Signalling of the locking devices
Electronic handle sets
Electronic cylinder
English
Version VB
1 Signalling during operation
3
1.1 Opening the locking device with a locking medium
3
1.2 Activating the office mode
4
1.3 Deactivating the office mode
5
2 Signalling while using the master media
7
2.1 Authorising System-Master
8
2.2 Authorising additional master media
10
2.3 Deleting master media
12
2.4 Deleting System-Master
14
2.5 Authorising locking media
15
2.6 Deleting locking media authorisations
17
2.7 Deleting all locking media authorisations simultaneously
19
2.8 Setting opening period
20
2.9 Activating release mode
21
2.10 Deactivating release mode
22
2.11 Activating block mode
23
2.12 Deactivating block mode
24
2.13 Activating emergency mode
25
2.14 Deactivating emergency mode
26
2.15 Activating online mode
27
2.16 Deactivating online mode
29
2.17 Checking quality of wireless connection
30
2.18 Transmitting programming jobs with an RF-Stick to a locking device
32
3 Signalling after battery insertion
35
4 Battery warning system
36
5 Error signalling
37
Page 2 of 39
Signalling of OMEGA FLEX Locking devices
1 Signalling during operation
1.1 Opening the locking device with a locking medium
Procedure:
1. Hold an authorised locking media for ca. 1 second in the reading field of the locking device
(maximum distance ca. 10 mm).
The following signal appears:
1x short green and 1x short beep
You can open the door by pressing the lever handle for a certain period. The length of the time
period depends upon the opening period set.
During the opening period no further locking media or master media are read. Only after
you hear that the coupling of locking device has disengaged, you can hold another locking
media in the reading field of the locking device.
Troubleshooting:
Signalling
Reason
Solution
The locking
media cannot be
read (No signal).
The locking media was not held close
enough to the reading field of the locking
device.
Hold the locking media longer in the
reading field of the locking device.
The reading field is shielded by metallic
materials.
Remove the metallic materials from the
reading field of the locking device.
Shortly before, another authorised locking
media was held in the reading field of
the locking device and the opening
period of the locking device has not yet
expired.
You can open the door without having to
have your locking media read.
The battery is empty.
Replace the batteries
b) The locking media is defective.
Have a new locking media issued by the
administrator of the OMEGA FLEX system.
Signalling of OMEGA FLEX Locking devices
Page 3 of 39
1 Signalling during operation
The locking media is not authorised.
Have the locking media authorised by the
administrator of the OMEGA FLEX system.
The locking media is authorised but the
block time or block mode is active.
If the block time or block mode is active, a
locking device cannot be opened by an
authorised locking media.
The locking media is authorised and the
locking device is currently in release
mode.
You can open the door also without an
authorised locking media.
1.2 Activating the office mode
Required devices and locking media:
l Locking media, which is authorised for the office function
l Locking device, which is authorised for the office function
Procedure:
1. Hold the locking media authorised for the office function for ca 2 seconds in the reading
field of the locking device.
As soon as the locking media is in the reading field, the following signal appears:
1x short green and 1x short beep
After ca 2 second, another signal appears:
1x short green and 1x short beep, 1x long green and 1x long beep
The office mode is now active. The door can now be opened until the end of the office hours
without locking media. LINE locking device reconnects automatically at the end-time set in the
OMEGA Client.
Since there are no start and end-times for the Office function in the V-NET, there is no
end-time at which the locking device automatically reconnects. Therefore, the office mode
in V-NET must be deactivated with an authorised locking media.
Page 4 of 39
Signalling of OMEGA FLEX Locking devices
1 Signalling during operation
No signal after ca 2 seconds. The
office mode is not active. The
coupling of the locking device
engages, but disengages again
after expiry of the opening
duration.
The locking device is not authorised
for the office function.
Have the locking device
authorised for the office function
by the system administrator.
The office function is not available at
this time.
Enquire with the system
administrator, when the office
function in this locking device can
be activated.
The locking media is not authorised
for the office function.
Have the locking media
authorised for the office function
by the system administrator.
1.3 Deactivating the office mode
Required devices and locking media:
l Locking media, which is authorised for the office function
l Locking device, which is authorised for the office function
Procedure:
1. Hold the locking media authorised for the office function for ca 2 seconds in the reading
field of the locking device.
