Digisol DG-GS1528HP/C Web Management User Manual
Read Online
Read the Digisol DG-GS1528HP/C Web Management User Manual online using the built-in PDF viewer.
Text of the manual
24 PORT GIGABIT WEB MANAGED POE+ SWITCH
WITH 2 GIGA COMBO + 2 GIGABIT SFP PORTS
Web Management User Guide
V1.0
2019-11-25
As our products undergo development the specifications are subject to change without prior notice
DG-GS1528HP/C User Manual
COPYRIGHT
Copyright 2019 by Digisol Systems Ltd. All rights reserved.
Company has an ongoing policy of upgrading its products and it may be possible that information
in this document is not up-to-date.
Please check with your local distributors for latest information. No part of this document can be
copied or reproduced in any form without written consent from the company.
Trademark
DIGISOL TM is a trademark of Digisol Systems Ltd. All other trademarks are the property of the
respective manufacturers.
DG-GS1528HP/C User Manual
INDEX
About guide..................................................................................................................................................... 1
Terminology / Usage ...................................................................................................................................... 1
1 Product Introduction .................................................................................................................................... 2
Front panel .................................................................................................................................................. 2
Rear panel .................................................................................................................................................. 2
2 Hardware installation .................................................................................................................................. 3
First step: open a seal .................................................................................................................................... 3
Second step: switch installation...................................................................................................................... 3
Desktop or Shelf Installation ....................................................................................................................... 3
Rack Installation .......................................................................................................................................... 3
Third step: Plugging in the AC Power Cord .................................................................................................... 4
Power failure ............................................................................................................................................... 4
3 Getting Started ............................................................................................................................................. 5
Management Option ....................................................................................................................................... 5
Using Web-based Management ..................................................................................................................... 5
Supported Web Browsers ........................................................................................................................... 5
Connecting to the Switch ............................................................................................................................ 5
Login Web-based Management .................................................................................................................. 6
1.
WEB page elements ................................................................................................................................ 7
2.
The structure of Navigation tree .............................................................................................................. 8
3.Page button Introduction ............................................................................................................................. 8
4.Error messages ........................................................................................................................................... 9
5.
Entry Field ............................................................................................................................................... 9
6.
Status Field ........................................................................................................................................... 10
1.
Main Page .......................................................................................................................................... 12
2.
System Configuration: ....................................................................................................................... 12
3.
Port Configuration .............................................................................................................................. 18
4.
MAC binding ...................................................................................................................................... 24
5.
MAC filtering ...................................................................................................................................... 25
6.
VLAN Configuration ........................................................................................................................... 27
7.
SNMP Configuration .......................................................................................................................... 29
8.
ACL Configuration ............................................................................................................................. 31
9.
QoS Configuration ............................................................................................................................. 35
10.
IP Basic Configuration ................................................................................................................... 36
11.
Certification. Authorization. Accounting (AAA) configuration ......................................................... 39
12.
Spanning Tree Protocol configuration............................................................................................ 42
13.
IGMP SNOOPING configuration .................................................................................................... 44
14.
GMRP configuration ....................................................................................................................... 46
15.
EAPS configuration ........................................................................................................................ 47
17、RMON configuration .......................................................................................................................... 49
18、Cluster configuration ......................................................................................................................... 52
19 Log management ................................................................................................................................. 54
20、PoE port configuration ....................................................................................................................... 55
DG-GS1528HP/C User Manual
1
About guide
This guide provides instructions to install the Switch.
Note: The model you have purchased may appear
slightly different from the illustrations shown in the
document. Refer to the Product Instruction and Technical
Specification sections for detailed information about your
switch, its components, network connections, and
technical specifications.
Terminology / Usage
In this guide, the term "Switch" (first letter capitalized) refers to the Smart Switch, and "switch" (first letter lower case)
refers to other Ethernet switches. Some technologies refer to terms "switch", "bridge" and "switching hubs"
interchangeably, and both are commonly accepted for Ethernet switches.
Note: indicates important information that helps a better
use of the device.
Warning: indicates potential property damage or
personal injury.
DG-GS1528HP/C User Manual
2
1 Product Introduction
Thanks for purchasing the Web Managed PoE Switch products.
The DG-GS1528HP/C is a Web Managed POE Switch, It provides 24 10/100/1000Mbps Auto-Negotiation RJ45 POE
ports and 2 Combo (RJ45+SFP) +2 Gigabit SFP Ports . It supports the port's full line speed forwarding to ensure the
stable transmission of data. This switch can be used as a small local core network or a mall and medium-sized LAN
and can also be used as an access switch for large LAN.
This product is a Gigabit network management type PoE Switch which can satisfy the full speed of forwarding ports.
The machine uses 19 "1U and so can be used on the desktop or on the rack. Excellent performance can help you
widely use in wireless, monitoring and other fields.
24 Port 10/100/1000Base-TX with 2 Combo (RJ45+SFP)+2 Gigabit SFP and 24 PoE+ L2 Web Managed Switch
Front panel
PWR LED:The Power LED lights up when the Switch is connected to a power source.
Link/Act LED: The Link/Act LED flashes which indicates a network link through the corresponding port. Blinking
indicates that the Switch is either sending or receiving data to the port.
Speed LED (GE only): The Port Speed LED lights up with solid green indicate the corresponding port is running on
1000M.
PoE LED: Blinking indicates that port is running on 100M. Light off indicated that port is running on 10M.
Green: Indicates the PoE powered device (PD) is connected and the port supplies power successfully.
Light off: Indicates no powered device (PD) connected.
Note: The SFP ports are shared with gigabit RJ45
ports. When SFP port is used, the RJ45 port cannot
be used.
Warning: The SFP ports should use UL listed Optical
Transceiver product, Rated Laser Class I. 3.3Vdc.
Rear panel
Power: The power port is where to connect the AC power cord.
Switch: Used to connect the power supply.
