1] WIRING (FTC1000)

EN FTC1000 CONFIGURATION GUIDE 2 cdvi.co.uk 2] First start Power 12 V DC Consumption 12 W IP66 da -25°C a +60°C RS485 - NOT USED POWER SUPPLY 12 V DC / 2A RESET (Long press reset to factory values) RJ45 - LAN Connection RS232 - NOT USED NO COM Relay Output - Dry contact * NC * Use a support relay to avoid damaging the device At the first start, the FTC1000 device shows the IP address acquired in DHCP at the top right of the display. If there is no DHCP server, the device will still show an IP address through which it will be possible to connect for configuration. IP ADDRESS Thank you for purchasing this product and for the trust you have in our company.

3] Connection to the FTC1000 via Web Browser

4] Configuration To configure the device click on CONFIGURATION Set record stay time : Not limited (stores all events overwriting the oldest ones, event log 25000) Set record stay time (life cycle of the stored data, after the set period the event LOG are deleted from the memory) Log in User : admin Password : 12345 To access the device configuration / query page, type in the address bar of the internet browser http://IP Address:7080 Ex : IP Address 192.168.1.88 http://192.168.1.88:7080 Click on System--> System Configuration --> Snapshot Record keeping : enables memorisation of each access Save picture : enables saving of the snapshot linked to each step Enable LOG record

Click on Network--> Basic setup

Stranger passage : Allows strangers to access Detection mask : enables mask control Relay time : Set relay time Relay direction : Normal (activates relay for door unlocking) Reverse (activates relay in case of alarm) Living body : (don’t modify) Thermal map : show / hide heat map being recognized IP Address Configuration Remove the flag from DHCP and configure the desired network parameters. Control configuration Click on Face recognition --> Face recognition

Enabling temperature control

Click on Temperature --> Temperature Enable temperature control : enables temperature control Temperature compensation : compensates the temperature detected in hot or cold environments at controlled temperature. Alarm temperature : 37.3 - don’t modify Enable MQTT protocol Click on Network--> Advance Setup --> MQTT­­­ Enabling the MQTT protocol allows you to integrate the FTC1000 device into third- party software. Enable the protocol and fill in the fields according to your configurations. Note: If you use third party software integration, you will not be able to use the SDP2000 software.

Enabling mail sending in case of alarm

Click on Network --> Advanced Setup --> SMTP If enabled in case of alarm (high temperature / lack of faceplate) the terminal sends an email to the 3 configured addresses. If Attach file is selected, the snapshot of the detected alarm will be attached. Fill in the fields according to the configuration of the email account you want to use as the Sender. Note: contact your mail provider or carrier to obtain the necessary data.

To view the events click on PICTURE

Set the filters - By date - By temperature Click on the icon with the magnifying glass List View Grid View Click on Download in the top right to download the photos of the selected events. 6] Facial Recognition To carry out facial recognition, refer to the FTC1000 manual.

FTC-1000 EN - CONFIGURATION GUIDE

All the information contained within this document (pictures, drawing, features, specifications and dimensions) could be perceptibly different and can be changed without prior notice. Toutes les informations mentionnées à titre indicatif sur le présent document (photos, dessins, caractéristiques techniques et dimensions) peuvent varier et sont susceptibles de modifications sans notification préalable. *G0301FR0234V13* CDVI Group FRANCE (HQ) Phone: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21 CDVI SAS FRANCE & EXPORT 31, av. du Général Leclerc 93500 PANTIN - Francia Phone: +33 (0)1 48 91 01 02 www.cdvi.com CDVI AMERICAS [CANADA - USA] Phone: +1 (450) 682 7945 www.cdvi.ca CDVI BENELUX Phone: +32 (0) 56 73 93 00 www.cdvibenelux.com CDVI TAIWAN Phone: +886 (0)42471 2188 www.cdvichina.cn CDVI SWITZERLAND Phone: +41 (0)21 882 18 41 www.cdvi.ch CDVI CHINA Phone: +86 (0)10 84606132/82 www.cdvichina.cn CDVI IBERICA Phone: +34 (0)935 390 966 www.cdviberica.com CDVI ITALIA Phone: +39 0321 90 573 Fax: +39 0321 90 8018 www.cdvi.it CDVI MOROCCO Phone: +212 (0)5 22 48 09 40 www.cdvi.ma CDVI SWEDEN Phone: +46 (0)31 760 19 30 www.cdvi.se CDVI UK [UK & IRELAND] Phone: +44 (0)1628 531300 www.cdvi.co.uk CDVI POLAND Phone: +48-12-659 23 44 www.cdvi.com.pl