ETU-911A, ETU-912A, AND ETU-914A

RATE SELECTABLE G.SHDSL ETSI TERMINATION UNITS WORLDDSL G.S QUICK INSTALLATION

ETU-911A, ETU-912A, AND ETU-914A

The ADC® WorldDSL™ G.S ETU-911A, ETU-912A, and ETU-914A ETSI Termination Units (ETUs) are rate selectable Single-pair High-speed Digital Subscriber Line (SHDSL) cards housed in enclosures with rear-panel interface and power connectors for use as standalone desktop units. The SHDSL cards conform to ITU-T recommendation G.991.2 for SHDSL (referred to as G.SHDSL). Rate selectable G.SHDSL offers an extended transmission range and spectral compatibility with leading DSL technologies. Transmission ranges vary according to the data rate selected, wire size, and noise environment. At a data rate of 2.048 Mbps with noise, the reach is 2.4 km (1.4 mile) on 0.4 mm wire and 6.8 km (4.2 miles) on 8 mm wire. Reach is significantly greater at lower data rates in reduced noise environments. For details, see the UTU/ETU User Manual, LTPE-UM-3010-xx (which can be downloaded from the ADC website at www.adc.com). The ETUs can be configured as Line Termination Units (LTUs) or Network Termination Units (NTUs). The default configuration is NTU. The NTU-configured ETUs are installed at the customer site. LTU-configured Universal Terminations Units, UTU-911, UTU-912, and UTU-914, are installed in exchange office shelves. To complete the G.SHDSL transmission system, the UTUs and ETUs are interconnected over one pair of twisted-copper wire. The UTUs accept the exchange office payload at their G.703 or Nx64k port and transport the payload to the ETUs at the selected DSL data rate. The DSL data rate is determined by the number of 64 kbps time slots selected by the user. The UTUs and ETUs have a DSL data rate ranging either from 192 kbps to 2.048 Mbps (G.703) or from 192 kbps to 2.304 Mbps (Nx64k). The ETUs require a 50 or 60 Hz power source with a voltage range of 100 to 240 Vac. The ETUs include a power-fail circuit that triggers a user-configured alarm and reports same to the exchange office when an AC power failure occurs. APPLICATION INTERFACE The ETU-911A has an E1 G.703 interface that can be configured for an impedance of 75Ω unbalanced or 120Ω balanced. Data is structured or unstructured according to the G.704 framing standard and, optionally, CRC-4 multiframed according to the G.706 standard. The ETU-912A has an Nx64k serial dataport interface with user-selectable protocols that conform to the V.35, V.36, X.21, or RS-530 (RS-449) standards. The ETU-914A has both an E1 G.703 interface and an Nx64k interface, sharing the SHDSL bandwidth. Use of this product in a manner other than defined in this installation guide may cause damage to equipment or injury to personnel. Falls der Gebrauch von diesem Produkt nicht gemaess der Definition im Installations Handbuch eingehalten wird, besteht die Gefahr, dass Schaden am Geraet oder sogar Koerperverletzungen entstehen koennten.

ETU-911A AND ETU-914A 120/75 OHM

G.703 SWITCH SETTINGS The rear-panel 120/75Ω Selector Switch must be set for 120Ω if using a 120Ω G.703 interface. The default setting is 75Ω. The settings for 75Ω and 120Ω operation are shown in Figure 1. Figure 1. ETU-911A and ETU-914A 120/75Ω G.703 Switch Settings ETU EARTH GROUND CONNECTION To connect the ETU chassis to earth ground: 1 On the ETU rear panel, remove the two hex nuts from the chassis ground lug. 2 Place the ground wire ring-terminal on the chassis ground lug. 3 Secure the ground wire to the ground lug with the two hex nuts removed in step 1. 4 Attach the other end of the ground wire to earth ground. CONTINUED The ETU chassis must be connected to earth ground for protection of the equipment and for personnel safety. Die Geraete Erdung des ETU muss via die Haupt-Erdung (Erdpotential) guarantiert werden, um das Geraet zu schuetzen und die Sicherheits des Personals zu gewaehrleisten. A 12- or 14-gauge solid copper ground wire is recommended. Ω 75 switch settings (default) Ω 120 switch settings 1 2 3 4 1 and 2 = ON 3 and 4 = OFF All switches set to OFF 1 2 3 4 

D25F data port

connector D15F alarm connector D9F SHDSL line connector Power cord receptacle On/off switch Chassis ground lug ETU Front Panel ETU-912A Rear Panel On/off switch D15F 120 G.703 and alarm connector Ω BNC 75 G.703 in and out connectors Ω D9F SHDSL line connector Power cord receptacle 120/75 selector switch Ω D25F data port connector Chassis ground lug ETU-911A Rear Panel ETU-914A Rear Panel Local and remote loopback LEDs and pushbuttons V.24 (RS-232) console port G.703 bridge jack (ETU-911A and ETU-914A only) SHDSL sync and alarm LEDs I/F alarm LED D15F 120 G.703 and alarm connector Ω BNC 75 G.703 in and out connectors Ω D9F SHDSL line connector On/off switch Power cord receptacle 120/75 selector switch Ω Chassis ground lug

