Maximum Fluid Working Pressure:
250 psi (1.72 MPa, 17.2 bar)
Maximum Air Input Pressure: 125 psi
(0.86 MPa, 8.6 bar)
See page 4 for approvals.
PROVEN QUALITY. LEADING TECHNOLOGY.
Related Manuals ................................................ 2
Ordering Information........................................... 3
Configuration Number Matrix............................... 4
Warnings ........................................................... 5
Installation.......................................................... 8
Tighten Fasteners Before Setup.................... 8
Mounting ..................................................... 8
Grounding ................................................... 8
Air Line........................................................ 9
Air Exhaust Ventilation ................................. 10
Fluid Supply Line ......................................... 11
Fluid Outlet Line........................................... 11
Fluid Inlet and Outlet Ports ........................... 11
Typical Floor Mount Installation..................... 12
Operation........................................................... 13
Pressure Relief Procedure............................ 13
Tighten Fasteners Before Setup.................... 13
Flush the Pump Before First Use .................. 13
High/Low Lever............................................ 13
Start and Adjust the Pump............................ 14
Pump Shutdown .......................................... 14
Maintenance ...................................................... 15
Maintenance Schedule................................. 15
Lubrication................................................... 15
Tighten Threaded Connections ..................... 15
Flushing and Storage ................................... 15
Torque Instructions ...................................... 16
Dimensions and Mounting................................... 17
Performance Charts............................................ 18
Technical Data ................................................... 20
Fluid Temperature Range............................. 21
Graco Standard Husky Pump Warranty................ 22
Related
Related
Related Manuals
Manuals
Manuals
Manual
Manual
Manual No.
No.
No.
Description
Description
Description
334390
Husky 1050HP Air-Operated Diaphragm Pump, Repair/Parts
NOTE:
NOTE:
NOTE: For Troubleshooting information, see the
Repair/Parts Manual 334390.
2
334014D
Click on Where
Where
Where toto
to Buy
Buy
Buy and use the Distributor
Distributor
Distributor
Locator.
Locator.
Locator.
To
To
To Specify
Specify
Specify the
the
the Configuration
Configuration
Configuration ofof
of aaa New
New
New
Pump
Pump
Pump
Please
Please
Please call
call
call your
your
your distributor.
distributor.
distributor.
To
To
To Order
Order
Order Replacement
Replacement
Replacement Parts
Parts
Parts
Please
Please
Please call
call
call your
your
your distributor.
distributor.
distributor.
Distributor
Distributor
Distributor Note
Note
Note
1.
To find part numbers for replacement parts:
a.
Use the 20–digit number from the ID plate
on the pump.
b.
Use the Configuration Number Matrix on the
next page to understand which parts are
described by each digit.
c.
Use
Use
Use the
the
the Repair/Parts
Repair/Parts
Repair/Parts Manual.
Manual.
Manual. Refer to the
main Parts illustration and to the Parts/Kits
Quick Reference. Follow the page references
on these two pages for further ordering
information, as needed.
2.
Please call Graco Customer Service to order.
334014D
3
Configuration Number Matrix
Configuration
Configuration
Configuration Number
Number
Number Matrix
Matrix
Matrix
Check the identification plate (ID) for the 20–digit
Configuration Number of your pump. Use the
following matrix to define the components of your
pump.
Sample
Sample
Sample Configuration
Configuration
Configuration Number:
Number:
Number:
1050HP
1050HP
1050HP
A01A
A01A
A01A
A1
A1
A1
SS
SS
SS
SP
SP
SP
SP
SP
SP
PT
PT
PT
Pump Model
Center Section
and Air Valve
Manifolds
Seats
Balls
Diaphragms
Manifold
O-Rings
Pump
Pump
Pump
Center
Center
Center Section
Section
Section and
and
and Air
Air
Air Valve
Valve
Valve
Material
Material
Material
Air
Air
Air Valve
Valve
Valve
Manifolds
Manifolds
Manifolds
A1
A1
A1
Aluminum, standard ports, npt
A2
A2
A2
Aluminum, standard ports, bsp
S1
S1
S1
Stainless steel, standard ports, npt
1050HP
1050HP
1050HP
Aluminum
Aluminum
A01A
A01A
A01A
Standard
S2
S2
S2
Stainless steel, standard ports, bsp
Check
Check
Check Valve
Valve
Valve Seats
Seats
Seats
Check
Check
Check Valve
Valve
Valve Balls
Balls
Balls
Diaphragm
Diaphragm
Diaphragm Material
Material
Material
Manifold
Manifold
Manifold OO
O---Rings
Rings
Rings
GE
GE
GE
Geolast®
CW
CW
CW
Polychloroprene
Weighted
BN
BN
BN
Buna-N
PT
PT
PT
PTFE
SP
SP
SP
Santoprene®
GE
GE
GE
Geolast
CO
CO
CO
Polychloroprene
Overmolded
SS
SS
SS
316 Stainless Steel
SP
SP
SP
Santoprene
PT
PT
PT
PTFE/Santoprene
Two-Piece
SS
SS
SS
316 Stainless Steel
SP
SP
SP
Santoprene
Approvals
Approvals
Approvals
All models are rated:
II 2 GD
Ex h IIC 66ºC...135ºC Gb
Ex h IIIC T135ºC Db
4
334014D
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific
risks. When these symbols appear in the body of this manual or on warning labels, refer back to these
Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout
the body of this manual where applicable.
