Avaya P580 Manual 

Text of the manual

C H A P T E R 1

Installing Avaya P550™/P580/P880/P882 Gigabit Ethernet Modules Overview This document describes the following processes: ■ Gigabit-Speed Modules ■ Compliance Information ■ Software Requirements ■ Power Requirements ■ Installing the Modules ■ Installing GBIC Connectors ■ Installing the Cables Gigabit-Speed Modules This document describes installation and configuration of the following media modules: 50 Series Modules ■ 2-Port, Full-Duplex 1000BASE-X module: 850 nm (SX) and 1310 nm (LX and SLX) - (Layer 2 and Layer 3) ■ 4-Port, Full-Duplex 1000BASE-X module: 850 nm (SX) and 1310 nm (LX and SLX) - (Layer 2) 80 Series Modules ■ 4-Port, Gigabit Interface Card (GBIC) based module: 850 nm (SX), 1310 nm (LX and SLX) and 1550 nm (ELX) (Layer 2 and Layer 3) ■ 8-Port, Gigabit Interface Card (GBIC) based module: 850 nm (SX), 1310 nm (LX and SLX) and 1550 nm (ELX) (Layer 2 and Layer 3)

Please read the following compliance information prior to installing

your Avaya Gigabit Ethernet Module. FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference 2. This device must accept any interference received, including interference that may cause undesired operation. This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet apparell numérique de la classe A respecte toutes les exigences du Régelment sur le matériel brouilleur du Canada. WARNING This is a class A product. In a domestic environment, this product may cause radio interference, in which case you may be required to take adequate measures. Laser Safety Information * Note: This notice applies to devices that contain optical transceiver media modules installed. The transceivers used in this product are Class 1 Laser Products. This product complies with 21 CFR Chapter 1, Subchapter J. Any use other than that specified herein may result in hazardous laser radiation exposure. Unterminated optical receptacles may emit laser radiation. Do not view with optical instruments. This product complies with IEC 60825-1, Safety of Laser Products, Class 1 Laser Product.

The Avaya P550R/P580/P880/P882 80-Series modules require

software of Version 5.0 or higher. Power Requirements In the P550 chassis, each power supply powers approximately four media modules. In the P880 chassis, each power supply powers approximately nine media modules. It takes two power supplies to power a full chassis. Using three power supplies ensures that the system has redundant power capabilities. Use Tables 1 and 2 for the precise power values: Table 1. Power Values for System Devices - 50-Series Modules Table 2. Power Values for System Devices - 80-Series Modules Select Power System from the System > Configuration > group on the web agent window to determine how much power is currently available in your switch. Device Power Used 2-Port Gigabit Module 35 W 4-Port Gigabit Module 55 W Device Power Used 4-Port Gigabit Module 45 W 8-Port Gigabit Module 75 W

Installing the Modules

* Note: All Avaya media modules are hot swappable. You do not need to shut down the switch when adding modules. To install modules in the chassis: 1. Carefully remove the module from its box, leaving the module in its anti-static wrapping. 2. Take appropriate antistatic precautions and carefully remove the module from the antistatic wrap (refer to Chapter 1, “Installation” in the Avaya P550/P580/P880/P882 Multiservice Switch Installation Guide for detailed information on proper antistatic precautions). 3. Open the Ejector Tabs until the stops make contact with the face plate (Figure 1). Figure 1. Installing the Module 4. Insert the module into the chassis (Figure 1). 5. Press on the center of the module as you push it into the chassis. The ejectors snap into place. 6. Push the ejectors into the closed position to complete seating the module (Figure 2).

Figure 2. Closing the Ejector Tabs

7. Tighten the captive screws. As the module powers up, the LEDs should function as described in the module descriptions provided in the Avaya P550/P580/P880/P882 User Guide. In general, the following is observed on a properly- functioning module (Table 3 ): Table 3. Power-up LED Function Module LED Normal Behavior All Modules Module Status Solid green, indicating normal operation. Gigabit Modules TX and RX Solid green, flashing yellow intermittently to indicate traffic Port Solid green, indicating link integrity. HD/FD Solid green, indicating full-duplex operation.

Installing GBIC Connectors

GBIC connectors are only applicable to 80-Series modules. They come in the following types: ■ SX (550m-capable) ■ LX (10km-capable) ■ SLX (25km-capable) ■ ELX (70-100km-capable) Refer to Table 4 and Table for distances and wave lengths. * Note: All Avaya GBIC connectors are hot swappable. You do not need to shut down the switch when adding modules. To install a GBIC connector into a module: 1. Carefully remove the GBIC connector from its packaging, leaving the module in its anti-static wrapping. 2. Take appropriate antistatic precautions and carefully remove it from the antistatic wrap. (Refer to the Avaya P550/P580/P880/ P882 Multiservice Switch User Guide for more information on proper antistatic precautions). 3. Carefully slide the GBIC connector into the module until the side connectors click into place (Figure 3).

