Graco Compact Dyna-Star 3A6941B Instructions Manual
Read Online
Read the Graco Compact Dyna-Star 3A6941B Instructions Manual online using the built-in PDF viewer.
Text of the manual
Provides lubricant flow and pressure to operate both single line and series progressive
automatic lubrication systems. For automatic lubrication systems only. For professional
use only.
Not approved for use in explosive atmospheres or hazardous (classified) locations.
3500 psi (24.1MPa, 241 bar) Maximum Working
Pressure
See page 3 for model information.
Related Manuals
3A6932 Compact Dyna-Star Auto-Fill Shut Off Kit
3A6998 Compact Dyna-Star 35 lb (5 Gallon) Kit
3A7035 Compact Dyna-Star Pump Cable
333393 Fill Valve
Important Safety
Instructions
Read all warnings and instructions
in this manual and in your injector
manual before using the
equipment. Save these
instructions.
Pump Model Selection Matrix......................................3
Warnings .....................................................................4
Installation ...................................................................6
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Pressure Relief Procedure. . . . . . . . . . . . . . . . . . 6
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Series Parallel System ...................................7
Series Progressive System ............................7
Inlet and Outlet Components . . . . . . . . . . . . . . . . 7
Vent Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pressure Relief Valve . . . . . . . . . . . . . . . . . . . . . 8
Motor Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Typical Installation: Series Parallel System . . . . . 9
Typical Installation: Series Progressive System 10
Typical Wiring: Series Parallel Systems. . . . . . . 11
Component Identification . . . . . . . . . . . . . . . . . . 12
Setup .........................................................................13
Fill the Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Fill Pumps with an Auto-Fill Shut Off (AFSO) . . 15
Refill the Tank: Pumps with an Auto-fill
Shut Off (AFSO).....................................16
Fill Pumps Without an Auto-fill Shut Off (AFSO) 18
Refill the Tank: Pumps without an Auto-fill
Shut Off..................................................18
Operation...................................................................20
Priming the System . . . . . . . . . . . . . . . . . . . . . . 20
Pump Operation Overview. . . . . . . . . . . . . . . . . 20
Series Parallel System .................................20
Series Progressive System ..........................20
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Level Monitoring. . . . . . . . . . . . . . . . . . . . . . . . . 21
Low Level Switch..........................................21
Level Transducer..........................................22
Pressure Switch............................................23
Pressure Transducer....................................23
Maintenance ............................................................. 24
Disassemble. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Reassemble . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Troubleshooting ........................................................ 38
Parts.......................................................................... 41
Related Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Dimensions: Pump with Tank ................................... 45
Dimensions: Stand Alone Pump ............................... 46
Dimensions: Stand Alone Pump ............................... 47
Mounting Dimensions: Stand Alone Pump ............... 48
Notes:........................................................................ 49
Technical Specifications ........................................... 50
California Proposition 65 . . . . . . . . . . . . . . . . . . 51
Graco Standard Warranty......................................... 52
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Pump Model Selection Matrix
3A6941B
3
Pump Model Selection Matrix
Pump models are made up of a six-digit part number. The first two digits are fixed alpha characters, while the
remaining four are chosen from the matrix below. Select an item from each column to fill in the model number for
ordering.
Note: Some pump configurations are not available. Contact Graco customer service or your local Graco distributor for
assistance.
Pump Description
Metering System Feedback
Tank
Tank Accessories
1
12L / 35# Bucket
Length, 24 VDC
0
Series Progressive, no
vent valve, no pressure
reporting
0
No Tank,
Bare Pump
0
No Tank,
Bare Pump
2
20L Tank Length,
24 VDC
1
Vent Valve, No Pressure
Reporting
1
12L Steel Tank
with Follower
Plate
1
Low Level Switch
2
Vent Valve, Pressure
Switch
2
20L Steel Tank
with Follower
Plate
2
Level Transducer
3
Vent Valve, Pressure
Transducer
3
35# Plastic
Bucket Kit
3
Auto-Fill Shut Off and
Low Level Switch
4
12 L Steel Tank
with no Follower
Plate
4
Auto-Fill Shut Off, Level
Transducer
5
20 L Steel Tank
with no Follower
Plate
C
D
1
2
3
4
1
2
3
4
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where
applicable.
WARNING
FIRE AND EXPLOSION HAZARD
When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:
•
Use equipment only in well ventilated area.
•
Eliminate all ignition sources, such as cigarettes and portable electric lamps.
•
Ground all equipment in the work area.
•
Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.
•
Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
•
Use only grounded hoses.
•
Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until
you identify and correct the problem.
•
Keep a working fire extinguisher in the work area.
SKIN INJECTION HAZARD
High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This
may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical
treatment.
•
Do not point dispensing device at anyone or at any part of the body.
•
Do not put your hand over the fluid outlet.
•
Do not stop or deflect leaks with your hand, body, glove, or rag.
•
Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or
servicing equipment.
•
Tighten all fluid connections before operating the equipment.
•
Check hoses and couplings daily. Replace worn or damaged parts immediately.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
•
Do not exceed the maximum working pressure or temperature rating of the lowest rated system com-
ponent. See in all equipment manuals.