Fuse: Prevent affect of power grid from equipment short circuit. ( containing a spare fuse)
DG-GS1528HP/C User Manual
3
2 Hardware installation
This chapter provides unpacking and installation information for the Web Managed PoE switch.
First step: open a seal
Open the shipping carton and carefully unpack its contents. Please consult the packing list located in the User Manual
to make sure all items are present and not damaged.
Switch 1pcs
AC power cord 1pcs
Rubber feet 4pcs
Screws 6pcs
Mounting brackets 2pcs
User manual/CD 1pcs
If any item is found missing or damaged, please contact the local reseller for replacement.
Second step: switch installation
For safe switch installation and operation, it is recommended that you:
Visually inspect the power cord to see that it is secured fully to the AC power connector.
Make sure that there is proper heat dissipation and adequate ventilation around the switch.
Do not place heavy objects on the switch.
Desktop or Shelf Installation
When installing the switch on a desktop or shelf, the rubber feet included with the device must be attached on the
bottom at each corner of the device's base. Allow enough ventilation space between the device and the objects
around it.
Rack Installation
The switch can be mounted in an EIA standard size 19-inch rack, which can be placed in a wiring closet with other
equipment. To install, attach the mounting brackets to the switch's side panels (one on each side) and secure them
with the screws provided (please note that these brackets are not designed for palm size switches).
Then, use the screws provided with the equipment rack to mount the switch in the rack.
DG-GS1528HP/C User Manual
4
Please be aware of following safety Instructions when installing:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature
of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the
equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for
safe operation of the equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the
effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should
be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips)."
Third step: Plugging in the AC Power Cord
You can connect AC power supply cord to switch back and the other side connect the power outlet. (power outlet
might as well grounding and support over voltage protection)
Warning: Do not turn on the power switch before
power cables are connected. Power surge may
cause damage to the Switch.
Warning: The installation instructions clearly state that
the ITE is to be connected only to PoE networks
without routing to the outside plant.
Power failure
As a precaution, the switch should be unplugged in case of power failure. When power is resumed, plug the switch
back in.
DG-GS1528HP/C User Manual
5
3 Getting Started
This chapter introduces the management interface of Web Managed PoE switch.
Management Option
The Web Managed PoE switch can be managed through any port on the device by using the Web-based
management.
Each switch must be assigned its own IP address, which is used for communication with Web-Based Management or
a SNMP network manager. The PC should have an IP address in the same range as the switch.
Please refer to the following installation instructions for the Web-based Management.
Using Web-based Management
After a successful physical installation, you can configure the Switch, monitor the network status, and display statistics
using a web browser.
Supported Web Browsers
The embedded Web-based Management currently supports the following web browsers:
Internet Explorer 6 or higher version
Netscape 8 or higher version
Mozilla
Firefox 1.5/2.0 or higher version
Connecting to the Switch
You will need the following equipment to begin the web configuration of your device:
1.
A PC with a RJ-45 Ethernet connection
2.
A standard Ethernet cable
Connect the Ethernet cable to any of the ports on the front panel of the switch and to the Ethernet port on the PC.
Connected Ethernet cable
DG-GS1528HP/C User Manual
6
Login Web-based Management
In order to login and configure the switch via an Ethernet connection, the PC must have an IP address in the same
subnet as the switch. For example, if the switch has an IP address of 192.168.0.1, the PC should have an IP address
of 192.168.0.x (where x is a number between 2~ 254), and a subnet mask of 255.255.255.0. Open the web browser
and enter 192.168.0.1 (the factory-default IP address) in the address bar. Then press .
Open the web browser and enter 192.168.0.1 (the factory-default IP address) in the address bar. Then press .
Enter the IP address in the web browser
NOTE: The switch's factory default IP address is
192.168.0.1 with a subnet mask of
255.255.255.0
To log in to the switch, the IP address of your PC should be set in the same subnet as that of the switch. The IP
address is 192.168.0.x (”x” is any number from 2 to 254). Subnet Mask is 255.255.255.0.
When the following logon dialog box appears, enter the password then click OK. By default, the username is admin
and the password is admin.
DG-GS1528HP/C User Manual
7
Logon Dialog Box
1.
WEB page elements
Shown in Figure 2, WEB page is mainly composed of three parts: title page, navigation tree page and main page
Figure 2
Title page is Used to display the logo
Main page is used to display the user from the navigation tree, select the page
DG-GS1528HP/C User Manual
8
2.
The structure of Navigation tree
Figure 3 shows the navigation tree organizational structure.
Navigation tree is located in the lower left of each page, using the tree display nodes of the WEB page, users can
easily find the page you want to manage the WEB. According to a different web page functionality can be divided
into different groups, each including one or more pages. Most of the navigation tree in the name of the
corresponding web page top of page title abbreviation.
Figure 3
3.Page button Introduction
On the pages, here are Some commonly used button, the role of these buttons are generally the same, Form 2
on the role of these buttons are described:
Form 2:
button
effect
Refresh
Update all fields on the page
Apply
numerical value will be updated into the memory. Because the
error-checking should be implemented by the Web Server,
before the user selects the button will be no error checking.
Delete
Delete the current record
Help
Open help pages, view the individual pages of the
configuration instructions
DG-GS1528HP/C User Manual
9
4.Error messages
If the switch WEB server error occurred while processing user requests, it will display a dialog box in the
corresponding error message. For example, Figure 4 shows an error message dialog box.
Figure 4
5. Entry Field
Some pages of the most left column in the table has an entry field, as shown in Figure 5, through the field can
access different rows in the table. When you choose a line for the filed, which lines the corresponding information
is displayed in the first line, then only the line can be edited, the line also known as the activities line. A time when
it was first loaded, it shows the filed new, activity line is empty.
If want to add a new line should select new from the drop-down menu of entry field, , enter the new line’s
information, and then press apply button.
