Installation and Operating Instruction for B.E.G.-Occupancy detectors PD4-M-DIM-C-SM/-FC

LUXOMAT® PD4-M-DIM-Corridor GB 4. DIP switch functions DIP- switch ON OFF 1 Semi automatic mode Fully automatic mode 2 LED OFF LED ON 3 Corridor mode Standard mode DIP OFF ON 1 2 3 3. Position DIP-switches The DIP switch set- tings are overriden using the remote control. Surface mounting 1 2 3 OFF ON VA LED HA COR ON OFF DIP 7. Option: Wall bracket for remote control IR-PDim IR-PDim 5. Putting into operation / Settings Initialization In the first 60 seconds after connecting the power supply the LUXOMAT® PD4-M-DIM-C will go through a self test cycle. During this time the device doesn´t respond to movement, but will stay on the status depending on the selected initialization mode on or off (INI OFF or ON). Warning: In the Ini-OFF mode, does not switch on lights at power start up. After 60 seconds, detector would switch on lights on upon detecting movement. Follow-up time for light control The time can be set infinitely variably at between 1 and 30 minutes. Symbol TEST: Test mode (Every movement switches on the light for a period of 1 second, switching it off for a period of 2 seconds after that regardless of the level of brightness) Twilight-switch for light control (relay 1) The switch-on value for the light can be set at between 10 and 2000 Lux. Using the rotary control, the luminance set points can be set as desired. Symbol : Night-time operation Symbol : Daytime/Night-time operation Orientation lighting This rotary controller serves to determine the working time of the orientation lighting (fixed to 20 %). “ON” for permanent orientation lighting. “OFF” for deactiviation of orientation lighting. Pulse spacing PD-Slave 2 or 9 seconds can be set for the pause between 2 pulses sent to the master. The setting can be made with activated ( ) or deactivated ( ) LED indicator. For devices with a separate slave input, 2 sec. can be set. 9s 2s LED ON LED OFF 25 22 18 16 10 3 1 TEST 6 30 R1 120 6050 40 30 15 10 A 16 10 5 2 1 30 15 TEST 2000 1200 600 200 40 5 60 5 10 30 50 ON OFF 6. Settings carried out using remote control (optional) Remote control LUXOMAT® IR-PDim 1. Check Battery: open battery compartment by pressing the plastic springs together and removing the battery-holder. 2. IMPORTANT Please pay attention, that the setting is Potentio-meter 1 at “TEST” and Potentiometer 2 not at “SUN”. All values which have been programmed using the remote control will be deleted in the event of power failure in the position “TEST/SUN”. Please switch Potentiometer 2 over to “MOON” or any other value. Caution: Settings with remote control supersede the settings by courtesy of potentiometers. 1 1 2 2 25 22 18 16 10 3 1 TEST 6 30 R1 120 6050 40 30 15 10 A 16 10 5 2 1 30 15 TEST 2000 1200 600 200 40 5 25 22 18 16 10 3 1 TEST 6 30 R1 2000 1200 600 200 40 False ceiling mounting 1 2 3 ON OFF DIP 1. Mounting preparations Work on the 230 V mains supply may only be carried out by quali- fied professionals or by instructed persons under the direction and supervision of qualified skilled electrical personnel in accordance with electrical regulations. Disconnect supply before installing! The device is not suited for safe disconnection of the mains supply. When in Master/Slave mode of op- eration, the Master-appliance must always be installed at the location where there is least daylight. 2a. Installation of the LUXOMAT® PD4-DIM-C-SM The detector must be in stalled on a solid and level surface. The circular cover ring must be removed prior to assembly. To do this, twist the lens (C) an- ticlockwise through approximately 5° and lift off. Having connected up the wires in accordance with regulations, secure the detector with 2 screws. After installation replace the lens and lock (turn clockwise). Mains to be connected. ATTENTION: For maximum sensitivity the detec- tor-, lens- and corridor-axis must match. C open close opened closed 2b. Montage LUXOMAT® PD4-DIM-C-FC The detector has been designed and developed specifically for installation in sus- pended ceilings. A circular opening of diameter 68 mm must first of all be produced in the ceiling. Having connected up the cables in accordance with regulations, the detector is inserted into the opening as shown in the drawing opposite and fixed into position with the assistance of the spring clip. 68mm b 8. Settings by remote control Unlocking device - Activation of the programming mode Resetting when- open: Deletes all values set with the remote con- trol, light OFF. or Start of the dim process Luminance set point for constant light control 50 Lux to 1500 Lux 1 min to 30 min 1 min to 60 min max 50 Lux 1500 Lux ON OFF max 50 Lux 1500 Lux ON OFF