WARNING
WARNING
WARNING
FIRE
FIRE
FIRE AND
AND
AND EXPLOSION
EXPLOSION
EXPLOSION HAZARD
HAZARD
HAZARD
Flammable fumes, such as solvent and paint fumes, in work
work
work area
area
area can ignite or explode. To help
prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and
plastic drop cloths (potential static arc).
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable
fumes are present.
• Ground all equipment in the work area. See Grounding
Grounding
Grounding instructions.
• Use only grounded hoses.
• Stop
Stop
Stop operation
operation
operation immediately
immediately
immediately if static sparking occurs or you feel a shock... Do not use
equipment until you identify and correct the problem.
• Keep a working fire extinguisher in the work area.
• Route exhaust away from all ignition sources. If diaphragm ruptures, fluid may be exhausted
with air.
PRESSURIZED
PRESSURIZED
PRESSURIZED EQUIPMENT
EQUIPMENT
EQUIPMENT HAZARD
HAZARD
HAZARD
Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin
and cause serious injury.
• Follow the Pressure
Pressure
Pressure Relief
Relief
Relief Procedure
Procedure
Procedure when you stop spraying/dispensing and before
cleaning, checking, or servicing equipment.
• Tighten all fluid connections before operating the equipment.
• Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
334014D
5
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated
system component. See Technical
Technical
Technical Data
Data
Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical
Technical
Technical Data
Data
Data
in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete
information about your material, request MSDS from distributor or retailer.
• Do not leave the work area while equipment is energized or under pressure.
• Turn off all equipment and follow the Pressure
Pressure
Pressure Relief
Relief
Relief Procedure
Procedure
Procedure when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine
manufacturer’s replacement parts only.
• Do not alter or modify equipment. Alterations or modifications may void agency approvals
and create safety hazards.
• Make sure all equipment is rated and approved for the environment in which you are using it.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
PRESSURIZED
PRESSURIZED
PRESSURIZED ALUMINUM
ALUMINUM
ALUMINUM PARTS
PARTS
PARTS HAZARD
HAZARD
HAZARD
Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious
chemical reaction and equipment rupture. Failure to follow this warning can result in death,
serious injury, or property damage.
• Do not use 1,1,1–trichloroethane, methylene chloride, other halogenated hydrocarbon
solvents or fluids containing such solvents.
• Do not use chlorine bleach.
• Many other fluids may contain chemicals that can react with aluminum. Contact your material
supplier for compatibility.
THERMAL
THERMAL
THERMAL EXPANSION
EXPANSION
EXPANSION HAZARD
HAZARD
HAZARD
Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure
due to the thermal expansion. Over-pressurization can result in equipment rupture and serious
injury.
• Open a valve to relieve the fluid expansion during heating.
• Replace hoses proactively at regular intervals based on your operating conditions.
6
334014D
Many solvents can degrade plastic parts and cause them to fail, which could cause serious
injury or property damage.
• Use only compatible water-based solvents to clean plastic structural or pressure-containing
parts.
• See Technical
Technical
Technical Data
Data
Data in this and all other equipment instruction manuals. Read fluid and
solvent manufacturer’s MSDSs and recommendations.
TOXIC
TOXIC
TOXIC FLUID
FLUID
FLUID OR
OR
OR FUMES
FUMES
FUMES HAZARD
HAZARD
HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin,
inhaled, or swallowed.
• Read MSDSs to know the specific hazards of the fluids you are using.
• Route exhaust away from work area. If diaphragm ruptures, fluid may be exhausted into
the air.
• Store hazardous fluid in approved containers, and dispose of it according to applicable
guidelines.
BURN
BURN
BURN HAZARD
HAZARD
HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid
severe burns:
• Do not touch hot fluid or equipment.