If you want to edit the line already exists, it is necessary to select the appropriate line number of the drop-down
menu, according to need to edit the line, and then press the apply button, you will see a corresponding change in
the table displayed.
If you want to delete a row, select the line number accordingly from entry field’s drop-down menu, then press the
delete key, this line will disappear from the table.
Figure 5
DG-GS1528HP/C User Manual
10
6. Status Field
Some pages of the most right column in the table there is a state field, as shown in Figure 6, the field displays
the line status. Since all row state changes are processed in-house, so the status field is read-only. Once the line
information of the entry filed into force, the line will automatically become the active state the status active.
Figure 6 the web page of status field
DG-GS1528HP/C User Manual
11
WEB page introduction
Switch WEB pages organized into groups, each including one or more of the WEB pages. The following are
introduced one by one on each page.
Login dialog Box
Figure 7 WEB browsing session of the login page
Figure 7 shows the login dialog box, the logon dialog box will be displayed while the user login the web page at
the first time. When The user filled out the correct username and password, then click the Enter button can log on to
the switch Web server. Passwords are case-sensitive, the anonymous user password can be maximum set up to 16
characters, while the multi-user name and password can be set up to 11 characters. Switch default user name is the
anonymous user name admin, default password for the anonymous user's password, The default username is admin
and password is admin.
DG-GS1528HP/C User Manual
12
1.
Main Page
Figure 8 shows the WEB main page of switch. This page will be displayed after the user logs in web pages
Figure 8 Switch main page
2.
System Configuration:
(1)Basic information page
Figure 9 is the basic information of configuration page, users can configure the basic information for the switch.
System Description display the description of the relevant parameters of system.
System descriptor ID display system in the network identity management.
The system version number is displayed the current software version number of switches.
The number of switches interface displays the current number of interfaces in the switch.
The system start-up time display switches from start to the present time.
The system name as the switch’s system name in the network, the user can modify the system name.
The systematic location as the switch’s physical location showing at the network, the user can modify the system
locations.
system Contact show the contacts person and details of the current node, the user can modify the system contact.
DG-GS1528HP/C User Manual
13
Figure9 Basic information Page
(2)Serial port information page
Figure 10 is a serial port configuration page, the page displays serial baud rate and other related information.
When the host through the serial port terminals (such as Windows, HyperTerminal) to the management of switches,
serial console on the COM port configuration must be consistent with this page information.
Figure 10 Serial port information page
DG-GS1528HP/C User Manual
14
(3)User management page
Figure 11 is a user management page, the user can modify this switch anonymous user (admin) password,
Telnet and the Web without opening a multi-user, they all use the same anonymous user's password. Passwords are
case-sensitive and can be up to 16 characters. If you want to change your password, the user need to enter the new
password twice, once the user clicks the application button, the new password is activated, then if the switch is not
enabled multi-user, will display the login dialog box (as shown in Figure 7), require the user to re - login the web page,
with a new anonymous user password.
Figure 11 user’s management page
(4)Security Management Page
Figure 12 is Security management configuration page, through the page's configuration, , the administrator can
control network management services TELNET, WEB and SNMP, you can open (enable) or off (disable) these
services, these services can be mounted up with standards IP ACL group ,and the implementation of the source IP
address control, control access to the host of these services
When the Switch default , TELNET, WEB and SNMP services are open and no ACL filtering, that is, all hosts
have access to the switch of these three services. If the administrator for safety, do not want to provide one or several
services, which can shut down one or several services. If the administrator only hope that the specified host could
access one or several services, can do the ACL filtering for one or several services. As a service to do ACL filtering,
you need to open the service, and to select an IP standard ACL group (1-99), the primary factor it’s the ACL group
must be present.
Note that, if the administrator on this page control the WEB services (such as closing WEB Services) may cause
users to no longer use the WEB page, then you can log switches by other means and to control the use of WEB
service allows users to WEB page (such as the Open the WEB service).
DG-GS1528HP/C User Manual
15
Figure 12 Security management page
(5)Configure the current page
Figure 13 is the current configuration page. the user can view the current configuration of the switch on this page.
Save key is to store the current system configuration in the configuration file. Because the storage operation requires
erase& write FLASH chips, which take up some time. When the user was configured on the page and hope to restart
the switch from using these configurations are not lost, you must exit the page before the current configuration page,
click the Save button.
Figure 13 the current configuration page
DG-GS1528HP/C User Manual
16
(6)Configuration page
Figure 14 is profile configuration page. This page allows users to view the system's initial configuration. The initial
configuration is actually the configuration file in the FLASH, when the configuration file does not exist in FLASH, the
system starts using the default configuration. Delete key to delete the configuration file in the FLASH. Click the Delete
button, will pop up a dialog box , that will prompts the user sure to delete the configuration file or not, according to the
dialog box to determine if it's ok, otherwise click Cancel button. Download button is used to download a configuration
file to the PC. Click to download button, will pop up a dialog box, users select Save and save the configuration file
directory path. Download the configuration file names are as switch configuration.
Figure14 Configuration file page
(7)File upload page
Figure 15 is a file upload page, through this page a user can upload a configuration file and mapping files to the
switch. Click the Browse button to select the upload configuration file or image file in the directory path on the PC.
Click Upload button to upload a configuration file or image file, configuration file extension must be *. cfg, image file
must be provided by the manufacturer and the file name extension must be *. img. Transmission before the return of
the results page, please do not click on other pages, or restart the switch; otherwise, the file transfer will lead to failure
caused by system crashes.
DG-GS1528HP/C User Manual
17
Figure 15 File Upload Page
(8)System reset page
Figure 16 is system reset page, through this page users to restart the switch. When you click on Restart button,
will pop up a dialog box that prompts the user to determine whether or restart the switch, If it is determined according
to OK button, otherwise click Cancel button. Restart will no longer open the Web page.
Figure16 System reset page
DG-GS1528HP/C User Manual
18
3.
