BELL LABS INNOVATIONS Lucent Stinger Series Manual
Read Online
Read the BELL LABS INNOVATIONS Lucent Stinger Series Manual online using the built-in PDF viewer.
Text of the manual
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
For software version 9.1-142
April 2001
Copyright© 2000, 2001 Lucent Technologies Inc. All rights reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any
entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts, or licensing, without the express
written consent of Lucent Technologies. For permission to reproduce or distribute, please email your request to [email protected].
Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing, but information is subject to change.
Safety, Compliance, and Warranty Information
Before handling any Lucent Access Networks hardware product, read the Edge Access Safety and Compliance Guide included in your product package. See
that guide also to determine how products comply with the electromagnetic interference (EMI) and network compatibility requirements of your country. See
the warranty card included in your product package for the limited warranty that Lucent Technologies provides for its products.
Security Statement
In rare instances, unauthorized individuals make connections to the telecommunications network through the use of access features.
Trademarks
4ESS, 5ESS, 7R/E, AnyMedia, APX 8000, AQueView, B-STDX 8000, B-STDX 9000, CaseView, CBX 500, CellPipe, ChoiceNet, ClearReach, ComOS,
cvMAX, DACS, DACSmate, Datakit, DDM 2000FiberReach, DSLMAX, DSLPipe, DSL Terminator, DSLPipe, DSLTNT, elemedia, elemedia Enhanced,
EMMI, GRF, GX 550, HyperPATH, Inferno, InfernoDesign, IntragyAccess, IntragyCentral, IP Navigator, IPWorX, LineReach, LinkReach, MAX, MAXENT,
MAX TNT, Metropolis, MetroView, Multiband, MultiLink Protocol Plus, MultiVoice, MultiVPN, Navis, NavisRadius, NetCare, NetLight, NetPartner,
NetworkCare, NX64000, OneVision, Open Systems Innovations, OpenTrunk, PacketStar, PathStar, Pinnacle, Pipeline, PortMaster, QVPN, QVPN Builder,
SecureConnect, Series56, SmoothConnect, SpringTide, Stinger, SuperLine, SuperPipe, SYSTIMAX, True Access, WaveLAN, WaveMANAGER,
WaveMODEM, and WebXtend are trademarks of Lucent Technologies Inc. eSight is a service mark of Lucent Technologies Inc. Other trademarks, service
marks, and trade names mentioned in this publication belong to their respective owners.
Copyrights for Third-Party Software Included in Lucent Access Networks Software Products
C++ Standard Template Library software copyright© 1994 Hewlett-Packard Company and copyright© 1997 Silicon Graphics. Permission to use, copy,
modify, distribute, and sell this software and its documentation for any purpose is hereby granted without fee, provided that the above copyright notice appear
in all copies and that both that copyright notice and this permission notice appear in supporting documentation. Neither Hewlett-Packard nor Silicon Graphics
makes any representations about the suitability of this software for any purpose. It is provided “as is” without express or implied warranty.
Berkeley Software Distribution (BSD) UNIX software copyright© 1982, 1986, 1988, 1993 The Regents of California. All rights reserved. Redistribution and
use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code
must retain the above copyright notice, this list of conditions, and the following disclaimer. 2. Redistributions in binary form must reproduce the above copy-
right notice, this list of conditions, and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. All advertising
materials mentioning features or use of this software must display the following acknowledgement: This product includes software developed by the Univer-
sity of California, Berkeley, and its contributors. 4. Neither the name of the University nor the names of its contributors may be used to endorse or promote
products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
OR SERVICES; LOSS OF USE, DATA OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Ordering Information
You can order the most up-to-date product information and computer-based training online at http://www.lucent.com/ins/bookstore.
Feedback
Lucent Technologies appreciates your comments, either positive or negative, about this manual. Please send them to [email protected].
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
iii
Customer Service
To obtain product and service information, software upgrades, and technical assistance, visit
the eSight™ Service Center at http://www.esight.com. The center is open 24 hours a
day, seven days a week.
Finding information and software
The eSight Service Center at http://www.esight.com provides technical information,
product information, and descriptions of available services. Log in and select a service. The
eSight Service Center also provides software upgrades, release notes, and addenda. Or you can
visit the FTP site at ftp://ftp.ascend.com for this information.
Obtaining technical assistance
The eSight™ Service Center at http://www.esight.com provides access to technical
support. You can obtain technical assistance through email or the Internet, or by telephone.
If you need to contact Lucent Technologies for assistance, make sure that you have the
following information available:
•
Active contract number, product name, model, and serial number
•
Software version
•
Software and hardware options
•
If supplied by your carrier, service profile identifiers (SPIDs) associated with your line
•
Your local telephone company’s switch type and operating mode, such as AT&T 5ESS
Custom or Northern Telecom National ISDN-1
•
Whether you are routing or bridging with your Lucent product
•
Type of computer you are using
•
Description of the problem
Obtaining assistance through email or the Internet
If your services agreement allows, you can communicate directly with a technical engineer
through Email Technical Support or eSight Live chat. Select one of these sites when you log in
to http://www.esight.com.
Calling the technical assistance center (TAC)
If you cannot find an answer through the tools and information on eSight or if you have a very
urgent need, contact TAC. Access the eSight Service Center at http://www.esight.com
and click Contact Us below the Lucent Technologies logo for a list of telephone numbers
inside and outside the United States.
You can alternatively call (800) 272-3634 for a menu of Lucent services, or call
(510) 769-6001 for an operator. If you do not have an active services agreement or contract,
you will be charged for time and materials.
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
v
Contents
Customer Service ..................................................................................................................... iii
About This Guide.............................................................................. xi
What is in this guide.................................................................................................................. xi
What you should know ............................................................................................................. xi
Documentation conventions...................................................................................................... xi
Documentation set................................................................................................................... xii
Chapter 1
Configuring the SHDSL/HDSL2 32-Port LIM................................. 1-1
Installing the SHDSL/HDSL2 LIM ...................................................................................... 1-2
Module specifications ............................................................................................................ 1-2
Status indicators ..................................................................................................................... 1-3
Interpreting SHDSL/HDSL2 32-port LIM status lights ................................................. 1-3
Embedded Operations Channel (EOC) protocol compliance......................................... 1-4
MIBs ............................................................................................................................... 1-4
Specifying HDSL2 or SHDSL mode..................................................................................... 1-4
Configuring SHDSL/HDSL2 interfaces ................................................................................ 1-5
Configuring port settings for SHDSL and HDSL2......................................................... 1-5
Sample HDSL2 mode configuration............................................................................. 1-10
Sample SHDSL mode configuration ............................................................................ 1-11
Displaying SHDSL/HDSL2 port status ........................................................................ 1-11
Configuring call control....................................................................................................... 1-12
Checking the status of an SHDSL/HDSL2 interface........................................................... 1-14
Checking the status of the physical interface................................................................ 1-14
Obtaining statistics about operations ............................................................................ 1-15
Internal and external diagnostic tests and BERT................................................................. 1-16
Configuring an internal diagnostic test (IDT)............................................................... 1-18
Configuring a bit-error rate test (BERT) ...................................................................... 1-19
Configuring an external diagnostic test (EDT)............................................................. 1-19
Chapter 2
Configuring LIM and LIM Port Redundancy................................. 2-1
Overview of LIM and LIM port redundancy......................................................................... 2-1
Configuring LIM redundancy ................................................................................................ 2-1
Overview of the LIM-Sparing-Config profile ................................................................ 2-2
Manual LIM redundancy ................................................................................................ 2-4
Automatic LIM redundancy............................................................................................ 2-5
LIM redundancy with IRMs and LPM-Rs...................................................................... 2-7
Checking LIM redundancy status................................................................................... 2-8
Checking status with the Rearslot command.................................................................. 2-9
Configuring LIM port redundancy....................................................................................... 2-10
Enabling LIM port redundancy..................................................................................... 2-11
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Contents
Manual LIM port redundancy....................................................................................... 2-12
Automatic LIM port redundancy .................................................................................. 2-12
Checking the status of extended LIM port redundancy................................................ 2-13
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
vii
Figures
Figure 1-1
SHDSL/HDSL2 32-port LIM....................................................................... 1-3
Figure 1-2
Data passes through a modem’s digital circuitry (digital loopback).......... 1-20
Figure 1-3
Data passes through a modem’s digital circuitry and analog circuitry
(analog loopback). ...................................................................................... 1-20
Figure 2-1
LIM redundancy on a Stinger FS.................................................................. 2-2
Figure 2-2
LIM port redundancy on a Stinger FS........................................................ 2-11
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
ix
Tables
Table 1-2
SHDSL/HDSL2 32-port LIM status lights ................................................... 1-4
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
xi
About This Guide
What is in this guide
This guide describes how to configure and monitor the Stinger™ SHDSL/HDSL2 line
interface module (LIM) and includes configuration examples and module specifications. This
guide also describes how to configure LIM redundancy.
!
Warning: Before installing your Stinger unit, be sure to read the safety instructions in the
Edge Access Safety and Compliance Guide. For information specific to your unit, see the
“Safety-Related Physical, Environmental, and Electrical Information” appendix in the Getting
Started Guide for your Stinger unit.
What you should know
To make use of the procedures and sample configurations in this guide, you should have a
general knowledge of Stinger products and a working knowledge of the command-line
interface. You should understand the fundamental concepts of digital subscriber line (DSL)
technology and be familiar with the relationship between DSL interfaces and associated
configuration profiles.
