Belimo UK24BAC Technical Data Manual
File Specifications
| Brand: | Belimo |
| Category: | Gateway |
| Model: | UK24BAC (Technical Data Manual), prdWrGM0yv3Ic |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 20 pages |
Download PDF
Download Belimo UK24BAC Manual (20 pages)Read Online:
Read the Belimo UK24BAC Technical Data Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
Belimo Gateway MP to BACnet MS/TP
www.belimo.com T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes 19 / 20 ...
Belimo Gateway MP to BACnet MS/TP
12 / 20 T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com PICS (continued) Standard objects (per actuator) The information of the connected actuators is digitized per node in the objects as listed below (whereas n corresponds to the MP address 1-8): 1) This object is commandable. 2) This object supports unsolicited COV. 3) This Present_Value must be periodically updated. Datapoint BACnet Object Air Water VAV EPIV Fire MPL Actuator type MV 2) [n*100+0] Set point [%] AO 1) [n*100+0] Override operatio ...
Belimo Gateway MP to BACnet MS/TP
8 / 20 T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com Operation Legend The illustration shows the operation elements of the device with the front cover open. Setting the BACnet MAC address The BACnet MAC address is set in binary form with the 7 DIP switches under the front cover. The valid address range is 1-127. Values outside of this range will be interpreted as either 1 or 127, respectively. Display of the active MP nodes Addressing of the MP nodes Power LED MP-Bus LED BACnet LED Setting Baud rate Setting BACnet MAC Add ...
Belimo Gateway MP to BACnet MS/TP
www.belimo.com T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes 15 / 20 BACnet object description (continued) Object Name Object Type / Instance Description Values Default MIN_STPT_[n] Analog Value [n*100+1] Minimum limit (position or flow) in % Attention: Changing the limit may result in malfunction of the device. 0…100 - MAX_STPT_[n] Analog Value [n*100+2] Maximum limit (position or flow) in % Attention: Changing the limit may result in malfunction of the device. 20…100 - NOM_FLOW_[n] Analog Value [n*100+3] Nominal volumetric flow (o ...
Belimo Gateway MP to BACnet MS/TP
10 / 20 T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com Operation (continued) Automatic scanning of the MP network The MP-Bus assignment is determined automatically and continuously updated. No backup of the network structure takes place. The actuator information (e.g. series number, actuator type) is extracted as soon as one supported actuator is detected at the addresses MP1…MP8. In the event of a communications interruption, the Gateway will discard the affected actuator after 10 seconds and reset the actuator register ...
Belimo Gateway MP to BACnet MS/TP
6 / 20 T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com Electrical installation (continued) With AC 24 V supply: Calculation of the maximum signal conductor lengths To be read out from the mass of curves: For cables with wire-Ø [mm²] Cable length [m] 0.75 29 1.00 35 1.50 50 2.50 90 The power ratings [VA] of the MP/MPL/MFT(2) actuators used are to be added, and the corresponding signal conductor lengths are to be read from the diagram. Example: The following is connected to the MP-Bus: 1 pc. NM24A-MP, 1 pc. SM24A-MP, 1 pc. ...
Belimo UK24BAC user guide recommended for: 4FXS, UK24MOD, MPD12-HS K Cat.6A, DMG 7000, CTM GateWay.
⚠️ Download Safety
The Gateway Technical data manual (20 pages) is completely safe to download (last scan date: 17/12/2025).
Related PDF Instructions for Belimo UK24BAC:
-
Belimo VRP-M Control Systems Product information
VRP-M28 -
Belimo PRCA-S2-T Controller Technical data sheet
PRCA-S2-T6 -
Belimo LRB24-SR-T Controller Wiring diagrams
LRB24-SR-T2 -
Belimo CR24 Series Controller Manual
CR24 Series4 -
Belimo SRA-100 Switch Technical manual
SRA-1008 -
Belimo LF24 US Controller Quick start manual
LF24 US3
Gateway Equipment: Frequently Requested
-
Sigfox Sigfox Access
Station Micro SMBS-T4 Gateway
22.02.2026Technical operations guide for the Sigfox Sigfox Access Station Micro SMBS-T4 Gateway. It covers testing procedures, safety features, safety information, adjustment procedures.Sigfox Access Station Micro SMBS-T4, 14 -
Centurion SMART GUARD air IP Access Controllers
06.05.2026Instruction guidebook for the Centurion SMART GUARD air IP Access Controllers. It describes usage and safety protocols, error codes, device features.SMART GUARD air, 11 -
Arris SURFboard SBG6580 Modem
14.03.2026Reference manual for the Arris SURFboard SBG6580 Modem. It describes usage and shutdown procedures, internal layout, dimensions and layout, usage tips.SURFboard SBG6580, 74 -
Humanscale OfficeIQ Gateway
19.05.2026Professional user manual for the Humanscale OfficeIQ Gateway. It explains troubleshooting and safety precautions, startup procedures, security instructions.OfficeIQ, 2 -
Nortel MCC3100 Other
14.12.2025Product operation guide for the Nortel MCC3100 Other. The document contains supported accessories, testing procedures, technical guidelines, component replacement.MCC3100, 3 -
RTA 460BMTCP-NNA4 Gateway
20.12.2025Installation and operation manual for the RTA 460BMTCP-NNA4 Gateway. It provides guidance on setup, installation procedures, service procedures.460BMTCP-NNA4, 81
Have some Questions about Belimo UK24BAC Device?
Get valuable and actionable advices from other Belimo UK24BAC device users. Describe your problem or question, regarding the using of UK24BAC, in as much detail as possible, and other users will be able to answer you.