FEC AM-1008W Manual 

Specifications

Brand: FEC
Category: Monitor
Model: AM-1008W (Manual )
File Type: PDF
File Size: —
Pages: 21

Read Online

Read the FEC AM-1008W Manual  online using the built-in PDF viewer.

Text of the manual

Page 1 of 21

Model Name: AM-1008W (8”) Document Version: V1.1 Customer N/A Checked & Approved by N/A Date FEC Prepared by FEC Approved by Date _________

Page 2 of 21

Record of Revision: Date Specs Ver. Description Note 2016.07.31 V0.1 Initial Draft Cary 2016.09.30 V0.2 Add Specs Cary 2016.10.30 V0.3 Add Customer Display Cary 2017.01.19 V0.4 Add Setup Instructions, Revised NFC & Customer Display Section Cary 2017.02.11 V1.0 First Release Cary 2017.06.20 V1.1 Update Model Name Update Command List Cary

Page 3 of 21

Safety and Warranty 1. Read these safety instructions carefully. 2. Keep this user's manual for later reference. 3. Disconnect from power outlet before cleaning, disassembly or transport. Do not use liquid or spray detergents for cleaning. Use a damp cloth only and avoid any prolonged contact with moisture. 4. Keep the unit away from humidity. 5. Place the unit on a sturdy surface before servicing or operation to prevent accidental drops. 6. The openings on the enclosure are for ventilation. Do NOT cover the openings. 7. Make sure the voltage and load ratings of the power source are correct before connecting the equipment to the power outlet. 8. Position the power cord to prevent accidental tripping. Do not twist, pinch or clip the power cord. 9. All cautions and warnings printed on the equipment should be followed. 10. If the equipment is not used for a long time, disconnect it from the power source. 11. Never pour any liquid into an opening. This could cause fire or electrical shock. 12. For safety reasons, only qualified service personnel should open and service the equipment. 13. If any of the following situations arises, get the equipment checked by service

Page 4 of 21

personnel:  The power cord, plug, or adapter is visibly damaged.  Liquid has entered into the equipment.  The equipment has been exposed to moisture.  The equipment does not work as intended, or you cannot get it to work according to the user’s manual.  The equipment has been dropped and damaged.  The equipment has obvious signs of breakage. 14. DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW -20° C (-4°F) OR ABOVE 60° C (140° F).

Page 5 of 21

Contents Chapter 1 – Introduction 6 About AM-1008W 6 Overview 7 I/O Layout 7 Package Contents 7 Chapter 2 – Hardware & Software 9 Standalone Setup 9 Connecting to System 16 Customer Display Option 16 NFC Option 17 Chapter 3 – Specifications 17 Appendix A – Customer Display Command List 18

Page 6 of 21

Chapter 1 – Introduction About AM-1008W AM-1008W is a new type of multifunction LCD display. Featuring 8” widescreen LCD panel with bright LED backlight, slim frame and innovative features. Main Features:  All in one compact design with integrated and standalone mounting options.  HD LCD panel with high brightness and contrast for optimal viewing.  Optional 20x2 Customer Display emulation with overlay.  Optional NFC module featuring read/write functions

Page 7 of 21

Overview Unit Dimensions Mounting Options Standalone Integrated Mount Wallmount I/O Layout AM-1008W features an unique all-in-one connection allowing simple setup and cable management. A custom-designed connector houses both video and power supply. Depending on the SKU ordered, your cable may look different from the illustrations below. Package Contents (Content may differ depending on configuration and pre-assembly) 211mm 135mm

Page 8 of 21

Standard Optional Items 1 AM-1008W Main Display Unit 1 AerARM with Bracket 2 Integrated Cable 2 Extension tubes, standalone base 3 3 Wallmount Kit 4 4

Page 9 of 21

Chapter 2 – Hardware & Software Standalone Setup 1. Unpack the contents 2. Take the two extension tubing and assemble them by pressing the two nipples inward and slide them into the cavity as shown. The nipple will click into the opening and lock. Do not perform any service or upgrade without shutting down the terminal first. Power must be switched off and power cord must be unplugged. Failure to do so may result in system damage which is not covered by FEC warranty.

Page 10 of 21

3. Unwrap the cable from its protective bag and untie the cable tie to loosen the cables. CLICK!

Page 11 of 21

4. Starting with the thinnest cable (USB or RS232, thread it through the base opening as shown. 5. Keeping the threaded cable to the left side, thread the video signal cable (HDMI or VGA) through as shown.

Page 12 of 21

6. Align the extension tubes with docking socket facing the narrow side of the base, pull the cables through and assemble the extension tubing to the base using the method outlined in Step 2.

Page 13 of 21

7. Tilt the stand over and thread the cables as shown (thinnest cable always first) CLICK!

Page 14 of 21

8. Dock the screen as shown by aligning the points circled and push the screen downward to dock with the stand. 9. Lay the unit face down and attach the two screws as shown.

