Signalling of the locking devices

Electronic handle sets Electronic cylinder English Version VB

1 Signalling during operation

3 1.1 Opening the locking device with a locking medium 3 1.2 Activating the office mode 4 1.3 Deactivating the office mode 5 2 Signalling while using the master media 7 2.1 Authorising System-Master 8 2.2 Authorising additional master media 10 2.3 Deleting master media 12 2.4 Deleting System-Master 14 2.5 Authorising locking media 15 2.6 Deleting locking media authorisations 17 2.7 Deleting all locking media authorisations simultaneously 19 2.8 Setting opening period 20 2.9 Activating release mode 21 2.10 Deactivating release mode 22 2.11 Activating block mode 23 2.12 Deactivating block mode 24 2.13 Activating emergency mode 25 2.14 Deactivating emergency mode 26 2.15 Activating online mode 27 2.16 Deactivating online mode 29 2.17 Checking quality of wireless connection 30 2.18 Transmitting programming jobs with an RF-Stick to a locking device 32 3 Signalling after battery insertion 35 4 Battery warning system 36 5 Error signalling 37 Page 2 of 39 Signalling of OMEGA FLEX Locking devices

1 Signalling during operation

1.1 Opening the locking device with a locking medium Procedure: 1. Hold an authorised locking media for ca. 1 second in the reading field of the locking device (maximum distance ca. 10 mm). The following signal appears: 1x short green and 1x short beep You can open the door by pressing the lever handle for a certain period. The length of the time period depends upon the opening period set. During the opening period no further locking media or master media are read. Only after you hear that the coupling of locking device has disengaged, you can hold another locking media in the reading field of the locking device. Troubleshooting: Signalling Reason Solution The locking media cannot be read (No signal). The locking media was not held close enough to the reading field of the locking device. Hold the locking media longer in the reading field of the locking device. The reading field is shielded by metallic materials. Remove the metallic materials from the reading field of the locking device. Shortly before, another authorised locking media was held in the reading field of the locking device and the opening period of the locking device has not yet expired. You can open the door without having to have your locking media read. The battery is empty. Replace the batteries b) The locking media is defective. Have a new locking media issued by the administrator of the OMEGA FLEX system. Signalling of OMEGA FLEX Locking devices Page 3 of 39 1   Signalling during operation

The locking media is not authorised.

Have the locking media authorised by the administrator of the OMEGA FLEX system. The locking media is authorised but the block time or block mode is active. If the block time or block mode is active, a locking device cannot be opened by an authorised locking media. The locking media is authorised and the locking device is currently in release mode. You can open the door also without an authorised locking media. 1.2 Activating the office mode Required devices and locking media: l Locking media, which is authorised for the office function l Locking device, which is authorised for the office function Procedure: 1. Hold the locking media authorised for the office function for ca 2 seconds in the reading field of the locking device. As soon as the locking media is in the reading field, the following signal appears: 1x short green and 1x short beep After ca 2 second, another signal appears: 1x short green and 1x short beep, 1x long green and 1x long beep The office mode is now active. The door can now be opened until the end of the office hours without locking media. LINE locking device reconnects automatically at the end-time set in the OMEGA Client. Since there are no start and end-times for the Office function in the V-NET, there is no end-time at which the locking device automatically reconnects. Therefore, the office mode in V-NET must be deactivated with an authorised locking media. Page 4 of 39 Signalling of OMEGA FLEX Locking devices 1   Signalling during operation

No signal after ca 2 seconds. The

office mode is not active. The coupling of the locking device engages, but disengages again after expiry of the opening duration. The locking device is not authorised for the office function. Have the locking device authorised for the office function by the system administrator. The office function is not available at this time. Enquire with the system administrator, when the office function in this locking device can be activated. The locking media is not authorised for the office function. Have the locking media authorised for the office function by the system administrator. 1.3 Deactivating the office mode Required devices and locking media: l Locking media, which is authorised for the office function l Locking device, which is authorised for the office function Procedure: 1. Hold the locking media authorised for the office function for ca 2 seconds in the reading field of the locking device. As soon as the locking media is in the reading field, the following signal appears: 1x long green and 1x long beep After ca 2 second, another signal appears: 1x long green and 1x long beep, 1x short green and 1x short beep The office mode is now deactivated. The door can be opened now only with authorised locking media. Troubleshooting: Signalling Reason Solution After 2 seconds The office mode cannot be deactivated Have your locking media authorised for Signalling of OMEGA FLEX Locking devices Page 5 of 39 1   Signalling during operation

because the locking media is not

authorised for the office function. the office function by the system administrator. Page 6 of 39 Signalling of OMEGA FLEX Locking devices 1   Signalling during operation