•
Use fluids and solvents that are compatible with equipment wetted parts. See in all equipment man-
uals. Read fluid and solvent manufacturer’s warnings. For complete information about your material,
request Safety Data Sheet (SDS) from distributor or retailer.
•
Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
•
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.
•
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create
safety hazards.
•
Make sure all equipment is rated and approved for the environment in which you are using it.
•
Use equipment only for its intended purpose. Call your distributor for information.
•
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
•
Do not kink or over bend hoses or use hoses to pull equipment.
•
Keep children and animals away from work area.
•
Comply with all applicable safety regulations.
MOVING PARTS HAZARD
Moving parts can pinch, cut or amputate fingers and other body parts.
•
Keep clear of moving parts.
•
Do not operate equipment with protective guards or covers removed.
•
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure and disconnect all power sources.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the work area to help prevent serious injury, including
eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not
limited to:
•
Protective eyewear, and hearing protection.
•
Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.
WARNING
To ground the pump: remove the ground screw (Z)
located on the back of the gear box and insert it through
the eye of the ring terminal (W) at end of ground wire
(Y). Fasten the ground screw (Z) back onto the pump
and tighten securely. Connect the other end of the
ground wire (Y) to a true earth ground (FIG. 1). To order
a ground and wire clamp, order Part 222011.
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
To relieve pressure in the system, use two wrenches
working in opposite directions on the pump outlet fitting
to slowly loosen the fitting only until no more lubricant or
air is leaking from the fitting (FIG. 2).
The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.
FIG. 1
Z
W
Y
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop dispensing and before
cleaning, checking, or servicing the equipment.
FIG. 2
Note: Upper case letters used in the following
instructions refer to Typical Installation: Series
Parallel System (FIG. 4), Typical Installation: Series
Progressive System (FIG. 5), Typical Wiring: Series
Parallel Systems (FIG. 6), and Component
Identification (FIG. 7) diagrams starting on page 9.
Securely mount and ground the unit before operation.
1.
Mount the tank (K) on a sturdy, flat surface with
user-provided bolts. Install so that the fill port (F)
and the lubricant outlet connection (P or AC) are
easily accessible after installation.
2.
Connect the controller (F) (if used).
3.
Connect a high pressure lubricant supply line (D) to
the lubricant outlet connection (P or AC).
4.
Connect all electrical connections. See Typical Wir-
ing: Series Parallel Systems diagram, page 11.
5.
Ground the system. See Grounding instructions,
page 6.
Pump
The pump provides lubricant flow and pressure to oper-
ate an automatic lubrication system.
Series Parallel System
The pump requires an electrical power supply and a
timed signal from a lubrication controller (F). The pump
provides lubricant flow and pressure to operate the
injectors (E), and vents the injector system to reset the
injectors.
Series Progressive System
The pump requires an electrical power supply and a
timed signal from a lubrication controller (F). The pump
provides lubrication flow and pressure to operate
metering devices (AD).
Inlet and Outlet Components
Vent Valve
The vent valve (L) reduces system pressure in Series
Parallel system and resets the injectors.
NOTICE
Fuses (user supplied) are required on all models. To
avoid equipment damage:
•
Never operate the pump without a fuse installed.
•
A fuse of the correct voltage and amperage must
be installed in line with the power entry to the sys-
tem. Graco recommends using a 10A time delay
fuse.
LIFTING HAZARD
This equipment is heavy. Lifting or moving heavy
equipment incorrectly can cause serious injury such
as muscle strain or back injuries. To avoid injury:
•
Do not lift or move this equipment without assis-
tance.
•
Always use a lifting device secured to the pump
when moving or installing this equipment. See
Notes:, page 49 for pump weight.
The breather (J) vents the tank to the atmosphere. If it
is plugged the tank will over-pressurize and rupture.
Be sure the breather is not plugged before filling the
pump.
COMPONENT RUPTURE HAZARD
The maximum working pressure of the inlet and outlet
components in the system vary. Over-pressurizing an
inlet or outlet can cause components to rupture, seri-
ous injury such as skin injection or injury from splash-
ing fluid. To reduce the risk of component rupture:
•
Be sure to know the maximum working pressure of
each inlet and outlet component in the system.
•
Never exceed the maximum working pressure of
the inlet and outlet components.
Pressure Relief Valve
The pump design includes a self-contained pressure
relief valve (N). When needed, the valve relieves
pressure back into the pump tank (K).
Motor Details
The pump (B) is driven by a 24 V DC brushless motor
(1) with a built-in controller. The motor LED flashes
multiple times during start up and stays on during
operation. Refer to Troubleshooting, page 38 for more
information.
