed A Endcap Fisher plate for continuous lengths 26 7 6. Prepare the aluminium extrusion by fastening the end caps and/or fischer plate (for continuous lengths) to the extrusion. Ensure the extrusion has drainage holes. Ensure the end caps and fisher plates are securely fastened. Aluminium extrusion FFL TRIM CONDUIT TRIM CONDUIT 7. Align and place the assembled aluminium extrusion into the cast cavity over the drainage conduit, ensure the extrusion protrudes from the surface bed to the FFL. Ensure the Aluminium extrusion is securely placed in the cavity. Trim the protruding conduit to the base of the extrusion. 28 Tiling plug A Tiling finished floor Grout Tiling plug B Tiling plug C A: Insert tiling polystyrene plug into the extrusion before grouting and tiling up to the finished floor level. B: Grout around the extrusion and tile up to the aluminium extrusion edge or FFL. Ensure that no grouting gets trapped into the aluminium extrusion. C: Remove the tiling polystyrene plug from the aluminium extrusion. Ensure there is no grout in the extrusion. STEP 9 continued on the next page...

Other Lighting Equipment Manuals