CDVI FTC1000 Configuration Manual
Text of the manual
1] WIRING (FTC1000)
EN
FTC1000
CONFIGURATION GUIDE
2
cdvi.co.uk
2] First start
Power
12 V DC
Consumption
12 W
IP66
da -25°C a +60°C
RS485 - NOT USED
POWER SUPPLY 12 V DC / 2A
RESET
(Long press reset to factory values)
RJ45 - LAN Connection
RS232 - NOT USED
NO
COM Relay Output - Dry contact *
NC
* Use a support relay to avoid damaging
the device
At the first start, the FTC1000 device shows the IP address acquired in DHCP at the
top right of the display.
If there is no DHCP server, the device will still show an IP address through which it
will be possible to connect for configuration.
IP ADDRESS
Thank you for purchasing this product and for the trust you have in our company.
3] Connection to the FTC1000 via Web Browser
4] Configuration
To configure the device click on CONFIGURATION
Set record stay time :
Not limited (stores all events overwriting the oldest ones, event log 25000)
Set record stay time (life cycle of the stored data, after the set period the event
LOG are deleted from the memory)
Log in
User : admin
Password : 12345
To access the device configuration / query page, type in the address bar of the
internet browser http://IP Address:7080
Ex : IP Address 192.168.1.88
http://192.168.1.88:7080
Click on System--> System Configuration --> Snapshot
Record keeping : enables memorisation of each access
Save picture : enables saving of the snapshot linked to each step
Enable LOG record
Click on Network--> Basic setup
Stranger passage : Allows strangers to access
Detection mask : enables mask control
Relay time : Set relay time
Relay direction : Normal (activates relay for door unlocking)
Reverse (activates relay in case of alarm)
Living body : (don’t modify)
Thermal map : show / hide heat map being recognized
IP Address Configuration
Remove the flag from DHCP and configure the desired network parameters.
Control configuration
Click on Face recognition --> Face recognition
Enabling temperature control
Click on Temperature --> Temperature
Enable temperature control : enables temperature control
Temperature compensation : compensates the temperature detected in hot or cold
environments at controlled temperature.
Alarm temperature : 37.3 - don’t modify
Enable MQTT protocol
Click on Network--> Advance Setup --> MQTT
Enabling the MQTT protocol allows you to
integrate the FTC1000 device into third-
party software.
Enable the protocol and fill in the fields
according to your configurations.
Note: If you use third party software
integration, you will not be able to use the
SDP2000 software.
Enabling mail sending in case of alarm
Click on Network --> Advanced Setup --> SMTP
If enabled in case of alarm (high temperature / lack of faceplate) the terminal sends
an email to the 3 configured addresses.
If Attach file is selected, the snapshot of the detected alarm will be attached.
Fill in the fields according to the configuration of the email account you want to use
as the Sender.
Note: contact your mail provider or carrier to obtain the necessary data.
To view the events click on PICTURE
Set the filters
- By date
- By temperature
Click on the icon with the magnifying glass
List View
Grid View
Click on Download in the top right to download the photos of the selected events.
6] Facial Recognition
To carry out facial recognition, refer to the FTC1000 manual.
FTC-1000 EN - CONFIGURATION GUIDE
All the information contained within this document (pictures, drawing, features, specifications and dimensions) could be perceptibly different and can be changed without prior notice.
Toutes les informations mentionnées à titre indicatif sur le présent document (photos, dessins, caractéristiques techniques et dimensions) peuvent varier et sont susceptibles de
modifications sans notification préalable.
*G0301FR0234V13*
CDVI Group
FRANCE (HQ)
Phone: +33 (0)1 48 91 01 02
Fax: +33 (0)1 48 91 21 21
CDVI SAS
FRANCE & EXPORT
31, av. du Général Leclerc
93500 PANTIN - Francia
Phone: +33 (0)1 48 91 01 02
www.cdvi.com
CDVI AMERICAS
[CANADA - USA]
Phone: +1 (450) 682 7945
www.cdvi.ca
CDVI BENELUX
Phone: +32 (0) 56 73 93 00
www.cdvibenelux.com
CDVI TAIWAN
Phone: +886 (0)42471 2188
www.cdvichina.cn
CDVI SWITZERLAND
Phone: +41 (0)21 882 18 41
www.cdvi.ch
CDVI CHINA
Phone: +86 (0)10 84606132/82
www.cdvichina.cn
CDVI IBERICA
Phone: +34 (0)935 390 966
www.cdviberica.com
CDVI ITALIA
Phone: +39 0321 90 573
Fax: +39 0321 90 8018
www.cdvi.it
CDVI MOROCCO
Phone: +212 (0)5 22 48 09 40
www.cdvi.ma
CDVI SWEDEN
Phone: +46 (0)31 760 19 30
www.cdvi.se
CDVI UK
[UK & IRELAND]
Phone: +44 (0)1628 531300
www.cdvi.co.uk
CDVI POLAND
Phone: +48-12-659 23 44
www.cdvi.com.pl