PERSONAL
PERSONAL
PERSONAL PROTECTIVE
PROTECTIVE
PROTECTIVE EQUIPMENT
EQUIPMENT
EQUIPMENT
Wear appropriate protective equipment when in the work area to help prevent serious injury,
including eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective
equipment includes but is not limited to:
• Protective eyewear, and hearing protection.
• Respirators, protective clothing, and gloves as recommended by the fluid and solvent
manufacturer.
334014D
7
The Typical Floor Mount Installation, page 12, is
only a guide for selecting and installing system
components. Contact your Graco distributor for
assistance in planning a system to suit your needs.
Tighten
Tighten
Tighten Fasteners
Fasteners
Fasteners Before
Before
Before Setup
Setup
Setup
Before using the pump for the first time, check
and retorque all external fasteners. Follow
Torque Instructions, page 16. After the first day of
operation, retorque the fasteners.
Mounting
Mounting
Mounting
• The pump exhaust air may contain
contaminants. Ventilate to a remote
area. See Air Exhaust Ventilation, page 10.
• Never move or lift a pump under pressure. If
dropped, the fluid section may rupture. Always
follow the Pressure Relief Procedure, page 13,
before moving or lifting the pump.
1.
Be sure the mounting surface can support the
weight of the pump, hoses, and accessories, as
well as the stress caused during operation.
2.
For all mountings, be sure the pump is bolted
directly to the mounting surface. Mount the pump
horizontally, with the feet at the bottom of the
pump. Do not mount the pump on a vertical
surface, such as a wall.
3.
For ease of operation and service, mount the
pump so air valve, air inlet, fluid inlet and fluid
outlet ports are easily accessible.
Grounding
Grounding
Grounding
The equipment must be grounded to reduce the
risk of static sparking. Static sparking can cause
fumes to ignite or explode. Grounding provides an
escape wire for the electric current.
• Pump:
Pump:
Pump: Loosen the grounding screw (GS). Insert
one end of a 12 ga. minimum ground wire (R)
behind the grounding screw and tighten the screw
securely. Do not exceed 15 in-lb (1.7 N•m).
Connect the clamp end of the ground wire to a
true earth ground. A ground wire and clamp, Part
238909, is available from Graco.
Figure 1 Grounding Screws and Wires
8
334014D
hoses: Use only grounded hoses
with a maximum of 500 ft (150 m) combined hose
length to ensure grounding continuity.
• Air
Air
Air compressor:
compressor:
compressor: Follow manufacturer’s
recommendations.
Check your system electrical continuity after the
initial installation, and then set up a regular schedule
for checking continuity to be sure proper grounding
is maintained.
Air
Air
Air Line
Line
Line
See Typical Floor Mount Installation, page 12
1.
Install an air filter/regulator (C). An air line filter
removes harmful dirt and moisture from the
compressed air supply. Use the regulator and
gauge to control the fluid pressure. The fluid stall
pressure will be the same as the setting of the
air regulator.
2.
Locate a bleed-type master air valve (B) close to
the pump and use it to relieve trapped air. Be
sure the valve is easily accessible from the pump
and located downstream from the regulator.
Trapped air can cause the pump to cycle
unexpectedly, which could result in serious
injury from splashing.
3.
Locate another master air valve (E) upstream
from all air line accessories and use it to isolate
them during cleaning and repair.
4.
An adjustable inlet air valve or needle valve (G)
my be installed for pump speed control.
5.
Install a grounded, flexible air hose (A) between
the accessories and the 3/4 npt(f) pump air inlet
(D). Use a minimum 5/8 in. (16 mm) ID air hose.
334014D
9
The air exhaust port is 3/4 npt(f). Do not restrict the
air exhaust port. Excessive exhaust restriction can
cause erratic pump operation.
To provide a remote exhaust:
1.
Remove the muffler (T) from the pump air
exhaust port.
2.
Install a grounded air exhaust hose (U). Connect
the muffler (T) to the other end of the hose. The
minimum size for the air exhaust hose is 3/4 in.
(19 mm) ID. If a hose longer than 15 ft (4.57 m)
is required, use a larger diameter hose. Avoid
sharp bends or kinks in the hose.
3.
Place a container at the end of the air exhaust
line to catch fluid in case a diaphragm ruptures.
If the diaphragm ruptures, the fluid being pumped
will exhaust with the air.
Figure 2 Vent exhaust air
KEY
KEY
KEY
AAA
Air supply line
GG
G Optional needle valve for pump speed
adjustment.
BBB
Bleed-type master air valve
TTT
Muffler
CCC
Air filter/regulator
UUU
Grounded air exhaust hose
DDD
Air inlet
VVV
Container for remote air exhaust
EEE
Master air valve (for accessories)
10
334014D
See Typical Floor Mount Installation, page 12
1.
