Provides lubricant flow and pressure to operate both single line and series progressive

automatic lubrication systems. For automatic lubrication systems only. For professional use only. Not approved for use in explosive atmospheres or hazardous (classified) locations. 3500 psi (24.1MPa, 241 bar) Maximum Working Pressure See page 3 for model information. Related Manuals 3A6932 Compact Dyna-Star Auto-Fill Shut Off Kit 3A6998 Compact Dyna-Star 35 lb (5 Gallon) Kit 3A7035 Compact Dyna-Star Pump Cable 333393 Fill Valve Important Safety Instructions Read all warnings and instructions in this manual and in your injector manual before using the equipment. Save these instructions.

Pump Model Selection Matrix......................................3

Warnings .....................................................................4 Installation ...................................................................6 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Pressure Relief Procedure. . . . . . . . . . . . . . . . . . 6 Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Series Parallel System ...................................7 Series Progressive System ............................7 Inlet and Outlet Components . . . . . . . . . . . . . . . . 7 Vent Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Pressure Relief Valve . . . . . . . . . . . . . . . . . . . . . 8 Motor Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Typical Installation: Series Parallel System . . . . . 9 Typical Installation: Series Progressive System 10 Typical Wiring: Series Parallel Systems. . . . . . . 11 Component Identification . . . . . . . . . . . . . . . . . . 12 Setup .........................................................................13 Fill the Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Fill Pumps with an Auto-Fill Shut Off (AFSO) . . 15 Refill the Tank: Pumps with an Auto-fill Shut Off (AFSO).....................................16 Fill Pumps Without an Auto-fill Shut Off (AFSO) 18 Refill the Tank: Pumps without an Auto-fill Shut Off..................................................18 Operation...................................................................20 Priming the System . . . . . . . . . . . . . . . . . . . . . . 20 Pump Operation Overview. . . . . . . . . . . . . . . . . 20 Series Parallel System .................................20 Series Progressive System ..........................20 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Level Monitoring. . . . . . . . . . . . . . . . . . . . . . . . . 21 Low Level Switch..........................................21 Level Transducer..........................................22 Pressure Switch............................................23 Pressure Transducer....................................23 Maintenance ............................................................. 24 Disassemble. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Reassemble . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Troubleshooting ........................................................ 38 Parts.......................................................................... 41 Related Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Dimensions: Pump with Tank ................................... 45 Dimensions: Stand Alone Pump ............................... 46 Dimensions: Stand Alone Pump ............................... 47 Mounting Dimensions: Stand Alone Pump ............... 48 Notes:........................................................................ 49 Technical Specifications ........................................... 50 California Proposition 65 . . . . . . . . . . . . . . . . . . 51 Graco Standard Warranty......................................... 52 Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Pump Model Selection Matrix

3A6941B 3 Pump Model Selection Matrix Pump models are made up of a six-digit part number. The first two digits are fixed alpha characters, while the remaining four are chosen from the matrix below. Select an item from each column to fill in the model number for ordering. Note: Some pump configurations are not available. Contact Graco customer service or your local Graco distributor for assistance. Pump Description Metering System Feedback Tank Tank Accessories 1 12L / 35# Bucket Length, 24 VDC 0 Series Progressive, no vent valve, no pressure reporting 0 No Tank, Bare Pump 0 No Tank, Bare Pump 2 20L Tank Length, 24 VDC 1 Vent Valve, No Pressure Reporting 1 12L Steel Tank with Follower Plate 1 Low Level Switch 2 Vent Valve, Pressure Switch 2 20L Steel Tank with Follower Plate 2 Level Transducer 3 Vent Valve, Pressure Transducer 3 35# Plastic Bucket Kit 3 Auto-Fill Shut Off and Low Level Switch 4 12 L Steel Tank with no Follower Plate 4 Auto-Fill Shut Off, Level Transducer 5 20 L Steel Tank with no Follower Plate C D 1 2 3 4 1 2 3 4

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-

tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable. WARNING FIRE AND EXPLOSION HAZARD When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources, such as cigarettes and portable electric lamps. • Ground all equipment in the work area. • Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline. • Do not plug or unplug power cords or turn lights on or off when flammable fumes are present. • Use only grounded hoses. • Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until you identify and correct the problem. • Keep a working fire extinguisher in the work area. SKIN INJECTION HAZARD High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Do not point dispensing device at anyone or at any part of the body. • Do not put your hand over the fluid outlet. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or servicing equipment. • Tighten all fluid connections before operating the equipment. • Check hoses and couplings daily. Replace worn or damaged parts immediately.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system com- ponent. See in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See in all equipment man- uals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request Safety Data Sheet (SDS) from distributor or retailer. • Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu- facturer’s replacement parts only. • Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards. • Make sure all equipment is rated and approved for the environment in which you are using it. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. MOVING PARTS HAZARD Moving parts can pinch, cut or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources. PERSONAL PROTECTIVE EQUIPMENT Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not limited to: • Protective eyewear, and hearing protection. • Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer. WARNING