2 Signalling while using the master media

2.1 Authorising System-Master 8 2.2 Authorising additional master media 10 2.3 Deleting master media 12 2.4 Deleting System-Master 14 2.5 Authorising locking media 15 2.6 Deleting locking media authorisations 17 2.7 Deleting all locking media authorisations simultaneously 19 2.8 Setting opening period 20 2.9 Activating release mode 21 2.10 Deactivating release mode 22 2.11 Activating block mode 23 2.12 Deactivating block mode 24 2.13 Activating emergency mode 25 2.14 Deactivating emergency mode 26 2.15 Activating online mode 27 2.16 Deactivating online mode 29 2.17 Checking quality of wireless connection 30 2.18 Transmitting programming jobs with an RF-Stick to a locking device 32 Signalling of OMEGA FLEX Locking devices Page 7 of 39 2   Signalling while using the master media

2.1 Authorising System-Master

Each locking device of an OMEGAFLEX system must first become familiar with the System - Master of the system so that the System-Master is authorised to authorise additional master media for this locking device. Each OMEGA FLEX system has only one System-Master. Through the system identification code which is stored in the locking device and in the System-Master, it is ensured that only the System- Master belonging to a given system can be authorised for the locking devices of that system. For security reasons, you should authorise the System-Master on all locking devices. If you are using the OMEGA Suite: Ensure that the System-Master has been read into the OMEGA Client. As a result, it is automatically authorised for the locking device during the initial reprogramming of the locking device. Required master media: l System-Master Procedure: 1. Hold the System-Master for ca 1 second in the reading field of the locking device and then remove it from the reading field. The following signal appears: 1x short green and 1x short beep Page 8 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2. Hold the System-Master again for ca 1 second in the reading field of the locking device and

then remove it from the reading field. The following signal appears: 1x long green and 1x long beep The System-Master is now authorised for this locking device. Troubleshooting: Signalling Reason Solution During step 1: The System-Master does not have the cor rect system identification code. Use the System-Master with correct sys tem identification code. During step 2: Another System-Master has already been authorised for this locking device. Since, at any given time only one System-Master exists which can be authorised on the basis of individual system identification code for a locking device, there is reason to suspect manipulation. Contact your CES partner immediately! Signalling of OMEGA FLEX Locking devices Page 9 of 39 2   Signalling while using the master media

2.2 Authorising additional master media

All master media must be authorised prior to their first use. The only exceptions are the RF-Ini- Master (in NET and VA devices) and the RF-Trace-Master. Required master media: l System-Master l Any master media that needs to be authorised Procedure: 1. Hold the System-Master for ca 1 second in the reading field of the locking device to start the “authorise mode” of the locking device. The following signal appears: 1x short green and 1x short beep 2. Now you can authorise any number of master media one after the other by holding each master media for ca 1 second in the reading field of the locking device. The following signal appears for each master media: 1x short green and 1x short beep Page 10 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

3. Hold the System-Master for ca 1 second in the reading field of the locking device to end the

“authorise mode. The following signal appears: 1x long green and 1x long beep The “authorise mode” will end automatically after 5 seconds. Die new authorisations remain stored. All master media, which were held before reading field, are now authorised to make settings for this locking device. Troubleshooting: Signalling Reason Solution During step 2: The master media could be read but could not be authorised: a) You have tried to authorise a Program-Master for a V-NET locking device. a) Program-Master cannot be authorised for V-NET devices. b) The master media has the wrong system identity code b) Use a master media with the correct system identification code. c) You have used a locking media instead of a master-media. c) Use a master media. d) you have tried to authorise an RF- Trace-Master or an RF-Ini-Master. d) RF-Trace-Master and RF-Ini-Master cannot be authorised. Signalling of OMEGA FLEX Locking devices Page 11 of 39 2   Signalling while using the master media