Use grounded flexible, fluid supply hoses (G).
See Grounding, page 8 .
2.
If the inlet fluid pressure to the pump is more
than 25% of the outlet working pressure, the ball
check valves will not close fast enough, resulting
in inefficient pump operation.
3.
Excessive inlet fluid pressure also will shorten
diaphragm life. Approximately 3 - 5 psi (0.02-
0.03 MPa, 0.21-0.34 bar) should be adequate
for most materials.
4.
For maximum suction lift (wet and dry), see
Technical Data, page 20. For best results,
always install the pump as close as possible to
the material source.
Fluid
Fluid
Fluid Outlet
Outlet
Outlet Line
Line
Line
See Typical Floor Mount Installation, page 12.
1.
Use grounded, flexible fluid hoses (L). See
Grounding, page 8 .
2.
Install a fluid drain valve (J) near the fluid outlet.
3.
Install a shutoff valve (K) in the fluid outlet line.
Fluid
Fluid
Fluid Inlet
Inlet
Inlet and
and
and Outlet
Outlet
Outlet Ports
Ports
Ports
NOTE:
NOTE:
NOTE: Remove and reverse the manifold(s) to
change the orientation of inlet or outlet port(s). Follow
Torque Instructions, page 16.
1050HP
1050HP
1050HP —
—
— Aluminum
Aluminum
Aluminum Manifolds
Manifolds
Manifolds
The fluid inlet and outlet manifolds each have two 1
in. npt(f) or bspt threaded ports (M, N). Close off the
unused port using the supplied plugs.
1050HP
1050HP
1050HP —
—
— Stainless
Stainless
Stainless Steel
Steel
Steel Manifolds
Manifolds
Manifolds
The fluid inlet and outlet manifolds each have one
1 in. npt(f) or bspt port.
334014D
11
Figure 3 Typical floor mount installation
KEY
KEY
KEY
AAA
Air supply line
JJJ
Fluid drain valve (required)
BBB
Bleed-type master air valve (required for
pump)
KKK
Fluid shutoff valve
CCC
Air filter and regulator
LLL
Flexible fluid outlet hose
DDD
Air inlet
MM
M
Fluid inlet (2 ports on aluminum manifolds,1
port on SST manifolds)
EEE
Master air valve (for accessories)
NNN
Fluid outlet (2 ports on aluminum manifolds,1
port on SST manifolds)
FFF
Flexible fluid suction hose
RRR
Ground wire (required; see
Grounding, page 8 ).
GG
G
Optional needle valve for pump speed
adjustment.
12
334014D
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is relieved manually. To help prevent serious
injury from pressurized fluid, such as splashing
in the eyes or on skin, follow the Pressure Relief
Procedure when you stop pumping and before you
clean, check, or service the equipment.
1.
Shut off the air supply to the pump.
2.
Open the dispensing valve, if used.
3.
Shift the high/low pressure lever back and forth
two times. Leave the lever in the “Low” position
as shown.
Figure 4 High/Low Pressure Lever
4.
Open the fluid drain valve (installed on the
system) to relieve all fluid pressure. Have a
container ready to catch the drainage.
Tighten
Tighten
Tighten Fasteners
Fasteners
Fasteners Before
Before
Before Setup
Setup
Setup
Before using the pump for the first time, check
and retorque all external fasteners. Follow
Torque Instructions, page 16. After the first day of
operation, retorque the fasteners.
Flush
Flush
Flush the
the
the Pump
Pump
Pump Before
Before
Before First
First
First Use
Use
Use
The pump was tested in water. If water could
contaminate the fluid you are pumping, flush the
pump thoroughly with a compatible solvent. See
Flushing and Storage, page 15.
High/Low
High/Low
High/Low Lever
Lever
Lever
Use the High/Low lever to set the desired pressure
mode. When the lever is set to “Low,” the fluid outlet
pressure is slightly less than the air inlet pressure.
When the lever is set to “High,” the fluid outlet
pressure is slightly less than two times the inlet
air pressure. Note that the High pressure setting
increases both fluid outlet pressure and inlet air
consumption.
NOTE:
NOTE:
NOTE: The lever must be fully seated into the High
or Low position for proper operation.
334014D
13
Be sure the pump is properly grounded. Refer
to Grounding, page 8 .
2.
Ensure the High/Low pressure lever is in the
“Low” position before starting the pump.
3.
Check all fittings to be sure they are tight. Use
a compatible liquid thread sealant on all male
threads. Tighten fluid inlet and outlet fittings
securely.
4.
Place the suction tube (if used) in the fluid to be
pumped.