Documentation conventions
Following are the special characters and typographical conventions used in this manual:
Convention
Meaning
Monospace text
Represents text that appears on your computer’s screen, or that could
appear on your computer’s screen.
Boldface
monospace text
Represents characters that you enter exactly as shown (unless the
characters are also in italics—see Italics, below). If you could
enter the characters but are not specifically instructed to, they do not
appear in boldface.
Italics
Represent variable information. Do not enter the words themselves in
the command. Enter the information they represent. In ordinary text,
italics are used for titles of publications, for some terms that would
otherwise be in quotation marks, and to show emphasis.
[ ]
Square brackets indicate an optional argument you might add to a
command. To include such an argument, type only the information
inside the brackets. Do not type the brackets unless they appear in
boldface.
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
About This Guide
Documentation set
Documentation set
The Stinger documentation set consists of the following manuals:
•
Read me first:
–
Edge Access Safety and Compliance Guide. Contains important safety instructions
and country-specific information that you must read before installing a Stinger unit.
–
TAOS Command-Line Interface Guide. Introduces the TAOS command-line
environment and shows you how to use the command-line interface effectively. This
guide describes keyboard shortcuts and introduces commands, security levels, profile
structure, and parameter types.
•
Installation and basic configuration:
Individual Stinger module guides describe the features of and provide instructions for
configuring and verifying the status of Stinger modules.
–
Getting Started Guide for your unit. Shows how to install your Stinger chassis and
hardware. This guide also shows you how to use the command-line interface to
configure and verify IP access and basic access security on the unit, and how to
configure Stinger control module redundancy.
–
For each Stinger line interface module (LIM), trunk module, or other type of module,
an individual guide describes the module's features and provides instructions for
configuring the module and verifying its status.
|
Separates command choices that are mutually exclusive.
>
Points to the next level in the path to a parameter or menu item. The
item that follows the angle bracket is one of the options that appear
when you select the item that precedes the angle bracket.
Key1-Key2
Represents a combination keystroke. To enter a combination
keystroke, press the first key and hold it down while you press one or
more other keys. Release all the keys at the same time. (For example,
Ctrl-H means hold down the Control key and press the H key.)
Press Enter
Means press the Enter, or Return, key or its equivalent on your
computer.
Note:
Introduces important additional information.
!
Caution:
Warns that a failure to follow the recommended procedure could result
in loss of data or damage to equipment.
!
Warning:
Warns that a failure to take appropriate safety precautions could result
in physical injury.
Warning:
Warns of danger of electric shock.
Convention
Meaning
About This Guide
Documentation set
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
xiii
•
Configuration:
–
Stinger ATM Configuration Guide. Describes how to use the command-line interface
to configure Asynchronous Transfer Mode (ATM) operations on a Stinger unit. The
guide explains how to configure permanent virtual circuits (PVCs), and shows how to
use standard ATM features such as quality of service (QoS), connection admission
control (CAC), and subtending.
–
Stinger Private Network-to-Network Interface (PNNI) Supplement. Provides
quickstart instructions for configuring PNNI and soft PVCs (SPVCs), and describes
the related profiles and commands in the Stinger command-line interface.
–
Stinger SNMP Management of the ATM Stack Supplement. Describes SNMP
management of ATM ports, interfaces, and connections on a Stinger unit to provide
guidelines for configuring and managing ATM circuits through any SNMP
management utility.
–
TAOS RADIUS Guide and Reference. Describes how to set up a TAOS unit to use the
Remote Authentication Dial-In User Service (RADIUS) server and contains a
complete reference to RADIUS attributes.
•
Administration and troubleshooting:
–
Stinger Administration Guide. Describes how to administer the Stinger unit and
manage its operations. Each chapter focuses on a particular aspect of Stinger
administration and operations. The chapters describe tools for system management,
network management, and Simple Network Management Protocol (SNMP)
management.
•
Reference:
–
Stinger Reference. An alphabetic reference to Stinger profiles, parameters, and
commands.
–
TAOS Glossary. Defines terms used in documentation for Stinger units.
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
1-1
1
Configuring the SHDSL/HDSL2 32-Port
LIM
The Stinger SHDSL/HDSL2 line interface module (LIM) supports both single-pair high-speed
digital subscriber line (SHDSL) mode and high-speed digital subscriber line 2 (HDSL2) mode.
When the LIM is installed in a Stinger slot, the Stinger chassis connects the LIM to a line
protection module (LPM), which provides the physical connections for incoming lines. The
SHDSL/HDSL2 LIM provides 32 SHDSL or HDSL2 interfaces per LIM.
You select the mode of operation for the module by the interface-type parameter. (For
details, see “Specifying HDSL2 or SHDSL mode” on page 1-4.) In SHDSL mode, a Stinger
unit supports symmetric data transfer rates from 72Kbps to 2312Kbps. In HDSL2 mode, the
Stinger unit supports symmetric data transfer at 1.544Mbps over a single twisted pair.
HDSL2 and SHDSL technologies are spectrally compatible with other loop technologies such
as ISDN, T1, and HDSL.
Note: The SHDSL/HDSL2 32-port LIM (product code STGR-LIM-H2-32) for Stinger FS
and Stinger LS units was previously known as the HDSL2 32-port LIM. The product code
number and the hardware remain the same, but the SHDSL designation has been added to the
module name to note the new SHDSL software capability.
For information about limitations and known issues about this LIM, see the latest Stinger
TAOS release notes.
Note: Unless noted otherwise, the configuration information and parameters described in this
guide apply to both SHDSL and HDSL2 mode of operation.
Installing the SHDSL/HDSL2 LIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Module specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Status indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Specifying HDSL2 or SHDSL mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Configuring SHDSL/HDSL2 interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Configuring call control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Checking the status of an SHDSL/HDSL2 interface. . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
Internal and external diagnostic tests and BERT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring the SHDSL/HDSL2 32-Port LIM
Installing the SHDSL/HDSL2 LIM
Installing the SHDSL/HDSL2 LIM
Install the SHDSL/HDSL2 32-port module in the same manner as for any other LIM module.
For detail, see the Stinger Getting Started Guide for your unit. After installation, follow the
instructions in this document to configure the module.
Module specifications
Table 1-1 shows the specifications for the SHDSL/HDSL2 32-port LIM.
Table 1-1. Specifications for the SHDSL/HDSL2 32-port LIM
Category
Specification
Physical dimensions
Height: 15 inches (38.1 cm).
Width: 1.06 inches (2.69 cm).
Depth: 9 inches (22.8 cm).
Weight
3.8 lbs (1.7Kg)
Maximum power
requirements
HDSL2:
70W
SHDSL:
80W
Temperature
FS/LS version: 32°F to 131°F (0°C to 55°C)
RT version: -40°F to 149°F (-40°C to 65°C
Relative Humidity
RT version: 10% through 90% (noncondensing)
Operating Altitude
RT version: Up to 13,123 feet (4,000 m)
Interface standards
HDSL2:
ANSI T1 418 Issue 1
T1E1.4/99-006R6
SHDSL:
ITU G.991.2 (G.shdsl)
Annex A (North America)
Annex B (Europe)
ETSI TS 101 524 (Similar to ITU G.991.2
Annex B implementation)
ITU G.994.1 (G.hs)
ITU G.997.1 (physical layer management)
Range
HDSL2:
Maximum 12,000 feet with 24 AWG wire
at 1.544Mbps
Maximum 9,000 ft with 26 AWG wire at
1.544Mbps
SHDSL:
Maximum 24,000 feet with 24 AWG wire
at 192Kbps
Maximum 12,000 ft with 24 AWG wire at
2.312Mbps
Configuring the SHDSL/HDSL2 32-Port LIM
Status indicators
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
1-3
Status indicators
Several status lights on the front panel of the SHDSL/HDSL2 32-port LIM indicate the status
of the module and its ports. Figure 1-1 shows the front panel and status lights of the
SHDSL/HDSL2 32-port LIM.
Figure 1-1. SHDSL/HDSL2 32-port LIM
Interpreting SHDSL/HDSL2 32-port LIM status lights
All status lights illuminate briefly upon startup or restart, then remain dark until the module
passes its power-on self test (POST). When the module passes its POST and becomes
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring the SHDSL/HDSL2 32-Port LIM
Specifying HDSL2 or SHDSL mode
operational, the ACTIVE light illuminates. It is the only light that is on during normal
operation. Table 1-2 explains the SHDSL/HDSL2 32-port LIM status lights.
Embedded Operations Channel (EOC) protocol compliance
Embedded Operations Channel (EOC) protocol compliance is defined within the
T1E1.4/99-006R6 HDSL2 Draft Standard specification. The EOC protocol provides
identification and statistical information about the HDSL2 interface and its remote repeaters
and associated customer premesis equipment (CPE) and central office equipment nodes.
To display basic statistics, view the hdsl2-stat profile. You can display additional
information by using the hdsl2dumpeoc debug command, which is run directly from the
SHDSL/HDSL2 LIM.
MIBs
An HDSL2 Management Information Base (MIB) provides status and statistical information.
Specifying HDSL2 or SHDSL mode
Set the interface-type parameter to specify whether the SHDSL/HDSL2 32-port LIM
operates in HDSL2 or SHDSL mode at the slot level.