or max 50 Lux 1500 Lux ON optional optional optional t < 5 sec. Light on / off when closed => (see page 2, point 12) Dimming in the closed state => (see page 2, point 11) Test operation in the closed condition to enable Disable the test mode: press reset Resetting when closed The lighting relay is switched off, i.e. opened and the follow-up times reset. Permanent protection against sabotage This function blocks the unit permanently (green LED is illuminated). This operating mode can only be activated during the period of 5 seconds after pressing the “lock“ button. This status will only permit actuating the function “Light on/Light off”. The procedure for leaving this mode is as follows: 1. Switch off the current 2. Apply current for 31 - 59 seconds 3. Switch of the current again 4. Apply current 5. Open detector Dim in the open state To set a target value, proceed as follows (example workplace):Place one lux meter flat on the desk. Set the light with the help of remote control IR-PDim by pressing the buttons „max“ or „min“ for starting the dim process. Wait until the desired light level is reached. Confi rmation by the preset value Light during the initialization The light is on by default in the initialization time. On / off with the „Light“ button during Initialization. The final condition is then active. Follow-up time orientation light ON / OFF when open Note: Also during the orientation phase of the light constant light control is active: With sufficient brightness is <20% dimmed and turned off the lights if necessary. max 50 Lux 1500 Lux ON OFF t < 5 s 9. Explanation of the remote control button functions max 50 Lux 1500 Lux ON OFF max 50 Lux 1500 Lux ON OFF Stop of the dim process and reading in the current light value as new luminance set point Preset/user mode => (see page 2, point11) Follow-up time light Orientation lighting and its follow-up time Orientation lighting ON/OFF 20 % of the nominal light Fully automatic/semi automatic mode => (see page 2, point10) Locking device – Exit programming mode Permanent protection against sabotage LED fl ashes The DIP settings are enabled again by • Adjusting the DIP switches when closed • Reset with test sun setting at the potentiometers • Reset when open Corridor function: After deactivation by an external push button, the detector switches off and returns to automatic mode after 5 sec. Function LEDs OFF: In the open state and in test mode, the LEDs are always ON. ! In the initialization period During initialization phase/self test cycle Lights can be set to on or off status during initialization(60 Seconds) by using INI OFF/ON mode. max 50 Lux 1500 Lux ON OFF Light measure- ment Light measurement

18. Technical data PD4-M-DIM-C

15. Wiring diagrams MAN 7260 – 050314–3 In case the sensing area of the LUXOMAT® PD4-M-DIM-C is too large or areas are being covered that should not be monitored, the range can be reduced or limited through use of the enclosed masking clips (e). 14. Exclude sources of interference 13. Range 10. Fully / Semi automatic mode (for IR-PDim functions see page 1) The system switches over when the “Light” push-button is open (see remote control functions, page 1). Each time a push-button is pressed, the current operating mode is indicated: Red lights for 3 sec. = Fully automatic mode Green lights for 3 sec. = Semi-automatic mode Fully automatic operation In this operating mode, the lighting switches automatically on and off for increased comfort, depending on presence and brightness. Semiautomatic operation In this operating condition, in order to gain increasedsav- ings, the lighting is energized only after being manually switched on. Switch-off takes place automatically. The semiautomatic mode basically behaves like the fully automatic. However, the difference is that switching-on must always be carried out manually! As many (closer-contact) buttons as desired can be wired in parallel on the “S” button input (ON/OFF Dimm). 19. LED-functional indicators, fault-finding The functional indicators in the case of the LUXOMAT® PD4-M-DIM-C (red and green LED‘s) Red LED indicating self-checking mode (over a period of 60 seconds following mains‘-supply lock-on) Flashing at intervals of 1 second EEPROM/memory empty Flashing rapidly EEPROM/memory contains information Red LED as an indicator of status Flashing irregularly Movements are detected within the area of coverage Flashing regularly Detector identifies bright, light off (dependent upon operating mode) Not illuminated Detector identifies dark, light on (dependent upon operating mode) Flashing extremely rapidly Too bright / Too dark / Undefined Red LED as an acknowledgement of receipt for commands from the remote control Illuminated