NOTE:
NOTE:
NOTE: If fluid inlet pressure to the pump is more
than 25% of outlet working pressure, the ball
check valves will not close fast enough, resulting
in inefficient pump operation.
NOTICE
NOTICE
NOTICE
Excessive fluid inlet pressure can reduce
diaphragm life and may result in pump damage.
5.
Place the end of the fluid hose into an appropriate
container.
6.
Close the fluid drain valve.
7.
Turn the air regulator knob to 0. Open all
bleed-type master air valves.
8.
If the fluid hose has a dispensing device, hold
it open.
9.
Slowly increase air pressure with the air regulator
until the pump starts to cycle. Allow the pump to
cycle slowly until all air is pushed out of the lines
and the pump is primed.
NOTE:
NOTE:
NOTE: Use lowest possible air pressure to prime,
just enough to cycle the pump. If the pump does
not prime as expected, turn air pressure DOWN.
DOWN.
DOWN.
10. If you are flushing, run the pump long enough to
thoroughly clean the pump and hoses.
11. Close the dispensing valve, if used.
12. Close the bleed-type master air valve.
Pump
Pump
Pump Shutdown
Shutdown
Shutdown
At the end of the work shift and before you check,
adjust, clean or repair the system, follow the
Pressure Relief Procedure, page 13.
14
334014D
Establish a preventive maintenance schedule,
based on the pump’s service history. Scheduled
maintenance is especially important to prevent spills
or leakage due to diaphragm failure.
Lubrication
Lubrication
Lubrication
The pump is lubricated at the factory. It is designed
to require no further lubrication for the life of the
pump. An inline lubricator is not needed, and is not
recommended, under normal operating conditions.
Tighten
Tighten
Tighten Threaded
Threaded
Threaded Connections
Connections
Connections
Before each use, check all hoses for wear or
damage, and replace as necessary. Check to be
sure all threaded connections are tight and leak-free.
Check fasteners. Tighten or retorque as necessary.
Although pump use varies, a general guideline
is to retorque fasteners every two months. See
Torque Instructions, page 16.
Flushing
Flushing
Flushing and
and
and Storage
Storage
Storage
• Flush before fluid can dry in the equipment, at the
end of the day, before storing, and before repairing
equipment.
• Flush at the lowest pressure possible. Check
connectors for leaks and tighten as necessary.
• Flush with a fluid that is compatible with the fluid
being dispensed and the equipment wetted parts.
Flush the pump often enough to prevent the fluid you
are pumping from drying or freezing in the pump and
damaging it. Use a compatible solvent.
Always flush the pump and relieve the pressure
before storing it for any length of time.
334014D
15
NOTE: All fasteners for the fluid covers, center
diaphragm joint, and manifolds have a thread-locking
adhesive patch applied to the threads. If this patch is
excessively worn, the fasteners may loosen during
operation. Replace screws with new ones or apply
medium-strength (blue) Loctite or equivalent to the
threads.
If fluid cover, center diaphragm joint, or manifold
fasteners have been loosened, it is important to
torque them using the following procedure to improve
sealing.
NOTE:
NOTE:
NOTE: Always completely torque the fluid covers and
center diaphragm joint before torquing the manifolds.
Start all fluid cover or center diaphragm joint screws a
few turns. Then turn down each screw just until head
contacts cover. Then turn each screw by 1/2 turn
or less working in a crisscross pattern to specified
torque. Repeat for manifolds.
Fluid
Fluid
Fluid cover,
cover,
cover, center
center
center diaphragm
diaphragm
diaphragm joint,
joint,
joint, and
and
and manifold
manifold
manifold
fasteners:
fasteners:
fasteners: 100 in-lb (11.3 N•m)
Lubricate air valve fasteners prior to reassembly to
prevent galling. Retorque the air valve fasteners in a
crisscross pattern to specified torque.