Note: HDSL2 and SHDSL technologies are not interoperable between the customer premises
equipment (CPE) and the central office equipment (COE). The setting of the
interface-type parameter on the COE must match that of the CPE. The following
example configures the COE for SHDSL mode:
admin> read slot-static-config { 1 3 0}
SLOT-STATIC-CONFIG/{ shelf-1 slot-3 0 } read
Table 1-2. SHDSL/HDSL2 32-port LIM status lights
Light
Color
Indication
STBY
Orange
The module is a designated spare. The control module
switches traffic to the module if one of the other
modules fails.
ACTIVE
Green
The module or port is fully operational and no errors
have been detected.
FAULT
Orange
The module failed to pass its POST.
BYPASS
Orange
The module is in bypass mode. (The module
redundancy feature is activated.)
PORT
Green
The local and remote ends of the physical line have
achieved frame synchronization, and the local end of
the ATM link has achieved cell delineation.
If the light is not illuminated, the port is inactive.
Configuring the SHDSL/HDSL2 32-Port LIM
Configuring SHDSL/HDSL2 interfaces
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
1-5
admin >list
[in SLOT-STATIC-CONFIG/{ shelf-1 slot-3 0 }]
admin> set interface-type = g-shdsl
admin> write
Note: If you are upgrading to TAOS 9.1-142 from an earlier software version, the
SHDSL/HDSL2 32-port LIM is set to operate in SHDSL mode by default.
Configuring SHDSL/HDSL2 interfaces
The SHDSL/HDSL2 32-port LIM supplies up to 32 interfaces per LIM. A Stinger unit creates
an hdsl2 profile for each SHDSL/HDSL2 interface in the system.
For example, for an SHDSL/HDSL2 32-port LIM installed in slot 1, the system creates profiles
such as the following:
admin> dir hdsl2
18 06/20/1999 23:18:51 { shelf-1 slot-1 1 } 1:1:1
18 06/20/1999 23:18:51 { shelf-1 slot-1 2 } 1:1:2
18 06/20/1999 23:18:51 { shelf-1 slot-1 3 } 1:1:3
18 06/20/1999 23:18:51 { shelf-1 slot-1 4 } 1:1:4
18 06/20/1999 23:18:51 { shelf-1 slot-1 5 } 1:1:5
18 06/20/1999 23:18:51 { shelf-1 slot-1 6 } 1:1:6
18 06/20/1999 23:18:51 { shelf-1 slot-1 7 } 1:1:7
18 06/20/1999 23:18:51 { shelf-1 slot-1 8 } 1:1:8
...
Configuring port settings for SHDSL and HDSL2
SHDSL/HDSL2 ports are configured in each port’s hdsl2 profile. For example, the hdsl2
profile for port 1 of a LIM in slot 2 might be configured as follows:
admin> read hdsl2 { 1 2 1 }
HDSL2/{ shelf-1 slot-2 1 } read
admin> list
[in HDSL2/{ shelf-1 slot-2 1 }]
name = 1:2:1
Parameter
Specifies
interface-type
HDSL2 or SHDSL mode. Specify one of the following values:
•
g-shdsl ( default)—The LIM operates in SHDSL mode.
Note: You must also set the g-shdsl, the rate-mode,
min-rate, and max-rate parameters, which do not apply if
you set one of the other modes.
•
hdsl2—The LIM operates in HDSL2 mode.
•
default—The slot contains a module other than the
SHDSL/HDSL2 32-port LIM.
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring the SHDSL/HDSL2 32-Port LIM
Configuring SHDSL/HDSL2 interfaces
physical-address* = { shelf-1 slot-2 1 }
enabled = no
sparing-mode = inactive
line-config = { 0 51 15 static { any-shelf any-slot 0 } coe }
admin> list line
[in HDSL2/{ shelf-1 slot-2 1 }:line-config]
trunk-group = 0
nailed-group = 51
vp-switching-vpi = 15
activation = static
call-route-info = { any-shelf any-slot 0 }
unit-type = coe
ntr-enable = no
clock-source = not-eligible
clock-priority = middle-priority
loop-back = non
margin = 6db
rate-mode = fixed
min-rate = 72000
max-rate = 2312000
gshdsl-standard-network-type = north-american-annex-a
gshdsl-psd-type = symmetric
Parameter
Specifies
name
Name of the interface. The default value is the interface address in
shelf:slot:item format (for example, 1:2:1), but you can assign
a text string of up to 16 characters.
physical-address
Physical address of the interface in the Stinger unit.
enabled
Enable/disable the interface. Specify one of the following values:
•
no (the default)—Line is disabled until you active it in the
hdsl2 profile.
•
yes—Line is enabled.
trunk-group
Not currently used. Use the default value (zero).
nailed-group
Nailed-group number for the SHDSL or HDSL2 physical
interface. A Connection or RADIUS profile specifies this number
to make use of the interface.
Each interface is assigned a unique default number, so you need
not modify this parameter. If you assign a new value, it must be a
number from 1 to 1024 that is unique within the system.
VP-switching-VPI
The virtual path identifier (VPI) to use for virtual path (VP)
switching on the LIM port. The default is 15. All other VPIs are
used for virtual circuit (VC) switching.
activation
Not currently used. Leave the default value (static).
call-route-info
Not currently used. Leave the default value (the zero address).
Configuring the SHDSL/HDSL2 32-Port LIM
Configuring SHDSL/HDSL2 interfaces
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
1-7
unit-type
Type of unit. Remote equipment must have opposite setting.
Specify one of the following values:
•
coe (the default)—The unit is central office equipment
(COE).
•
cpe—The unit is customer premises equipment (CPE).
NTR-enabled
Enable/disable network time reference (NTR) capability. Specify
one of the following values:
•
no (the default)—NTR capability is disabled.
•
yes—NTR capability is enabled.
If the unit-type parameter is set to coe, the system clock is
taken as the input and the CPE, if equipped to do so, can recover
the clock.
If the unit-type parameter is set to cpe, the port outputs the
recovered clock as the system clock if the clock-source
parameter is set to eligible and the clock-priority
parameter is set to allow the clock to be selected.
clock-source
Eligibility of the 8kHz clock from the SHDSL/HDSL2 line to be
used as the 8kHz system clock. Specify one of the following
values:
•
eligible—The line can be used as the master clock source.
(The unit-type parameter must be set to cpe).
•
not-eligible—The line can not be used as the master
clock source.
clock-priority
Clock priority assigned to the SHDSL/HDSL2 line. Used to select
a particular HDSL2 line as the 8kHz system clock source. Specify
one of the following values:
•
high-priority—A line with this priority is selected over
lines with lower priorities. If more than one line has the
highest priority, the first one to become available is the
source.
•
middle-priority—Second-highest clock priority.
•
low-priority—Last clock priority.
loop-back
Whether the line passes normal data or is in loopback mode.
Specify one of the following values:
•
none (default)—The line is not being used for loopback
testing.
•
analog—The line is enabled for analog loopback testing.
(You might need to terminate the DSL line with a 150-ohm
resistor).
•
digital—The line is enabled for digital loopback testing.
Parameter
Specifies
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring the SHDSL/HDSL2 32-Port LIM
Configuring SHDSL/HDSL2 interfaces
margin
Noise margin value (in decibels). Specifying a value that is less
than 6 decibels causes modems to train at higher rates, but on
noisy loops, also causes them to become unstable and retrain. If
this parameter is set to a value that is less than 6 decibels, the
modems train at lower rates, but are more stable and are less likely
to retrain on noisy loops. This parameter applies to only if the
interface-type parameter is set to g-shdsl. Specify one of
the following values:
•
0db
•
1db
•
2db
•
3db
•
4db
•
5db
•
6db (the default)
•
7db
•
8db
•
9db
•
10db
•
11db
•
12db
•
13db
•
14db
•
15db
rate-mode
Whether the line rate is fixed or adaptive (also called automatic).
This parameter applies only if the interface-type parameter
is set to g-shdsl. Specify one of the following values:
•
fixed—A modem attempts to train only at the rate specified
by the max-rate parameter.
•
auto (default)—A modem attempts to train at a rate within
the range specified by the min-rate and max-rate
parameters.
Parameter
Specifies
Configuring the SHDSL/HDSL2 32-Port LIM
Configuring SHDSL/HDSL2 interfaces
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
1-9
min-rate
Minimum rate in kilobits per second at which a modem trains
when the rate-mode parameter is set to auto. This parameter
applies only if the interface-type parameter is set to
g-shdsl. Specify one of the following values:
•
72000 (the default)
•
136000
•
200000
•
264000
•
328000
•
392000
•
520000
•
776000
•
1032000
•
1160000
•
1288000
•
1544000
•
2056000
•
2312000
max-rate
Maximum rate at which the modem trains when rate-mode is
set to auto. When rate-mode is set to fixed, the modem
attempts to train only to the rate specified by this parameter. You
need only configure the central office equipment (COE) for the
maximum rate value. The modem uses G.h handshake protocol to
communicate the maximum rate value to the customer premises
equipment (CPE). This parameter applies only if the
interface-type parameter is set to g-shdsl.
