Checkline TI-007X Operating Manual
Text of the manual
ULTRASONIC THICKNESS GAUGE
Operating Manual
Distributed by: ABQ Industrial LP USA
Tel: +1 (281) 516-9292 / (888) 275-5772 eFax: +1 (866) 234-0451
Web: https://www.abqindustrial.net E-mail: [email protected]
TABLE OF CONTENTS
1.0
Introduction...........................................................................................................................
03
1.1 Disclaimer.......................................................................................................................
2.0 Keypad, Menu, Display & Connectors................................................................................
04
2.1 ON/OFF/ENTER Key
2.2 PRB 0 Key
2.3 CAL Key
2.4 GAIN Key
2.5 SCAN Key
2.6 +/- INCREMENT/DECREMENT Keys
2.7 MODE Key
2.8 MENU Key
2.9 The Display
2.10 The Transducer
2.11 Top & Bottom End Caps
3.0 Principals of Ultrasonic Measurement................................................................................
11
3.1 Time versus thickness relationship
3.2 Suitability of materials
3.3 Range of measurement and accuracy
3.4 Couplant
3.5 Temperature
3.6 Measurement modes
4.0 Selecting the measurement mode.........................................................................................
14
4.1 Which Mode and Transducer do I use for my applications?
5.0 Making measurements..........................................................................................................
16
5.1 Probe Zero
5.2 Material Calibration
6.0 Through Pain Measurement - Multimode...........................................................................
22
6.1 Introduction
6.2 Multimode Transducers
7.0 Velocity Gauge.......................................................................................................................
23
6.1 Velocity Gauge (VX)
6.2 Calibration to a known thickness
6.3 Calibration to a known velocity
8.0 Additional features................................................................................................................ 26
8.1 GAIN
8.2 Hight-speed Scan
– 2 –
8.3 Alarm
8.4 Differential
8.5 Units
8.6 Lite
8.7 Beep
8.8 Probe Type
8.9 Velocity (VX)
8.10 Lock
8.11 Factory Defaults
9.0
Data Transfer a& Power Options........................................................................................ 33
9.1 Connectivity
9.2 Installing Serial Driver (CDC)
9.3 Line Power
10.0 Appendix A - Velocity Table.................................................................................................. 36
11.0 Appendix B - Application Notes........................................................................................... 37
12.0 Warranty................................................................................................................................ 30
– 3 –
1.0 INTRODUCTION
The Checkline model TI-007X is a precision ultrasonic micrometer. Based on the same
operating principles as SONAR, the TI-007X is capable of measuring the thickness of
various materials with accuracy as high as ±0.0001 inches, or ±0.001 millimeters. The
principle advantage of ultrasonic measurement over traditional
methods is that ultrasonic measurements can be performed with access to only one
side of the material being measured.
1.1 Disclaimer
While the TI-007X is a basic digital instrument, it is equipped with a number of
measurement modes and transducer options for additional versatility. It is strongly
recommended that the contents of this manual be read in its entirety to avoid erroneous
measurements based on operator error. The user is solely responsible for proper use,
setup and interpretation of the measurements acquired.
– 4 –
2.0 KEYPAD, MENU, DISPLAY & CONNECTORS
The Keypad
2.1 ON/OFF/ENTER Key
The ON/OFF/ENTER key powers the unit ON or OFF. Since the same key is
also used as an ENTER key, the gauge is powered off by pressing and holding
down the key until the unit powers off.
Once the gauge is initially powered on, this key will function as the ENTER key, similar
to a computer keyboard. This key will be used to select or set a menu option.
NOTE: Unit will automatically power off when idle for 5 minutes. All current settings
are automatically saved prior to powering off.
2.2 PRB 0 Key
The PRB 0 key is used to “zero” the TI-007X in much the same way that a
mechanical micrometer is zeroed. If the gauge is not zeroed correctly, all of the
measurements that the gauge makes may be in error by some fixed value. Refer
to section 5.1 for a further explanation of this important feature.
2.3 CAL Key
The CAL key is used to enter and exit the TI-007X ’s calibration mode. This
mode is used to adjust the sound velocity value that the TI-007X will use when
calculating thickness. The tool will either calculate the sound-velocity from a
sample of the material being measured, or allow a known velocity value to be entered
directly. This provides increased linearity between transducers. Refer to section 5.2 for
an explanation on the various calibration options.