Page 16 of 21

Connecting to System Please follow these steps to ensure proper function and display resolution. 1. Plug in either the USB or RS232 cable to your system first. If unit is equipped with NFC module, you will hear a soft beep. 2. Attach the signal cable (HDMI or VGA) to the system. The display should be functional momentarily. 3. If nothing is displayed, first check your system is configured properly, then disconnect the cabled and repeat Step 1 & 2 again. Customer Display Option AM-1008W can emulate 20x2 VFD compatible with EPSON commands. The output is displayed using overlay technology. COM Port Settings Baud rate: 9600 Data Bit: 8 Parity: None Stop Bit: 1 Supported Commands

Page 17 of 21

Please refer to command chart at the end of the manual. NFC Option 1. The NFC module is configured to be HID USB read only by default. To enable Virtual COM read/write mode, please install the Virtual COM driver provided by FEC. 2. If the driver is not included, please contact your FEC representative. Chapter 3 – Specifications

Page 18 of 21

*specifications are subject to change without notice. Contact your nearest FEC representative for latest information. Appendix A – Customer Display Command List Command Function Description 09 Move cursor right 08 Move cursor left 1F 0A Move cursor up 0A Move cursor down 1F 0D Move cursor to right-most position 0D Move cursor to left-most position 0B Move cursor to home position 1F 42 Move cursor to bottom position 1F 24 x y Move cursor to specified position 1≦x(column)≦20 ; 1≦y(row)≦2

Page 19 of 21

1F 43 n Select/cancel cursor display n=0, canceled ; n=1, selected 0C Clear display screen 18 Clear cursor line 1F 58 n Brightness adjustment 1≦n≦4 1F 45 n Blink display screen 0≦n≦255 (n*50msec) ON / (n*50msec) OFF n= 0, blinking is canceled n=255, display is turned off 1B 40 Initialize display 1B 74 n Select character code table 0≦n≦5 ( Please refer “Chapter 5” ) 1B 52 n Select international character set ( Please refer International Font Set Table ) 1F 72 n Select/cancel reverse character n=0, canceled ; n=1, selected Command Function Description 1F 01 Specify overwrite mode 1F 02 Specify vertical scroll mode 1F 03 Specify horizontal scroll mode 1B 57 n s (x1 y1 x2 y2) Specify/cancel the window range n=1,2,3,4 (four windows) ; s=0,1 (disable, enable) 1≦x1≦x2≦20 (column) ; 1≦y1≦y2≦2 (row) 1F 3A Set starting/ending position of macro definition 1F 5E n m Execute and quit macro 0≦(n,m)≦255 n: specifies the time interval for display of characters in units of [n* 50msec] m: specifies the interval of macro execution every [m*50msec] 1F 40 Execute self-test 1F 54 h m Display time :0≦h≦23 ; 0≦m≦59 1F 55 Display of time counter

Page 20 of 21

1A 1B Enter Burn In Test Mode 1A 1C Break Burn In test mode 1A 1E Exit Burn In test mode 1A 01 Display Monitor Model 1A 02 0D Edit Monitor model name n = 1 ~ 16 bytes 1A 03 n 0D Power Saving mode n = 0, power saving mode off; n = 1, power saving mode on; (Default) 1E 03 Display A/D board model and firmware version and production date 1E 06 n 0D Edit A/D board serial number n = 1 ~ 32bytes 1E 05 Read A/D board serial number 1E 08 n 0D Edit Monitor serial number n = 1 ~ 32bytes 1E 07 Read Monitor serial number 1E 10 Read international character set 1E 11 n Select international character set (20-7F) n= 0 ~ B 1E 0C Read character code table 1E 0B n Select character code table (80-FF) n= 0 ~ B 1E 12 Read Baud rate setting 1E 13 E6 DF FF EC 96 00 Write Baud rate setting : 9600 1E 13 69 FF FE C1 92 00 Write Baud rate setting : 19200 1E 13 69 FF FE C3 84 00 Write Baud rate setting : 38400 1E 14 Read Display turn on time 1E 16 Read total transmitted data quantity 1E 20 RESET Customer Display

Page 21 of 21

1E 21 Full Screen : White color 1E 22 Full Screen : Red color 1E 23 Full Screen : Blue color 1E 24 Full Screen : Green color 1E 25 Full Screen : Black color 1E 26 Cancel R , G , B Color 1E 2D Display Resolution and Frequency 1E 30 Display Power On-Off and Reset Count 1E 31 Display Burn In time 1E 32 Counter Reset (Power-on time, power cycle count, reset count, burn-in time) 1E 33 n Set Display Font Color 0<=n<=7 0=Black 1=WHITE, 2=RED, 3=GREEN, 4=BLUE, 5=YELLOW, 6=GRAY, 7=DARKBLUE, 1E 34 n Set Background Color 0<=n<=7 0=Black 1=WHITE, 2=RED, 3=GREEN, 4=BLUE, 5=YELLOW, 6=GRAY, 7=DARKBLUE, 1E 35 n Set Customer Display Background Location 0<=n<=200

Other Monitor Manuals