Video Intercom Indoor Station·Quick Start Guide

i Quick Start Guide ©2019 Hangzhou Hikvision Digital Technology Co., Ltd. This quick start guide is intended for users of the models below: Series Model Indoor Station (6-Series) DS-KH6310-W DS-KH6310 DS-KH6310-WL DS-KH6210-L Indoor Station (8-Series) DS-KH8301-WT DS-KH8300-T It includes instructions on how to use the Product. The software embodied in the Product is governed by the user license agreement covering that Product. About this Manual This Manual is subject to domestic and international copyright protection. Hangzhou Hikvision Digital Technology Co., Ltd. (“Hikvision”) reserves all rights to this manual. This manual cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision. Trademarks and other Hikvision marks are the property of Hikvision and are registered trademarks or the subject of applications for the same by Hikvision and/or its affiliates. Other trademarks mentioned in this manual are the properties of their respective owners. No right of license is given to use such trademarks without express permission. Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, REGARDING THIS MANUAL. HIKVISION DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF THE MANUAL, OR THE CORRECTNESS, ACCURACY, OR RELIABILITY OF INFORMATION CONTAINED HEREIN. YOUR USE OF THIS MANUAL AND ANY RELIANCE ON THIS MANUAL SHALL BE WHOLLY AT YOUR OWN RISK AND RESPONSIBILITY.

Video Intercom Indoor Station·Quick Start Guide

ii TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, SECURITY BREACHES, OR LOSS OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE OF OR RELIANCE ON THIS MANUAL, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY OR CERTAIN DAMAGES, SO SOME OR ALL OF THE ABOVE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. Support Should you have any questions, please do not hesitate to contact your local dealer.

Video Intercom Indoor Station·Quick Start Guide

iii Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU. 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (A)/NMB-3(A) standards requirements.

Video Intercom Indoor Station·Quick Start Guide

iv Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Warnings and Cautions: Warnings: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage. Warnings  The working temperature of the device is from -10º C to 55º C.  All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region.  Please use the power adapter, which is provided by normal company. The power consumption cannot be less than the required value.  Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard.  Please make sure that the power has been disconnected before you wire, install or dismantle the device.  When the product is installed on wall or ceiling, the device shall be firmly fixed.  If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center.  If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.) Cautions  Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).  Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation.  The device cover for indoor use shall be kept from rain and moisture. Warnings Follow these safeguards to prevent serious injury or death. Cautions Follow these precautions to prevent potential injury or material damage.

Video Intercom Indoor Station·Quick Start Guide

v  Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger).  Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time.  Please use the provided glove when open up the device cover, avoid direct contact with the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover.  Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents.  Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs.  Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer.

Video Intercom Indoor Station·Quick Start Guide

vi Table of Contents 1 Getting Started ............................................................................................. 1 1.1 Activate Indoor Station ............................................................................................................. 1 1.2 Set SIP Sever ............................................................................................................................. 2 1.2.1 Set Private SIP .................................................................................................................... 2 1.2.2 Set Standard SIP ................................................................................................................ 3 1.3 Set Network .............................................................................................................................. 5 1.3.1 Set Indoor Station Network Parameters ............................................................................ 5 1.3.2 Set Linked Device IP ........................................................................................................... 6 1.4 Set Indoor Station No. .............................................................................................................. 8

Video Intercom Indoor Station·Quick Start Guide

1 1 Getting Started  Here the local operation of indoor stations with touch screen is taken as example.  The DS-KH6210-L should be operated with physical keys. The SOS key works as a return key; the Unlock key works as direction keys ▲and◄ to turn up and left; the Live View key works as direction keys ▼and► to turn down and right; and the Management Center key works as a confirm key. 1.1 Activate Indoor Station You can configure and operate the indoor station only when you activate it. You must create a password to activate the indoor station for your first time usage and when it is not activated. Steps: 1. Power on the device to enter the activation page automatically. Figure 1-1 Activation Interface (DS-KH8301-WT) 2. Create a password and confirm it. 3. Tap OK to activate the indoor station.

Video Intercom Indoor Station·Quick Start Guide

2 STRONG PASSWORD RECOMMENDED– We highly recommend you to create a strong password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 1.2 Set SIP Sever A SIP server connection is required and necessary for the indoor station to guarantee the connection between the indoor station and the management center (master station) in the same video intercom system. 2 types of SIP protocol are available for the indoor station: Private Protocol, and Standard Protocol.  Rebooting the indoor station is required when you switch the SIP protocol between the private SIP protocol and the standard SIP protocol.  All linked device IP should be configured again after you change the SIP protocol type.  The indoor extension does not support SIP server settings. 1.2.1 Set Private SIP The SIP server IP is required for you to set when you select Private Protocol, and the SIP IP must be in the same network segment with the intercom devices in the system. Steps: 1. Tap Settings -> Configuration -> SIP Settings to enter SIP Settings page. 2. Select Private Protocol.  Default admin password is 888999.  The default SIP protocol is private protocol.

