alphatronics AlphaVision Wireless interface Installation Manual

Text of the manual

Alphatronics bv * Watergoorweg 71* 3861MA Nijkerk * Tel.: 033-2459944 * Fax.: 033-2453149 * [email protected]

For use with:

AlphaVision NG, AlphaVision EC (Alpha Easy) and AlphaVision 96 RF MODULE Type module: super heterodyne RF receiver Frequency: 868,95 MHz DATA ID codes: Over 16 million possible combinations Length of transmission: 36 bits Capacity: 8 wireless zones either PowerCode or Code Secure Interface: Can be connected

CONNECTING THE WIRELESS INTERFACE

The alarm system needs to be powered down when you connect the Wireless Interface to the RS-485 bus. By short-circuiting the JP5 pins with a jumper you can temporarily bypass the tamper switch of the Wireless Interface. This is not recommended during normal use as there will be no tamper alarm when the Wireless Interface cas

A enrolling session is required to let the Wireless Interface ‘learn’ the ID codes of the PowerCode detectors and

Code Secure keyfobs. This can be done threw a so-called ‘direct learning’ method on the Wireless Interface. To do so the dipswitches on the Wireless Interface are required during enrolling. A second method is to directly type

When you are finished programming, put the dipswitches 1-4 back to the address settings of the RS-485 bus and

put the slide switches JP2 and JP3 to the AV mode. Finally put dipswitch 8 to OFF. The RS-485 communication with the control panel will be restored. c) Program the associated names for each wireless keyfob into the zone programming of the control pan