As soon as the locking media is in the reading field, the following signal appears:
1x long green and 1x long beep
After ca 2 second, another signal appears:
1x long green and 1x long beep, 1x short green and 1x short beep
The office mode is now deactivated. The door can be opened now only with authorised locking
media.
Troubleshooting:
Signalling
Reason
Solution
After 2 seconds
The office mode cannot be deactivated
Have your locking media authorised for
Signalling of OMEGA FLEX Locking devices
Page 5 of 39
1 Signalling during operation
because the locking media is not
authorised for the office function.
the office function by the system
administrator.
Page 6 of 39
Signalling of OMEGA FLEX Locking devices
1 Signalling during operation
2 Signalling while using the master media
2.1
Authorising System-Master
8
2.2
Authorising additional master media
10
2.3
Deleting master media
12
2.4
Deleting System-Master
14
2.5
Authorising locking media
15
2.6
Deleting locking media authorisations
17
2.7
Deleting all locking media authorisations simultaneously
19
2.8
Setting opening period
20
2.9
Activating release mode
21
2.10
Deactivating release mode
22
2.11
Activating block mode
23
2.12
Deactivating block mode
24
2.13
Activating emergency mode
25
2.14
Deactivating emergency mode
26
2.15
Activating online mode
27
2.16
Deactivating online mode
29
2.17
Checking quality of wireless connection
30
2.18
Transmitting programming jobs with an RF-Stick to a locking device
32
Signalling of OMEGA FLEX Locking devices
Page 7 of 39
2 Signalling while using the master media
2.1 Authorising System-Master
Each locking device of an OMEGAFLEX system must first become familiar with the System -
Master of the system so that the System-Master is authorised to authorise additional master
media for this locking device.
Each OMEGA FLEX system has only one System-Master. Through the system identification code
which is stored in the locking device and in the System-Master, it is ensured that only the System-
Master belonging to a given system can be authorised for the locking devices of that system.
For security reasons, you should authorise the System-Master on all locking devices.
If you are using the OMEGA Suite: Ensure that the System-Master has been read into the
OMEGA Client. As a result, it is automatically authorised for the locking device during the
initial reprogramming of the locking device.
Required master media:
l System-Master
Procedure:
1. Hold the System-Master for ca 1 second in the reading field of the locking device and then
remove it from the reading field.
The following signal appears:
1x short green and 1x short beep
Page 8 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2. Hold the System-Master again for ca 1 second in the reading field of the locking device and
then remove it from the reading field.
The following signal appears:
1x long green and 1x long beep
The System-Master is now authorised for this locking device.
Troubleshooting:
Signalling
Reason
Solution
During step 1:
The System-Master does not have the cor
rect system identification code.
Use the System-Master with correct sys
tem identification code.
During step 2:
Another System-Master has already been
authorised for this locking device.
Since, at any given time only one
System-Master exists which can
be authorised on the basis of
individual system identification
code for a locking device, there is
reason to suspect manipulation.
Contact your CES partner
immediately!
Signalling of OMEGA FLEX Locking devices
Page 9 of 39
2 Signalling while using the master media
2.2 Authorising additional master media
All master media must be authorised prior to their first use. The only exceptions are the RF-Ini-
Master (in NET and VA devices) and the RF-Trace-Master.
Required master media:
l System-Master
l Any master media that needs to be authorised
Procedure:
1. Hold the System-Master for ca 1 second in the reading field of the locking device to start
the “authorise mode” of the locking device.
The following signal appears:
1x short green and 1x short beep
2. Now you can authorise any number of master media one after the other by holding each
master media for ca 1 second in the reading field of the locking device.
The following signal appears for each master media:
1x short green and 1x short beep
Page 10 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
3. Hold the System-Master for ca 1 second in the reading field of the locking device to end the
“authorise mode.
The following signal appears:
1x long green and 1x long beep
The “authorise mode” will end automatically after 5 seconds. Die new authorisations
remain stored.
All master media, which were held before reading field, are now authorised to make settings for
this locking device.
Troubleshooting:
Signalling
Reason
Solution
During step 2:
The master media could be read but
could not be authorised:
a) You have tried to authorise a
Program-Master for a V-NET locking
device.
a) Program-Master cannot be authorised
for V-NET devices.
b) The master media has the wrong
system identity code
b) Use a master media with the correct
system identification code.
c) You have used a locking media
instead of a master-media.
c) Use a master media.
d) you have tried to authorise an RF-
Trace-Master or an RF-Ini-Master.
d) RF-Trace-Master and RF-Ini-Master
cannot be authorised.