•
72000
•
136000
•
200000
•
264000
•
328000
•
392000
•
520000
•
776000
•
1032000
•
1160000
•
1288000
•
1544000
•
2056000
•
2312000 (the default)
Parameter
Specifies
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring the SHDSL/HDSL2 32-Port LIM
Configuring SHDSL/HDSL2 interfaces
Sample HDSL2 mode configuration
To configure the SHDSL/HDSL2 32-port line interface module for HDSL2 operation, you
must first set the interface-type parameter to hdsl2 as described in “Specifying
HDSL2 or SHDSL mode” on page 1-4. Following is an example of a profile for one of the
lines of an SHDSL/HDSL2 32-port module that is operating in HDSL2 mode:
admin> read hdsl2 { 1 2 1 }
HDSL2/{ shelf-1 slot-2 1 } read
admin> list
[in HDSL2/{ shelf-1 slot-2 1 }]
name = 1:2:1
physical-address* = { shelf-1 slot-2 1 }
enabled = no
sparing-mode = inactive
line-config = { 0 51 15 static { any-shelf any-slot 0 } coe }
admin> list line
[in HDSL2/{ shelf-1 slot-2 1 }:line-config]
nailed-group = 51
vp-switching-vpi = 15
gshdsl-standard-
network-type
The G.991.2 standard network type for the network that is
connected to the SHDSL port. This setting specifies the modem
output characteristics for either a North American or European
network. This parameter applies only if the interface-type
parameter is set to g-shdsl. Specify one of the following
values:
•
north-american-annex-a—North American Annex A
network
•
european-annex-b—European Annex B network
gshdsl-psd-type
That the modem outputs a symmetric power spectral density
(PSD), based on the G.shdsl standard G.911.2. Specify one of the
following values:
•
symmetric—The modem outputs a symmetric power
spectral density for all rates.
•
asymmetric-776k-psd—The modem outputs an
asymmetric power spectral density at 776Kbps only. This
setting applies only if the rate-mode parameter is set to
fixed, the max-rate parameter is set to is 776000, and
the network-type parameter is set to
north-american-annex-a.
•
asymmetric-1544k-psd—The modem outputs an
asymmetric power spectral density at 1544Kbps only. This
setting applies only if the rate-mode parameter is set to
fixed, the max-rate parameter is set to is 1544000, and
the network-type parameter is set to
north-american-annex-a.
Parameter
Specifies
Configuring the SHDSL/HDSL2 32-Port LIM
Configuring SHDSL/HDSL2 interfaces
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
1-11
unit-type = coe
ntr-enable = no
clock-source = not-eligible
clock-priority = middle-priority
loop-back = n
Sample SHDSL mode configuration
To configure the SHDSL/HDSL2 32-port line interface module for SHDSL operation, you
must first set the interface-type parameter to g-shdsl as described in “Specifying
HDSL2 or SHDSL mode” on page 1-4. Following is an example of an hdsl2 profile
configured for an SHDSL/HDSL2 line that operates in SHDSL mode:
admin> read hdsl2 { 1 3 1}
HDSL2/{ shelf-1 slot-3 1 } read
admin >list
[in HDSL2/{ shelf-1 slot-3 1 }]
name = 1:3:1
physical-address* = { shelf-1 slot-3 1 }
enabled = yes
sparing-mode = inactive
line-config = { 0 101 15 static { any-shelf any-slot 0 } coe no
not-eligible mi+
admin> list line
[in HDSL2/{ shelf-1 slot-3 1 }:line-config]
nailed-group = 101
vp-switching-vpi = 15
unit-type = coe
ntr-enabled = no
clock-source = not-eligible
clock-priority = middle-priority
loop-back = none
margin = 6db
rate-mode = auto
min-rate = 72000
max-rate = 2312000
gshdsl-standard-network-type = north-american-annex-a
gshdsl-psd-type = symmetric
Displaying SHDSL/HDSL2 port status
To display the port status and nailed group for each SHDSL/HDSL2 port, use the
hdsl2Lines command. For a description of the command’s syntax, enter the command
name, as in the following example:
admin> hdsl2Lines
usage: Hdsl2Lines -[ a | d | f | u | t ]
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring the SHDSL/HDSL2 32-Port LIM
Configuring call control
-a show (a)ll HDSL2 lines
-d show (d)isabled lines
-f show all (f)ree lines
-u show in-(u)se lines
-t toggle debug flag
The following example (which is truncated) shows status of the first 16 ports on an
SHDSL/HDSL2 LIM in slot 4:
admin> hdsl2 -a
All HDSL2 lines: (dvOp dvUpSt dvRq sAdm nailg)
Line { 1 4 1 } (Down Idle DOWN DOWN 00151)
Line { 1 4 2 } (Down Idle DOWN DOWN 00152)
Line { 1 4 3 } (Up Idle UP UP 00153)
Line { 1 4 4 } (Down Idle DOWN DOWN 00154)
Line { 1 4 5 } (Down Idle DOWN DOWN 00155)
Line { 1 4 6 } (Down Idle DOWN DOWN 00156)
Line { 1 4 7 } (Up Idle UP UP 00157)
Line { 1 4 8 } (Down Idle DOWN DOWN 00158)
Line { 1 4 9 } (Up Idle UP UP 00159)
Line { 1 4 10 } (Up Idle UP UP 00160)
Line { 1 4 11 } (Down Idle DOWN DOWN 00161)
Line { 1 4 12 } (Down Idle DOWN DOWN 00162)
Line { 1 4 13 } (Up Idle UP UP 00163)
Line { 1 4 14 } (Down Idle DOWN DOWN 00164)
Line { 1 4 15 } (Down Idle DOWN DOWN 00165)
Line { 1 4 16 } (Down Idle DOWN DOWN 00166)
Configuring call control
Using the call-control procedures, you can configure a Stinger unit to allow connections to be
established even when the line state is not fully up. You can configure the unit to use these
procedures systemwide or on a per-port basis on the SHDSL/HDSL2 32-port LIM.
The call-control mechanism enables the Stinger unit to establish and maintain soft PVCs
(SPVCs) across port state changes. This feature allows xDSL subscribers to establish
connections on LIM interfaces in the operating states that exist before the modems are fully
trained, as well as in the standard port-up state. SPVC connections are accepted when the
modem has not fully trained to the port-up state. If a LIM interface with an active SPVC
connection changes from a port-up state to the state before it was fully trained, the SPVC
remains connected. Connections are broken only if the physical slot or line stops operating or
is disabled by an administrator.
By default, a Stinger unit monitors the physical line states of its interfaces and allows
connections to be established only when the line state is fully up.
Following are examples of the call-control parameters, shown with their default settings:
Configuring the SHDSL/HDSL2 32-Port LIM
Configuring call control
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
1-13
[in SYSTEM]
ignore-lineup = no
[in SDSL/{ any-shelf any-slot 0 }]
ignore-lineup = system-defined
[in DS3-ATM/{ any-shelf any-slot 0 }]
ignore-lineup = system-defined
The commands in the following example configure the unit to use the new call-control
procedures systemwide:
admin> read system
SYSTEM read
admin> set ignore-lineup = yes
admin> write
SYSTEM written
When call control is enabled systemwide, you can disable it on specific interfaces by
modifying the line profile. For example, the following commands disable call-control
procedures on port one of the SDSL 48-port LIM in slot 12:
admin> read sdsl { 1 12 1 }
SDSL/{ shelf-1 slot-12 1 } read
admin> set ignore-lineup = no
Parameter
Specifies
SYSTEM >
ignore-lineup
Enable/disable the Stinger ability to ignore line status when
determining whether calls are established or not. Specify one of the
following values:
•
no (the default)—The Stinger call-control mechanism allows
calls to be established if the line state is up and disallows calls if
the line state is down.
•
yes—The Stinger call-control mechanism ignores the line state
and allows calls to be established on a port as long as the
specified slot is operational and the specified port is enabled.
line profile >
ignore-lineup
Whether the line status of a slot has an effect on the Stinger
call-control mechanism on the specified port. Specify one of the
following values:
•
system-defined (the default)—The Stinger unit inherits the
Ignore-Lineup value from the system profile.
•
no—The Stinger call-control mechanism ignores the systemwide
setting, allows calls to be established if the line state is
operational, and disallows calls on the port if the line state is
down.
•
yes—The Stinger call-control mechanism ignores the line state
and the systemwide setting and allows calls to be established on
the specified port as long as the specified slot is operational and
the specified port is enabled.
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring the SHDSL/HDSL2 32-Port LIM
Checking the status of an SHDSL/HDSL2 interface
admin> write
SDSL/{ shelf-1 slot-12 1 } written
Checking the status of an SHDSL/HDSL2 interface
A Stinger unit creates an hdsl2-stat profile for each SHDSL/HDSL2 interface in the
system. Following is an example for an active line (line 1 in this case) connected to LIM in
slot 6:
[in HDSL2-STAT/{ shelf-1 slot-6 1 }]
physical-address* = { shelf-1 slot-6 1 }
line-state = active
spare-physical-address = { any-shelf any-slot 0 }
sparing-state = sparing-none
sparing-change-reason = unknown
sparing-change-time = 0
sparing-change-counter = 0
vpi-vci-range = vpi-0-7-vci-32-255
vp-switching-vpi = 7
physical-status = { 95 coe g-shdsl port-up 2312000 "R110 " 0 }
physical-statistic = { { 0 0 55 } yes 42 2 passed 7 in-sync 0 0 0 0 0 0
}
Checking the status of the physical interface
An hdsl2 profile’s physical-status subprofile provides information about the physical
interface. For example:
admin> list physical-status
[in HDSL2-STAT/{ shelf-1 slot-2 10 }:physical-status]
if-group-index = 0
unit-type = cpe
dev-line-state = port-up
operational-rate = 1544000
firmware-ver = A100
hardware-ver = 1
Parameter
Indicates
if-group-index
SNMP interface group index of the line.
unit-type
Operating mode specified by the unit-type parameter in the
hdsl2 profile.
interface-type
Whether the module is operating in SHDSL mode (g-shdsl),
HDSL2 mode (hdsl2), or if the module is not an
SHDSL/HDSL2 LIM (default).
dev-line-state
Current state of the interface, which can be one of the following:
Configuring the SHDSL/HDSL2 32-Port LIM
Checking the status of an SHDSL/HDSL2 interface
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
1-15
Obtaining statistics about operations
An hdsl2-stat profile’s physical-statistic subprofile enables administrators to
check interface operations, as in the following example :
admin> list physical-statistic
[in HDSL2-STAT/{ shelf-1 slot-2 10 }:physical-statistic]
line-up-timer = { 0 0 3 }
rx-signal-present = yes
line-quality = 36
up-dwn-cntr = 3
self-test = passed
transmit-power = 10
framer-sync-status = in-sync
code-violations = 17
errored-second = 2
severely-errored-second = 1
losw-second = 1
unavailable-second = 0
loop-attenuation = 10
•
port-up—Connected to CPE and data can be transferred.