REAR-PANEL CABLE CONNECTIONS

Make the following rear-panel cable connections: 1 Connect the cable containing the SHDSL pair to the SHDSL line connector. 2 If the customer equipment uses 75Ω coaxial cable, connect the equipment's output cable to the 75Ω IN connector. Connect the equipment's input cable to the 75Ω OUT connector. 3 If the customer equipment uses 120Ω twisted-pair cable, connect the cable to the 120Ω\ALARM connector. 4 If the customer equipment uses an Nx64k serial interface (V.35, V.36, RS-449, RS-530, or X.21), connect its cable to the DATA PORT connector. 5 If using an external power-fail alarm, fabricate a cable that connects alarm-relay pins 5 (NC), 7 (NO), and 14 (C) of the ALARM connector to the external alarm (the ALARM connector is designated 120Ω\ALARM on ETU-911A and ETU-914A). DSL SELF TEST AND LINK UP The LTU-configured unit holds the configuration settings for both itself and the remote NTU-configured unit. As the two units synchronize, the LTU will configure the NTU. 1 Power up the SHDSL unit. 2 Confirm the following: • The red ALM LED is on and the green SYNC LED flashes once per second as the units self-configure and establish synchronization. • After approximately 60 seconds, the red ALM LED is off, and the SYNC LED is a steady green. The unit is now ready for configuration using the console screen menus displayed on a maintenance terminal at the exchange office. Other LED functions are described in Table 1. Primary protection for the SHDSL line must be provided by the user. Both primary and secondary protection must be provided by the user if the E1 line runs outside of the building. Der primaere Schutz des SHDSL Anschlusses muss von der Benutzerseite aus geregelt werden. Wenn der E1 Anschluss ausserhalb des Gebaeudes installiert ist, muss der primaere und sekundaere Schutz von der Benutzerseite aus geregelt werden. Copies of the UTU/ETU User Manual (LTPE-UM-3010-xx) or this publication can be downloaded from the ADC website at www.adc.com. To order a hard copy, please contact your sales representative.

Front-Panel LED Functions

LED Mode Description SHDSL SYNC Steady green Slow flashing Off SHDSL loop is ready to transmit and receive data. SHDSL loop acquisition is in progress. SHDSL loop is not configured. SHDSL ALM Steady red Pulsing red Off Margin is below set threshold (MAL alarm). Loop attenuation is above set threshold (LAL alarm). Errored seconds count is above set threshold (ESAL alarm). Loss of sync word (LOSW alarm). AC power supply failure (ACPF alarm) at remote ETU. Pulses for every ES on the span. Normal transmit or receive data is in progress. I/F ALM Steady red Blinking red Pulsing red Loss of signal (LOS alarm). Loss of clock (LOC alarm) due to loss of TT clock (Nx64k timing). Loss of external clock (LOC) alarm) when using EXT timing. Loss of frame alignment (LFA alarm). Remote alarm indication signal (RAI alram). Received alarm indication signal (AIS alarm). Pulses for every ES on E1 interface. LOC and REM LPBK LEDs (a) (a) The LOC and REM loopback LEDs are read in unison. LOC REM Off Off No loopbacks are active. Steady yellow Off Local DSL analog loopback is active. Off Steady yellow Remote loopback is active. Blinking yellow Off Local interface loopback is active. Blinking yellow Blinking yellow A loopback away from the local equipment is active.

DNV Certification, Inc.

REGISTERED FIRM ISO 9001/TL 9000 Limited Warranty ADC DSL Systems, Incorporated (“ADC”) warrants that , for a period of sixty (60) months from the date of shipment, the hardware portion of its products will be free of material defects and faulty workmanship under normal use. ADC's obligation, under this warranty, is limited to replacing or repairing, at ADC's option, any such hardware product which is returned during the 60-month warranty period per ADC's instructions and which product is confirmed by ADC not to comply with the foregoing warranty. ADC warrants that, for a period of 90 days from the date of purchase, the software furnished with its products will operate substantially in accordance with the ADC published specifications and documentation for such software. ADC’s entire liability for software that does not comply with the foregoing warranty and is reported to ADC during the 90-day warranty period is, at ADC’s option, either (a) return of the price paid or (b) repair or replace of the software. ADC also warrants that, for a period of thirty (30) days from the date of purchase, the media on which software is stored will be free from material defects under normal use. ADC will replace defective media at no charge if it is returned to ADC during the 30-day warranty period along with proof of the date of shipment. The transportation charges for shipment of returned products to ADC will be prepaid by the Buyer. ADC will pay transportation charges for shipment of replacement products to Buyer, unless no trouble is found (NTF), in which case the Buyer will pay transportation charges. ADC may use reconditioned parts for such repair or replacement. This warranty does not apply to any product which has been repaired, worked upon, or altered by persons not authorized by ADC or in ADC's sole judgment has been subjected to misuse, accident, fire or other casualty, or operation beyond its design range. Repaired products have a 90-day warranty, or until the end of the original warranty period—whichever period is greater. Modifications Any changes or modifications made to this device that are not expressly approved by ADC DSL Systems, Inc. voids the user's warranty. All wiring external to the product should follow the local wiring codes. Trademark Information ADC is a registered trademark and WorldDSL is a trademark of ADC Telecommunications, Inc. Other product names mentioned in this installation guide are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Copyright Information © 2002 ADC DSL Systems, Inc. All rights reserved. Information contained in this document is company private to ADC DSL Systems, Inc., and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of ADC. ADC DSL Systems, Inc. 14402 Franklin Avenue Tustin, CA 92780-7013 Tel: 714.832.9922 Fax: 714.832.9924 Technical Assistance Tel: 800.638.0031 Tel: 714.730.3222 Fax: 714.730.2400 ´,D°¶5T¨ 1236955 June 21, 2002 Product Catalog: ETU-911A ETU-912A ETU-914A Document: LTPE-QI-3155-01