Port Configuration
(1)Port configuration / port -display page
Figure 17 is the port configuration / port -display page. Users can enable or disable the port to the page, set the port
speed, or View all ports of the basic information.
To set a specific port, users need to select the appropriate port name on port drop-down menu. The default port
status is up, can select the drop-down menu -down to disable the port. Users can also choose to set the speed of the
drop-down menu to set the speed of the port, such as the mandatory half-duplex port 10M (half-10) and so on. On this
page the user can view all ports other basic information.
Figure 17 port configuration and port - display page
(2)Port Statistics Page
Figure 18 is the port statistics information page. To view a particular port, users need to select the appropriate port
name in the port drop-down menu. Users can view the statistics information of send and receive packets on this page.
DG-GS1528HP/C User Manual
19
Figure 18 Port Statistics Page
(3)Flow control page
Figure 19 is the flow control page. Users can enable and disable each port’s send and receive flow control
through this page.
Flow control by sending the side of the drop-down on or off to open or close the sending side of flow control, flow
control through the receiving side of the drop-down on or off to open or close the receiver-side flow control, while on
and off also shows the port to send side and receiving-side flow control is turned on or off.
Figure 19 Flow control page
DG-GS1528HP/C User Manual
20
(4)Broadcast storm control page
Figure 20 is the Broadcast Storm Control page. This page is used to do the suppression for configure port
broadcast packets, multicast packets and DLF packet.
From the Port drop-down bar select to configure ports. Through the on and off key to open and close the port
broadcast suppression, multicast, DLF inhibition and suppression. Inhibition rate is used to configure the port inhibition
speed, range 1-1024000, unit Kbits. The inhibition rate of the same port broadcast suppression, multicast and DLF
inhibition is the same.
Figure 20 Broad cast Storm control Page
(5)Port speed limits page
Figure 21 is the port speed- limit page. This page is used to configure the port ‘send and receive rate
From the Port drop-down bar select the configure ports. Bandwidth control of the send data packets is used to
configure and display the bandwidth control , the range is 1-1024000, unit kbits, enter into force after the key press
applications. If the port is not configured bandwidth control, shown as off. Cancel button is used to cancel the
corresponding data packet to send bandwidth control. Receiving data packets is used to configure and display the
bandwidth control of receive data packets control , the range is 1-1024000, unit kbits, enter into force after the key
press applications. If the port is not configured bandwidth control, shown as off. Cancel button is used to cancel the
corresponding receiving data packets bandwidth control
DG-GS1528HP/C User Manual
21
Figure 21 Port speed limit page
(6)Port protection page
Figure 22 is the Port protection page. This page is used to configure the port for the protection port.
If the port is configured as a protected port, the ports cannot exchange the data with each other , protected port only
with non-protected port for data exchange.
Figure 22 protected port page
DG-GS1528HP/C User Manual
22
(7)Port Learning restrain page
Figure 23 is the port learning restrain page. This page used to restrict the port can learn of the MAC address of the
number, range is 0-8191. The default value is 8191, also is the maximum that the port is not configured the learning
restrain.
Figure 23 Port Learning restrain page
(8)Port Trunking configuration page
Figure 24 is the port trunking configuration page,. This page allows the user to configure the port trunking. This
page consists of four parts: port trunking ID selection, port trunking method selection, configurable ports and group
members port.
To create or modify the port trunking, the user need to select a port trunking ID, port trunking ID from 1 to 3. The
user clicks the list box the appropriate port trunking ID, the port trunking of information displayed in the group port. To
create a Trunk group, select the appropriate ID in the port trunking ID, click the button "Trunk ID Settings." To set the
port trunking method, select one port trunking method, click the button "polymerization Settings." To increase the
trunking ports, the port can be configured to select the trunking port in the configurable, click on "members of the port
=" "key. Aggregation from the existing port to remove a port group member ports in the trunking port selected, click on
"non-member port" = "key. To delete the entire TRUNK group, then click the "Delete trunk group" button.
In page configuring process, at least one Trunk has been established then polymerization settings can take effect;
configured Trunking method is also applied to all on the Trunk groups; in that already exist on the Trunk can add or
remove Port members ; in the absence of the port members situation can delete a Trunk Group.
Switch provides three kinds of port trunking methods: Based on the source MAC address, based on the purpose
MAC address, based on the source and purpose MAC addresses.
Switch supports maximum 3 groups port trunking, can be configured to a maximum of three Trunk Group, Trunk1
and Trunk2 cannot trunk Gigabit ports, and each group can be aggregated up to the same four attributes port. Trunk3
only be aggregated Gigabit ports, and up to 2 Gigabit ports can be aggregated. Port aggregation method is common
to all of the Trunks.
DG-GS1528HP/C User Manual
23
Figure 24 Port Trunking configuration page
(9)Port mirroring configuration page
Figure 25 is the port mirroring configuration page. The page allows users to configure port mirroring. Port
mirroring through the mirror port to monitor the data packets of being mirrored output port and the data packets of
being mirrored input port. mirroring Port can only choose one, being mirrored output port and being mirrored input port
can select multiple. This page consists of four components: monitor port, configurable port, monitoring direction and
mirror configuration information. When you start to configure a mirror port ,firstly configure mirroring port from monitor
ports, mirror ports can only have one, and then select the mirror port from the configurable port, select the monitor
direction, and press the application key to entry into force, the result will be displayed in the mirrored configuration
information.
When choose RECEIVE in direction of monitor, said monitor data packets received, TRANSMIT, said monitor
data packets sent, BOTH that monitor all data sent and received packets, NOT_RECEIVE to cancel monitoring
received data packets, NOT_TRANSMIT to cancel monitor send data packets, NEITHER cancels monitor data
packets received and sent, that is canceling monitor port.
DG-GS1528HP/C User Manual
24
Figure25 Port mirroring configuration page
4.