FIG. 3
B
1
Typical Installation: Series Parallel System
Key:
A
Lubricant output connection*
B
Pump
C
Ignition switch*
D
High-pressure lubricant supply lines*
E
Injector banks*
F
Lubrication controller*
G
Fill port
H
Overflow port
K
Tank
L
Vent Valve
NN Bearing*
*User provided
FIG. 4
A
B
C
D
E
F
G
H
K
NN
L
Typical Installation: Series Progressive System
Key:
A
Lubricant output connection*
B
Pump
C
Ignition switch*
D
High-pressure lubricant supply lines*
F
Lubrication controller*
G
Fill port
H
Overflow port
K
Tank
NN Bearing*
AD Metering device*
*User provided
FIG. 5
A
B
D
NN
F
AD
K
H
G
C
NN
NN
NN
Fill port and cover
H
Overflow port
J
Breather
K
Tank
L
Vent valve
M
Motor
N
Pressure relief valve
P
Outlet (3/8 in. NPT)
R
Gear box
S
Low level switch or level transducer
T
Pressure switch or transducer
U
Lift ring
V
Auto-fill shut off (AFSO) (optional)
Y
Follower plate
Z
Tube-in-tube
AB Plug to check venting / pressure relief
AC Refill vent plug or refill pressure relief
AD Outlet (1/4 in. NPT) (optional)
FIG. 7
AB
P
L
V
M
N
T
S
U
J
H
Z
Y
K
G
AC
R
B
AD
U
V
Fill the Tank
The fill port is used for filling and refilling the tank for
pumps with or without auto-fill.
Fill the tank through the fill port (FIG. 8).
Auto-Fill Shut Off: When grease is added, the follower
plate is pushed upward and closes the flow path. (FIG.
9).
Non-Auto-Fill Shut Off: When grease is added, the
follower plate is pushed upward. When the tank is full,
the grease will begin to flow out of the overflow port (H).
FIG. 8:
Fill Port
FIG. 9
Follower
Plate
Always fill the pump through the fill port to expel any air
from the tube-in-tube (FIG. 10).
Always use the follower plate to prime the pump for
grease NLGI 1, NLGI 2, and for cold pumping
applications.
Note: The auto-fill shut off requires using a follower
plate.
The follower plate should not be used with oil and low
viscous grease applications. The follower plate may sink
in these lubricants and block the pump inlet.
FIG. 10
Tube-in-Tube
Fill Pumps with an Auto-Fill Shut Off (AFSO)
Note: The remote filling station pump stalls (dead-heads) when the tank is full. If the pump does not stall (dead-head)
there is a leak in the system.
Key:
AA Remote fill station pump*
BB Remote fill station tank*
CC Filter*
DD Pressure relief line*
EE Fill valve* [Graco Part No. 77X542)
FF Fill valve pressure relief knob* [Part of Fill Valve 77X542]
GG Refilling line*
HH Instruction label* [Included with Fill Valve 77X542]
JJ
Supply hose*
K
Tank
V
Auto-Fill Shut Off
V1 Auto-Fill Shut Off valve pin
Y
Follower plate
*User supplied
NOTICE
Never allow the pump to run dry of the fluid being
pumped to avoid pump damage.
NOTICE
If the refilling pump runs dry it pumps air into the pump
and may cause damage. Always make sure that there
is enough lubricant in the refilling pump station.
FIG. 11
AA
BB
CC
GG
HH
EE
FF
DD
JJ
V
K
Y
V1
The auto-fill shut off (V) is used to refill the grease tank
(K) in an automatic lubrication system. When the grease
level in the tank is full, the auto-fill shut off automatically
ends the filling operation.
Always fill the tank (K) to full during refilling.
As grease is added to the tank (K), the follower plate (Y)
is pushed to the top of the tank (K) and pushes up the
valve pin (V1) which closes the inlet fluid path. Pin (V2)
pops up when the tank is full (FIG. 12).
When the fluid refilling path closes, the refilling line (GG)
pressurizes and brings the remote fill station pump (AA)
to a pressurized stall condition.
Note: The operator must monitor the system during fill-
ing of the tank to prevent any accidental fluid overflow.
Refill the Tank: Pumps with an Auto-fill
Shut Off (AFSO)
1.
Pull and hold the fill valve pressure relief knob (FF)
long enough to relieve line pressure between the fill
valve (EE) and the auto-fill shut off valve (V).
2.
Verify the auto-fill shut off pin (V2) is down, indicat-
ing it is reset (FIG. 13).
3.
Remove the dust cover (DC) from the fill coupler
(FC) on the fill valve (EE) (FIG. 14).
FIG. 12
The breather (J) vents the tank to the atmosphere. If it
is plugged the tank will over-pressurize and rupture.
Be sure the breather is not plugged before filling the
pump.
V2
FIG. 13
FIG. 14
V2
Pin Down
EE
DC
FC
FF
Connect the supply hose (JJ) between the remote
fill station pump (AA) and fill coupler (FC) port
marked with an “I” (FIG. 14).
5.
Start the remote fill station pump (AA).
6.
When the tank (K) is filled:
•
The remote fill station pump (AA) stalls
(dead-heads),
•
the auto-fill shut off pin (v2) pops up as shown in
FIG. 15,
•
The pressure gauge needle rises to the fill
pump’s set pressure.
Note: If the pump does not stall (dead-head) there is a
leak in the system.
NO7.
Turn off the remote fill station pump (AA).
8.