2.3 Deleting master media

The deletion of a Program-Master deletes all locking authorisations which were assigned with this Program-Master. The opening duration set with theTime-Master remains intact even after deletion of the Time-Master. Required master media: l System-Master l Any master media, that needs to be deleted Procedure: 1. Hold the System-Master for ca1 second in the reading field of the locking device to start the “delete master media” mode of the locking device. The following signal appears: 1x short green and 1x short beep Page 12 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2. Now you can delete any number of master media one after the other by holding each

master media for ca 5 second in the reading field of the locking device. The following signal appears for each master media: 2x short green and 2x short beep 3. Hold the System-Master for ca 1 second in the reading field of the locking device to end the “delete master media” mode. The following signal appears: 1x long green and 1x long beep The “delete master media mode” will end automatically after ca 5 seconds. The master media which were previously held before the locking device will be deleted. All master media, which were held in the reading field, are now no longer authorised to make settings for this locking device. Troubleshooting: Signalling Reason Solution During step 2: The master media cannot be deleted because it does not belong to the master media, which mist be authorised. The RF-Ini-Master (for NET and VA devices) and the RF-Trace-Master do not have to be authorised and therefore can not be deleted. The master media was held too short in the reading field of the locking device. The authorisation was not deleted. Keep the master media longer in the read ing field of the locking device. Signalling of OMEGA FLEX Locking devices Page 13 of 39 2   Signalling while using the master media

2.4 Deleting System-Master

Effects of deletion of System-Master l Deletion of the System-Master results in deletion of all master media and locking author isations from a locking device. l All settings in the locking device, which were made with the OMEGA Client software (e.g. Time profiles, locking media authorisations etc.), remain intact after deletion of the Sys tem-Master. l Deletion of the System-Master deactivates all active opening modes of a locking device. Online devices remain in online mode though. l The opening period set with the Time-Master remains intact after deletion of the Time- Master. Required master media: l System-Master Procedure: 1. Hold the System-Master for ca. 5 seconds in the reading field of the locking device. The following signal appears: 2x short green and 2x short beep 2. Remove the System-Master from the reading field of the locking device. It is automatically ensured that no access is possible in that if the coupling of the locking device was engaged, disengages. The System-Master is now deleted from this locking device. Page 14 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2.5 Authorising locking media

Required media: l Program-Master l Any locking media that needs to be authorised The Program-Master must first be authorised for the locking device on which it is to be used Procedure: 1. Hold the Program-Master for ca 1 second in the reading field of the locking device to start the “authorise mode. The following signal appears: 1x short green and 1x short beep 2. Now you can authorise any number of locking media one after the other by holding each locking media for ca 1 second in the reading field of the locking device. The following signal appears for each locking media: 1x short green and 1x short beep Signalling of OMEGA FLEX Locking devices Page 15 of 39 2   Signalling while using the master media

3. Hold the Program-Master for ca 1 second in the reading field of the locking device to end

the “authorise mode. The following signal appears: 1x long green and 1x long beep The “authorise mode” will end automatically after 5 seconds. Die new authorisations remain stored. All locking media, which were held in the reading field, are now authorised to open this locking device. A locking media can be deleted from a locking device only with the same Program-Master with which it was authorised. Troubleshooting: Signalling Reason Solution During step 1: The program-Master could be read but is not authorised for this locking device. Authorise the Program-Master. Note that you cannot authorise any Program-Master for the V- NET devices. During step 2: a) The locking media was already authorised with another Program-Master or via the OMEGA Client software. b) Instead of a locking media, a master media was held in the reading field. a) Locking media can only be authorised with a Program-Master or via the software. b) Use a locking media. Page 16 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2.6 Deleting locking media authorisations