MAC binding
(1)MAC binding configuration page
Figure 26 is the MAC binding configuration page. This page is used to achieve the port and MAC address binding.
MAC entries on the page is used to enter the MAC address binding, VLAN ID entry is used to enter the MAC address
of VLAN
Figure 26 the MAC binding configuration page
DG-GS1528HP/C User Manual
25
(2)MAC binding automatic conversion page
Figure 27 is the MAC binding automatic conversion page. This page is used to achieve the port MAC address
auto-binding. Fig Shows the hardware switch on the lay2 the exist port dynamic MAC address and affiliated VLAN.
Can choose one of the entries and convert it into static binding.
Figure 27 the MAC binding automatic conversion page
5.
MAC filtering
(1)MAC filtering configuration page
Figure 28 is the MAC filtering configuration page. This page is used to configure the ports on the MAC address
filtering.
MAC entries on the page is used to enter the MAC address filtering, VLAN ID entry is used to enter the MAC address
affiliated VLAN.
DG-GS1528HP/C User Manual
26
Figure 28 the MAC filtering configuration page
(2)MAC filtering automatic conversion page
Figure 29 is the MAC filtering automatic conversion page. This page is used to achieve the port MAC address
auto-binding.
Shows the hardware switch on the lay2 the exist port dynamic MAC address and affiliated VLAN. Can choose one of
the entries and convert it into static filtering configuration.
Figure 29 the MAC filtering automatic conversion page
DG-GS1528HP/C User Manual
27
6.
VLAN Configuration
(1)VLAN information page
Figure 30 shows the current VLAN information page. This page is read-only page displays the current VLAN
configuration information l, including the VID, state and port members. select VLAN from the drop-down VID, shows
the port information of the Port VLAN members.
A port may not be a member of VLAN, which can be VLAN-tagged or untagged members.The meanings of
characters pls see the following info:
t
Tagged the port is the VLAN tagged member
u Untagged the port is the VLAN untagged member
Figure 30 VLAN information page
(2)Static VLAN configuration page
Figure 31 is the static VLAN configuration page that allows users to create VLAN.
If you want to create a new VLAN, the user input VID on activity line, ranging from 2 to 4094. VLAN name is
generated depend on VLAN ID and cannot be modified. Click Apply button, then the list box displays the user-created
VLAN's VID and VLAN name. Switch by default created VLAN1, and VLAN1 cannot be removed
If you want to delete a VLAN, the user needs to click the appropriate VLAN of the list box. The VLAN will be
displayed in the activity line, click the Remove (Delete) key to delete the VLAN, the same time, the information of the
VLAN to remove from the list box.
DG-GS1528HP/C User Manual
28
Figure 31 the static VLAN configuration page
(3)VLAN port configuration page
Figure 32 is a VLAN port configuration page, which is used to configure the VLAN port configuration and display
results. This page mainly consists of eight parts: port, mode, all current VLAN, port-owned VLAN, key "default VLAN
=>"," tagged =>"," untagged =>" and "non-members" =. "
Port is defined a designated port that will configure the VLAN
Access Mode designates the VLAN mode as the ACCESS mode, Under this mode, the port default VLAN is the
untagged member of VLAN1, the port's default VLAN is 1. Hybrid specified port VLAN mode HYBRID model, in this
mode, the port default VLAN is the untagged member of VLAN1, the port's default VLAN is 1. Trunk specified port
VLAN mode, in which the port VLAN mode, In trunk mode, the default is VLAN1 a tagged member of the port's default
VLAN is 1.
All current VLAN that has been created VLAN, also it’s can be configured VLAN, the user from the list select
VLAN, can be multiple-choice.
VLAN Port-owned shows the results of VLAN port configuration, [p] indicates that the port VLAN is the default
VLAN, [t] that the port is a VLAN tag members, [u] that the port is not tagged VLAN member. When you remove VLAN,
the user from the list, select the VLAN, can be multiple-choice.
Button "default VLAN =>" to configure port the default VLAN, selected one VLAN from the current all the VLAN.
Button "tagged =>" Configured port is designated as a tagged member of VLAN, selected one or more VLAN from
the current all VLAN.
Button "untagged =>" Configure VLAN port is a designated member of the untagged, selected one or more VLAN
from the current all VLAN.
Button "non-members <= to delete the port from the specified one or more of the VLAN ,no longer a member of the
VLAN, from the port affiliated VLAN to selected one or more VLAN.
DG-GS1528HP/C User Manual
29
Figure 32 The VLAN port configuration page
7.
SNMP Configuration
(1)SNMP share body configuration page
Figure 33 is a shared body of SNMP configuration page that allows users to configure the switch common body's
name and read and write access, A total of 8 entries can be configured
By default, the switch there is a share name as public, the common body is read-only access. With this
correspondence, the activities of this page is only one entry, shared body names are public, access is read-only
access. When the switch through SNMP for network management, you need to configure a read-write permissions to
the shared body.
DG-GS1528HP/C User Manual
30
Figure 33 a shared body of SNMP configuration page
(2)TRAP target configuration page
Figure 34 is the TRAP target configuration page that allows users to configure the workstation to receive TRAP
messages as well as the IP address of TRAP protocol packets of some of the parameters.
In the configuration entry, the name used to enter the TRAP name, IP address used to enter the target address,
SNMP version used to select the version of the TRAP packet, if you set successful, it will show in the state to active. If
the configuration was successful, SNMP TRAP functions will take effects in the event of link up or link down, the
switch will automatically send a TRAP packet to the target address.
Figure 34 TRAP target configuration page
DG-GS1528HP/C User Manual
31
8.
ACL Configuration
(1)IP Standard ACL configuration page
Figure 35 is the IP standard ACL configuration page. users can through this page to build ACL standard IP-rule
base. User can select a ACL group number to create one or more rules. In a rule can match only the source IP
address field (with mask). The standard IP rules to control the source IP address packet forwarding.