Signalling of OMEGA FLEX Locking devices
Page 11 of 39
2 Signalling while using the master media
2.3 Deleting master media
The deletion of a Program-Master deletes all locking authorisations which were assigned
with this Program-Master.
The opening duration set with theTime-Master remains intact even after deletion of the
Time-Master.
Required master media:
l System-Master
l Any master media, that needs to be deleted
Procedure:
1. Hold the System-Master for ca1 second in the reading field of the locking device to start
the “delete master media” mode of the locking device.
The following signal appears:
1x short green and 1x short beep
Page 12 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2. Now you can delete any number of master media one after the other by holding each
master media for ca 5 second in the reading field of the locking device.
The following signal appears for each master media:
2x short green and 2x short beep
3. Hold the System-Master for ca 1 second in the reading field of the locking device to end the
“delete master media” mode.
The following signal appears:
1x long green and 1x long beep
The “delete master media mode” will end automatically after ca 5 seconds. The master
media which were previously held before the locking device will be deleted.
All master media, which were held in the reading field, are now no longer authorised to make
settings for this locking device.
Troubleshooting:
Signalling
Reason
Solution
During step 2:
The master media cannot be deleted
because it does not belong to the master
media, which mist be authorised.
The RF-Ini-Master (for NET and VA
devices) and the RF-Trace-Master do not
have to be authorised and therefore can
not be deleted.
The master media was held too short in
the reading field of the locking device.
The authorisation was not deleted.
Keep the master media longer in the read
ing field of the locking device.
Signalling of OMEGA FLEX Locking devices
Page 13 of 39
2 Signalling while using the master media
2.4 Deleting System-Master
Effects of deletion of System-Master
l Deletion of the System-Master results in deletion of all master media and locking author
isations from a locking device.
l All settings in the locking device, which were made with the OMEGA Client software (e.g.
Time profiles, locking media authorisations etc.), remain intact after deletion of the Sys
tem-Master.
l Deletion of the System-Master deactivates all active opening modes of a locking device.
Online devices remain in online mode though.
l The opening period set with the Time-Master remains intact after deletion of the Time-
Master.
Required master media:
l System-Master
Procedure:
1. Hold the System-Master for ca. 5 seconds in the reading field of the locking device.
The following signal appears:
2x short green and 2x short beep
2. Remove the System-Master from the reading field of the locking device.
It is automatically ensured that no access is possible in that if the coupling of the locking device
was engaged, disengages.
The System-Master is now deleted from this locking device.
Page 14 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2.5 Authorising locking media
Required media:
l Program-Master
l Any locking media that needs to be authorised
The Program-Master must first be authorised for the locking device on which it is to be
used
Procedure:
1. Hold the Program-Master for ca 1 second in the reading field of the locking device to start
the “authorise mode.
The following signal appears:
1x short green and 1x short beep
2. Now you can authorise any number of locking media one after the other by holding each
locking media for ca 1 second in the reading field of the locking device.
The following signal appears for each locking media:
1x short green and 1x short beep
Signalling of OMEGA FLEX Locking devices
Page 15 of 39
2 Signalling while using the master media
3. Hold the Program-Master for ca 1 second in the reading field of the locking device to end
the “authorise mode.
The following signal appears:
1x long green and 1x long beep
The “authorise mode” will end automatically after 5 seconds. Die new authorisations
remain stored.
All locking media, which were held in the reading field, are now authorised to open this locking
device.
A locking media can be deleted from a locking device only with the same Program-Master
with which it was authorised.
Troubleshooting:
Signalling
Reason
Solution
During step 1:
The program-Master could be read but is
not authorised for this locking device.
Authorise the Program-Master.
Note that you cannot authorise
any Program-Master for the V-
NET devices.
During step 2:
a) The locking media was already
authorised with another Program-Master
or via the OMEGA Client software.
b) Instead of a locking media, a master
media was held in the reading field.
a) Locking media can only be authorised
with a Program-Master or via the
software.
b) Use a locking media.
Page 16 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2.6 Deleting locking media authorisations
A locking media can be deleted from a locking device only with the same Program-Master
with which it was authorised.
Required media:
l Program-Master with which the locking media was authorised
l Authorised locking media, whose authorisation is to be deleted.