Pull and hold the fill valve pressure relief knob (FF)
long enough to relieve line pressure between fill
valve (EE) and Auto-fill Shut Off Valve (V) and
between remote fill station pump (AA) and fill valve
(EE).
Note: The length of time it takes to vent the pressure
varies depending on the system design and installation.
In some installations it may be necessary to repeat Step
8 to ensure pressure is relieved.
9.
Disconnect the supply hose (JJ) from the fill coupler
(FC) (FIG. 14).
10. Replace the dust cover (DC) over the fill coupler
(FC).
NOTICE
To prevent damage to the unit:
•
Check breather (J) vent for proper operation
before filling the tank (K).
•
Do not fill tank (K) beyond the overflow port (H).
•
Do not use the breather (J) as a port to fill the tank.
FIG. 15
V2
Fill Pumps Without an Auto-fill Shut Off (AFSO)
Key:
AA Remote fill station pump*
BB Remote fill station tank*
CC Filter*
DC Dust cap
G
Fill port
JJ
Supply hose*
H
Overflow port
Y
Follower plate
*User supplied
Refill the Tank: Pumps without an Auto-fill
Shut Off
FIG. 16
BB
AA
CC
JJ
DC
G
H
Y
Do not insert your finger into the overflow port while
filling a tank equipped with a follower plate. Injury or
amputation could result.
COMPONENT RUPTURE HAZARD
The maximum working pressure of each component
in the system may not be the same. To reduce the risk
of over pressurizing any component in the system,
know the maximum working pressure of each
component. Never exceed the maximum working
pressure of the lowest rated component in the
system. Over pressurizing can result in rupture, and
serious injury from skin injection or splashing fluids.
Regulate pressure to the pump so that no fluid line,
component or accessory is over pressurized.
Connect the lubricant supply hose (JJ) from the
remote filling station pump (AA) to the fill port (G)
(FIG. 17).
2.
Slowly turn on the supply lubricant until the level of
lubricant reaches the overflow port (H). When the
tank (K) is full (or overfilled) grease will flow out of
the overflow port. (H).
Note: For pump tanks (K) with a follower plate (Y),
fill the tank until the follower plate reaches the
overflow port (H) and grease flows out.
FIG. 17
The breather (J) vents the tank to the atmosphere. If it
is plugged the tank will over-pressurize and rupture.
Be sure the breather is not plugged before filling the
pump.
NOTICE
To prevent damage to the unit:
•
Check breather (J) vent for proper operation
before filling the tank (K).
•
Do not fill tank (K) beyond the overflow port (H).
•
Do not use the breather (J) as a port to fill the tank.
G
Note: Upper case letters used in the following
instructions refer to Component Identification, Typical
Installation: Series Parallel System and Typical
Installation: Series Progressive System diagrams
starting on page 9.
The unit must be securely mounted and grounded
before operation.
Priming the System
1.
After the tank (K) is completely filled, remove the
high pressure lubricant supply line (D) from the out-
let.
2.
Connect power to the pump (B).
3.
Start the pump (B) and run until all of the air has
been expelled and fluid flow is continuous (FIG. 18).
4.
Reconnect the high pressure lubricant supply line
(D) to the outlet.
Pump Operation Overview
Series Parallel System
1.
At the start of the cycle, the lubrication controller (F)
initiates a signal that closes the vent valve (L) and
starts the pump (B).
2.
The pump (B) builds pressure in the supply lines (D)
until all the injectors (E) actuate. Then the pressure
switch (T) sends a signal to the lubrication controller
(F) to end the cycle.
3.
The lubrication controller (F) terminates the signal
to the pump (B) and power to the vent valve (L).
4.
The vent valve (L) opens.
5.
Pressure is relieved in the supply lines (D), back into
the tank (K), and resets all of the injectors (E).
Series Progressive System
1.
At the start of the cycle, the lubrication controller (F)
initiates a signal to start the pump (B).
2.
The pump (B) supplies lubricant and pressure to the
metering devices (AD). When the metering devices
are active, they carry lubricant to the lube points.
3.
Continuous lubrication is provided during pump
operation.
4.
To control lubrication based upon number of cycles,
a cycle switch can be added to the metering
devices.
Shutdown
For normal shut down, disconnect power to the
lubricator controller (F) and to the pump.
FIG. 18
Low Level Switch
The low level switch (S) (FIG. 19) indicates a fault when
the follower plate (Y) reaches the factory set distance
from the bottom of the tank. The fault activates when the
remaining grease level is approximately 10 percent.
FIG. 19
Low Level Switch
NOTICE
The pump (B) should not be run without grease
because air will be introduced into the system and
could cause damage.
Output type:
1 switching output, PNP NO
Operating voltage:
10 - 30 VDC
Current:
200mA
Connection type:
M12x1, 4-pin
FIG. 20
The level transducer (S) (FIG. 21) is used for continuous
level monitoring. It indicates a fault when the follower
plate (Y) reaches the factory set distance from the
bottom of the tank. The fault activates when the
remaining grease level is approximately 10 percent.
Light Indicator
NOTICE
The pump (B) should not be run without grease, or air
will be introduced into the system and could cause
damage.