Air
Air
Air valve
valve
valve fasteners:
fasteners:
fasteners: 80 in-lb (9.0 N•m)
Air
Air
Air Valve
Valve
Valve Fasteners
Fasteners
Fasteners
Fluid
Fluid
Fluid Covers
Covers
Covers and
and
and Center
Center
Center Diaphragm
Diaphragm
Diaphragm Joint
Joint
Joint
Manifolds
Manifolds
Manifolds
16
334014D
Dimensions and Mounting
Dimensions
Dimensions
Dimensions and
and
and Mounting
Mounting
Mounting
KEY
KEY
KEY
Aluminum
Aluminum
Aluminum
SST
SST
SST
Aluminum
Aluminum
Aluminum and
and
and SST
SST
SST
AAA
12.7 in (323 mm)
11.8 in (300 mm)
HHH
6.2 in (157 mm)
BBB
14.4 in (366 mm)
12.9 in (328 mm)
JJJ
9.4 in (239 mm)
CCC
15.3 in (389 mm)
13.7 in (348 mm)
KKK
15.6 in (396 mm)
DDD
10.9 in (277 mm)
9.5 in (241 mm)
LLL
3/4 npt(f) Air Inlet
EEE
1.8 in (46 mm)
1.1 in (28 mm)
MM
M
1 in npt(f) or 1 in. bspt Fluid Inlet
(2 for aluminum manifolds; 1 for SST manifolds)
FFF
10.8 in (274 mm)
10.7 in (272 mm)
NNN
1 in npt(f) or 1 in. bspt Fluid Outlet
(2 for aluminum manifolds; 1 for SST manifolds)
GG
G
21.5 in (546 mm)
20.6 in (523 mm)
PPP
3/4 npt(f) Air Exhaust Port
NOTE:
NOTE:
NOTE: All dimensions are approximate.
334014D
17
125 psi (0.86 MPa, 8.6 bar)
BBB
100 psi (0.7 MPa, 7.0 bar)
CCC
70 psi (0.48 MPa, 4.8 bar)
DDD
40 psi (0.28 MPa, 2.8 bar)
EEE
20 psi (0.14 MPa, 1.4 bar)
Air
Air
Air Consumption
Consumption
Consumption
Approximate
Approximate
Approximate Cycles
Cycles
Cycles per
per
per Minute
Minute
Minute
How
How
How toto
to Read
Read
Read the
the
the Charts
Charts
Charts
1.
Locate fluid flow rate along
bottom of chart.
2.
Follow vertical line up to
intersection with selected
operating air pressure
curve.
3.
Follow left to scale to read
fluid
fluid
fluid outlet
outlet
outlet pressure
pressure
pressure (top
chart) or air
air
air consumption
consumption
consumption
(bottom chart)
scfm
scfm
scfm
(Nm
(Nm
(Nm333/min.)
/min.)
/min.)
0
20
(0.6)
40
(1.1)
60
(1.7)
80
(2.3)
100
(2.8)
0
0
10
(38)
20
(76)
30
(114)
40
(151)
50
(189)
56
112
168
224
280
A
B
C
D
E
Fluid
Fluid
Fluid Flow
Flow
Flow —
—
— gpm
gpm
gpm (lpm)
(lpm)
(lpm)
18
334014D
125 psi (0.86 MPa, 8.6 bar)
BBB
100 psi (0.7 MPa, 7.0 bar)
CCC
70 psi (0.48 MPa, 4.8 bar)
DDD
40 psi (0.28 MPa, 2.8 bar)
EEE
20 psi (0.14 MPa, 1.4 bar)
Air
Air
Air Consumption
Consumption
Consumption
Approximate
Approximate
Approximate Cycles
Cycles
Cycles per
per
per Minute
Minute
Minute
How
How
How toto
to Read
Read
Read the
the
the Charts
Charts
Charts
1.
Locate fluid flow rate along
bottom of chart.
2.
Follow vertical line up to
intersection with selected
operating air pressure
curve.
3.
Follow left to scale to read
fluid
fluid
fluid outlet
outlet
outlet pressure
pressure
pressure (top
chart) or air
air
air consumption
consumption
consumption
(bottom chart)
scfm
scfm
scfm
(Nm
(Nm
(Nm333/min.)
/min.)
/min.)