Procedure:
1. Hold the Program-Master for ca 1 second in the reading field of the locking device to start
the “delete locking media” mode.
The following signal appears:
1x short green and 1x short beep
2. Now you can delete any number of locking media one after the other by holding each
locking media for ca 2 second in front of the reading field of the locking device.
The following signal appears for each locking media:
2x short green and 2x short beep
Signalling of OMEGA FLEX Locking devices
Page 17 of 39
2 Signalling while using the master media
3. Hold the Program-Master for ca 1 second in the reading field of the locking device to end
the “delete locking media” mode
The following signal appears:
1x long green and 1x long beep
The “delete locking media mode” will end automatically after 5 seconds. The locking media
which were previously held before the locking device will thereby be deleted from the
locking device.
All locking media, which were held in the reading field, are now no more authorised to open this
locking device.
Troubleshooting:
Signalling
Reason
Solution
During step 1:
The program-Master was not yet author
ised for this locking device.
Authorise the Program-Master.
During step 2:
The locking media was not authorised
with the Program-Master used
Use Program-Master with which the lock
ing media was authorised
The locking media was held for too short
a period in the reading field of the locking
device. The authorisation was not deleted.
Hold the locking media longer in the read
ing field of the locking device.
Page 18 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2.7 Deleting all locking media authorisations simultaneously
Only those locking media authorisations are deleted, which were added by the same
Program-Master, which is also used for deletion.
Procedure:
1. Hold the Program-Master before the reading field of the locking device.
After ca. 5 second, the following signal appears:
2x short green and 2x short beep
1. Remove the Program-Master from the reading field of the locking device.
All locking media authorisations from this locking device are now deleted, which were added with
this Program-Master.
Signalling of OMEGA FLEX Locking devices
Page 19 of 39
2 Signalling while using the master media
2.8 Setting opening period
The opening duration is the length of time during which the locking device remains coupled, after
an authorised locking media was held in the reading field of the locking device.
The longer the opening duration, the more time people have to operate the locking device after
the authenticating with a locking media. The maximum opening duration is 180 seconds.
Required master media:
l Time-Master
The Program-Master must first be authorised for the locking device on which it is to be
used
Procedure:
1. Hold the Time-Master before the reading field of the locking device.
The locking device starts to transmit flashing signals. Each flashing signal represents 1 second
opening period.
2. Hold the Time-Master before the locking device until the desired opening period is
reached. If, for example, you desire an opening period of 20 seconds, wait for 20 flash
signals
3. Remove the Time-Master from the reading field.
A signal confirming the setting follows:
1x long green and 1x long beep
The opening period is now set
The minimum opening period is 2 seconds. If you remove the Time-Master after 1 second
from the reading field, the opening period will be set to 2 seconds.
The maximum opening duration is 180 seconds. Even if you hold the Time-Master longer in
the reading field, the opening period will be set to 180 seconds.
Page 20 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2.9 Activating release mode
A locking device which is in release mode remains permanently coupled, i.e. the door can be
opened permanently without necessitating the use of any locking media.
Required master media:
l Release-Master
The Program-Master must first be authorised for the locking device on which it is to be
used
Procedure:
1. Hold the Release-Master before the reading field of the locking device.
After ca. 1 second, the following signal appears:
1x short green and 1x short beep
If the locking device already lights up green while the Release-Master is being read, but no
green flashing signal appears after one second, release mode is already active.
2. Remove the Release-Master from the reading field of the locking device.
The release mode is now active. Permanent access without locking media is now possible because
the coupling of the locking device is permanently engaged. The release mode has no time limit.
Altered signalling in release mode: In release mode, the locking device signals 1x long
green (instead of 1x short green) after reading from an authorised locking media.
Troubleshooting:
Signalling
Reason
Solution
A higher-priority opening mode is currently
active
b) Deactivate the opening mode with the
higher priority.
The Release-Master is not authorised.
Authorise the Release-Master.
Signalling of OMEGA FLEX Locking devices
Page 21 of 39
2 Signalling while using the master media
2.10 Deactivating release mode
Required master media:
l Release-Master
The Program-Master must first be authorised for the locking device on which it is to be
used
Procedure:
1. Hold the Release-Master before the reading field of the locking device.
After ca. 2 second, the following signal appears:
2x short green and 2x short beep
The release mode is now deactivated. To gain access, authorised locking media must now again be
held before the locking device.
