Datalogging / Printing Anemometer +

Psychrometer Model 451181 Introduction Congratulations on your purchase of the Extech 451181 Datalogging / Printing Anemometer + Psychrometer. This device simultaneously measures and displays Air Velocity, Temperature, Humidity, Wet Bulb Temperature, and Air Volume (CFM / CMM). The datalogger stores 2400 readings in Automatic Recording mode and 99 readings in Manual Recording mode. The Printer provides a har

Model 451181 Version 3.0 07/06

2 Meter Description 1. Sensor plug 2. LCD Display 3. F1 through F4 softkeys 4. Keypad 5. Printer paper and paper compartment 6. AC Adapter jack 7. RS-232c TTL output jack 8. Vane air velocity sensor 9. Temperature and humidity sensor housing (must be opened before use) The battery compartment is located on the back of the instrument. There are two (2) tripod mounts; one on the rear of the meter and one on the rear of the vane
Model 451181 Version 3.0 07/06 3 Operation Press the ON/OFF button to power the meter. The WELCOME screen will appear along with four softkey selections (F1 through F4): Setup The Setup Screens provides access to the LCD Contrast, Printer Contrast, Auto Power-Off time, Auto Power-Off Enable/Disable, Calendar Clock, and View configuration. Setup Screen 1 1. Press F4 SET from the WELCOME screen to access the 1st setup screen. 2. Use the ▲ or ▼ arrow keys
Model 451181 Version 3.0 07/06 4 Setup Screen 3 1. Measurement parameters with a check mark will be included on the measurement screen. Items with an ‘X’ will not be shown in the measurement screen. Use the ▲ or ▼ arrow keys to select an item and then use F2 EDIT to change from ‘X’ to a check mark or from a check mark to an ‘X’. 2. The unit of measure shown next to each measurement parameter can also be altered by first selecting with the �
Model 451181 Version 3.0 07/06 5 Measurement Procedure Air Velocity, Temperature, Relative Humidity, and Wet Bulb Measurements 1. Turn the instrument ON by pressing the ON/OFF button. 2. Turn the temperature/humidity sensor cover (located at the center of the vane) to the OPEN position. This will expose the sensors to the air flow in order to provide temperature, humidity, and wet bulb readings (see diagram). 3. Press F1 MEAS to enter the measurement mode.
Model 451181 Version 3.0 07/06 6 Air Volume Measurements Air Volume (CFM / MM) measurements require that the area of the duct or other enclosure be known. The meter can calculate the area of rectangular and circular ducts or the user can calculate the area and enter it manually. See details below: 1. Measure (in inches) the diameter of a circular duct or the length/width of a rectangular duct. Optional: Calculate the duct area. 2. Press F1 MEAS from the WE
Model 451181 Version 3.0 07/06 7 Manual Datalogging Mode The Model 451181 has two datalogging modes, MEM Manual Datalogging (99 records maximum) and Automatic Datalogging LOG (2400 records maximum). This section covers Manual Mode and the following section covers Automatic Mode. Manual Datalogging basics To take a reading and store it in memory: 1. Press F2 MEM from the WELCOME screen. 2. Use the arrow buttons to select a memory location (1 through 99) sho
Model 451181 Version 3.0 07/06 8 Customizing a Memory Location Header Using the F3 EDIT softkey in Memory screen 1, as described above, allows the user to customize the header in the currently selected memory location. 1. Use the ▲ or ▼ arrow keys to step forward and backward in the header. 2. Use the BACK softkey to step backward and erase characters while stepping. 3. Use the alphanumeric keypad to compose a header. For example, press the ‘2’ key
Model 451181 Version 3.0 07/06 9 Automatic Datalogging Mode In the Automatic Datalogging mode the Model 451181 can automatically measure and store 2400 readings at a programmed sample rate. To begin, press F3 LOG from the WELCOME display to access LOG screens 1 and 2: LOG SCREEN 1 F1 EXIT: Press to return to the WELCOME screen F2 START: Press to begin automatic Datalogging at the pre-set sampling interval. Datalogging will begin at the date/ time programme
Model 451181 Version 3.0 07/06 10 To edit the fields in the datalogger display screens: 1. Use the up and down ▲ or ▼ arrow keys to scroll through the parameters. 2. When a parameter is highlighted, use F2 EDIT to open it for editing. 3. Use the alphanumeric keypad to edit the parameter. 4. Press F4 ENTER to save changes. Press F1 ABORT to cancel changes. 5. Press the F1 EXIT to return to the SETUP screen. Recording Data in the Automatic Datalogging Mo

Extech Instruments Measuring Instruments Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
MO55W

#YLLH4A: MO55W Measuring Instruments Operation & user’s manual

8 326 62 13-04-2026
CLT600

Extech Instruments CLT600 User Guide (Quick start manual), @CXSBSW

14 1239 273 12-05-2026
407445

Measuring Instruments #522446

4 1228 197 25-06-2026
407123

407123 Operation & user’s manual - 196NAG

8 455 78 10-08-2026
SDL300

Extech Instruments SDL300 User Manual (Operation & user’s manual), @BFUFN5

13 1330 240 10-10-2026
461895

#GK431W: 461895 Measuring Instruments Instruction manual

4 1091 219 19-06-2026
TachIR RPM10

Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 19-06-2026)

7 1443 275 19-06-2026
BT100

#W928JV: BT100 Measuring Instruments Operation & user’s manual

11 103 20 07-10-2026

Measuring Instruments: Similar Manuals