• Orient the sensor so that personnel and equipment will not be exposed to any

discharge along the pressure relief path. • Stay clear of the rupture disk pressure relief area. High-pressure fluid escaping from the sensor can cause severe injury or death. Important If using a rupture disk, the housing can no longer assume a secondary containment function. NOTICE Removing the purge fitting, blind plug, or rupture disks compromises the Ex-i Safety Certification, the Ex-tc Safety Certification, and the IP-rating of the Coriolis meter. Any modification to the purge fitting, blind plug, ...

6. Wrap the drain wires twice around the shield and cut off the excess drain wires.

A. Drain wires wrapped around shield 7. For foil (shielded cable) only: Note For braided (armored cable) skip this step and contine to the next step. Option Description NPT gland type a. Slide the shielded heat shrink over the drain wires. Ensure that the wires are completely covered. b. Apply 250 °F (121.1 °C) heat to shrink the tubing. Do not burn the cable. c. Position the clamping insert so the interior end is flush with the braid of the heat shrink. A. Shielded heat shrink B. After heat is applied M20 gl ...

Before you begin

1.1 About this document This document provides information on planning, mounting, wiring, and grounding the F- Series sensor. The information in this document assumes that users understand basic transmitter and sensor installation, configuration, and maintenance concepts and procedures. 1.2 Hazard messages This document uses the following criteria for hazard messages based on ANSI standards Z535.6-2011 (R2017). DANGER Serious injury or death will occur if a hazardous situation is not avoided. WARNING Serious injury or death could occur if a hazardous situation is not avoid ...

Keep the extender and feedthrough clean and dry. Moisture or debris in the extender or

feedthrough can damage electronics and result in measurement error or flowmeter failure. Procedure 1. Remove and recycle the plastic cap from the feedthrough on the sensor. Figure 3-1: Feedthrough and extender components G H E D C A B F A. Transmitter or core processor B. Extender C. O-ring D. Feedthrough E. Clamping ring F. Clamping screw G. Plastic plug H. Plastic cap 2. Loosen the clamping screw and remove the clamping ring. Leave the O-ring in place on the feedthrough. 3. Remove and recycle the pl ...

ambient temperature is outside of the range permissible for the electronics, the

electronics must be remotely located where the ambient temperature is within the permissible range, as indicated by the shaded areas of the temperature limit graphs. • Temperature limits may be further restricted by hazardous area approvals. Refer to the hazardous area approvals documentation shipped with the sensor or at www.emerson.com/flowmeasurement. • The extended-mount electronics option allows the sensor case to be insulated without covering the transmitter, core processor, or junction box, but does not ...

Options for wiring

The wiring procedure you follow depends on which electronics option you have. Table 4-1: Wiring procedures by electronics option Electronics option Wiring procedure Integral transmitter The transmitter is already connected to the sensor. No wiring is required between sensor and transmitter. See the transmitter installation manual for wiring the power and signal cable to the transmitter. Extended electronics The electronics are separated from the sensor by an extender and must be attached as described in Attach extended electronics. There is no wiring required be ...

Emerson Micro Motion F Series user guide recommended for: PACEdge, Lumity RTS, Rosemount 8732E, Rosemount 3095FC MultiVariable, Rosemount 3095FB MultiVariable MODBUS.

⚠️ Download Safety

The Kitchen Appliances Installation manual (24 pages) is completely safe to download (last scan date: 12/02/2026).

Related PDF Instructions for Emerson Micro Motion F Series:

Kitchen Appliances Equipment: Frequently Requested

Have some Questions about Emerson Micro Motion F Series Device?

Get valuable and actionable advices from other Emerson Micro Motion F Series device users. Describe your problem or question, regarding the using of Micro Motion F Series, in as much detail as possible, and other users will be able to answer you.