A locking media can be deleted from a locking device only with the same Program-Master with which it was authorised. Required media: l Program-Master with which the locking media was authorised l Authorised locking media, whose authorisation is to be deleted. Procedure: 1. Hold the Program-Master for ca 1 second in the reading field of the locking device to start the “delete locking media” mode. The following signal appears: 1x short green and 1x short beep 2. Now you can delete any number of locking media one after the other by holding each locking media for ca 2 second in front of the reading field of the locking device. The following signal appears for each locking media: 2x short green and 2x short beep Signalling of OMEGA FLEX Locking devices Page 17 of 39 2   Signalling while using the master media

3. Hold the Program-Master for ca 1 second in the reading field of the locking device to end

the “delete locking media” mode The following signal appears: 1x long green and 1x long beep The “delete locking media mode” will end automatically after 5 seconds. The locking media which were previously held before the locking device will thereby be deleted from the locking device. All locking media, which were held in the reading field, are now no more authorised to open this locking device. Troubleshooting: Signalling Reason Solution During step 1: The program-Master was not yet author ised for this locking device. Authorise the Program-Master. During step 2: The locking media was not authorised with the Program-Master used Use Program-Master with which the lock ing media was authorised The locking media was held for too short a period in the reading field of the locking device. The authorisation was not deleted. Hold the locking media longer in the read ing field of the locking device. Page 18 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2.7 Deleting all locking media authorisations simultaneously

Only those locking media authorisations are deleted, which were added by the same Program-Master, which is also used for deletion. Procedure: 1. Hold the Program-Master before the reading field of the locking device. After ca. 5 second, the following signal appears: 2x short green and 2x short beep 1. Remove the Program-Master from the reading field of the locking device. All locking media authorisations from this locking device are now deleted, which were added with this Program-Master. Signalling of OMEGA FLEX Locking devices Page 19 of 39 2   Signalling while using the master media

2.8 Setting opening period

The opening duration is the length of time during which the locking device remains coupled, after an authorised locking media was held in the reading field of the locking device. The longer the opening duration, the more time people have to operate the locking device after the authenticating with a locking media. The maximum opening duration is 180 seconds. Required master media: l Time-Master The Program-Master must first be authorised for the locking device on which it is to be used Procedure: 1. Hold the Time-Master before the reading field of the locking device. The locking device starts to transmit flashing signals. Each flashing signal represents 1 second opening period. 2. Hold the Time-Master before the locking device until the desired opening period is reached. If, for example, you desire an opening period of 20 seconds, wait for 20 flash signals 3. Remove the Time-Master from the reading field. A signal confirming the setting follows: 1x long green and 1x long beep The opening period is now set The minimum opening period is 2 seconds. If you remove the Time-Master after 1 second from the reading field, the opening period will be set to 2 seconds. The maximum opening duration is 180 seconds. Even if you hold the Time-Master longer in the reading field, the opening period will be set to 180 seconds. Page 20 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2.9 Activating release mode

A locking device which is in release mode remains permanently coupled, i.e. the door can be opened permanently without necessitating the use of any locking media. Required master media: l Release-Master The Program-Master must first be authorised for the locking device on which it is to be used Procedure: 1. Hold the Release-Master before the reading field of the locking device. After ca. 1 second, the following signal appears: 1x short green and 1x short beep If the locking device already lights up green while the Release-Master is being read, but no green flashing signal appears after one second, release mode is already active. 2. Remove the Release-Master from the reading field of the locking device. The release mode is now active. Permanent access without locking media is now possible because the coupling of the locking device is permanently engaged. The release mode has no time limit. Altered signalling in release mode: In release mode, the locking device signals 1x long green (instead of 1x short green) after reading from an authorised locking media. Troubleshooting: Signalling Reason Solution A higher-priority opening mode is currently active b) Deactivate the opening mode with the higher priority. The Release-Master is not authorised. Authorise the Release-Master. Signalling of OMEGA FLEX Locking devices Page 21 of 39 2   Signalling while using the master media

2.10 Deactivating release mode

Required master media: l Release-Master The Program-Master must first be authorised for the locking device on which it is to be used Procedure: 1. Hold the Release-Master before the reading field of the locking device. After ca. 2 second, the following signal appears: 2x short green and 2x short beep The release mode is now deactivated. To gain access, authorised locking media must now again be held before the locking device. Troubleshooting: Signalling Reason Solution A higher-priority opening mode is cur rently active Deactivate the opening mode with higher priority. The Release-Master is not authorised. Authorise the Release-Master Page 22 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2.11 Activating block mode