Troubleshooting:
Signalling
Reason
Solution
A higher-priority opening mode is cur
rently active
Deactivate the
opening mode with higher priority.
The Release-Master is not authorised.
Authorise the
Release-Master
Page 22 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2.11 Activating block mode
A locking device in block mode remains permanently uncoupled, i.e. the door cannot be opened.
An access even with an authorised locking media is no more possible.
Required master media:
l Block-Master
The Program-Master must first be authorised for the locking device on which it is to be
used
Procedure:
1. Hold the Block-Master before the reading field of the locking device.
After ca. 1 second, the following signal appears:
1x short green and 1x short beep
If the locking device already lights up green while the Block-Master is being read, but no
green flashing signal appears after one second, block mode is already active.
2. Remove the Block-Master from the reading field of the locking device.
The block mode is now active. An access is not possible now even with an authorised locking media
because the coupling of the locking devise is permanently disengaged. The block mode has no time
limit.
Using an Emergency-Key, a locking device can still be opened in block mode.
Troubleshooting:
Signalling
Reason
Solution
A higher-priority opening mode is cur
rently active
b) Deactivate the opening mode with the
higher priority.
The Block-Master is not authorised.
Authorise the
Block-Master
Signalling of OMEGA FLEX Locking devices
Page 23 of 39
2 Signalling while using the master media
2.12 Deactivating block mode
Required master media:
l Block-Master
The Program-Master must first be authorised for the locking device on which it is to be
used
Procedure:
1. Hold the Block-Master before the reading field of the locking device.
After ca. 2 second, the following signal appears:
2x short green and 2x short beep
2. Remove the Block-Master from the reading field of the locking device.
The blocking mode is now deactivated. An access with an authorised locking media is now possible
again.
Troubleshooting:
Signalling
Reason
Solution
A higher-priority opening mode is cur
rently active
Deactivate the
opening mode with higher priority.
The Block-Master is not authorised.
Authorise the
Block-Master
Page 24 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2.13 Activating emergency mode
Required master media:
l Emergency-Key
The Emergency-Key must first be authorised for the locking device with which it is to be
used
Procedure:
1. Hold the locking media before the reading field of the locking device.
After ca. 1 second, the following signal appears:
1x short green and 1x short beep
If the locking device already lights up green while the Emergency-Key is being read, but no
green flashing signal appears after one second, emergency mode is already active.
2. Remove the Emergency-Key from the reading field of the locking device.
The locking device is now in emergency mode. Permanent access without locking media is now
possible because the coupling of the locking device is permanently engaged. The emergency mode
can be deactivated by Emergency-Key only.
Troubleshooting:
Signalling
Reason
Solution
The Emergency-Key could be read but is
not authorised for this locking device.
Authorise the Emergency-Key.
Signalling of OMEGA FLEX Locking devices
Page 25 of 39
2 Signalling while using the master media
2.14 Deactivating emergency mode
Required master media:
l Emergency-Key
The Emergency-Key must first be authorised for the locking device with which it is to be
used
Procedure:
1. Hold the locking media before the reading field of the locking device that is in emergency
mode.
After ca. 2 second, the following signal appears:
2x short green and 2x short beep
2. Remove the Emergency-Key from the reading field of the locking device.
The emergency mode is now deactivated. To gain access, authorised locking media must now
again be held before the locking device.
Troubleshooting:
Signalling
Reason
Solution
The Emergency-Key could be read but is
not authorised for this locking device.
Authorise the Emergency-Key.
Page 26 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2.15 Activating online mode
Required master media:
l RF-Ini-Master
For the activation of online mode it is not necessary to authorise the RF-Ini-Master in
advance.
Procedure:
1. Hold the RF-Ini-Master for ca 1 second in the reading field of the locking device.
Following signals appear:
A: 1x short green and 1x short beep
= successfully connected to the Access-Point
B: 1x long red and 1x long beep
= no connection to the Access-Point possible
C: 1x long green and 1x long beep
= Connection to the Access-Point existed already
2. Remove the RF-Ini-Master from the reading field.
The online mode is now deactivated.
Even if no connection to the Access-Point was possible, the locking device is now in online
mode. Once an Access-Point is found, it will connect itself automatically.
Signalling of OMEGA FLEX Locking devices
Page 27 of 39
2 Signalling while using the master media
While the RF-Ini-Master is held in the reading field:
The locking device does not belong to the
variant NET or VA .