•
test—Line is in test mode.
•
start-up-handshake—Startup handshake is occurring.
•
start-up-training—Startup training is occurring.
•
start-up-download—Startup download is occurring.
•
idle—Line is idle.
•
down—Line is not currently operational.
•
out-of-service—Line is out of service.
•
unknown—Line status is unknown.
•
analog-loopback—Line is in analog loopback mode.
•
digital-loopback—Line is in digital loopback mode.
operational rate
Data rate for this symmetrical interface. The data rate is currently
fixed at 1.544 Mbps.
firmware-ver
Version number of the SHDSL/HDSL2 firmware.
hardware-ver
Hardware version of the SHDSL/HDSL2 modem.
Parameter
Indicates
Parameter
Indicates
line-up-timer
How long the line has been up (days, hours, and minutes in
{dd hh mm} format).
rx-signal-present
Whether a receiving signal is present (yes or no).
line-quality
Line quality in decibels. A value of -5dB or better is required
for reliable data transfer.
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring the SHDSL/HDSL2 32-Port LIM
Internal and external diagnostic tests and BERT
Internal and external diagnostic tests and BERT
You can use the internal diagnostic test to identify problems that might occur during data
transfer between the control module (CM) and line interface modules (LIMs). If the internal
diagnostic test (IDT) feature is enabled for a line, the system generates a data stream internally
from the control module and sends it to that line. The line loops the data back to the control
module. The control module then analyzes the data and reports the statistics in the
line-diag-stat profile.
You can run a bit-error-rate test (BERT) to check the data integrity of the interface or
connection. While a BERT is running, normal data transmission is interrupted on the line.
The line-diag profile contains the parameters that you use to configure a line for an IDT
and a BERT. Following is a listing of the profile, shown with default values:
[in LINE-DIAG/{ shelf-1 slot-2 1 }]
up-down-cntr
Number of times the link has transitioned from an up state to
a down state since the module was last reset.
self-test
Outcome of modem chipset self-test.
transmit-power
Current transmission power that the transceiver is using,
reported in dBm.
framer-sync-status
State of the HDSL2 framer. Provides troubleshooting
information and can assist in determining loss of signal
(LOS). This parameter reports one of the following values:
•
in-sync—Framer is in sync. The HDSL2 framers are
successfully transmitting HDSL2 frames.
•
out-of-sync—HDSL2 framer is out of sync and is
not trying to gain sync.
code-violations
Number of HDSL2 cyclic redundancy check (CRC)
anomalies occurring during the accumulation period.
errored-second
Number of 1-second intervals during which one or more
CRC anomalies are declared and/or one or more loss of
synchronous word (LOSW) defects are declared.
severely-errored-
second
Number of 1-second intervals during which at least 50 CRC
anomalies are declared or one or more LOSW defects are
declared.
losw-second
Number of 1-second intervals during which one or more
HDSL2 LOSW defects are declared.
unavailable-second
Number of 1-second intervals for which the HDSL2 line is
unavailable. The HDSL2 line becomes unavailable at the
onset of 10 contiguous severely errored seconds (SES)-Ls.
Once unavailable, the HDSL2 line becomes available at the
onset of 10 contiguous seconds with no SES-Ls.
loop-attenuation
Current loop attenuation in decibels.
Parameter
Indicates
Configuring the SHDSL/HDSL2 32-Port LIM
Internal and external diagnostic tests and BERT
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
1-17
physical-address* = { shelf-1 slot-2 1 }
bert-timer = 1 minute
bert-enable = no
idt-enable = no
idt-num-of-msg = 1000
The line-diag-stat profile reports the statistics obtained from the IDT and BERT and
the status of the test. Following is a listing of the profile, shown with sample read-only values:
[in LINE-DIAG-STAT/{ shelf-1 slot-2 1 }]
physical-address* = { shelf-1 slot-2 1 }
bert-operation-state = stopped
idt-operation-state = stopped
bert-error-counter = 0
idt-send-count = 0
idt-recv-count = 0
idt-error-counter = 0
Parameter
Specifies
bert-timer
Duration of the bit error rate test (BERT). Specify one of the
following values:
•
1 minute (the default)
•
2 minutes
•
3 minutes
•
4 minutes
•
5 minutes
•
10 minutes
•
15 minutes
•
20 minutes
•
30 minutes
bert-enable
Enable/disable BERT. (Note that a BERT disrupts data
transmission.) Specify one of the following values:
•
no (default)—Line is disabled for BERT.
•
yes—Line is enables for BERT.
idt-enable
Whether internal diagnostic testing is enabled on the line.
•
no (default)—Line is disabled for loopback testing.
•
yes—Enables internal diagnostic testing on the line.
idt-num-of-msg
Number of messages that the control module sends to the line.
Each message corresponds to four ATM cells. The data payload of
each message consists of sequential numeric data. By default, the
value of this parameter is set to 1000. Enter a value from 0 to
10000.
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring the SHDSL/HDSL2 32-Port LIM
Internal and external diagnostic tests and BERT
Configuring an internal diagnostic test (IDT)
To configure a line for internal diagnostic testing, set the idt-enable parameter to yes and
set the idt-num-of-msg parameter to specify the number of test messages to be sent For
example:
admin> read line-diag {1 2 1}
LINE-DIAG/{ shelf-1 slot-2 1 } read
admin> list
[in LINE-DIAG/{ shelf-1 slot-2 1 }]
admin> set idt-enable = yes
admin> set idt-num-of-msg = 1000
admin> write
You can view the results of the internal diagnostic test by displaying the contents of the
line-diag-stat profile, as shown in the following example:
admin> read line-diag-stat {1 2 1}
LINE-DIAG-STAT/{ shelf-1 slot-2 1 } read
Parameter
Specifies
bert-operation-
state
State of the BERT when it is enabled and the BERT timer has not
expired. This parameter reports one of the following states:
•
waiting-for-511-sync—Waiting for remote
synchronization before starting the BERT.
•
local-loop-active—The interface is in local analog
loopback and is running the test. No remote device is
involved.
•
active—BERT is running with remote device.
•
stopped—BERT was disabled.
•
loop-back-setup—The interface is being put into analog
loopback.
•
start-up—BERT is starting up.
bert-error-
counter
Number of bit errors counted by BERT.
idt-operation-
state
Whether an internal diagnostic test is active on the line. (This
parameter is read only.)
•
stopped (default)—The test is inactive.
•
active—The line is undergoing internal diagnostic testing.
idt-send-count
Number of messages sent from the LIM to the control module.
(This parameter is read only.)
idt-recv-count
Number of messages received by the control module. (This
parameter is read only.)
idt-error-counter
Number of erroneous messages received by the control module.
(This parameter is read only.)
Configuring the SHDSL/HDSL2 32-Port LIM
Internal and external diagnostic tests and BERT
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
1-19
admin> list
[in LINE-DIAG-STAT/{ shelf-1 slot-2 1 }]
physical-address* = { shelf-1 slot-2 1 }
bert-operation-state = stopped
idt-operation-state = stopped
bert-error-counter = 0
idt-send-count = 1000
idt-recv-count = 1000
idt-error-counter = 0
If you attempt to change the setting of the idt-enable parameter while an internal
diagnostic test is active for a line, the system generates a warning message, as in the following
example:
admin> set idt-enable = no
admin> write
LOG warning, Shelf 1, Controller-1, Time: 20:12:30--
IDT Test for {1 3 1} is running !
LINE-DIAG/{ shelf-1 slot-3 1 } written
Configuring a bit-error rate test (BERT)
To run a BERT, set the bert-enable parameter to yes. The test counts bit errors
continuously for the interval specified by the bert-timer parameter. If both the CPE and
COE are connected and have BERT enabled, the test runs between the two systems. If the two
ends are not connected, the test runs within the SHDSL/HDSL2 interface in the Stinger unit.
Following is an example of setting up a BERT:
[in LINE-DIAG/{ shelf-1 slot-4 1 }]
admin> set bert-timer = 5
admin> set bert-enable = yes
admin> write
LINE-DIAG/{ shelf-1 slot-4 1 } written
To view the status and results of the BERT, display the contents of the line-diag-stat
profile for the tested line.
Configuring an external diagnostic test (EDT)
The external diagnostic test (EDT) feature puts the DSL modem into loopback mode. If a
complete circuit is established, you can then send a data stream from an external device (such
as a network traffic generator) through the trunk to the modem. The modem loops back the
data stream to the external device, where it can be analyzed. The loop-back parameter is
described in “Configuring port settings for SHDSL and HDSL2” on page 1-5.