Output type:
1 analog output 0 - 10V
Operating voltage:
10 - 30 VDC
Current:
200mA
Connection type:
M12x1, 4 pin
Normal:
Green
Low-Level:
Yellow
Error:
Red
FIG. 21
The pressure switch (T) is factory set to 3000 psi (20.7
MPa, 207 bar) (FIG. 22).
When the pressure in the system reaches 3000 psi, the
pressure switch (T) closes.
Pressure Transducer
The pressure transducer (T) is used for continuous
pressure monitoring.
FIG. 22
Output type:
1 Switching output NO
Operating voltage:
24VDC
Current:
5A
Connection type:
Packard Metri-Pack 150 Series
Preset pressure:
3000 psi
Output type:
Analog 1- 5V
Operating voltage:
8 - 32V
Connection type:
Packard Metri-Pack 150 Series
Pressure range:
0-5000 psi
FIG. 23
Relieve pressure, following the Pressure Relief
Procedure, page 6.
2.
Disconnect the power to the system.
3.
Loosen and remove the four bolts (3) holding the
motor (1) to the pump, then remove the motor (1)
and the o-ring (2) (FIG. 24).
4.
Loosen and remove the four bolts and four washers
holding the pump to the tank (41) with a 5 mm Allen
wrench (FIG. 25).
5.
Pull the pump out of the tank (41).
6.
Remove the pressure relief valve cartridge (5) (FIG.
26).
7.
Remove the two bolts (6) and two nuts (not shown)
from the protection cover (8) (FIG. 27).
8.
Remove the protection cover (8).
FIG. 24
FIG. 25
1
2
3
41
47
48
FIG. 26
FIG. 27
5
8
6
Loosen the retaining nut (9) with a tube wrench (FIG.
28).
10. Pull up on the lower section to separate from the
gear head (4) (FIG. 29).
11. Remove the tube-in-tube (10) with a pipe wrench.
Verify the o-ring (11) is on the tube-in-tube (10) (FIG.
30).
12. Push on the end of the pump rod (27) to gain
access to the cross-hole located at the end of the
shovel rod (FIG. 31 and FIG. 32).
FIG. 28
FIG. 29
9
4
FIG. 30
FIG. 31
10
11
13. Place an Allen wrench or similar tool through the
slot of the shovel tube (13) and into the exposed
cross-hole to keep the shovel rod (17) steady (FIG.
32).
14. Loosen and remove the shovel piston (12) with a 10
mm socket wrench (FIG. 32).
15. Place the pump tube into a vise, protected by a
cloth, and tighten to steady the pump lower tube
(23) (FIG. 33).
16. Loosen the shovel tube (13) using a pipe wrench
and remove it from the pump lower tube (23) (FIG.
33).
17. Remove the two back up rings (14) and the o-ring
(15) from the shovel tube (13) (FIG. 33)
18. Loosen and remove the pump lower tube (23) with a
pipe wrench and remove the o-ring (24) from the
pump lower tube (23) (FIG. 34).
19. Remove the shuttle valve (16) (FIG. 35).
20. Remove the spacer (18) (FIG. 35).
FIG. 32
FIG. 33
13
17
12
13
23
14
15
FIG. 34
FIG. 35
23
24
18
16
21. Remove the piston bushing (19) (FIG. 36).
22. Remove the two (2) backup rings (20) and the o-ring
(21) from the piston bushing (19) (FIG. 36).
23. Remove the shovel rod (17) from the pump piston
(25) (FIG. 37).
24. Remove the pump piston (25) from the pump rod
(27).
Note: Remove the ball (22) from the pump piston (25)
(FIG. 38 and FIG. 39).
FIG. 36
FIG. 37
19
20
21
17
25
FIG. 38
FIG. 39
25
27
25
22
25. Loosen and remove the extension tube (26) from
the top housing. Remove two backup rings (14) and
the o-ring (15) (FIG. 40).
26. Pull out the pump rod (FIG. 41).
27. Remove the retaining nut (9) located on the upper
housing (FIG. 42).
28. Remove the outer o-ring (28) from the retaining nut
(FIG. 43).
29. Remove the throat screw (29) to get to the inner
o-ring (30) (FIG. 43).
30. Remove the bronze washer (31) from the pump
housing (FIG. 43).
31. Remove the throat seal (32) (u-cup) (FIG. 43).
FIG. 40
FIG. 41
26
14
15
27
FIG. 42
FIG. 43
9
28
30
29
31
32
Place throat seal (32) (u-cup) into the pump
housing, lips downward (FIG. 45).
2.
Place the bronze washer (31) on top of the throat
seal (32) (u-cup) (FIG. 45).
3.
Replace the inner o-ring (30) from the retaining nut
(9) with a new o-ring and grease lightly. (FIG. 46).
4.
Replace the outer o-ring (28) from the retaining nut
(9) with a new o-ring and grease lightly (FIG. 46).
5.
Place the throat screw (29) into the retaining nut (9)
using an Allen wrench and tighten (torque 16 ft-lb/
21.7 N•m)
6.
Grease the o-ring (28) and place the retaining nut
(9) into the pump housing and tighten slightly (FIG.