Figure 3. Installing a GBIC Connector

Installing the Cables Install the appropriate cables for your network configuration. The Avaya P550/P580/P880/P882 Multiservice Switch supports the following cable type: ■ Fiber cables with SC-type connectors Optical Channel Requirements The optical fiber types that can be used with the Gigabit Ethernet Modules are standard single-mode and multimode optical fibers that conform to the requirements of the following standards. Single-mode Optical Fiber: ■ IEC 60793-2 B1.1 (dispersion unshifted single-mode) or ■ IEC 60793-2 B1.3 (low water peak single-mode) ■ ITU-T Recommendation G.652 –Dispersion Unshifted Fiber

TIA/EIA 492CAAA Dispersion-Unshifted Single-Mode

Optical Fibers or TIA/EIA 492CAAB Dispersion-Unshifted Single-Mode Optical Fibers with Low Water Peak Multimode Optical Fiber: ■ TIA/EIA 492AAAA 62.5/125 micron Multimode Optical Fiber ■ TIA/EIA 492AAAB 50/125 micron Multimode Optical Fiber ■ TIA/EIA 492AAAC 50/125 micron Laser Optimized Multimode Optical Fiber ■ IEC 60793-2-10 type A1a.2 (in preparation) Examples of optical fibers that meet these requirements include (but are not limited to): Single-mode Optical Fiber ■ Corning®SMF-28™ Fiber ■ Corning®SMF-28e™ Fiber ■ OFS Fitel Single-Mode Fiber ■ OFS Fitel AllWave®Fiber ■ Avaya Systimax Single-Mode Fiber Cable Multimode Optical Fiber ■ Corning Infinicor ■ Corning Infinicor SX ■ OFS GigaSPEED ■ OFS LazrSPEED ■ Draka Comteq Max Cap 300

Refer to Table 4 and Table 5 for supported link distances for the

Gigabit Ethernet Modules. Table 4. Supported Link Distances Table 5. Supported Link Distances - GBICs Model Number Wavelength Fiber Type Link Distance (m) M5504- 1000SX M5502- 1000SX M5502R- 1000SX 850 nm 50 µm MMF • 400 MHz*km • 500 MHz*km • 2 to 550 • 2 to 550 62.5 µm MMF • 160 MHz*km • 200 MHz*km • 2 to 220 • 2 to 275 M5504- 1000LX M5502- 1000LX M5502R- 1000LX 1310 nm 50 µm MMF • 400 MHz*km • 500 MHz*km • 2 to 550 • 2 to 550 62.5 µm MMF • 160 MHz*km • 200 MHz*km • 2 to 550 • 2 to 550 9/10 µm SMF 2 to 5000 M5504- 1000SLX M5502- 1000SLX M5502R- 1000SLX 1310 nm 62.5 µm MMF • 160 MHz*km • 200 MHz*km • 2 to 550 • 2 to 550 9/10 µm SMF 2 to 10000 GBIC Part Number Wavelength Fiber Type Link Distance (m) M8001- 1000SX 850 nm GBIC 50 µm MMF • 400 MHz*km • 500 MHz*km • 2 to 550 • 2 to 550 62.5 µm MMF • 160 MHz*km • 200 MHz*km • 2 to 220 • 2 to 275

Table 6 lists the optical fiber specifications for the Gigabit Ethernet

Modules. Table 6. Optical Fiber Specifications a. For the single-mode case, the 0.4 dB/km attenuation for optical fiber cables is defined in ITU-T G.652. M8001- 1000LX 1310 nm GBIC 62.5 µm MMF • 160 MHz*km • 200 MHz*km • 2 to 550 • 2 to 550 9/10 µm SMF 2 to 10000 M8001- 1000SLX 1310 nm GBIC 9/10 µm SMF 2 to 25000 M8001- 1000ELX 1550 nm GBIC 9/10 µm SMF Up to 70,000 to 100,000 GBIC Part Number Wavelength Fiber Type Link Distance (m) Description 62.5 µm MMF 50 µm MMF Type B1.1, B1.3 SMF Unit Nominal fiber specification wavelength 850 850 1310 1550 nm Fiber cable attenuation (max) 3.5 3.5 0.4aor 0.5b See Footnote c dB/km Modal bandwidth (min) 160d or 200d 400d or 500d or 2000e N/A MHz km Zero dispersion wavelength (λ0) 1320 ≤ λ0 ≤ 1365 1295 ≤ λ0 ≤ 1320 1300 ≤ λ0 ≤ 1324 nm Dispersion slope (max) (S0) 0.11 for 1320 ≤ λ0 ≤ 1348 and 0.001(1458 - λ0) for 1348 ≤ λ0 ≤ 1365 0.11 for 1300 ≤ λ0 ≤ 1320 and 0.001(1190 - λ0) for 1295 ≤ λ0 ≤ 1300 0.093 ps / nm2 km

b. For the single-mode case, the 0.5 dB/km attenuation is provided for

Outside Plant cable as defined in TIA 568B.3. Using 0.5 dB/km may not support operation at 10 km. c. Attenuation for 1550 nm links is based on the fiber channel and is specified in IEEE 802.3ae Table 52.14.3. d. Overfilled launch bandwidth per IEC 60793-1-41 or TIA/EIA 455-204. e. Effective modal bandwidth for fiber meeting TIA /EIA-492AAAC when used with sources meeting the wavelength (range) and encircled flux specifications of IEEE 802.3ae Table 52–7. For More Information Refer to the Avaya P550/P580/P880/P882 Multiservice Switch User Guide for more information concerning module configuration options.