The online mode is not available for this
locking device.
Page 28 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2.16 Deactivating online mode
Required master media:
l RF-Ini-Master
For the deactivation of the online mode it is not necessary to authorise the RF-Ini-Master in
advance.
Procedure:
1. Halten Sie den RF-Ini-Master ca. zwei Sekunden lang vor das Lesefeld des Schließgeräts.
The following signal appears:
2x short green and 2x short beep
2. Remove the RF-Ini-Master from the reading field.
The online mode is now deactivated.
Signalling of OMEGA FLEX Locking devices
Page 29 of 39
2 Signalling while using the master media
2.17 Checking quality of wireless connection
Required master media:
l RF-Trace-Master
The RF-Trace-Master is ready for immediate use and does not have to authorised first.
Procedure:
1. Hold the RF-Ini-Master for ca 1 second in the reading field of the locking device.
The following signal appears:
1x short green and 1x short beep
Page 30 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
2. The locking device shows now the quality of the wireless connection:
Very good
sufficient
weak
No wireless connection
The Access-Point associated with the Update-Terminal shows during wireless connection
test the quality of the wireless connection with the same signalling as the locking device.
3. Hold the RF-Trace-Master ca 1 second in the reading field to end the wireless connection
quality display.
The following signal appears:
1x long green and 1x long beep
The testing of the wireless connection quality is finished herewith.
After 3 minutes, the wireless connection quality display will end automatically.
Troubleshooting:
Signalling
Reason
Solution
The locking device does not belong to the
variant NET or VA .
Der RF-Trace-Master kann nur an NET-
und VA-Geräte verwendet werden.
Signalling of OMEGA FLEX Locking devices
Page 31 of 39
2 Signalling while using the master media
2.18 Transmitting programming jobs with an RF-Stick to a locking
device
Required master media and administration devices:
l RF-Stick-Master
l RF-Stick
l PC with OMEGA Client installed
Procedure for creating programming jobs:
1. Start the OMEGA Client and log in with your user name and password.
2. Set the desired changes in the OMEGA Client.
3. Start your changes accordingly as a change programming or new programming, e.g.
through PROGRAMMING > PROGRAM ALL CHANGES.
The status display of the OMEGA Client shows now "programming required". The individual
programming jobs are shown under “Programming status”.
Procedure for transmitting programming jobs via an RF-Stick:
Page 32 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
1. Proceed with your PC and the RF-Stick connected to it to the locking device into which the
programming jobs are to be transmitted.
If you want to transmit the programming jobs into multiple locking devices, you can freely
choose the sequence in which you look for the locking devices.
2. Hold the RF-Stick-Master briefly in the reading field of the locking device.
The following signal appears:
1x short green and 1x short beep
3. The locking device searches now for an RF-Stick nearby.
The distance between the locking device and the RF-Stick may not exceed ten meters.at
the maximum.
As soon as the RF-Stick has been detected, the transmission begins. During transmission, the
locking device flashes green.
During transmission the following happens:
- All programming jobs for this locking device are transmitted to this locking device.
During programming, the programming status display shows the progress in
percentage.
- All events stored in the locking device, which were not available to the OMEGA
Client yet, will be copied into the OMEGA Client.
- The clock is set.
If no programming jobs are available, only the events are copied and the clock
is set. In this case, the locking device does not flash during the transmission.
After all data has been transmitted, the RF-Stick and the locking device are disconnected
automatically. After transmission completion, the programming job is deleted from the
“Programming status” list.
The programming job transmission is completed when the locking device signals 1x long green
and 1x long beep.
Troubleshooting:
Signalling
Reason
Solution
During step 2:
The locking device cannot detect any RF-
Stick nearby.
Move with a properly connected RF-Stick
closer to the locking device and try to
transmit the programming jobs once
Signalling of OMEGA FLEX Locking devices
Page 33 of 39
2 Signalling while using the master media
Page 34 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media
3 Signalling after battery insertion
Signalling
Meaning
Start sequence for offline locking devices: No error
Start sequence for online locking devices: Device is online and is connected to the
Access-Point
Start sequence for online locking devices: Device is online but no connection to
Access-Point is possible
Firmware error. Execute a firmware update. If the problem persists, contact your
CES partner.
In case a system error exists, it will be displayed immediately after the
start sequence, see "System error" on page 38.