48).
FIG. 45
FIG. 46
32
31
30
28
FIG. 47
FIG. 48
29
9
9
28
Apply a light coating of grease to the pump rod (27)
and push it into the pump housing through the hole
in the retaining nut (9) (FIG. 49).
8.
Replace the two back-up rings (14) and o-ring (15)
with new back-up rings and o-ring and grease lightly
(FIG. 50).
9.
Place the extension tube (26) over the pump rod
and tighten to pump housing (torque 40 ft-lb/54.2
N•m) (FIG. 50).
10. Place the ball (22) back into the pump piston (25)
(FIG. 51).
11. Apply medium strength thread locking compound on
the threads of the pump rod (27).
FIG. 49
9
27
FIG. 50
FIG. 51
15
26
14
Pump
Housing
22
25
12. Place the pump piston (25) on the end of the pump
rod (27) and tighten using wrenches (torque 10
ft-lb/13.6 N•m) (FIG. 52 and FIG. 53).
13. Replace the two back-up rings (20) and o-ring (21)
with new back-up rings and o-ring and grease lightly
(FIG. 54).
14. Place the piston busing (19) into the pump lower
tube (23) until seated (FIG. 54).
15. Place the shovel rod (17) into the pump piston (25)
groove (FIG. 55).
FIG. 52
FIG. 53
25
27
25
27
FIG. 54
FIG. 55
21
20
23
19
25
17
16. Replace and lightly grease the o-ring (24) on the
lower pump tube (23) (FIG. 56).
17. Slide the pump lower tube (23) over the pump rod
(27) and connect to the extension tube (26) (torque
40 ft-lb/54.2 N•m) (FIG. 56).
18. Place the spacer (18) into the pump lower tube (23)
until seated (FIG. 57).
19. Attach the shuttle valve (16) to the shovel rod (17),
with the notch upward (FIG. 57).
20. Replace the two shovel tube (13) back-up rings (14)
and the o-ring (15) and grease lightly (FIG. 58).
21. Place the shovel tube (13) into the pump lower tube
(23) and tighten (torque 40 ft-lb/54.2 N•m) (FIG. 58).
22. Push pump rod (27) down to move the shovel rod
(17) down to access the cross-hole (FIG. 59).
23. Place an Allen wrench or similar tool through the
slot of the shovel tube (13) and into the exposed
cross-hole to keep the shovel rod (17) steady (FIG.
59).
24. Tighten the shovel piston (12) with a 10 mm socket
wrench (torque 3-4 ft-lb/4.1-5.4 N•m) (FIG. 59).
FIG. 56
FIG. 57
24
23
26
27
23
18
17
16
FIG. 58
FIG. 59
25
13
15
14
23
13
12
17
Cross-
hole
25. Replace the o-ring (11) and grease lightly (FIG. 60).
26. Slide the tube-in-tube (10) over the assembly and
up to the pump housing. Tighten the flange (torque
40 ft-lb/54.2 N•m) (FIG. 60 and FIG. 61).
27. Fit the pump assembly into the gear head (4). The
retaining nut (9) can be loosened to increase the
gap. Line up the pump rod (27) with the cut out and
slide into place (FIG. 62).
Note: Leave the retaining nut loose (9).
28. Place two bolts (6) into the pump assembly to hold
the gear head and pump assembly in place and
tighten slightly the two nuts (7) (FIG. 63).
FIG. 60
FIG. 61
4
10
11
9
4
9
Flange
FIG. 62
FIG. 63
4
27
9
Pump
Assembly
6
7
29. Tighten the retaining nut (9) with a wrench (torque
30 ft-lb/40.1 N•m) to secure (FIG. 64).
30. Remove the two bolts (6) and two nuts (7) (FIG. 65).
31. Place the protection cover (8) in place and secure
with bolts (6) and nuts (7) (not shown) (FIG. 66).
32. Place the o-ring (2) and attach the motor (1) to the
pump using the four bolts (3) (torque 11 ft-lb/14.9
N•m) (FIG. 67).
FIG. 64
FIG. 65
9
6
FIG. 66
FIG. 67
8
6
2
3
1
33. Place the o-ring onto the check valve, and then
place into the pump outlet and tighten (torque 16
ft-lb/21.7 N•m) (FIG. 68).
There is air located between the pump tube and the
tube-in-tube. Remove this air by filling it with grease to
prime the pump. If this is not done, the pump may lose
priming during operation.
34. Connect the refill pump to the fill coupler (FIG. 69).
FIG. 68
37
FIG. 69
Fill Coupler
Refill Pump
Refill Pump
Refill Filter
Fill Coupler
Pump
Tube-in-tube
Pump Tube
35. Run the refill pump until grease comes out of the
bottom of the tube-in-tube (FIG. 70).
36. Put the pump back into the tank (41) through the
cover and the gasket (FIG. 71).
37. Place the four bolts and four washers into place and
tighten with a 5 mm Allen wrench (torque 16
ft-lb/21.7 N•m) (FIG. 71).
38. Place the pressure relief valve cartridge (5) and
tighten (torque 8 ft-lb/10.8 N•m) (FIG. 72).