A locking device in block mode remains permanently uncoupled, i.e. the door cannot be opened. An access even with an authorised locking media is no more possible. Required master media: l Block-Master The Program-Master must first be authorised for the locking device on which it is to be used Procedure: 1. Hold the Block-Master before the reading field of the locking device. After ca. 1 second, the following signal appears: 1x short green and 1x short beep If the locking device already lights up green while the Block-Master is being read, but no green flashing signal appears after one second, block mode is already active. 2. Remove the Block-Master from the reading field of the locking device. The block mode is now active. An access is not possible now even with an authorised locking media because the coupling of the locking devise is permanently disengaged. The block mode has no time limit. Using an Emergency-Key, a locking device can still be opened in block mode. Troubleshooting: Signalling Reason Solution A higher-priority opening mode is cur rently active b) Deactivate the opening mode with the higher priority. The Block-Master is not authorised. Authorise the Block-Master Signalling of OMEGA FLEX Locking devices Page 23 of 39 2   Signalling while using the master media

2.12 Deactivating block mode

Required master media: l Block-Master The Program-Master must first be authorised for the locking device on which it is to be used Procedure: 1. Hold the Block-Master before the reading field of the locking device. After ca. 2 second, the following signal appears: 2x short green and 2x short beep 2. Remove the Block-Master from the reading field of the locking device. The blocking mode is now deactivated. An access with an authorised locking media is now possible again. Troubleshooting: Signalling Reason Solution A higher-priority opening mode is cur rently active Deactivate the opening mode with higher priority. The Block-Master is not authorised. Authorise the Block-Master Page 24 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2.13 Activating emergency mode

Required master media: l Emergency-Key The Emergency-Key must first be authorised for the locking device with which it is to be used Procedure: 1. Hold the locking media before the reading field of the locking device. After ca. 1 second, the following signal appears: 1x short green and 1x short beep If the locking device already lights up green while the Emergency-Key is being read, but no green flashing signal appears after one second, emergency mode is already active. 2. Remove the Emergency-Key from the reading field of the locking device. The locking device is now in emergency mode. Permanent access without locking media is now possible because the coupling of the locking device is permanently engaged. The emergency mode can be deactivated by Emergency-Key only. Troubleshooting: Signalling Reason Solution The Emergency-Key could be read but is not authorised for this locking device. Authorise the Emergency-Key. Signalling of OMEGA FLEX Locking devices Page 25 of 39 2   Signalling while using the master media

2.14 Deactivating emergency mode

Required master media: l Emergency-Key The Emergency-Key must first be authorised for the locking device with which it is to be used Procedure: 1. Hold the locking media before the reading field of the locking device that is in emergency mode. After ca. 2 second, the following signal appears: 2x short green and 2x short beep 2. Remove the Emergency-Key from the reading field of the locking device. The emergency mode is now deactivated. To gain access, authorised locking media must now again be held before the locking device. Troubleshooting: Signalling Reason Solution The Emergency-Key could be read but is not authorised for this locking device. Authorise the Emergency-Key. Page 26 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2.15 Activating online mode

Required master media: l RF-Ini-Master For the activation of online mode it is not necessary to authorise the RF-Ini-Master in advance. Procedure: 1. Hold the RF-Ini-Master for ca 1 second in the reading field of the locking device. Following signals appear: A: 1x short green and 1x short beep = successfully connected to the Access-Point B: 1x long red and 1x long beep = no connection to the Access-Point possible C: 1x long green and 1x long beep = Connection to the Access-Point existed already 2. Remove the RF-Ini-Master from the reading field. The online mode is now deactivated. Even if no connection to the Access-Point was possible, the locking device is now in online mode. Once an Access-Point is found, it will connect itself automatically. Signalling of OMEGA FLEX Locking devices Page 27 of 39 2   Signalling while using the master media

While the RF-Ini-Master is held in the reading field:

The locking device does not belong to the variant NET or VA . The online mode is not available for this locking device. Page 28 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2.16 Deactivating online mode