0
25
(0.7)
50
(1.4)
75
(2.1)
100
(2.8)
125
(3.5)
0
0
10
(38)
20
(76)
30
(114)
40
(151)
50
(189)
50
100
150
200
250
A
B
C
D
E
Fluid
Fluid
Fluid Flow
Flow
Flow —
—
— gpm
gpm
gpm (lpm)
(lpm)
(lpm)
334014D
19
1.72 MPa,17.2 bar
Air
Air
Air pressure
pressure
pressure operating
operating
operating range
range
range
20-125 psi
0.14-0.86 MPa, 1.4-8.6 bar
Fluid
Fluid
Fluid displacement
displacement
displacement per
per
per cycle
cycle
cycle
Low Pressure Setting
0.17 g
0.64 l
High Pressure Setting
0.20 g
0.76 l
Air
Air
Air consumption
consumption
consumption
atat
at 70
70
70 psi,
psi,
psi, 20
20
20 gpm
gpm
gpm
atat
at 4.8
4.8
4.8 bar,
bar,
bar, 76
76
76 lpm
lpm
lpm
Low Pressure Setting
26 scfm
0.7 cubic meters per minute
High Pressure Setting
51 scfm
1.4 cubic meters per minute
Maximum
Maximum
Maximum values
values
values with
with
with water
water
water as
as
as media
media
media under
under
under submerged
submerged
submerged inlet
inlet
inlet conditions
conditions
conditions atat
at ambient
ambient
ambient temperature:
temperature:
temperature:
Maximum air consumption
Low Pressure Setting
59 scfm
1.7 cubic meters per minute
High Pressure Setting
95 scfm
2.7 cubic meters per minute
Maximum free-flow delivery
Low Pressure Setting
50 gpm
189 lpm
High Pressure Setting
46 gpm
174 lpm
Maximum pump speed
Low Pressure Setting
280 cpm
High Pressure Setting
225 cpm
Maximum suction lift (varies widely
based on ball/seat selection and
wear, operating speed, material
properties, and other variables)
16 ft dry,
29 ft wet
4.9 m dry
8.8 m wet
Maximum
Maximum
Maximum size
size
size pumpable
pumpable
pumpable solids
solids
solids
1/8 in
3.2 mm
Recommended
Recommended
Recommended cycle
cycle
cycle rate
rate
rate for
for
for continuous
continuous
continuous
use
use
use
93–140 cpm
(in Low or High setting)
Recommended
Recommended
Recommended cycle
cycle
cycle rate
rate
rate for
for
for circulation
circulation
circulation
systems
systems
systems
20 cpm
(in Low or High setting)
Air
Air
Air inlet
inlet
inlet size
size
size
3/4 npt(f)
Fluid
Fluid
Fluid inlet
inlet
inlet size
size
size
1 in. npt(f) or 1 in. bspt
Fluid
Fluid
Fluid outlet
outlet
outlet size
size
size
1 in. npt(f) or 1 in. bspt
Weight
Weight
Weight
48 lb (aluminum manifolds)
60 lb (SST manifolds)
21.8 kg (aluminum manifolds)
27.2 kg (SST manifolds)
20
334014D
California Proposition 65
Sound
Sound
Sound Power
Power
Power (measured per ISO-9614–2)
At 70 psi (0.48 MPa, 4.8 bar) and 50 cpm
Low Pressure Setting
78 dBa
High Pressure Setting
91 dBa
At 100 psi (0.7 MPa, 7.0 bar) and full flow
Low Pressure Setting
90 dBa
High Pressure Setting
102 dBa
Sound
Sound
Sound Pressure
Pressure
Pressure (tested 3.28 ft [1 m] from equipment)
At 70 psi (0.48 MPa, 4.8 bar) and 50 cpm
Low Pressure Setting
84 dBa
High Pressure Setting
96 dBa
At 100 psi (0.7 MPa, 7.0 bar) and full flow
Low Pressure Setting
84 dBa
High Pressure Setting
96 dBa
Wetted
Wetted
Wetted parts
parts
parts
aluminum plus the material(s) chosen for seat, ball,
and diaphragm options.
Non
Non
Non---wetted
wetted
wetted external
external
external parts
parts
parts
aluminum, coated carbon steel
Fluid
Fluid
Fluid Temperature
Temperature
Temperature Range
Range
Range
NOTICE
NOTICE
NOTICE
Temperature limits are based on mechanical stress only. Certain chemicals will further limit the fluid
operating temperature range. Stay within the temperature range of the most-restricted wetted component.
Operating at a fluid temperature that is too high or too low for the components of your pump may cause
equipment damage.
Fluid
Fluid
Fluid Temperature
Temperature
Temperature Range
Range
Range
Diaphragm/Ball
Diaphragm/Ball
Diaphragm/Ball Material
Material
Material
Fahrenheit
Fahrenheit
Fahrenheit
Celsius
Celsius
Celsius
Buna-N (BN)
10° to 180°F
-12° to 82°C
Geolast (GE)
–40° to 150°F
–40° to 66°C
Polychloroprene overmolded
diaphragm (CO) or
Polychloroprene check balls
(CW)
0° to 180°F
–18° to 82°C
2–Piece PTFE/Santoprene
Diaphragm
40° to 180°F
4° to 82°C
Santoprene® (SP)
-40° to 180°F
-40° to 82°C
California
California
California Proposition
Proposition
Proposition 65
65
65
CALIFORNIA
CALIFORNIA
CALIFORNIA RESIDENTS
RESIDENTS
RESIDENTS
WARNING:
WARNING:
WARNING: Cancer and reproductive harm — www.P65warnings.ca.gov.