39. Reconnect the power to the system.
FIG. 70
1
FIG. 71
FIG. 72
41
5
Follow Pressure Relief Procedure, page 6, before
checking or repairing the pump.
2.
Check all possible problems and causes before
disassembling the pump.
Problem
Cause
Solution
Pump is not powering ON.
The red LED on the motor is not ON.
Wiring is incorrect
Polarity is wrong
Loose wire(s)
Check and verify that the wire
connections are tight.
Check and correct polarity.
Fuse is:
Wrong amperage
Not in place or missing
Faulty
Check the fuse rating and replace
with new or correct amperage fuse.
The lubrication controller is in OFF
mode.
Set the lubrication controller to the
correct lube cycle.
Pump in not powering ON.
The red LED on the motor is
blinking.
2 blinks indicate:
over current
pump is jammed
Remove the pump and repair with
new pump element parts.
2 blinks indicate:
over current
pump is jammed
The grease is too thick or the
ambient temperature is too cold to
pump.
Replace the grease if it is too thick
or the ambient temperature is too
cold to pump the grease.
Replace grease with correct
temperature rated grease.
3 blinks indicate the motor is losing
the signal.
Verify that the wire connections are
tight.
Correct polarity.
Replace the motor.
4 blinks indicate low voltage.
Check voltage and correct as
needed.
5 blinks indicate high voltage.
Check voltage and correct as
needed.
6 blinks indicate an over
temperature motor windings.
High duty cycle, set to 50% duty
cycle.
Remove the pump and repair with
new pump element parts, if the
pump is jammed,
Replace grease with correct
temperature rated grease.
7 blinks indicate over temperature
on motor driver.
High duty cycle, set to 50% duty
cycle.
Remove the pump and repair with
new pump element parts, if the
pump is jammed,
Replace grease with correct
temperature rated grease.
The Pump is cycling, but there is no
lubricant output from the outlet
The lubricant level in the tank is too
low.
Refill the tank.
Problem
Cause
Solution
The Pump is cycling, but there is no
lubricant output from the outlet. The
Pump lost priming/pump is
cavitating.
Tank was not refilled through the fill
port. Air in the tube-in-tube was
pushed into the grease tank.
Connect the refill pump to the fill port
and fill tank to remove any air.
Grease inside of the tank is not
moving to the pump shovel tube.
Install follower plate to help
distribute grease during pump
operation.
Follower plate is not moving and is
stuck inside of the tank.
Inspect and replace follower plate, if
necessary.
Follower plate is sunk into the tank.
The grease viscosity is too low.
Remove the follower plate.
The pump element parts are worn or
damaged.
Replace with new pump element
parts.
Pump is cycling, there is output of
fluid at the outlet, but pump pressure
is not building.
Pump element parts are worn or
damaged.
Replace with new pump element
parts.
Vent valve is not energized in the
series parallel system.
Check the wiring and correct.
Vent valve is energized but not
closing (leaky vent valve).
Open the inspection plug (AB), page
12, to confirm that the vent valve is
not closing (leaky). Replace the vent
valve.
Pressure relief is leaky.
Open the inspection plug (AB), page
12, to confirm pressure relief is
leaky. Replace pressure relief valve.
Problem
Cause
Solution
Parts
3A6941B
41
Parts
44
38
37
35
33
33
32
31
29
28
30
9
5
40
1
3
2
10
4
7
6
8
11
22
27
25
12
13
14
17
16
19
18
20
21
23
24
47
48
15
26
25R009 Pressure relief valve
1
6
Bolt
2
7
Nut
2
8
Protection cover
1
9
Retaining nut
1
10
Tube-in-tube
1
11
O-ring
1
12
Shovel piston
1
13
Shovel tube
1
14
Back up rings
4
15
O-ring
2
16
†
Shuttle valve
1
17
†
Shovel rod
1
18
Spacer
1
19
†
Piston bushing
1
20
Back up rings
2
21
O-rings
1
22
†
Steel ball
1
23
Pump lower tube
1
24
O-ring
1
25
†
Pump piston
1
26
Pump extension tube
1
27
Pump rod
1
28
O-ring
1
29
Throat screw
1
30
O-ring
1
31
Washer
1
32
U-cup seal
1
33
25P686 Auto-fill shut off
1
33
25P685 Auto-fill shut off plug
1
35
131711
Pressure switch
1
35
131674
Pressure transducer
1
35
567251
Plug
37
25P689 Check valve assembly
1
38
25P690 Vent valve (Series Parallel
System)
1
38
25R023 Vent valve plug (Series
Progressive System)
1
40
Refill adapter
1
41
25E166
Tank assembly with follower plate
12 Liter, low level switch for AFSO
models
1
25E323
Tank assembly with follower plate
12 Liter, level transducer for AFSO
models
1
25E324
Tank assembly with follower plate
20 Liter, low level switch for AFSO
models
1
25E167
Tank assembly with follower plate
20 Liter, level transducer for AFSO
models
1
58
25R124
Tank assembly 12 Liter, low level
switch, no follower plate, overflow
tube
1
25R122
Tank assembly 12 Liter, level
transducer, no follower plate,
overflow tube
1
25R125
Tank assembly 20Liter, low level
switch, no follower plate, overflow
tube
25R123
Tank assembly 20 Liter, level
transducer, no follower plate,
overflow tube
59
25R118
Tank assembly with follower plate,
12 Liter, level transducer, overflow
tube
25R119
Tank assembly with follower plate
20 Liter, level transducer, overflow
tube
25R120
Tank assembly with follower plate
12 Liter, low level switch, overflow
tube
25R121
Tank assembly with follower plate
20 Liter, low level switch, overflow
tube
4225P693 Follower plate assembly
1
4325P695 Low Level Switch Kit 12 Liter
1
25P697 Low Level Switch Kit 20 Liter
1
25P694 Level Transducer Kit 12 Liter
1
25P969 Level Transducer Kit 20 Liter
1
44
25P683 Front cover black with screws and
label
1
45130766
Warning label English (not shown) 1
46130899
Warning Label French and
Spanish (not shown)
1
47
M6 x 20 bolts
4
48
M6 Lock washers
4
49
Pump gasket
1
50
Breather
1
51
Overflow port plug
1
52
‡
Overflow tube
1
Ref. Part
Description
Qty.