To ground the pump: remove the ground screw (Z)

located on the back of the gear box and insert it through the eye of the ring terminal (W) at end of ground wire (Y). Fasten the ground screw (Z) back onto the pump and tighten securely. Connect the other end of the ground wire (Y) to a true earth ground (FIG. 1). To order a ground and wire clamp, order Part 222011. Pressure Relief Procedure Follow the Pressure Relief Procedure whenever you see this symbol. To relieve pressure in the system, use two wrenches working in opposite directions on the pump outlet fitting to slowly loosen the fitting only until no more lubricant or air is leaking from the fitting (FIG. 2). The equipment must be grounded to reduce the risk of static sparking. Static sparking can cause fumes to ignite or explode. Grounding provides an escape wire for the electric current. FIG. 1 Z W Y This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or servicing the equipment. FIG. 2

Note: Upper case letters used in the following

instructions refer to Typical Installation: Series Parallel System (FIG. 4), Typical Installation: Series Progressive System (FIG. 5), Typical Wiring: Series Parallel Systems (FIG. 6), and Component Identification (FIG. 7) diagrams starting on page 9. Securely mount and ground the unit before operation. 1. Mount the tank (K) on a sturdy, flat surface with user-provided bolts. Install so that the fill port (F) and the lubricant outlet connection (P or AC) are easily accessible after installation. 2. Connect the controller (F) (if used). 3. Connect a high pressure lubricant supply line (D) to the lubricant outlet connection (P or AC). 4. Connect all electrical connections. See Typical Wir- ing: Series Parallel Systems diagram, page 11. 5. Ground the system. See Grounding instructions, page 6. Pump The pump provides lubricant flow and pressure to oper- ate an automatic lubrication system. Series Parallel System The pump requires an electrical power supply and a timed signal from a lubrication controller (F). The pump provides lubricant flow and pressure to operate the injectors (E), and vents the injector system to reset the injectors. Series Progressive System The pump requires an electrical power supply and a timed signal from a lubrication controller (F). The pump provides lubrication flow and pressure to operate metering devices (AD). Inlet and Outlet Components Vent Valve The vent valve (L) reduces system pressure in Series Parallel system and resets the injectors. NOTICE Fuses (user supplied) are required on all models. To avoid equipment damage: • Never operate the pump without a fuse installed. • A fuse of the correct voltage and amperage must be installed in line with the power entry to the sys- tem. Graco recommends using a 10A time delay fuse. LIFTING HAZARD This equipment is heavy. Lifting or moving heavy equipment incorrectly can cause serious injury such as muscle strain or back injuries. To avoid injury: • Do not lift or move this equipment without assis- tance. • Always use a lifting device secured to the pump when moving or installing this equipment. See Notes:, page 49 for pump weight. The breather (J) vents the tank to the atmosphere. If it is plugged the tank will over-pressurize and rupture. Be sure the breather is not plugged before filling the pump. COMPONENT RUPTURE HAZARD The maximum working pressure of the inlet and outlet components in the system vary. Over-pressurizing an inlet or outlet can cause components to rupture, seri- ous injury such as skin injection or injury from splash- ing fluid. To reduce the risk of component rupture: • Be sure to know the maximum working pressure of each inlet and outlet component in the system. • Never exceed the maximum working pressure of the inlet and outlet components.

Pressure Relief Valve

The pump design includes a self-contained pressure relief valve (N). When needed, the valve relieves pressure back into the pump tank (K). Motor Details The pump (B) is driven by a 24 V DC brushless motor (1) with a built-in controller. The motor LED flashes multiple times during start up and stays on during operation. Refer to Troubleshooting, page 38 for more information. FIG. 3 B 1

Typical Installation: Series Parallel System

Key: A Lubricant output connection* B Pump C Ignition switch* D High-pressure lubricant supply lines* E Injector banks* F Lubrication controller* G Fill port H Overflow port K Tank L Vent Valve NN Bearing* *User provided FIG. 4 A B C D E F G H K NN L

Typical Installation: Series Progressive System

Key: A Lubricant output connection* B Pump C Ignition switch* D High-pressure lubricant supply lines* F Lubrication controller* G Fill port H Overflow port K Tank NN Bearing* AD Metering device* *User provided FIG. 5 A B D NN F AD K H G C NN NN NN