Required master media: l RF-Ini-Master For the deactivation of the online mode it is not necessary to authorise the RF-Ini-Master in advance. Procedure: 1. Halten Sie den RF-Ini-Master ca. zwei Sekunden lang vor das Lesefeld des Schließgeräts. The following signal appears: 2x short green and 2x short beep 2. Remove the RF-Ini-Master from the reading field. The online mode is now deactivated. Signalling of OMEGA FLEX Locking devices Page 29 of 39 2   Signalling while using the master media

2.17 Checking quality of wireless connection

Required master media: l RF-Trace-Master The RF-Trace-Master is ready for immediate use and does not have to authorised first. Procedure: 1. Hold the RF-Ini-Master for ca 1 second in the reading field of the locking device. The following signal appears: 1x short green and 1x short beep Page 30 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

2. The locking device shows now the quality of the wireless connection:

Very good sufficient weak No wireless connection The Access-Point associated with the Update-Terminal shows during wireless connection test the quality of the wireless connection with the same signalling as the locking device. 3. Hold the RF-Trace-Master ca 1 second in the reading field to end the wireless connection quality display. The following signal appears: 1x long green and 1x long beep The testing of the wireless connection quality is finished herewith. After 3 minutes, the wireless connection quality display will end automatically. Troubleshooting: Signalling Reason Solution The locking device does not belong to the variant NET or VA . Der RF-Trace-Master kann nur an NET- und VA-Geräte verwendet werden. Signalling of OMEGA FLEX Locking devices Page 31 of 39 2   Signalling while using the master media

2.18 Transmitting programming jobs with an RF-Stick to a locking

device Required master media and administration devices: l RF-Stick-Master l RF-Stick l PC with OMEGA Client installed Procedure for creating programming jobs: 1. Start the OMEGA Client and log in with your user name and password. 2. Set the desired changes in the OMEGA Client. 3. Start your changes accordingly as a change programming or new programming, e.g. through PROGRAMMING > PROGRAM ALL CHANGES. The status display of the OMEGA Client shows now "programming required". The individual programming jobs are shown under “Programming status”. Procedure for transmitting programming jobs via an RF-Stick: Page 32 of 39 Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

1. Proceed with your PC and the RF-Stick connected to it to the locking device into which the

programming jobs are to be transmitted. If you want to transmit the programming jobs into multiple locking devices, you can freely choose the sequence in which you look for the locking devices. 2. Hold the RF-Stick-Master briefly in the reading field of the locking device. The following signal appears: 1x short green and 1x short beep 3. The locking device searches now for an RF-Stick nearby. The distance between the locking device and the RF-Stick may not exceed ten meters.at the maximum. As soon as the RF-Stick has been detected, the transmission begins. During transmission, the locking device flashes green. During transmission the following happens: - All programming jobs for this locking device are transmitted to this locking device. During programming, the programming status display shows the progress in percentage. - All events stored in the locking device, which were not available to the OMEGA Client yet, will be copied into the OMEGA Client. - The clock is set. If no programming jobs are available, only the events are copied and the clock is set. In this case, the locking device does not flash during the transmission. After all data has been transmitted, the RF-Stick and the locking device are disconnected automatically. After transmission completion, the programming job is deleted from the “Programming status” list. The programming job transmission is completed when the locking device signals 1x long green and 1x long beep. Troubleshooting: Signalling Reason Solution During step 2: The locking device cannot detect any RF- Stick nearby. Move with a properly connected RF-Stick closer to the locking device and try to transmit the programming jobs once Signalling of OMEGA FLEX Locking devices Page 33 of 39 2   Signalling while using the master media

Page 34 of 39

Signalling of OMEGA FLEX Locking devices 2   Signalling while using the master media

3 Signalling after battery insertion

Signalling Meaning Start sequence for offline locking devices: No error Start sequence for online locking devices: Device is online and is connected to the Access-Point Start sequence for online locking devices: Device is online but no connection to Access-Point is possible Firmware error. Execute a firmware update. If the problem persists, contact your CES partner. In case a system error exists, it will be displayed immediately after the start sequence, see "System error" on page 38. Signalling of OMEGA FLEX Locking devices Page 35 of 39 3   Signalling after battery insertion