Replacement safety labels, tags, and cards are
available at no cost.
Related Kits
53
Eye bolt
1
54
Tank cover
1
55
M8 x 32 bolts
5
56
M8 nut
5
57
M8 washer
5
Ref. Part
Description
Qty.
Ref
Part No.
Description
25P688
Motor Parts Kit
25P691
Tube-in-Tube 12 Liter Kit
25P692
Tube-in-Tube 20 Liter Kit
25P684
Protection Cover Kit
†
25P945
Pump Element Kit
25P946
Pump Seal Kit
Also included with 41, 58, 59
Also included with 41
‡
Also included with 58, 59
Also included with 41, 59
Dimensions: Pump with Tank
3A6941B
45
Dimensions: Pump with Tank
Ref
12 Liter
20 Liter
inches
mm
inches
mm
A
24.53
623.1
30.48
774.2
B
14.43
366.5
20.38
517.7
C
11.48
291.6
11.48
291.6
D
13.9
353.1
13.9
353.1
Dimensions: Stand Alone Pump
46
3A6941B
Dimensions: Stand Alone Pump
Ref
12 Liter
20 Liter
inches
mm
inches
mm
A
13.92
353.57
19.89
505.21
B
10.1
256.54
10.1
256.54
C
9.8
248.92
9.8
248.92
D
1.5
38.1
1.5
38.1
M
0.8
20.32
0.8
20.32
Top View
Dimensions: Stand Alone Pump
3A6941B
47
Top View
Dimensions: Stand Alone Pump
Ref
12 Liter/20 Liter
inches
mm
E
7.63
193.8
F
2.54
64.52
G
3.26
82.83
H
6.79
172.47
K
10.18
258.6
Top View
Bottom View
*Output of the pump depends upon the fluid being used, the output pressure, the ambient temperature, and other envi-
ronmental factors.
Compact Dyna-Star Electric Pump
US
Metric
Maximum Working Pressure
3500 psi
24.1 MPa, 241 bar
Pressure switch factory set:
3000 psi
20.7 MPA, 207 bar
Pressure relief valve factory set:
4000 psi
27.6 MPa, 276 bar
Operating Temperature
-40° F to 149° F
-40° C to 65° C
IP Rating
IP69K
Electrical Requirements
Voltage
24 VDC
Input Voltage Range
18-30 VDC
Maximum Current
10 A
Peak Operating Current
15 A
Peak Power
188 Watts
Maximum Delivery*
4.5 in3/min
74 cc/min
Grease Tank Capacity (Graco Supplied)
12 or 20 Liters
Inlet/Outlet Size
Tank Fill Port
Quick Coupler
Overflow Port
1/2 in. npt
Fluid Outlet
3/8 in. npt
Materials of Construction
Pump
steel, buna-N, acetal, lubrithane, polyurethane, brass,
polyehylene
Tank
steel, buna-N, rubber, aluminum
Weight - Without Grease in the Tank
12 Liter
66 lb
29.9 kg
20 Liter
73 lb
33.1 kg
Weight - Pump Only
12 Liter
27 lb
12.2 kg
20 Liter
30 lb
13.6 kg
Low Level Switch/Low Level Transducer
Operating Voltage
0 - 30 VDC
Output Type
1 Switching output, PNP NO
1 Analog output 0 - 10V (low level transducer)
Connection Type
M12X1, 4-pin
Pressure Switch/Pressure Transducer
Operating Voltage
24 VDC
Output Type
1 Switching output, NO
1 Analog output 1 - 5V (pressure transducer)
Connection Type
Packard Metri-Pack 150 Series
California Proposition 65
WARNING: This product can expose you to chemicals known to the State of California to
cause cancer and birth defects or other reproductive harm. For more information, go to
www.P65warnings.ca.gov.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 3A6941
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2019, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
Revision B, December 2019
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
For patent information, see www.graco.com/patents.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590