Fill port and cover

H Overflow port J Breather K Tank L Vent valve M Motor N Pressure relief valve P Outlet (3/8 in. NPT) R Gear box S Low level switch or level transducer T Pressure switch or transducer U Lift ring V Auto-fill shut off (AFSO) (optional) Y Follower plate Z Tube-in-tube AB Plug to check venting / pressure relief AC Refill vent plug or refill pressure relief AD Outlet (1/4 in. NPT) (optional) FIG. 7 AB P L V M N T S U J H Z Y K G AC R B AD U V

Fill the Tank

The fill port is used for filling and refilling the tank for pumps with or without auto-fill. Fill the tank through the fill port (FIG. 8). Auto-Fill Shut Off: When grease is added, the follower plate is pushed upward and closes the flow path. (FIG. 9). Non-Auto-Fill Shut Off: When grease is added, the follower plate is pushed upward. When the tank is full, the grease will begin to flow out of the overflow port (H). FIG. 8: Fill Port FIG. 9 Follower Plate

Always fill the pump through the fill port to expel any air

from the tube-in-tube (FIG. 10). Always use the follower plate to prime the pump for grease NLGI 1, NLGI 2, and for cold pumping applications. Note: The auto-fill shut off requires using a follower plate. The follower plate should not be used with oil and low viscous grease applications. The follower plate may sink in these lubricants and block the pump inlet. FIG. 10 Tube-in-Tube

Fill Pumps with an Auto-Fill Shut Off (AFSO)

Note: The remote filling station pump stalls (dead-heads) when the tank is full. If the pump does not stall (dead-head) there is a leak in the system. Key: AA Remote fill station pump* BB Remote fill station tank* CC Filter* DD Pressure relief line* EE Fill valve* [Graco Part No. 77X542) FF Fill valve pressure relief knob* [Part of Fill Valve 77X542] GG Refilling line* HH Instruction label* [Included with Fill Valve 77X542] JJ Supply hose* K Tank V Auto-Fill Shut Off V1 Auto-Fill Shut Off valve pin Y Follower plate *User supplied NOTICE Never allow the pump to run dry of the fluid being pumped to avoid pump damage. NOTICE If the refilling pump runs dry it pumps air into the pump and may cause damage. Always make sure that there is enough lubricant in the refilling pump station. FIG. 11 AA BB CC GG HH EE FF DD JJ V K Y V1

The auto-fill shut off (V) is used to refill the grease tank

(K) in an automatic lubrication system. When the grease level in the tank is full, the auto-fill shut off automatically ends the filling operation. Always fill the tank (K) to full during refilling. As grease is added to the tank (K), the follower plate (Y) is pushed to the top of the tank (K) and pushes up the valve pin (V1) which closes the inlet fluid path. Pin (V2) pops up when the tank is full (FIG. 12). When the fluid refilling path closes, the refilling line (GG) pressurizes and brings the remote fill station pump (AA) to a pressurized stall condition. Note: The operator must monitor the system during fill- ing of the tank to prevent any accidental fluid overflow. Refill the Tank: Pumps with an Auto-fill Shut Off (AFSO) 1. Pull and hold the fill valve pressure relief knob (FF) long enough to relieve line pressure between the fill valve (EE) and the auto-fill shut off valve (V). 2. Verify the auto-fill shut off pin (V2) is down, indicat- ing it is reset (FIG. 13). 3. Remove the dust cover (DC) from the fill coupler (FC) on the fill valve (EE) (FIG. 14). FIG. 12 The breather (J) vents the tank to the atmosphere. If it is plugged the tank will over-pressurize and rupture. Be sure the breather is not plugged before filling the pump. V2 FIG. 13 FIG. 14 V2 Pin Down EE DC FC FF

Connect the supply hose (JJ) between the remote

fill station pump (AA) and fill coupler (FC) port marked with an “I” (FIG. 14). 5. Start the remote fill station pump (AA). 6. When the tank (K) is filled: • The remote fill station pump (AA) stalls (dead-heads), • the auto-fill shut off pin (v2) pops up as shown in FIG. 15, • The pressure gauge needle rises to the fill pump’s set pressure. Note: If the pump does not stall (dead-head) there is a leak in the system. NO7. Turn off the remote fill station pump (AA). 8. Pull and hold the fill valve pressure relief knob (FF) long enough to relieve line pressure between fill valve (EE) and Auto-fill Shut Off Valve (V) and between remote fill station pump (AA) and fill valve (EE). Note: The length of time it takes to vent the pressure varies depending on the system design and installation. In some installations it may be necessary to repeat Step 8 to ensure pressure is relieved. 9. Disconnect the supply hose (JJ) from the fill coupler (FC) (FIG. 14). 10. Replace the dust cover (DC) over the fill coupler (FC). NOTICE To prevent damage to the unit: • Check breather (J) vent for proper operation before filling the tank (K). • Do not fill tank (K) beyond the overflow port (H). • Do not use the breather (J) as a port to fill the tank. FIG. 15 V2