[in HDSL2/{ shelf-1 slot-2 1 }:line-config]
loop-back = none
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring the SHDSL/HDSL2 32-Port LIM
Internal and external diagnostic tests and BERT
You configure a line for external diagnostic testing by putting it loopback mode, as shown in
the following example:
admin> read hdsl2 {1 1 1}
HDSL2/{ shelf-1 slot-1 1 } read
admin> set loop-back = analog
admin> write
Digital loopback
When a line is enabled for digital loopback, data is looped only at the digital circuitry of the
modem. Data does not reach the analog circuitry, as shown in Figure 1-2.
Figure 1-2. Data passes through a modem’s digital circuitry (digital loopback).
Analog loopback
When the line is enabled for analog loopback, the data passes from the digital circuitry to
analog circuitry and is then looped back, as shown in Figure 1-3. Analog loopback tests more
circuitry.
Figure 1-3. Data passes through a modem’s digital circuitry and analog circuitry
(analog loopback).
The following example puts a line into analog loopback mode:
admin> read hdsl2 {1 1 1}
HDSL2/{ shelf-1 slot-1 1 } read
admin> set loop-back = analog
admin> write
DSL loop
Analog
(hybrid)
circuitry
Digital
circuitry
DSL loop
DSL loop
Analog
(hybrid)
circuitry
Digital
circuitry
DSL loop
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
2-1
2
Configuring LIM and LIM Port Redundancy
All Stinger line interface modules (LIMs), except the T1 and E1 LIMs, support LIM and LIM
port redundancy in both manual and automatic mode.
You can configure LIM and LIM port redundancy for more than one kind of LIM in a single
Stinger chassis. For example, a single Stinger unit with both asymmetric digital subscriber line
(ADSL) and symmetric digital subscriber line (SDSL) LIMs can be configured with a spare
ADSL LIM and a spare SDSL LIM.
Overview of LIM and LIM port redundancy
A spare LIM can replace an entire failed LIM or a single failed port. LIM redundancy transfers
all logical connections from a failed LIM to the spare LIM. LIM port redundancy transfers the
logical connection from a particular failed port on a LIM to the corresponding port on the spare
LIM. The remaining ports on the spare LIM remain available to provide additional LIM port
redundancy.
Each LIM to be used as a spare must have either a path selector module (PSM) or copper loop
test (CLT) module plugged in behind or next to it in place of a line protection module (LPM).
All other LIMs must use an LPM with port redundancy (LPM-RP) for line protection.
Note: Some older Stinger systems are equipped with an interface redundancy module (IRM)
located behind the spare LIM, and LPMs with redundancy (LPM-R) located behind the LIMs
to be backed up. In this case, additional configuration steps might be needed. For more
information, see “LIM redundancy with IRMs and LPM-Rs” on page 2-7.
Configuring LIM redundancy
LIM redundancy provides a one-to-one backup function for LIMs. Each type of LIM to be
backed up requires a spare LIM with a PSM or CLT module plugged in behind or next to it. For
example, a Stinger FS configured with 14 ADSL 24-port LIMs can be set up with the
following module pairs:
•
13 pairs each consisting of an ADSL LIM and an LPM-RP
•
1 pair consisting of an ADSL LIM and a PSM or CLT module
Overview of LIM and LIM port redundancy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Configuring LIM redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Configuring LIM port redundancy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring LIM and LIM Port Redundancy
Configuring LIM redundancy
The resulting system has 13 active ADSL LIMs and one spare that can be substituted for any
one of the 13 LIMs if a failure occurs.
In the same way, a system can be set up with the following module pairs:
•
6 SDSL LIM–LPM-RP pairs
•
1 SDSL–PSM pair or SDSL–CLT module pair
•
6 ADSL LIM–LPM-RP pairs
•
1 ADSL–PSM pair or ADSL–CLT module pair
The resulting system has 6 active SDSL LIMs and 6 active ADSL LIMs, with 1 spare LIM of
each type available in case of failure.
When the redundancy function is invoked, the primary LIM is deactivated. Its logical
connections are terminated and reestablished on the spare (secondary) LIM. When the
redundancy function is disabled, the spare LIM is deactivated. Its logical connections are
terminated and reestablished on the primary LIM.
Figure 2-1 illustrates LIM redundancy for a failed SDSL LIM in slot 4 of a Stinger FS chassis.
A Stinger LS chassis has its LPMs and PSMs or CLT modules next to its LIMs rather than
behind them.
Figure 2-1. LIM redundancy on a Stinger FS
Overview of the LIM-Sparing-Config profile
When a Stinger unit is booted, it checks for the presence of PSMs or CLT modules. A
LIM-Sparing-Config profile is created for each PSM or CLT module detected. You manage
Configuring LIM and LIM Port Redundancy
Configuring LIM redundancy
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
2-3
LIM redundancy by configuring the LIM-Sparing-Config profile on a spare LIM of the same
type as the LIM to be backed up.
Following is a listing of a LIM-Sparing-Config profile with all parameters set to their default
values:
[in LIM-SPARING-CONFIG/{ any-shelf any-slot 0 }]
physical-address* = { any-shelf any-slot 0 }
spare-slot-type = none
sparing-mode = inactive
spare-slot-number = slot-16
manually-spared-slot-number = any-slot
auto-lim-sparing-config = { [ { yes 10 100 12 } { yes 10 100 12 } { yes
10 100 +
The Auto-LIM-Sparing-Config subprofiles are discussed in “Automatic LIM redundancy” on
page 2-5.
For example, suppose a Stinger unit is configured with an ADSL LIM in slot 1 and an SDSL
LIM in slot 4. Slot 14 contains a spare ADSL LIM with a PSM, and slot 16 contains a spare
SDSL LIM also with a PSM.
The system creates two LIM-Sparing-Config profiles like the following:
admin> dir lim-sparing-config
72 06/20/1999 01:21:15 { shelf-1 slot-14 0 }
72 06/21/1999 17:14:09 { shelf-1 slot-16 0 }
Parameter
Specifies
spare-slot-type
Type of spare LIM installed in the slot. This value is
automatically detected and set by the software when the
Stinger powers up.
sparing-mode
Enable/disable redundancy. You can enable two LIM
redundancy modes.
The inactive setting disables the LIM redundancy
function.
The manual setting deactivates the LIM specified in the
manually-spared-slot-number parameter,
terminating its connections and then reestablishing them on
the spare LIM. For more information, see “Manual LIM
redundancy” on page 2-4.
The automatic setting allows automatic LIM redundancy
to be activated as defined in the Auto-LIM-Sparing-Config
subprofile. See “Automatic LIM redundancy” on page 2-5.
spare-slot-number
Number of the slot containing the spare LIM and PSM or
CLT module. This value is automatically set by the software
when the Stinger unit is turned on.
manually-spared-slot-
number
Slot number of the primary LIM to be manually deactivated
and replaced by the spare LIM.
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring LIM and LIM Port Redundancy
Configuring LIM redundancy
The spare ADSL LIM has the following profile:
admin> read lim-sparing-config { 1 14 0 }
LIM-SPARING-CONFIG/{ shelf-1 slot-14 0 } read
admin> list
[in LIM-SPARING-CONFIG/{ shelf-1 slot-14 0 }]
physical-address* = { shelf-1 slot-14 0 }
spare-slot-type = al-dmtadsl-atm-card
sparing-mode = inactive
spare-slot-number = slot-14
manually-spared-slot-number = slot-any
auto-lim-sparing-config = { [ { yes 10 100 12 } { yes 10 100 12 } { yes
10 100 +
Similarly, you can display the profile for the spare SDSL LIM:
admin> read lim-sparing-config { 1 16 0 }
LIM-SPARING-CONFIG/{ shelf-1 slot-16 0 } read
admin> list
[in LIM-SPARING-CONFIG/{ shelf-1 slot-16 0 }]
physical-address* = { shelf-1 slot-16 0 }
spare-slot-type = sdsl-atm-card
sparing-mode = inactive
spare-slot-number = slot-16
manually-spared-slot-number = slot-any
auto-lim-sparing-config = { [ { yes 10 100 12 } { yes 10 100 12 } { yes
10 100 +
Manual LIM redundancy
You can invoke the redundancy function manually by setting the sparing-mode parameter
to manual. To disable manual redundancy, set the sparing-mode parameter to
inactive.
If manual redundancy is currently in use, setting the parameter to inactive causes the spare
LIM to become inactive again, terminating its connections and then reestablishing them on the
primary LIM that was replaced.
For example, suppose that the SDSL LIM in slot 4 fails (see Figure 2-1). To enable the spare
SDSL LIM in slot 16, proceed as follows:
admin> read lim-sparing-config { 1 16 0 }
LIM-SPARING-CONFIG/{ shelf-1 slot-16 0 } read
admin> set manually-spared-slot-number = 4
admin> set sparing = manual
admin> write
LIM-SPARING-CONFIG/{ shelf-1 slot-160 } written
LOG notice, Shelf 1, Slot 8, Time: 01:30:02--
LIM 16 ACTIVATED as spare for LIM 4
Configuring LIM and LIM Port Redundancy
Configuring LIM redundancy
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
2-5
Automatic LIM redundancy
Automatic LIM redundancy detects a LIM failure and automatically sets up all the virtual
channels of that LIM on the spare. When automatic LIM redundancy is activated, the primary
LIM is monitored. If modem errors exceed the specified thresholds, all connections to the
primary LIM are transferred to the spare (secondary) LIM.