Figure 35 the IP standard ACL configuration page
Users to configure the rules, the source IP address must be in with a mask, the rule can match the collection of IP
addresses. The address mask is use anti-code , if the rule were to match the IP address range 192.168.0.0 to
192.168.0.255, then the IP address can be
192.168.0.1, and its mask of 0.0.0.255.
Users to configure the rules, each rule must have a filter mode: allow or deny.
The user to create a rule in the group, the system will automatically give the rule a rule number, when to delete a
rule in the group 1 rules, other rules remain unchanged, the system will automatically give the rule a rule group
sort. If the user wants to delete the entire rule set, you can first select all, then click the delete key.
DG-GS1528HP/C User Manual
32
(2)IP Extended ACL configuration page
Figure 36 is the IP extended ACL configuration page. The extended IP group is an extension of the standard IP
rules. Control the packet forwarding via source IP, Destination IP, IP protocol type and service port.
Figure 36 the IP Extended ACL configuration page
(3)MAC IP ACL configuration page
Figure 37 is the MAC IP ACL configuration page. IP MAC group can be the IP packet source and destination
MAC address and source and destination IP address control.
DG-GS1528HP/C User Manual
33
Figure 37 the IP Extended ACL configuration page
(3)MAC IP ACL configuration page
Figure 38 is the MAC IP ACL configuration page, IP MAC group can be the IP packet source and destination
MAC address and source and destination IP address control.
Figure 38 the IP Extended ACL configuration page
DG-GS1528HP/C User Manual
34
(4)MAC ARP ACL configuration page
Figure 39 is the MAC ARP ACL configuration page. ARP group can be the type of the operation of the ARP
packet, the sender MAC and the sender IP control.
Figure 39 the IP Extended ACL configuration page
DG-GS1528HP/C User Manual
35
(5)ACL information page
Figure 40 is the ACL information page, which displays the current ACL rules configured in all the information.
Figure 40 is the ACL information page
9.
QoS Configuration
(1)QoS Apply Configuration Page
Figure 41 is a QoS Apply configuration page.
Figure 41 QoS Apply configuration page
DG-GS1528HP/C User Manual
36
(2)QoS Schedule Configuration Page
Figure 42 is a QoS Schedule configuration page.
Figure 42 QoS Schedule configuration page
10. IP Basic Configuration
(1)VLAN Interface Configuration Page
Figure 43 is a VLAN interface configuration page, users can configure the VLAN interface through this page,
delete VLAN interfaces, configure the interface IP address, remove the interface IP address, and view interface
information. VLAN already exists can only be set when the interface can only be configured on the interface set
interface address.
DG-GS1528HP/C User Manual
37
Figure 43 VLAN interface configuration page
Switch in the default have a VLAN1 interface, the interface cannot be deleted. One can only configure a VLAN
interface.
(2)ARP configuration and display page
Figure 44 is the ARP configuration and display page, this page can display all of the information of the ARP table
switch, while users can configure a static ARP entries on this page, delete ARP entries, and revised the dynamic ARP
table entry to a static ARP table entry.
When a user configures a static ARP entry, the need to enter the IP address and MAC address, MAC address
must be a unicast MAC address, and then click Add button.
When a user delete an ARP entry, you can choose to delete an IP-ARP table entry, remove a segment of the
ARP table entry, delete all of the ARP table entry, delete all dynamic ARP table entries and delete all of the static ARP
table entry . For the deletion of an IP-ARP table entries or delete a segment of the ARP table entry required to enter in
the input box, specify the IP address or IP network segment. Then click the Delete button.
When dynamic ARP table entry was revised to a static ARP table entry, you can choose to a particular network
segment or all of the dynamic ARP table entry was revised to a static ARP table entry. For the situation to a network
segment is required in the input box, enter the specified network segment. Finally click apply button.
DG-GS1528HP/C User Manual
38
Figure 44 the ARP configuration and display page
(3)Host Static Routing configuration page
Figure 45 is the host static route configuration page, the user can through this page to add, delete static routing
switch hosts. By default, the switch is not configured to host a static route, the user can configure the default route
through this page, that is the purpose of address / subnet prefix is 0.0.0.0 / 0 routing
Figure 45 the host static route configuration page
DG-GS1528HP/C User Manual
39
11. Certification. Authorization. Accounting (AAA) configuration
(1)Radius Configuration Page
Figure 46 is the Radius configuration page, users can configure the Radius-related information, you can set
information includes:
1. Be sure to set the Radius server's IP address before doing authentication and accounting in this field,
2. Optional Radius server IP address, if there is spare Radius server can set this field.
3. Authentication UDP port, the default value is 1812, the user generally do not need to modify this field.
4. whether to activate , the default is to start, and when you do authentication and accounting in general to
start charging.
5. Accounting UDP port, the default value is 1813.
6. Shared secret key is used to set the shared encryption password between the switch and the Radius
server, so be sure to set the authentication and accounting in this field, and with the same settings on the
Radius server.
7. Vendor-specific information, the users typically do not need to modify this field.
8. NAS ports, NAS port type, NAS type of service, these three values do not change in general.
9.Wether to on or off the roaming feature of Radius.
Figure 46 the Radius configuration page
(2)802.1x Configuration Page
Figure 47 is the 802.1x configuration page, users can configure 802.1x related information on this page,
including:
1. Whether to activate the 802.1x protocol, when doing authentication and accounting must be to start
802.1x protocol.
2. Switch is to adopt a common authentication method or the expansion of authentication.
3. Whether to open re-authentication function, the default is not open .When you do authentication and
accounting based on the actual circumstances. Open the re-authentication feature will make users more
reliable when using the authentication and accounting, but it will slightly increase the network traffic.
4. Setting re-certification time interval, only to re-open the case of authentication to be valid, the default is
3600 seconds, when you do authentication and accounting based on the actual situation to set the value, but
the value is not too small.