Fill Pumps Without an Auto-fill Shut Off (AFSO)

Key: AA Remote fill station pump* BB Remote fill station tank* CC Filter* DC Dust cap G Fill port JJ Supply hose* H Overflow port Y Follower plate *User supplied Refill the Tank: Pumps without an Auto-fill Shut Off FIG. 16 BB AA CC JJ DC G H Y Do not insert your finger into the overflow port while filling a tank equipped with a follower plate. Injury or amputation could result. COMPONENT RUPTURE HAZARD The maximum working pressure of each component in the system may not be the same. To reduce the risk of over pressurizing any component in the system, know the maximum working pressure of each component. Never exceed the maximum working pressure of the lowest rated component in the system. Over pressurizing can result in rupture, and serious injury from skin injection or splashing fluids. Regulate pressure to the pump so that no fluid line, component or accessory is over pressurized.

Connect the lubricant supply hose (JJ) from the

remote filling station pump (AA) to the fill port (G) (FIG. 17). 2. Slowly turn on the supply lubricant until the level of lubricant reaches the overflow port (H). When the tank (K) is full (or overfilled) grease will flow out of the overflow port. (H). Note: For pump tanks (K) with a follower plate (Y), fill the tank until the follower plate reaches the overflow port (H) and grease flows out. FIG. 17 The breather (J) vents the tank to the atmosphere. If it is plugged the tank will over-pressurize and rupture. Be sure the breather is not plugged before filling the pump. NOTICE To prevent damage to the unit: • Check breather (J) vent for proper operation before filling the tank (K). • Do not fill tank (K) beyond the overflow port (H). • Do not use the breather (J) as a port to fill the tank. G

Note: Upper case letters used in the following

instructions refer to Component Identification, Typical Installation: Series Parallel System and Typical Installation: Series Progressive System diagrams starting on page 9. The unit must be securely mounted and grounded before operation. Priming the System 1. After the tank (K) is completely filled, remove the high pressure lubricant supply line (D) from the out- let. 2. Connect power to the pump (B). 3. Start the pump (B) and run until all of the air has been expelled and fluid flow is continuous (FIG. 18). 4. Reconnect the high pressure lubricant supply line (D) to the outlet. Pump Operation Overview Series Parallel System 1. At the start of the cycle, the lubrication controller (F) initiates a signal that closes the vent valve (L) and starts the pump (B). 2. The pump (B) builds pressure in the supply lines (D) until all the injectors (E) actuate. Then the pressure switch (T) sends a signal to the lubrication controller (F) to end the cycle. 3. The lubrication controller (F) terminates the signal to the pump (B) and power to the vent valve (L). 4. The vent valve (L) opens. 5. Pressure is relieved in the supply lines (D), back into the tank (K), and resets all of the injectors (E). Series Progressive System 1. At the start of the cycle, the lubrication controller (F) initiates a signal to start the pump (B). 2. The pump (B) supplies lubricant and pressure to the metering devices (AD). When the metering devices are active, they carry lubricant to the lube points. 3. Continuous lubrication is provided during pump operation. 4. To control lubrication based upon number of cycles, a cycle switch can be added to the metering devices. Shutdown For normal shut down, disconnect power to the lubricator controller (F) and to the pump. FIG. 18

Low Level Switch

The low level switch (S) (FIG. 19) indicates a fault when the follower plate (Y) reaches the factory set distance from the bottom of the tank. The fault activates when the remaining grease level is approximately 10 percent. FIG. 19 Low Level Switch NOTICE The pump (B) should not be run without grease because air will be introduced into the system and could cause damage. Output type: 1 switching output, PNP NO Operating voltage: 10 - 30 VDC Current: 200mA Connection type: M12x1, 4-pin FIG. 20

The level transducer (S) (FIG. 21) is used for continuous

level monitoring. It indicates a fault when the follower plate (Y) reaches the factory set distance from the bottom of the tank. The fault activates when the remaining grease level is approximately 10 percent. Light Indicator NOTICE The pump (B) should not be run without grease, or air will be introduced into the system and could cause damage. Output type: 1 analog output 0 - 10V Operating voltage: 10 - 30 VDC Current: 200mA Connection type: M12x1, 4 pin Normal: Green Low-Level: Yellow Error: Red FIG. 21

The pressure switch (T) is factory set to 3000 psi (20.7

MPa, 207 bar) (FIG. 22). When the pressure in the system reaches 3000 psi, the pressure switch (T) closes. Pressure Transducer The pressure transducer (T) is used for continuous pressure monitoring. FIG. 22 Output type: 1 Switching output NO Operating voltage: 24VDC Current: 5A Connection type: Packard Metri-Pack 150 Series Preset pressure: 3000 psi Output type: Analog 1- 5V Operating voltage: 8 - 32V Connection type: Packard Metri-Pack 150 Series Pressure range: 0-5000 psi FIG. 23