Monitoring continues on the secondary LIM. If modem errors exceed thresholds, the
connections are transferred back to the primary LIM and the automatic redundancy process
stops. You can restart the process by resetting the system or by setting the sparing-mode
parameter to inactive and then back to automatic.
The parameters related to automatic LIM redundancy are found in the
Auto-LIM-Sparing-Config subprofiles. The subprofiles are numbered according to the LIM
slot numbers. These subprofiles apply only to those LIMs that are of the same type as the LIM
specified by the spare-slot-type parameter in the LIM-Sparing-Config profile.
For example, suppose slot 16 in a Stinger FS contains a spare SDSL LIM, slots 1 through 7
contain SDSL LIMs, but slots 10 through 15 contain ADSL LIMs. Only the parameters
contained in LIM-Sparing-Config subprofiles 1 through 7 are applied to automatically replace
the SDSL LIMs in slots 1 through 7.
Note: Following an automatic LIM or LIM port redundancy switchover, some sessions might
not start up even though the physical port switchover is successful.
Following is a listing of an Auto-LIM-Sparing-Config subprofile with all parameters set to
their default values:
[in LIM-SPARING-CONFIG:auto-lim-sparing-config:lim-sparing-config[1]]
active = yes
error-averaging-period = 10
error-threshold = 100
up-down-threshold = 3
modem-failure-threshold = 12
Parameter
Specifies
active
When redundancy mode is set to automatic, this
parameter enables or disables the LIM slot to participate in
automatic LIM redundancy. Only slots for which this
parameter is set to yes can be backed up by the spare. The
default value is yes.
error-averaging-period
Number of seconds during which the number of errors
specified by error-threshold must be observed on
the line before the modem is considered nonfunctional.
The default value is 10.
error-threshold
Number of errors to occur during the specified
error-averaging-period interval before a modem
on this LIM is considered nonfunctional. The default
value is 100.
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring LIM and LIM Port Redundancy
Configuring LIM redundancy
To activate automatic LIM redundancy for a particular LIM, you must set the following two
parameters:
•
In the LIM-Sparing-Config profile for the spare LIM, set the following active
parameter to yes: Auto-LIM-Sparing-Config > LIM-Sparing-Config
[slot number of backed-up LIM] > active.
•
In the LIM-Sparing-Config profile for the spare LIM, set the sparing-mode parameter
to automatic.
For example, if you install a spare SDSL LIM in slot 15 of a Stinger FS unit and want to
activate automatic LIM redundancy for the SDSL LIMs in slots 1 through 7, proceed as
follows:
1
List the Auto-LIM-Sparing-Config profile for slot 1.
admin> list 1
[in LIM-SPARING-CONFIG/{ shelf-1 slot-15 0}
:auto-lim-sparing-config:lim-sparing-config[1]]
active = yes
error-averaging-period = 10
error-threshold = 100
up-down-threshold = 3
modem-failure-threshold = 12
Because the Auto-LIM-Sparing-Config subprofiles are numbered according to the LIM
slot numbers, the list 1 command here lists the LIM-Sparing-Config subprofile for the
LIM in slot 1.
Note that the active parameter is set to yes. Because this is the default value for all
seven slots, you do not have to set it unless you have previously changed it.
2
Set the redundancy mode.
admin> list
[in LIM-SPARING-CONFIG/{ shelf-1 slot-15 0 }]
physical-address* = { shelf-1 slot-15 0 }
spare-slot-type = sdsl-atm-card
sparing-mode = inactive
spare-slot-number = slot-15
manually-spared-slot-number = any-slot
auto-lim-sparing-config = { [ { yes 10 100 3 12 } { yes 10}]}
admin> set sparing-mode = automatic
admin> write
LIM-SPARING-CONFIG/{ shelf-1 slot-15 0 } written
up-down-threshold
Number of times during the specified
error-averaging-period interval that the line is
connected and disconnected by the modem before the
modem is considered nonfunctional. The default value
is 3.
modem-failure-threshold Number of modems on this LIM that are considered
nonfunctional before this LIM is considered
nonfunctional. The default value is 12.
Parameter
Specifies
Configuring LIM and LIM Port Redundancy
Configuring LIM redundancy
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
2-7
Assuming that the active parameters in the LIM-Sparing-Config subprofiles for slots 2
through 7 are also set to the default, LIM redundancy is now activated for the SDSL LIMs in
slots 1 through 7.
LIM redundancy with IRMs and LPM-Rs
When you upgrade the software to TAOS 7.11.4 or later, a previously existing
LIM-Sparing-Config profile is automatically converted to a redundancy profile indexed to the
spare LIM slot. Use the dir lim-sparing-config command to verify that the profile
has been created.
For example, suppose a Stinger FS already has a spare SDSL LIM and IRM installed and
configured in slot 16 before the software upgrade. Enter the dir command to show the profile:
admin> dir lim-sparing-config
213 06/20/1999 02:25:18 { shelf-1 slot-16 0 }
Then list the profile:
admin> read lim-sparing-config { 1 16 0 }
admin> list
[in LIM-SPARING-CONFIG/{ shelf-1 slot-16 0 } ]
physical-address* = { shelf-1 slot-16 0 }
spare-slot-type = sdsl-atm-card
sparing-mode = inactive
spare-slot-number = slot-16
manually-spared-slot-number = any-slot
if-sparing-config = [ any-slot any-slot any-slot any-slot any-slot
any-slot any+
auto-lim-sparing-config = { [ { yes 10 100 3 12 } { yes 10 100 3 12 } {
yes 10 +
If a profile exists, nothing further needs to be done until the LIM redundancy function is
activated. If no profile exists, you must create the profile manually for the slot number
containing the spare LIM and IRM. All the LIMs to be backed up must have either LPM-Rs or
LPM-RPs installed in the slots behind or next to them.
When the profile is created, the software automatically assigns a value to the
spare-slot-type and spare-slot-number parameters.
For example, if a Stinger has an SDSL LIM and an IRM installed in slot 16, and it also has an
SDSL LIM with an LPM-R installed in slot 4, you must first create a LIM-Sparing-Config
profile for slot 16:
admin> new lim-sparing-config { 1 16 0 }
LIM-SPARING-CONFIG/{ shelf-1 slot-16 0 } read
admin> write
LIM-SPARING-CONFIG/{ shelf-1 slot-16 0 } written
admin> list
[in LIM-SPARING-CONFIG/{ shelf-1 slot-16 0 } (new)]
physical-address* = { shelf-1 slot-16 0 }
spare-slot-type = sdsl-atm-card
sparing-mode = inactive
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring LIM and LIM Port Redundancy
Configuring LIM redundancy
spare-slot-number = slot-16
manually-spared-slot-number = any-slot
if-sparing-config = [ any-slot any-slot any-slot any-slot any-slot
any-slot any+
auto-lim-sparing-config = { [ { yes 10 100 3 12 } { yes 10 100 3 12 } {
yes 10 +
Suppose the SDSL LIM in slot 4 fails. You can then activate manual LIM redundancy as
follows:
admin> set manually-spared-slot-number = 4
admin> set sparing-mode = manual
admin> write
LIM-SPARING-CONFIG/{ shelf-1 slot-16 0 } written
LOG notice, Shelf 1, Slot 8, Time: 26:30:01--
LIM 16 ACTIVATED as spare for LIM 4
Checking LIM redundancy status
You can check the status of LIM redundancy by examining the LIM-Sparing-Status profile.
Following are the parameters with sample values:
[in LIM-SPARING-STATUS]
spare-slot-type = none
sparing-mode = inactive
spare-slot-number = any-slot
spared-slot-number = any-slot
sparing-change-reason = unknown
sparing-change-time = 0
sparing-change-counter = 0
lim-sparing-status = [ { yes yes sparing-none } { yes yes sparing-none
} { yes +
A LIM-Sparing-Status subprofile is defined for each slot as follows:
[in LIM-SPARING-STATUS:lim-sparing-status[1]]
active = yes
lim-status-ok = yes
sparing-state = sparing-none
Parameter
Indicates
spare-slot-type
Shelf, slot, and port number of the spare LIM.
sparing-mode
State of the redundancy function. If redundancy is not
enabled, sparing-none is the value. If redundancy is
enabled and the LIM slot is a primary LIM, the value can
be primary-active or primary-inactive. If
redundancy is enabled and the LIM slot is the secondary
(spare) LIM, the value can be secondary-active or
secondary-inactive.
spare-slot-number
Slot number of the spare LIM for that type of LIM.
spared-slot-number
Slot number of the LIM being replaced by the spare LIM.
Configuring LIM and LIM Port Redundancy
Configuring LIM redundancy
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
2-9
Checking status with the Rearslot command
The rearslot command shows the status of all the slots used for LPMs, PSMs, and CLT
modules. It also reports on the status of the midplane redundancy bus. Slots that are equipped
with IRMs or LPM-Rs are reported as Empty by the rearslot command.
Note: When a copper loop is being tested on a Stinger LS with a PSM or a CLT module, the
rearslot command does not display any midplane sparing bus usage.