4 Battery warning system

When the battery power becomes weak, the locking device displays additional signals if l authorised or unauthorised locking media were held in the reading field of the locking device or l the locking device couples, e.g. after the release or emergency mode was activated. These additional signals are the battery warnings. CAUTION Lockout possible! If the battery is empty, the door cannot be opened any more. - Therefore, replace the battery immediately at warning level 1! Warning level Signalling the battery alarm Reason Required action 1 Battery capacity low Replace the battery 2 Battery capacity is nearly exhausted A device failure is possible now! Replace the battery imme diately 3 Battery is empty A device failure is possible now at anytime! Replace the battery imme diately Page 36 of 39 Signalling of OMEGA FLEX Locking devices 4   Battery warning system

5 Error signalling

Signalling Reason Solution After reading a master media: Master media error: a) The master media is not authorised. a) Authorise the master media. b) For master media, which control the opening modes: An opening mode with higher priority is active. b) Deactivate the opening mode with the higher priority. c) The master media cannot be read because of the locking device variant (e.g. Program-Master for V-NET devices). c) Check whether the master media can be used with the concerned device types. After reading a master media or locking media: 1 The media is not authorised for this device. or 1. Authorise the media for this device or 2. The media could not be read completely because: a) it was not held long enough in the reading field . 2a) Keep the media for a longer period in the reading field of the locking device. b) The master media or the V-NET locking media has wrong system Identification code. 2b) Use a master media or V-NET locking media with the right system identification code. c) a LINE locking media was held in the reading field of a V-NET device. 2c)LINE locking media could not be read by V-NET devices. Additionally after reading the authorised or unauthorised locking media: or or The battery alarm indicates that the batteries are going to be empty soon. Replace the batteries. Signalling of OMEGA FLEX Locking devices Page 37 of 39 5   Error signalling

If system errors are present, they are signalled after to the following actions:

l after reading the authorised locking media l after attempting to put handle set in release mode or emergency mode l after the start sequence (insertion/connecting the batteries) Signalling Reason Solution System error: The actuator of the locking device is malfunctioning. Check if the actuator has jammed. Check the wiring and contacts. If you cannot fix the error by yourself, contact your CES partner. Page 38 of 39 Signalling of OMEGA FLEX Locking devices 5   Error signalling

C. Ed. Schulte GmbH

Zylinderschlossfabrik Friedrichstraße 243 D-42551 Velbert +49 2051 204 0 +49 2051 204 229 [email protected] United Kingdom CES Security Solutions Ltd. Unit 4 Kendon Business Park Maritime Close, Medway City Estate Rochester, Kent ME2 4JF +44 1 634713369 +44 1 634786833 [email protected] CESnederland B.V. Lage Brink 9 NL-7317 BD Apeldoorn +31 55-52 66 89 0 +31 55-52 66 89 9 [email protected] Middle East A.G.P Advanced German Products LLC PO Box 102761 UAE Dubai +971 4 885 7050 +971 4 369 7051 +971 4 390 8935 [email protected] CESfrance SARL 8 Impasse Charles Petit F-75011 Paris +33 1 44 87 07 56 +33 1 43 07 35 78 [email protected] Austria César A. Cárcamo Büro: Wiener Bundesstrasse 33 A-4050 Traun +43 660-73 20 311 +43 732-21 00 22 2681 [email protected] CESitalia srl V. d. vecchie Fondamenta, 4 Straße d. A. Gründungen 4 I-39044 Egna / Neumarkt (BZ) +39 0471 812 294 +39 0471 812 294 [email protected] Belgium Locking Systems Guy Lambrechts Van Haeftenlaan 10 BE-2950 Kapellen +32 497 946267 [email protected] CESrom srl. Str. Metalurgistilor 3 D RO-550137 Sibiu +40 269-206 00 2 +40 269-206 00 5 [email protected] Spain Benidorm Locks S.L. Av. Marina Baixa s / n Partida Torrent ES-03530 La Nucia, Alicante +34 96 689 79 79 +34 96 689 79 78 [email protected] www.ces.eu