Relieve pressure, following the Pressure Relief

Procedure, page 6. 2. Disconnect the power to the system. 3. Loosen and remove the four bolts (3) holding the motor (1) to the pump, then remove the motor (1) and the o-ring (2) (FIG. 24). 4. Loosen and remove the four bolts and four washers holding the pump to the tank (41) with a 5 mm Allen wrench (FIG. 25). 5. Pull the pump out of the tank (41). 6. Remove the pressure relief valve cartridge (5) (FIG. 26). 7. Remove the two bolts (6) and two nuts (not shown) from the protection cover (8) (FIG. 27). 8. Remove the protection cover (8). FIG. 24 FIG. 25 1 2 3 41 47 48 FIG. 26 FIG. 27 5 8 6

Loosen the retaining nut (9) with a tube wrench (FIG.

28). 10. Pull up on the lower section to separate from the gear head (4) (FIG. 29). 11. Remove the tube-in-tube (10) with a pipe wrench. Verify the o-ring (11) is on the tube-in-tube (10) (FIG. 30). 12. Push on the end of the pump rod (27) to gain access to the cross-hole located at the end of the shovel rod (FIG. 31 and FIG. 32). FIG. 28 FIG. 29 9 4 FIG. 30 FIG. 31 10 11

13. Place an Allen wrench or similar tool through the

slot of the shovel tube (13) and into the exposed cross-hole to keep the shovel rod (17) steady (FIG. 32). 14. Loosen and remove the shovel piston (12) with a 10 mm socket wrench (FIG. 32). 15. Place the pump tube into a vise, protected by a cloth, and tighten to steady the pump lower tube (23) (FIG. 33). 16. Loosen the shovel tube (13) using a pipe wrench and remove it from the pump lower tube (23) (FIG. 33). 17. Remove the two back up rings (14) and the o-ring (15) from the shovel tube (13) (FIG. 33) 18. Loosen and remove the pump lower tube (23) with a pipe wrench and remove the o-ring (24) from the pump lower tube (23) (FIG. 34). 19. Remove the shuttle valve (16) (FIG. 35). 20. Remove the spacer (18) (FIG. 35). FIG. 32 FIG. 33 13 17 12 13 23 14 15 FIG. 34 FIG. 35 23 24 18 16

21. Remove the piston bushing (19) (FIG. 36).

22. Remove the two (2) backup rings (20) and the o-ring (21) from the piston bushing (19) (FIG. 36). 23. Remove the shovel rod (17) from the pump piston (25) (FIG. 37). 24. Remove the pump piston (25) from the pump rod (27). Note: Remove the ball (22) from the pump piston (25) (FIG. 38 and FIG. 39). FIG. 36 FIG. 37 19 20 21 17 25 FIG. 38 FIG. 39 25 27 25 22

25. Loosen and remove the extension tube (26) from

the top housing. Remove two backup rings (14) and the o-ring (15) (FIG. 40). 26. Pull out the pump rod (FIG. 41). 27. Remove the retaining nut (9) located on the upper housing (FIG. 42). 28. Remove the outer o-ring (28) from the retaining nut (FIG. 43). 29. Remove the throat screw (29) to get to the inner o-ring (30) (FIG. 43). 30. Remove the bronze washer (31) from the pump housing (FIG. 43). 31. Remove the throat seal (32) (u-cup) (FIG. 43). FIG. 40 FIG. 41 26 14 15 27 FIG. 42 FIG. 43 9 28 30 29 31 32

Place throat seal (32) (u-cup) into the pump

housing, lips downward (FIG. 45). 2. Place the bronze washer (31) on top of the throat seal (32) (u-cup) (FIG. 45). 3. Replace the inner o-ring (30) from the retaining nut (9) with a new o-ring and grease lightly. (FIG. 46). 4. Replace the outer o-ring (28) from the retaining nut (9) with a new o-ring and grease lightly (FIG. 46). 5. Place the throat screw (29) into the retaining nut (9) using an Allen wrench and tighten (torque 16 ft-lb/ 21.7 N•m) 6. Grease the o-ring (28) and place the retaining nut (9) into the pump housing and tighten slightly (FIG. 48). FIG. 45 FIG. 46 32 31 30 28 FIG. 47 FIG. 48 29 9 9 28

Apply a light coating of grease to the pump rod (27)

and push it into the pump housing through the hole in the retaining nut (9) (FIG. 49). 8. Replace the two back-up rings (14) and o-ring (15) with new back-up rings and o-ring and grease lightly (FIG. 50). 9. Place the extension tube (26) over the pump rod and tighten to pump housing (torque 40 ft-lb/54.2 N•m) (FIG. 50). 10. Place the ball (22) back into the pump piston (25) (FIG. 51). 11. Apply medium strength thread locking compound on the threads of the pump rod (27). FIG. 49 9 27 FIG. 50 FIG. 51 15 26 14 Pump Housing 22 25