For example, suppose that a Stinger FS is equipped with ADSL LIMs and SDSL LIMs. The
ADSL 24-port LIM in slot 1 has failed and is being replaced by the ADSL 24-port LIM in
slot 14. The rearslot command reports the following.
admin> rearslot
Slot Slot ID
[ 1 ] 91 24 port Enhanced LPM
[ 2 ] 0 Empty ( IRM, LPM )
[ 3 ] 0 Empty ( IRM, LPM )
[ 4 ] 92 48 port Enhanced LPM)
[ 5 ] 0 Empty ( IRM, LPM )
[ 6 ] 0 Empty ( IRM, LPM )
[ 7 ] 0 Empty ( IRM, LPM )
[ 10 ] 0 Empty ( IRM, LPM )
[ 11 ] 0 Empty ( IRM, LPM )
[ 12 ] 0 Empty ( IRM, LPM )
[ 13 ] 0 Empty ( IRM, LPM )
[ 14 ] 93 Path Selector Module ( PSM )
[ 15 ] 0 Empty ( IRM, LPM )
[ 16 ] 94 Copper Loop Tester ( CLT )
sparing-change-reason
How redundancy is activated. Valid values are
inactive, automatic, and manual.
sparing-change-time
Time that the last change in redundancy state occurred.
sparing-change-counter Number of redundancy changes (for example, primary to
secondary or secondary to primary). The counter is reset
to zero each time the Stinger is turned on.
active
Valid values are yes and no.
lim-status-ok
Valid values are yes and no.
sparing-state
State of the redundancy function. If redundancy is not
enabled, sparing-none is the value. If redundancy is
enabled and the LIM slot is a primary LIM, the value can
be primary-active or primary-inactive. If
redundancy is enabled and the LIM slot is the secondary
(spare) LIM, the value can be secondary-active or
secondary-inactive. A value of
not-applicable indicates that LIM redundancy is not
applicable to this module.
Parameter
Indicates
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring LIM and LIM Port Redundancy
Configuring LIM port redundancy
Midplane sparing bus usage :
4 4 3 2 1
8765 4321 0987 6543 2109 8765 4321 0987 6543 2109 8765 4321
.... .... .... .... .... .... XXXX XXXX XXXX XXXX XXXX XXXX
Configuring LIM port redundancy
LIM port redundancy allows an individual port of a LIM to be backed up by the corresponding
port of a spare LIM. The LIM to be backed up (the primary LIM) must be of the same type as
the spare. The remaining ports on the spare LIM remain available to back up other failed ports
on any LIMs of the same type in the system.
More than one kind of LIM port can be backed up. An additional LIM-PSM pair (or LIM-CLT
module pair) of another type installed in a Stinger can be used to back up other LIMs of that
type in the system. For example, a spare SDSL LIM in slot 16 can back up any failed port on
any other SDSL LIMs in a Stinger FS chassis. Likewise, a spare ADSL LIM in slot 14 can
back up any failed ADSL ports.
However, because the midplane redundancy bus in a Stinger chassis contains only one path for
each port number, port redundancy can back up only one path of a particular number at a time.
For example, suppose port 1 on an SDSL LIM fails and is replaced. As long as redundancy is
active on that port, no other failed SDSL or ADSL port 1 on that unit can be replaced by a
spare LIM port.
For example, port 2 on an ADSL LIM in slot 1 can be backed up by port 2 of the spare ADSL
LIM in slot 14. A subsequent failure of port 6 on an SDSL LIM in slot 4 can be backed up by
port 6 on the spare SDSL LIM in slot 16. This example is illustrated for a Stinger FS chassis in
Figure 2-2. A Stinger LS chassis has its LPMs and PSMs or CLT modules next to its LIMs
rather than behind them.
Note: Following an automatic LIM or LIM port redundancy switchover, some sessions might
not start up even though the physical port switchover is successful.
Configuring LIM and LIM Port Redundancy
Configuring LIM port redundancy
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
2-11
Figure 2-2. LIM port redundancy on a Stinger FS
When a port on a LIM that is being backed up is replaced, the virtual channels for that port are
terminated and set up on the spare. All other line parameters are also transferred to the spare
port.
Enabling LIM port redundancy
Redundancy for a particular slot and port is controlled by the sparing-mode parameter in
the appropriate LIM profile.
The sparing-mode parameter appears in all LIM profiles, as in the following SDSL profile
for slot 2, port 6:
[in SDSL/{ shelf-1 slot-2 6 }]
name = 1:2:32
physical-address* = { shelf-1 slot-2 6 }
enabled = yes
sparing-mode = inactive
line-config = { 0 232 15 static { any-shelf any-slot 0 }
singlebaud 784000 2720+
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring LIM and LIM Port Redundancy
Configuring LIM port redundancy
Manual LIM port redundancy
You can invoke the redundancy function manually by setting the sparing-mode parameter
in the LIM profile to manual. The connection on the primary LIM is transferred to the spare
(secondary) LIM. To disable manual port redundancy, set the sparing-mode parameter to
inactive.
If manual redundancy is currently in use, setting the parameter to inactive causes the spare
LIM port to become inactive again, terminating its connections and then reestablishing them
on the primary LIM port that was replaced.
For example, suppose a Stinger FS is equipped with an ADSL LIM in slot 1 and an SDSL LIM
in slot 4. Spare LIMs are located in slots 14 and 16 respectively. Port 2 fails on the ADSL LIM,
and port 6 fails on the SDSL LIM. To provide redundancy for these ports, proceed as follows:
1
Activate redundancy for failed port 2 in slot 1.
admin> read al-dmt {1 1 2}
admin> set sparing-mode = manual
admin> write
LOG notice, Shelf 1, Slot 8, Time: 11:58:49--
LIM 14 port 2 ACTIVATED as spare for LIM 1 Port 2
2
Activate redundancy for failed port 6 in slot 4.
admin> read sdsl {1 4 6}
admin> set sparing-mode = manual
admin> write
LOG notice, Shelf 1, Slot 8, Time: 12:07:51--
LIM 16 port 6 ACTIVATED as spare for LIM 4 Port 6
Automatic LIM port redundancy
Automatic LIM port redundancy detects a LIM port failure and automatically transfers the port
connection to the same port on the spare LIM. When automatic LIM port redundancy is
activated, the primary LIM port is monitored. If modem errors exceed the specified thresholds,
the port connection to the primary LIM is transferred to the spare (secondary) LIM.
Monitoring continues on the secondary LIM port. If modem errors again exceed thresholds, the
connection is transferred back to the primary LIM port and the automatic redundancy process
Parameter
Specifies
sparing-mode
Enables or disables port redundancy and specifies the mode. You can
enable two port-redundancy modes.
The default value, inactive, disables LIM port redundancy.
The manual setting deactivates the LIM port and then reestablishes the
connection on the same port of the spare LIM.
The automatic setting activates automatic redundancy for the port.
The error threshold parameters specified in the
Auto-LIM-Sparing-Config subprofile of the LIM-Sparing-Config [slot
number] profile are used.
Configuring LIM and LIM Port Redundancy
Configuring LIM port redundancy
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
2-13
stops. You can restart the process by resetting the system or by setting the sparing-mode
parameter to inactive and then back to automatic.
The parameters used for automatic LIM port redundancy are found in the
Auto-LIM-Sparing-Config subprofile of the LIM-Sparing-Config profile for the spare LIM of
the same type.
For example, suppose you want to set up automatic port redundancy for port 1 in an SDSL
LIM in slot 5 with an error threshold of 50. The spare SDSL LIM is located in slot 16 of a
Stinger FS.
The threshold parameters reside in the Auto-LIM-Sparing-Config subprofile of the
LIM-Sparing-Config profile in slot 16.
1
List the parameters.
admin> list 1
[in LIM-SPARING-CONFIG/{ shelf-1 slot-16 0
}:auto-lim-sparing-config:lim-sparing-config[1]]
active = yes
error-averaging-period = 10
error-threshold = 100
up-down-threshold = 3
modem-failure-threshold = 12
2
Set the threshold parameter.
admin > set error-threshold = 50
admin > write
SDSL/{ shelf-1 slot-16 0 } written
3
Activate automatic redundancy for port 1 in slot 5.
admin > read sdsl {1 5 1}
admin > set sparing-mode = automatic
admin > write
SDSL/{ shelf-1 slot-5 1 } written
Checking the status of extended LIM port redundancy
The line status profile for a particular LIM shows port redundancy status for the selected port,
and information about a spare LIM if one exists. The LIM line status profiles have five
parameters to indicate the port redundancy status.
Following are the relevant parameters shown with sample settings for an active line using an
SDSL LIM:
[in SDSL-STAT/{ shelf-1 slot-4 6 }]
spare-physical-address = { shelf-1 slot-16 6 }
sparing-state = primary-inactive
sparing-change-reason = manual
sparing-change-time = 309108872
sparing-change-counter = 1
Parameter
Indicates
spare-physical-address
Shelf, slot, and port number of spare LIM.
SHDSL/HDSL2 32-Port Line Interface Module (LIM) Guide
Configuring LIM and LIM Port Redundancy
Configuring LIM port redundancy
sparing-state
State of the redundancy function. If redundancy is not
enabled, sparing-none is the value. If redundancy is
enabled and the LIM slot is a primary LIM, the value can be
primary-active or primary-inactive. If
redundancy is enabled and the LIM slot is the secondary
(spare) LIM, the value can be secondary-active or
secondary-inactive.
sparing-change-reason
How redundancy is activated. Valid values are inactive,
manual, and automatic.
sparing-change-time
Time that the last change in redundancy state occurred.
sparing-change-counter
Number of redundancy changes (for example, primary to
secondary or secondary to primary). The counter is reset to
zero each time the Stinger is turned on.
Parameter
Indicates