Rane VR2 Data Sheet / Manual

Specifications

Brand: Rane
Category: Remote Control
Model: VR2 (Data Sheet / Manual)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Rane VR2 Data Sheet / Manual online using the built-in PDF viewer.

Text of the manual

DATA SHEET / MANUAL

VR2 VOLUME REMOTE Description The VR2 mounts in a standard US electrical box and can be covered with a Decora plate. It contains a linear taper potentiom- eter with a single Euroblock screw terminal for each of the pot’s three conductors, the Vr terminal, the Vc wiper terminal, and the ground terminal. Connection Turn the power to the unit off until all connections are made. Con- nect the VR2's control voltage Vc (wiper) connection(s) first. Then connect the voltage reference - “Vr” on the VR2 (“REF” terminal on a RPM unit). Connect the GND (ground) terminal last. Double and triple check your wiring before applying power to the MA 4 or RPM since improper wiring can and will cause permanent, irreparable damage to the VR2, requiring replace- ment of the remote. Such damage is not covered by Rane's war- ranty; checking the wiring is easier than a second trip to the job site with another remote. Euroblocks Be sure to note the wire color of each input in order to facilitate correct wiring to the controlled unit. If the ground or shield wire is left shorter, it acts as a strain relief for the other wires. Con- nect each wire to the 3-pin connector by fully inserting it in the correct socket and tightening the screw. Make sure wires are free of nicks and that the cable jacket is stripped back sufficiently to allow it to lie in the electrical box with the remote assembly inserted. Voltages Turn the power to the unit off until all connections are made. It is important to ensure that the Remote Ports are not subjected to sustained voltages outside the range of 0 to 5 volts DC or high levels of static. Inputs are protected, however, caution is the better part of... you know. It is a good idea to install the wiring, connect it to the Remote and then make the final connections at the Remote Port. Do not short the Vref pin to ground. This pin is current limited, however, excess heat is generated in the 5 volt supply if a short occurs. Never subject the Vr pin to voltages above 5 volts. Remote Mounting The VR2 remote assembly mounts in a standard U.S. electrical box with a minimum depth of 2.25" (5.5 cm). Use the flat head #6 screws supplied with the kit to mount the remote assembly and silk-screened front panel to the electrical box. Install the knob so that the line on the knob is properly aligned with the silk-screening on the front panel of the remote. Install any Decora plate of your choice. For a secured installa- tion, you may wish to leave the knobs off and use a blank Decora plate to cover the remote after adjustment. Vc GND Vr 4 0 2 6 8 10 LEVEL Decora plate cover, not supplied.

VERSATILE INPUT PORT

All features & specifications subject to change without notice. PN 12907 ©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5000 TEL 425-355-6000 FAX 425-347-7757 WEB rane.com Wire Types Variations in wire type do not greatly affect the performance of the remote controls. However, a minimum gauge of 22 strand- ed wire with a flexible jacket is recommended. You may use 3-conductor unshielded remote control signal cable for shorter runs (less than 200 ft.) or 2-conductor (1 pair) shielded remote control signal cable (use the shield as the GND return) for longer runs (200 to 1000 ft.). The type of wire required is influenced by your installation and local electrical codes. Rane Corporation does not provide or source cable. Please contact your local retail or wholesale outlet, not the factory. The following is a short list of suitable cable types: CONSOLIDATED ELECTRONIC WIRE AND CABLE Plenum cable: Unshielded remote control signal cable CAT. # 9896 Shielded remote control signal cable CAT. #9877, CAT. #9852 WEICO WIRE & CABLE INC. Communication and control cable: Multiconductor, unshielded CAT. #7606 ALPHA Communication and control cable: Multiconductor, unshielded CAT. #1175C BELDEN Unshielded remote control signal cable CAT. # 88741 Shielded remote control signal cable CAT. # 88723 VR2 All-in-One Block Diagram and Schematic Wiring shown for VR2 to control VIP pin 1 on RPM series units. Versatile Input Port Silkscreen text on VR2 REF Vr GND GND VIP pin 1....8 Vc 20 kΩ, linear taper GND Vc CW Vr WARNING: This product may contain chemicals known to the State of California to cause cancer, or birth defects or other reproductive harm.

Other Remote Control Manuals