12. Place the pump piston (25) on the end of the pump

rod (27) and tighten using wrenches (torque 10 ft-lb/13.6 N•m) (FIG. 52 and FIG. 53). 13. Replace the two back-up rings (20) and o-ring (21) with new back-up rings and o-ring and grease lightly (FIG. 54). 14. Place the piston busing (19) into the pump lower tube (23) until seated (FIG. 54). 15. Place the shovel rod (17) into the pump piston (25) groove (FIG. 55). FIG. 52 FIG. 53 25 27 25 27 FIG. 54 FIG. 55 21 20 23 19 25 17

16. Replace and lightly grease the o-ring (24) on the

lower pump tube (23) (FIG. 56). 17. Slide the pump lower tube (23) over the pump rod (27) and connect to the extension tube (26) (torque 40 ft-lb/54.2 N•m) (FIG. 56). 18. Place the spacer (18) into the pump lower tube (23) until seated (FIG. 57). 19. Attach the shuttle valve (16) to the shovel rod (17), with the notch upward (FIG. 57). 20. Replace the two shovel tube (13) back-up rings (14) and the o-ring (15) and grease lightly (FIG. 58). 21. Place the shovel tube (13) into the pump lower tube (23) and tighten (torque 40 ft-lb/54.2 N•m) (FIG. 58). 22. Push pump rod (27) down to move the shovel rod (17) down to access the cross-hole (FIG. 59). 23. Place an Allen wrench or similar tool through the slot of the shovel tube (13) and into the exposed cross-hole to keep the shovel rod (17) steady (FIG. 59). 24. Tighten the shovel piston (12) with a 10 mm socket wrench (torque 3-4 ft-lb/4.1-5.4 N•m) (FIG. 59). FIG. 56 FIG. 57 24 23 26 27 23 18 17 16 FIG. 58 FIG. 59 25 13 15 14 23 13 12 17 Cross- hole

25. Replace the o-ring (11) and grease lightly (FIG. 60).

26. Slide the tube-in-tube (10) over the assembly and up to the pump housing. Tighten the flange (torque 40 ft-lb/54.2 N•m) (FIG. 60 and FIG. 61). 27. Fit the pump assembly into the gear head (4). The retaining nut (9) can be loosened to increase the gap. Line up the pump rod (27) with the cut out and slide into place (FIG. 62). Note: Leave the retaining nut loose (9). 28. Place two bolts (6) into the pump assembly to hold the gear head and pump assembly in place and tighten slightly the two nuts (7) (FIG. 63). FIG. 60 FIG. 61 4 10 11 9 4 9 Flange FIG. 62 FIG. 63 4 27 9 Pump Assembly 6 7

29. Tighten the retaining nut (9) with a wrench (torque

30 ft-lb/40.1 N•m) to secure (FIG. 64). 30. Remove the two bolts (6) and two nuts (7) (FIG. 65). 31. Place the protection cover (8) in place and secure with bolts (6) and nuts (7) (not shown) (FIG. 66). 32. Place the o-ring (2) and attach the motor (1) to the pump using the four bolts (3) (torque 11 ft-lb/14.9 N•m) (FIG. 67). FIG. 64 FIG. 65 9 6 FIG. 66 FIG. 67 8 6 2 3 1

33. Place the o-ring onto the check valve, and then

place into the pump outlet and tighten (torque 16 ft-lb/21.7 N•m) (FIG. 68). There is air located between the pump tube and the tube-in-tube. Remove this air by filling it with grease to prime the pump. If this is not done, the pump may lose priming during operation. 34. Connect the refill pump to the fill coupler (FIG. 69). FIG. 68 37 FIG. 69 Fill Coupler Refill Pump Refill Pump Refill Filter Fill Coupler Pump Tube-in-tube Pump Tube

35. Run the refill pump until grease comes out of the

bottom of the tube-in-tube (FIG. 70). 36. Put the pump back into the tank (41) through the cover and the gasket (FIG. 71). 37. Place the four bolts and four washers into place and tighten with a 5 mm Allen wrench (torque 16 ft-lb/21.7 N•m) (FIG. 71). 38. Place the pressure relief valve cartridge (5) and tighten (torque 8 ft-lb/10.8 N•m) (FIG. 72). 39. Reconnect the power to the system. FIG. 70 1 FIG. 71 FIG. 72 41 5

Follow Pressure Relief Procedure, page 6, before

checking or repairing the pump. 2. Check all possible problems and causes before disassembling the pump. Problem Cause Solution Pump is not powering ON. The red LED on the motor is not ON. Wiring is incorrect Polarity is wrong Loose wire(s) Check and verify that the wire connections are tight. Check and correct polarity. Fuse is: Wrong amperage Not in place or missing Faulty Check the fuse rating and replace with new or correct amperage fuse. The lubrication controller is in OFF mode. Set the lubrication controller to the correct lube cycle.