Signalling of OMEGA FLEX Locking devices
Page 35 of 39
3 Signalling after battery insertion
4 Battery warning system
When the battery power becomes weak, the locking device displays additional signals if
l authorised or unauthorised locking media were held in the reading field of the locking
device or
l the locking device couples, e.g. after the release or emergency mode was activated.
These additional signals are the battery warnings.
CAUTION
Lockout possible!
If the battery is empty, the door cannot be opened any more.
- Therefore, replace the battery immediately at warning level 1!
Warning
level
Signalling the battery
alarm
Reason
Required action
1
Battery capacity low
Replace the battery
2
Battery capacity is nearly exhausted
A device failure is possible
now!
Replace the battery imme
diately
3
Battery is empty
A device failure is possible
now at anytime!
Replace the battery imme
diately
Page 36 of 39
Signalling of OMEGA FLEX Locking devices
4 Battery warning system
5 Error signalling
Signalling
Reason
Solution
After reading a master media:
Master media error:
a) The master media is not authorised.
a) Authorise the master media.
b) For master media, which control the
opening modes: An opening mode with
higher priority is active.
b) Deactivate the opening mode with
the higher priority.
c) The master media cannot be read
because of the locking device variant (e.g.
Program-Master for V-NET devices).
c) Check whether the master media
can be used with the concerned
device types.
After reading a master media or locking media:
1 The media is not authorised for this
device.
or
1. Authorise the media for this device
or
2. The media could not be read completely
because:
a) it was not held long enough in the
reading field .
2a) Keep the media for a longer
period in the reading field of the
locking device.
b) The master media or the V-NET locking
media has wrong system Identification
code.
2b) Use a master media or V-NET
locking media with the right system
identification code.
c) a LINE locking media was held in the
reading field of a V-NET device.
2c)LINE locking media could not be
read by V-NET devices.
Additionally after reading the authorised or unauthorised locking media:
or
or
The battery alarm indicates that the
batteries are going to be empty soon.
Replace the batteries.
Signalling of OMEGA FLEX Locking devices
Page 37 of 39
5 Error signalling
If system errors are present, they are signalled after to the following actions:
l after reading the authorised locking media
l after attempting to put handle set in release mode or emergency mode
l after the start sequence (insertion/connecting the batteries)
Signalling
Reason
Solution
System error: The actuator of the locking
device is malfunctioning.
Check if the actuator has jammed.
Check the wiring and contacts.
If you cannot fix the error by yourself,
contact your CES partner.
Page 38 of 39
Signalling of OMEGA FLEX Locking devices
5 Error signalling
C. Ed. Schulte GmbH
Zylinderschlossfabrik
Friedrichstraße 243
D-42551 Velbert
+49 2051 204 0
+49 2051 204 229
[email protected]
United Kingdom
CES Security Solutions Ltd.
Unit 4 Kendon Business Park
Maritime Close, Medway City Estate
Rochester, Kent ME2 4JF
+44 1 634713369
+44 1 634786833
[email protected]
CESnederland B.V.
Lage Brink 9
NL-7317 BD Apeldoorn
+31 55-52 66 89 0
+31 55-52 66 89 9
[email protected]
Middle East
A.G.P Advanced German Products LLC
PO Box 102761
UAE Dubai
+971 4 885 7050
+971 4 369 7051
+971 4 390 8935
[email protected]
CESfrance SARL
8 Impasse Charles Petit
F-75011 Paris
+33 1 44 87 07 56
+33 1 43 07 35 78
[email protected]
Austria
César A. Cárcamo
Büro: Wiener Bundesstrasse 33
A-4050 Traun
+43 660-73 20 311
+43 732-21 00 22 2681
[email protected]
CESitalia srl
V. d. vecchie Fondamenta, 4
Straße d. A. Gründungen 4
I-39044 Egna / Neumarkt (BZ)
+39 0471 812 294
+39 0471 812 294
[email protected]
Belgium
Locking Systems
Guy Lambrechts
Van Haeftenlaan 10
BE-2950 Kapellen
+32 497 946267
[email protected]
CESrom srl.
Str. Metalurgistilor 3 D
RO-550137 Sibiu
+40 269-206 00 2
+40 269-206 00 5
[email protected]
Spain
Benidorm Locks S.L.
Av. Marina Baixa s / n
Partida Torrent
ES-03530 La Nucia, Alicante
+34 96 689 79 79
+34 96 689 79 78
[email protected]
www.ces.eu