for 2 seconds Signal validly received Illuminated for 0.5 seconds Not-accepted command, detector blocked Flashing extremely rapidly Not-accepted command, occurs, for example, when an attempt is made to input twilight-value are too bright or too dark Green LED as an acknowledgement of receipt for commands from the remote control Lights up for 3 seconds Semi automatic or user signal correctly received Green LED as an indicator of status (only for status “Permanent protection against sabotage”) Flashing irregularly Movement are detected within the area of coverage Flashing regularly Detector identifies bright, light off (dependent upon operating mode) Not illuminated Detector identifies dark, light on (dependent upon operating mode) lluminated for 2 seconds Signal validly received (dependent upon operating mode) White LED Lights permanently Semi-automatic active (shines) Illuminates 4 seconds, then 1 sec off Semi-automatic and active corridor Illuminates 1 seconds, then 4 sec off Only active corridor e WE RECOMMEND THAT BEFORE DIMMING OF THE CONNECTED LIGHTS A 100h BURN IN (T5 TUBES OR 80 HOURS FOR T8 TUBES) FUNCTION TAKES PLACE. THE LIFESPAN OF THE LAMPS CAN BE REDUCED IF THE BURN IN DOES NOT TAKE PLACE. ON OFF max 50 Lux 1500 Lux ON OFF 12. Manual Switching You can switch the lighting on and off manually by pressing the pushbutton for a short time. It will stay on or off as long as people are detected plus the confi gured follow up time. 40 m 20 m 8 m 24 m 3 m 5 m 20 m 3 m 5 m 5 m 20 m 20 m 20 m 5 m 5 m 2.50 m 1 2 1 Walking across Walking towards 2 17. Article / Part nr. / Accessory 16. Connections Typ SM FC FM PD4-M-DIM-C (Master) 92218 92217 – PD4-S-C (Slave) 92442 92444 92445 LUXOMAT® Remote control: IR-PDim (incl. wall bracket) 92200 IR-PD-DIM-Mini 92098 Accessory: BSK Ball basket guard 92199 Occupancy detectors – Covering IP23 92206 SM-Wall bracket 92441 PD4-M-DIM-C-FC PD4-M-DIM-C-SM socket L N R Slave L' L S N N – + R T1 N L + – E1 1-10 V EB Sensor and power supply in one case Power supply: 230V~ ±10 % Power consumption: < 1W Ambient temperature: -25°C to +50°C Degree of protection/class: SM IP54, FC and FM IP20 / II / Settings: locally and by remote control Light values - IR-PDim: 50 - 1500Lux Extension of the detection area: with Slaves Area of coverage: narrow detection area, ideal for corridors Range of coverage Ø H 2.50 m / T = 18°C: tangential 40 m / radial 20 m Height for mounting: 2 - 3 m Light measurement: Mixed light, daylight + artificial light Lux values - Potentiometer: 10 - 2000 Lux • Channel 1 for light-connection Type of contact: NOC/with pretravel tungsten contact Contact load: 2300 W cos ϕ=1 / 1150VA cosϕ=0.5, µ-Contact Time-settings: 1 - 30min. / Test DIM-Output: 1 x (1-10V) Max. no. of series-connected electronic ballasts: max. 50 electronic ballasts by one single supply with max. 100 m cable run and a conductur cross-section of 0.75mm² Dimensions H x Ø [mm] SM FC FM PD4-M-DIM-C 65 x 98 103 x 97 84 x 97 Visible portion when built into ceiling: 30 x 97mm Technical data PD4-Slave-C Power supply: 230V~ ±10 % Impulse output: Optocoupler max. 2 W Impulse duration: 2sec. or 9 sec. Dimensions: see above Declaration of Conformity: The product complies with the low voltage recommendation 2006/95/EC and the EMV recommen- dation 2004/108/EC. L N R Slave L' L S N – + R T1 N L + – E1 1-10 V EB 11. Manual Dimming – Preset /User (for IR-PDim functions see page 1) Manual dimming – Start the dim process by pressing the push button „min/max“. Stop by pressing the push button „eye“. PRESET – the luminance set point is set during start-up operation by the installer and remains unchanged. The luminance set- point confi gured through manual dimming is only applied for the time being. Caution: The constant light regulation is now deactivated! The currently set artifi cial light is retained independent of the ambient/daylight brightness! After switching off and then back on, the originally set luminance set-point is reset = constant light regulation is activated. USER The luminance set-point is changed upon each manual dim- ming and re-adjusted by the user (Conformation through relay clicking!) The constant light regulation remains activated! The system switches over when the “Doublelock” push-button is open (see remote control functions, page 1). Each time a push-button is pressed, the current operating mode is indicated: Red lights for 3 sec. = Preset Green lights for 3 sec. = User max 50 Lux 1500 Lux ON OFF Standard mode with master DIM occupancy detectors            L N E1 110 V EB N L +  R S L L΄΄΄΄ N  + N L R T1 C1 optional T1 = NO button for semi-automatic mode Slave for enlargement of detection area

Other Security Sensors Manuals