Pump in not powering ON.

The red LED on the motor is blinking. 2 blinks indicate: over current pump is jammed Remove the pump and repair with new pump element parts. 2 blinks indicate: over current pump is jammed The grease is too thick or the ambient temperature is too cold to pump. Replace the grease if it is too thick or the ambient temperature is too cold to pump the grease. Replace grease with correct temperature rated grease. 3 blinks indicate the motor is losing the signal. Verify that the wire connections are tight. Correct polarity. Replace the motor. 4 blinks indicate low voltage. Check voltage and correct as needed. 5 blinks indicate high voltage. Check voltage and correct as needed. 6 blinks indicate an over temperature motor windings. High duty cycle, set to 50% duty cycle. Remove the pump and repair with new pump element parts, if the pump is jammed, Replace grease with correct temperature rated grease. 7 blinks indicate over temperature on motor driver. High duty cycle, set to 50% duty cycle. Remove the pump and repair with new pump element parts, if the pump is jammed, Replace grease with correct temperature rated grease. The Pump is cycling, but there is no lubricant output from the outlet The lubricant level in the tank is too low. Refill the tank. Problem Cause Solution

The Pump is cycling, but there is no

lubricant output from the outlet. The Pump lost priming/pump is cavitating. Tank was not refilled through the fill port. Air in the tube-in-tube was pushed into the grease tank. Connect the refill pump to the fill port and fill tank to remove any air. Grease inside of the tank is not moving to the pump shovel tube. Install follower plate to help distribute grease during pump operation. Follower plate is not moving and is stuck inside of the tank. Inspect and replace follower plate, if necessary. Follower plate is sunk into the tank. The grease viscosity is too low. Remove the follower plate. The pump element parts are worn or damaged. Replace with new pump element parts. Pump is cycling, there is output of fluid at the outlet, but pump pressure is not building. Pump element parts are worn or damaged. Replace with new pump element parts. Vent valve is not energized in the series parallel system. Check the wiring and correct. Vent valve is energized but not closing (leaky vent valve). Open the inspection plug (AB), page 12, to confirm that the vent valve is not closing (leaky). Replace the vent valve. Pressure relief is leaky. Open the inspection plug (AB), page 12, to confirm pressure relief is leaky. Replace pressure relief valve. Problem Cause Solution

Parts 3A6941B 41 Parts 44 38 37 35 33 33 32 31 29 28 30 9 5 40 1 3 2 10 4 7 6 8 11 22 27 25 12 13 14 17 16 19 18 20 21 23 24 47 48 15 26

25R009 Pressure relief valve

1 6  Bolt 2 7  Nut 2 8  Protection cover 1 9 Retaining nut 1 10  Tube-in-tube 1 11  O-ring 1 12 Shovel piston 1 13 Shovel tube 1 14  Back up rings 4 15  O-ring 2 16 † Shuttle valve 1 17 † Shovel rod 1 18 Spacer 1 19 † Piston bushing 1 20  Back up rings 2 21  O-rings 1 22 † Steel ball 1 23 Pump lower tube 1 24  O-ring 1 25 † Pump piston 1 26 Pump extension tube 1 27 Pump rod 1 28  O-ring 1 29 Throat screw 1 30  O-ring 1 31  Washer 1 32  U-cup seal 1 33 25P686 Auto-fill shut off 1 33 25P685 Auto-fill shut off plug 1 35 131711 Pressure switch 1 35 131674 Pressure transducer 1 35 567251 Plug 37 25P689 Check valve assembly 1 38 25P690 Vent valve (Series Parallel System) 1 38 25R023 Vent valve plug (Series Progressive System) 1 40 Refill adapter 1 41 25E166 Tank assembly with follower plate 12 Liter, low level switch for AFSO models 1 25E323 Tank assembly with follower plate 12 Liter, level transducer for AFSO models 1 25E324 Tank assembly with follower plate 20 Liter, low level switch for AFSO models 1 25E167 Tank assembly with follower plate 20 Liter, level transducer for AFSO models 1 58 25R124 Tank assembly 12 Liter, low level switch, no follower plate, overflow tube 1 25R122 Tank assembly 12 Liter, level transducer, no follower plate, overflow tube 1 25R125 Tank assembly 20Liter, low level switch, no follower plate, overflow tube 25R123 Tank assembly 20 Liter, level transducer, no follower plate, overflow tube 59 25R118 Tank assembly with follower plate, 12 Liter, level transducer, overflow tube 25R119 Tank assembly with follower plate 20 Liter, level transducer, overflow tube 25R120 Tank assembly with follower plate 12 Liter, low level switch, overflow tube 25R121 Tank assembly with follower plate 20 Liter, low level switch, overflow tube 4225P693 Follower plate assembly 1 4325P695 Low Level Switch Kit 12 Liter 1 25P697 Low Level Switch Kit 20 Liter 1 25P694 Level Transducer Kit 12 Liter 1 25P969 Level Transducer Kit 20 Liter 1 44 25P683 Front cover black with screws and label 1 45130766 Warning label English (not shown) 1 46130899 Warning Label French and Spanish (not shown) 1 47  M6 x 20 bolts 4 48  M6 Lock washers 4 49  Pump gasket 1 50  Breather 1 51  Overflow port plug 1 52 ‡ Overflow tube 1 Ref. Part Description Qty.