5. Quiet Period Timer, users typically do not need to modify this field.
6. Tx-Period Timer, users typically do not need to modify this field.
DG-GS1528HP/C User Manual
40
7. Server timeout timer, users typically do not need to modify this field.
8. Supplicant timeout timer, users typically do not need to modify this field.
9. Max Request number, users generally do not need to modify this field.
10. Showing Reauth Max size.
11. Client Version, the client version number.
12.Check Client, whether the certification passed then examine the client's regular flow of packets.
Figure 47 the 802.1x configuration page
(3)802.1x port configuration page
Figure 48 is the 802.1x port configuration page, the user through this page to configure the support 802.1x port
mode and hosts the largest, at the same time you can view each port 802.1x configuration. 802.1x port model includes
four types: N / A State, Auto state, Force-authorized state and Force-unauthorized state. When a port needs to do
802.1x Authentication, need to set Auto state, if not do authentication to access the network, to set N / A state, the
other two states are rarely used in practical applications.
DG-GS1528HP/C User Manual
41
Figure 48 the 802.1x port configuration page
Doing 802.1x authentication, port access, the default maximum host number is 100, the user can modify this field,
the biggest support to the 100.
(4) 802.1x user authentication information page
Figure 49 is a 802.1x user authentication information page, the user can see through this page, under a certain port
access for all users of the state information,
Figure 49 802.1x user authentication information page
DG-GS1528HP/C User Manual
42
12. Spanning Tree Protocol configuration
(1) MSTP global configuration page
Figure 50 is the MSTP global configuration page, through which you can configure some MSTP related
information, mainly including:
Whether to enable MSTP.
Configure the bridge priority. Devices with lower priority are more likely to be the root bridge.
Enable BPDU filtering function on the port in the port fast bpdu-filter default state.
Enable BPDU guard function on the port in the port fast bpdu-guard default state.
Configure the forwarding delay.
Configure the interval for sending MSTP Hello packets.
The err disable mechanism is started. When a port that starts a BPDU guard receives a BPDU, it starts the
error disable timer. error disable restarts this port after the configured timeout.
Configure error disable timeout time.
Configure the number of seconds the switch waits to receive spanning tree configuration information before
triggering a reconfiguration.
Configure the number of hops specified before a BPDU is dropped in a domain.
Start or shut down and cisco compatible spanning tree protocol.
Figure 50 MSTP Global Configuration Page
DG-GS1528HP/C User Manual
43
(2) MSTP port configuration page
Figure 51 is the MSTP global configuration page. Through this page, you can configure some MSTP related
information, mainly including:
Select the port to be configured.
Configure a port as a portfast port to enable the port from the blocking state to the forwarding state,
bypassing the listening and learning states.
Open the BPDU filter on the selected port.
Enable BPDU guard on the selected port.
Enable the root guard function, and do not accept BPDU packets with a higher priority than the bridge.
Specify the switch as the root switch.
Configure the connection type. point-to-point: The type of connection is point-to-point, allowing fast transition
of the port status. shared: Connection type is shared, does not allow rapid conversion of port status, to go
through the calculation process of 802.1D to determine the status of the port.
Configure the cist priority of the interface. Range 0-240, can only be a multiple of 16. The default is 128.
Configure the cist path cost. Range 1-200000000. The default is 20000000. Lower path costs are more likely
to be roots.
Configure the type of protocol packets to be sent.
Figure 51 MSTP Port Configuration Page
DG-GS1528HP/C User Manual
44
(3) MSTP configuration information page
Figure 52 is the MSTP configuration information page, through which you can view some MSTP related
information
Figure 52 MSTP Configuration Information page
13. IGMP SNOOPING configuration
(1) IGMP SNOOPING configuration page
Figure 53 is the IGMP SNOOPING configuration page, through which you can start IGMP SNOOPING.
Figure 53 IGMP SNOOPING configuration page
DG-GS1528HP/C User Manual
45
(2) IGMP SNOOPING information page
Figure 54 is the IGMP SNOOPING information page, which allows users to view some information about IGMP
SNOOPING.
Figure 54 IGMP SNOOPING Information page
DG-GS1528HP/C User Manual
46
14. GMRP configuration
(1) GMRP Global Configuration Page
Figure 55 shows the GMRP global configuration page. Users can enable GMRP through this page.
Figure 55 GMRP Global Configuration Page
(2) GMRP port configuration page
Figure 56 shows the GMRP port configuration page. You can use this page to enable the GMRP port and view
the port information.
Figure 56 GMRP Port Configuration Page
DG-GS1528HP/C User Manual
47
(3) GMRP state machine page
Figure 57 is the GMRP state machine page. Users can view the GMRP state machine information through this
page.
Figure 57 is the GMRP state machine page
15. EAPS configuration
(1) EAPS configuration page
Figure 58 is an EAPS configuration page, through which you can configure some EAPS related information,
including:
Select an EAPS ring number.
Configure the operating mode of an EAPS Domain.
Configure Primary Port of EAPS Domain.
Configure Secondary Port of EAPS Domain.
Configure a control VLAN for EAPS Domain.
Add one or more protected VLANs of the EAPS Domain.
Configure an EAPS Domain to periodically send HEALTH packets. Hello-timer must be less than fail-time.
Set the fail-period timer of one EAPS domain to expire.
Enable or disable compatibility with Extreme devices.
Whether to enable
DG-GS1528HP/C User Manual
48
Figure 58 EAPS Configuration Page
(2) EAPS information page
Figure 59 is an EAPS information page, through which users can view some EAPS related information.
Figure 59 EAPS information page
DG-GS1528HP/C User Manual
49
17、RMON configuration
(1) RMON statistics group configuration page
Figure 60 shows the RMON statistics group configuration page. You can use this page to configure the RMON
statistics group. Select a port from the drop-down list to view/configure the RMON statistics group configuration for this
port. When not configured, the index number is 0, fill in the correct index number (range 1 to 100), the owner is
optional, you can configure RMON statistics group for the port. The statistics table shows the port statistics from the
successful configuration.
