Q-Optics Radiant Instructions & Care

Specifications

Brand: Q-Optics
Category: Lighting Equipment
Model: Radiant (Instructions & Care)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Q-Optics Radiant Instructions & Care online using the built-in PDF viewer.

Text of the manual

P.O. Box 382120

Duncanville, Texas 75138-2120 USA Phone: (972) 298-2669 • Fax: (972) 298-6592 1-800-858-2121 email: [email protected] www.q-optics.com CLEANING & CARE INSTRUMENT ATTACHMENT & BATTERY PACK DISINFECTION The instrument attachment and battery pack can be cleaned using Q-Optics optical cleaner or moistened cloth. To remove debris on instrument attachment or battery pack, spray the Q-Optics Cleaner directly onto the surface. Using a microfi ber cloth or clean cloth, thoroughly wipe down the instrument attachment (including the cable) and battery pack. DO NOT spray the cleaner directly into any electrical openings. Doing so could cause damage to the unit and void product warranty. The instrument attachment and battery pack should only be disinfected using the Q-Optics Dis-Foam™. Any other form of disinfectant could cause damage to unit. To disinfect, simply spray the Q-Optics Dis-Foam™ directly onto the surface to be disinfected. Using a microfi ber cloth or clean dry cloth, thoroughly wipe units dry. DO NOT spray the foam directly into any electrical openings. Doing so could cause damage to the unit and void product warranty. UI-317-10010-01 ECN # 729

INSERT OR REMOVE

INSTRUMENT OPERATION CLEANING & CARE INSTRUMENTS STEP 3: Insert or remove the instrument as needed. STEP 4: Release the collar and it will snap back into position. STEP 1: Grasp ACMI Quick Disconnect Collar between Thumb and fore fi nger as shown. STEP 2: Pull collar back toward the black handle of the instrument adapter. It will only move about 3 mm. PULL BACK The fi ber optic light transmitting surfaces on both ends of the fi ber optic clip or wand should be wiped clean with isopropyl alcohol before autoclaving or chemiclaving. In the event that a fi ber optic clip becomes loose, gentle pressure can be applied with pliers to tighten clips. STERILIZATION Your fi ber optic instrument may be autoclaved or chemiclaved. Do not exceed 275°F (135 C). Please note that exposure to heat will reduce the life of your fi ber optic instrument. The average life expectancy of fi ber optics is 18 to 24 months with autoclaving or chemiclaving. This time could be longer or shorter depending on frequency and temperature of autoclave or chemiclave. DO NOT attempt to sterilize the Instrument Cable or Battery Pack. See reverse side for cleaning and care of instrument cable and battery pack. On/Off button: Turn on & off, Comes on at last used intensity setting Increase intensity button: 10 positions, beeps when pressed, long beep at maximum intensity Decrease intensity button: 10 positions, beeps when pressed, long beep at minimum intensity Low Battery Warning: 5 short beeps, every 60 seconds, starts with about 7 minutes life remaining Use circular motion Connect instrument adapter cable to battery pack and enjoy your Q-Optics Radiant™ Light System.

Other Lighting Equipment Manuals