Video Intercom Indoor Station·Quick Start Guide

3 Figure 1-2 SIP Protocol Selection 3. Tap Device to enter the device management page. Figure 1-3 Device Management 4. Tap SIP Server, and enter the IP address of the SIP server. 5. Tap to save. 1.2.2 Set Standard SIP With the standard SIP, your indoor station can connect to any intercom device, software client, and phones which also support the standard SIP. Before you Start:

Video Intercom Indoor Station·Quick Start Guide

4 Make sure you have added a VoIP account in the standard SIP server. Steps: 1. Tap Settings -> Configuration -> SIP Settings to enter SIP Settings page. 2. Select Standard Protocol.  Default admin password is 888999.  The default SIP protocol is private protocol.  Rebooting the indoor station is required when you change to Standard Protocol from Private Protocol. Figure 1-4 SIP Protocol Selection 3. Set VoIP account.  The account you entered here must be the same with the account you added in the standard SIP server.  The phone number should be a numeric, which is up to 16 digits. And the phone number will be the number you dial when you want to call the indoor station via standard SIP.

Video Intercom Indoor Station·Quick Start Guide

5 Figure 1-5 Set VoIP Account 4. Tap to save the standard SIP settings. 1.3 Set Network 1.3.1 Set Indoor Station Network Parameters Network connection is mandatory for the use of the indoor station. Set the network parameters after activating the indoor station. What's more, the indoor station can work normally in an intercom system only when its IP address is in the same network segment with other devices in the same system. The indoor station’s default IP address is 192.0.0.64. Two ways are available for you to set indoor station's IP address: DHCP, and set IP address manually. Steps: 1. Tap Settings -> Configuration -> Network to enter the network settings page. Default admin password is 888999.

Video Intercom Indoor Station·Quick Start Guide

6 Figure 1-6 Network Settings 2. Enable DHCP, then the indoor station can search and get an IP address automatically. Skip the following steps if you have set an IP address for the indoor station by DHCP function. 3. Set the IP address manually. 1) Tap to pop up the network parameters settings dialog box. Figure 1-7 Network Settings Box 2) Enter IP address, subnet mask, and network gateway. 3) Tap OK. 1.3.2 Set Linked Device IP Linked network parameters refers to the network parameters of devices (like door station, doorphone, master station, center, etc.), to which the indoor station is linked. Linked devices for the indoor station refers to door station, center, master station, and doorphone. With the private SIP protocol, intercom can be realized only when all these devices are in the same network segment with the indoor station.

Video Intercom Indoor Station·Quick Start Guide

7 With the standard SIP protocol, intercom can be realized when all these devices support the standard SIP protocol.  The doorphone does not support adding with the standard SIP protocol.  Here take door station network settings as example. Steps: 1. Tap Settings -> Configuration -> Device to enter the device management page. Default admin password is 888999. Figure 1-8 Device Management (Private SIP) Figure 1-9 Device Management (Standard SIP)

Video Intercom Indoor Station·Quick Start Guide

8 2. Tap Main Door Station to pop up the device information dialog box. Figure 1-10 Device Information Dialog Box 3. Select a door station type based on your actual door station type, and set the door station IP address. 1.4 Set Indoor Station No. Indoor station No. and the indoor extension No. are numbers, which can be dialed by other devices to call the indoor station and the indoor extension in an intercom system. The indoor station No., is composed of the floor No. and the room No. For example, the indoor station No. 401 refers to the room 1 on the fourth floor, and the indoor station No. 512 refers to the room 12 on fifth floor, and the indoor station 2302 refers to the room 2 on the 23rd floor. The indoor extension No. Should be a numeric from 1 to 5. Up to 5 indoor extensions can be set for 1 indoor station. The floor No. can be set as 0. Steps: 1. Tap Settings -> Configuration -> Local Info to enter the indoor station No. settings page. Default admin password is 888999. 2. Select Indoor Station to set the indoor station No. (Room No.) and the floor No. For Example: When set the Room No. as 2, and the Floor No as 2, then the indoor station No. is 202.

Video Intercom Indoor Station·Quick Start Guide

9 Figure 1-11 Set Indoor Station No. 3. Select Indoor Extension to set the indoor extension No. and the room name. For Example: Set the indoor extension No. as 1, and the room name as Hello Room. What to do next You can press 201 on the door station to call the indoor station, and press 1 on the indoor station to call indoor extension.