Figure 60 RMON statistics group configuration page
(2) RMON history group configuration page
Figure 62 shows the RMON history group configuration page. You can configure the RMON history group through
this page. Select a port from the drop-down list to view/configure the RMON history group configuration for this port.
When not configured, the index number is 0, fill in the correct index number (range is 1 to 100), interval, request
Buckets, the owner is optional, you can configure the RMON history group for the port. Interval refers to the time
interval in seconds that the data is collected. The range is 1-3600. The bucket is the allocated storage size and it
indicates how many records are stored. The range is 1-100. The statistics table shows historical data that has been
collected since the configuration was successful.
DG-GS1528HP/C User Manual
50
Figure62 RMON history group configuration page
(3) RMON alarm group configuration page
Figure 62 shows the RMON alarm group configuration page. You can use this page to create or modify an RMON
alarm group. Select a configured alarm group from the drop-down list to view/configure its information. Select New to
create it. The index number range is from 1 to 60, and the interval range is from 1 to 3600. In seconds, the monitoring
object must fill in the MIB node. The comparison method can choose absolute (absolute value) or delta (change
amount). In addition, the upper and lower limit valves must be filled in. Value, event index, owner is optional. The
alarm value is read-only and shows the sampled value when the alarm was last issued. The event index refers to the
index number of the RMON event group and must be configured in advance.
Figure 62 RMON alarm group configuration page
DG-GS1528HP/C User Manual
51
(4) RMON event group configuration page
Figure 63 is the RMON event group configuration page. Users can create or modify RMON event groups through
this page. Select a configured event group from the drop-down list to view/configure its information. Select New to
create it. The index number range is from 1 to 60. The description is a character string. Actions can select none (no
operation), log (log), snmp-trap (trap trap) or log-and-trap (log and Trap alarm ), Community names do not work in this
device, owners are optional. The last send time is read-only, showing the last time the event was sent.
Figure 63 RMON Event Group Configuration Page
DG-GS1528HP/C User Manual
52
18、Cluster configuration
(1) NDP configuration page
Figure 64 shows the NDP configuration page. You can use this page to configure NDP. The configurable
information includes: selecting the port, enabling the NDP function of the port, enabling the global NDP function, the
interval for sending NDP packets, and the aging time of the NDP packets on the receiving device.
For port selection, you can select the port as required and enable the port NDP function. For NDP to operate
normally, both global and port NDP must be enabled at the same time.
Set the aging time of the NDP packets sent by the local device to the receiving device. The valid time range is 1-
4096 seconds. The default value is 180 seconds.
Set the interval for sending NDP packets. The valid time range is 1-4096 seconds and the default is 60 seconds.
Figure 64 NDP configuration page
(2) NTDP configuration page
Figure 65 shows the NTDP configuration page. You can use this page to configure NTDP. The information that
can be set includes: selecting the port, enabling the NTDP function of the port, enabling the global NTDP function, the
range of the topology collection, the time interval of collecting the regular topology, the delay time of the first port
forwarding the packet, and the forwarding of the packet by other ports.
For port selection, you can select the port as required and enable the NTDP function on the port. For NTDP to
operate normally, both global and port NTDP must be enabled.
The range of topology collection is configured. The valid range is 1-6. In the default configuration, the maximum
number of hops from the most distant device to the topology collection device is 3.
Set the interval for collecting the topology collection. The valid range is 0-65535 minutes. The default
configuration is 1 minute.
Set the delay for forwarding packets on the first port. The valid range is 1-1000 milliseconds. The default value is 200
milliseconds.
Sets the delay for forwarding packets on the first port. The valid range is 1 to 100 milliseconds. The default value
is 20 milliseconds.
DG-GS1528HP/C User Manual
53
Figure 65 NTDP configuration page
(3) Cluster Configuration Page
Figure 66 is the cluster configuration page. Users can configure the cluster and view the cluster member table
through this page. The information that can be set includes: enabling the cluster function, configuring the management
VLAN, the address pool of the cluster, the interval for sending handshake packets, the effective retention time of the
device, the name of the cluster, the way to join the cluster, and deleting the cluster.
To enable the cluster function, you must enable the cluster function before the cluster function can run normally.
Configure a management VLAN. The valid range is 1-4094. The default configuration is vlan1.
Configure a private IP address range for member devices in the cluster. The valid range of ip addresses is 0.0.0.0
to 255.255.255.255. The valid range of the mask length is 0 to 32.
Set the interval for sending handshake packets. The valid range is 1-255 seconds. The default is 10 seconds.
Configure the device's effective retention time. The valid range is 1-255 seconds and the default is 60 seconds.
To set up a cluster, you need to configure the cluster name and choose to join the cluster. There are manual and
automatic joining methods. After establishing a cluster, you can automatically switch to manual, but you cannot
manually switch to automatic. Manual mode can change the cluster name.
After a cluster is established, member devices and candidate devices can be viewed in the cluster member table.
You can delete member devices or add candidate devices to member devices according to roles.
DG-GS1528HP/C User Manual
54
Figure 66Cluster Configuration Page
19 Log management
(1) Log information page
Figure 67 is the Log information page. Users can enable and view various log information through this page.
Figure 67 Log Information Page
DG-GS1528HP/C User Manual
55
Critical: Output critical level information.
Debugging: Outputs debug level information.
Informational: Output information level debugging information.
Warning: output warning level debugging information.
ALL: output all log information
20、PoE port configuration
(1)PoE port Configuration Page
Figure 68 is the PoE port configuration / PoE-display page. Users can enable or disable the port's PoE
function to the page, or View all ports of PoE information.
Information can be seen in the following tables:
1. Status: Enable means PoE function is available;Disable means PoE function is close.
2. Operation: Displays the PoE ports ON or OFF
Figure 68 the PoE port configuration page