Replacement safety labels, tags, and cards are

available at no cost. Related Kits 53  Eye bolt 1 54  Tank cover 1 55  M8 x 32 bolts 5 56  M8 nut 5 57  M8 washer 5 Ref. Part Description Qty. Ref Part No. Description  25P688 Motor Parts Kit  25P691 Tube-in-Tube 12 Liter Kit  25P692 Tube-in-Tube 20 Liter Kit  25P684 Protection Cover Kit † 25P945 Pump Element Kit  25P946 Pump Seal Kit  Also included with 41, 58, 59  Also included with 41 ‡ Also included with 58, 59  Also included with 41, 59

Dimensions: Pump with Tank

3A6941B 45 Dimensions: Pump with Tank Ref 12 Liter 20 Liter inches mm inches mm A 24.53 623.1 30.48 774.2 B 14.43 366.5 20.38 517.7 C 11.48 291.6 11.48 291.6 D 13.9 353.1 13.9 353.1

Dimensions: Stand Alone Pump

46 3A6941B Dimensions: Stand Alone Pump Ref 12 Liter 20 Liter inches mm inches mm A 13.92 353.57 19.89 505.21 B 10.1 256.54 10.1 256.54 C 9.8 248.92 9.8 248.92 D 1.5 38.1 1.5 38.1 M 0.8 20.32 0.8 20.32 Top View

Dimensions: Stand Alone Pump

3A6941B 47 Top View Dimensions: Stand Alone Pump Ref 12 Liter/20 Liter inches mm E 7.63 193.8 F 2.54 64.52 G 3.26 82.83 H 6.79 172.47 K 10.18 258.6 Top View Bottom View

*Output of the pump depends upon the fluid being used, the output pressure, the ambient temperature, and other envi-

ronmental factors. Compact Dyna-Star Electric Pump US Metric Maximum Working Pressure 3500 psi 24.1 MPa, 241 bar Pressure switch factory set: 3000 psi 20.7 MPA, 207 bar Pressure relief valve factory set: 4000 psi 27.6 MPa, 276 bar Operating Temperature -40° F to 149° F -40° C to 65° C IP Rating IP69K Electrical Requirements Voltage 24 VDC Input Voltage Range 18-30 VDC Maximum Current 10 A Peak Operating Current 15 A Peak Power 188 Watts Maximum Delivery* 4.5 in3/min 74 cc/min Grease Tank Capacity (Graco Supplied) 12 or 20 Liters Inlet/Outlet Size Tank Fill Port Quick Coupler Overflow Port 1/2 in. npt Fluid Outlet 3/8 in. npt Materials of Construction Pump steel, buna-N, acetal, lubrithane, polyurethane, brass, polyehylene Tank steel, buna-N, rubber, aluminum Weight - Without Grease in the Tank 12 Liter 66 lb 29.9 kg 20 Liter 73 lb 33.1 kg Weight - Pump Only 12 Liter 27 lb 12.2 kg 20 Liter 30 lb 13.6 kg Low Level Switch/Low Level Transducer Operating Voltage 0 - 30 VDC Output Type 1 Switching output, PNP NO 1 Analog output 0 - 10V (low level transducer) Connection Type M12X1, 4-pin Pressure Switch/Pressure Transducer Operating Voltage 24 VDC Output Type 1 Switching output, NO 1 Analog output 1 - 5V (pressure transducer) Connection Type Packard Metri-Pack 150 Series

California Proposition 65

WARNING: This product can expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65warnings.ca.gov.

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM 3A6941 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA Copyright 2019, Graco Inc. All Graco manufacturing locations are registered to ISO 9001. www.graco.com Revision B, December 2019 Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. Graco Information For the latest information about Graco products, visit www.graco.com. For patent information, see www.graco.com/patents. TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590