334014D
21
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its
name to be free from defects in material and workmanship on the date of sale to the original purchaser for
use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a
period of five years from the date of sale, repair or replace any part of the equipment determined by Graco
to be defective. This warranty applies only when the equipment is installed, operated and maintained in
accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction,
damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper
maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall
Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment
with structures, accessories, equipment or materials not supplied by Graco, or the improper design,
manufacture, installation, operation or maintenance of structures, accessories, equipment or materials
not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an
authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco
will repair or replace free of charge any defective parts. The equipment will be returned to the original
purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material
or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of
parts, labor, and transportation.
THIS
THIS
THIS WARRANTY
WARRANTY
WARRANTY IS
IS
IS EXCLUSIVE,
EXCLUSIVE,
EXCLUSIVE, AND
AND
AND IS
IS
IS IN
IN
IN LIEU
LIEU
LIEU OF
OF
OF ANY
ANY
ANY OTHER
OTHER
OTHER WARRANTIES,
WARRANTIES,
WARRANTIES, EXPRESS
EXPRESS
EXPRESS OR
OR
OR
IMPLIED,
IMPLIED,
IMPLIED, INCLUDING
INCLUDING
INCLUDING BUT
BUT
BUT NOT
NOT
NOT LIMITED
LIMITED
LIMITED TO
TO
TO WARRANTY
WARRANTY
WARRANTY OF
OF
OF MERCHANTABILITY
MERCHANTABILITY
MERCHANTABILITY OR
OR
OR WARRANTY
WARRANTY
WARRANTY
OF
OF
OF FITNESS
FITNESS
FITNESS FOR
FOR
FOR AAA PARTICULAR
PARTICULAR
PARTICULAR PURPOSE.
PURPOSE.
PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above.
The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages
for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall
be available. Any action for breach of warranty must be brought within six (6) years of the date of sale..
GRACO
GRACO
GRACO MAKES
MAKES
MAKES NO
NO
NO WARRANTY,
WARRANTY,
WARRANTY, AND
AND
AND DISCLAIMS
DISCLAIMS
DISCLAIMS ALL
ALL
ALL IMPLIED
IMPLIED
IMPLIED WARRANTIES
WARRANTIES
WARRANTIES OF
OF
OF
MERCHANTABILITY
MERCHANTABILITY
MERCHANTABILITY AND
AND
AND FITNESS
FITNESS
FITNESS FOR
FOR
FOR AAA PARTICULAR
PARTICULAR
PARTICULAR PURPOSE,
PURPOSE,
PURPOSE, IN
IN
IN CONNECTION
CONNECTION
CONNECTION WITH
WITH
WITH
ACCESSORIES,
ACCESSORIES,
ACCESSORIES, EQUIPMENT,
EQUIPMENT,
EQUIPMENT, MATERIALS
MATERIALS
MATERIALS OR
OR
OR COMPONENTS
COMPONENTS
COMPONENTS SOLD
SOLD
SOLD BUT
BUT
BUT NOT
NOT
NOT MANUFACTURED
MANUFACTURED
MANUFACTURED BY
BY
BY
GRACO
GRACO
GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.),
are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable
assistance in making any claim for breach of these warranties..
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from
Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other
goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or
otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents,
notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or
indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du
présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés,
donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures
concernées.
Graco
Graco
Graco Information
Information
Information
For the latest information about Graco products, visit www.graco.com.
For patent information, see www.graco.com/patents.
To
To
To place
place
place an
an
an order,
order,
order, contact your Graco Distributor or call to identify the nearest distributor.
Phone:
Phone:
Phone: 612-623-6921 or
or
or Toll
Toll
Toll Free:
Free:
Free: 1-800-328-0211 Fax:
Fax:
Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original Instructions. This manual contains English. MM 334014
Graco
Graco
Graco Headquarters:
Headquarters:
Headquarters:
Minneapolis
International
International
International Offices:
Offices:
Offices: Belgium, China, Japan, Korea
GRACO
GRACO
GRACO INC.
INC.
INC. AND
AND
AND SUBSIDIARIES
SUBSIDIARIES
SUBSIDIARIES ••• P.O.
P.O.
P.O. BOX
BOX
BOX 1441
1441
1441 ••• MINNEAPOLIS
MINNEAPOLIS
MINNEAPOLIS MN
MN
MN 55440-1441
55440-1441
55440-1441 ••• USA
USA
USA
Copyright
Copyright
Copyright 2014,
2014,
2014, Graco
Graco
Graco Inc.
Inc.
Inc. All
All
All Graco
Graco
Graco manufacturing
manufacturing
manufacturing locations
locations
locations are
are
are registered
registered
registered toto
to ISO
ISO
ISO 9001.
9001.
9001.
www.graco.com
Revision D, March 2020