GFA TS 959 Installation Instructions Manual

Specifications

Brand: GFA
Category: Controller
Model: TS 959 (Installation Instructions Manual)
File Type: PDF
File Size: —
Pages: 34

Read Online

Read the GFA TS 959 Installation Instructions Manual online using the built-in PDF viewer.

Text of the manual

0000000 0000 51171547 XXXXX

– en – Status: j / 01.2020

GfA ELEKTROMATEN GmbH & Co. KG

Wiesenstraße 81 • 40549 Düsseldorf www.gfa-elektromaten.de [email protected]

General safety information .............................................................................................. 5

2 Technical data ................................................................................................................ 6 3 Mechanical installation .................................................................................................... 7 4 Electrical installation ....................................................................................................... 8 Connection cable connection overview ............................................................................. 9 Limit switch configuration, screwable version up to year of construction in 1997 ............ 10 Limit switch configuration, single limit switches ............................................................... 10 Carrying out the electrical installation.............................................................................. 11 Mains supply ................................................................................................................... 12 Mains connection to control ............................................................................................ 12 Completing the electrical installation ............................................................................... 12 Overview of control ......................................................................................................... 13 5 Commissioning of the control ........................................................................................ 14 DES: Rapid adjustment of final limit positions ................................................................. 14 NES: Rapid adjustment of final limit positions ................................................................. 15 6 Advanced electrical installation ..................................................................................... 16 Connection of door safety switches X2 ........................................................................... 16 External supply X1 .......................................................................................................... 17 Emergency STOP X3 ...................................................................................................... 17 X20 Relay contact ........................................................................................................... 17 External Control device X5 .............................................................................................. 17 7 Control programming .................................................................................................... 18 8 Table menu items ......................................................................................................... 19 Door operating modes ..................................................................................................... 19 Door positions ................................................................................................................. 19 Door functions ................................................................................................................. 20 Safety functions .............................................................................................................. 20 Maintenance cycle counter ............................................................................................. 21 Readout of data memory ................................................................................................. 22 Deleting of all settings / Readout GfA stick ..................................................................... 22 9 Safety devices .............................................................................................................. 23 X2: Input, door safety switch ........................................................................................... 23 X3: Input, emergency STOP ........................................................................................... 24

10  Functional description ................................................................................................... 24

X1: Mains supply of the control and supply of external devices ...................................... 24 X5: Input, control device .................................................................................................. 25 Door operating mode "Extended hold-to-run" .................................................................. 25 Potential-free X20 Relay contact ..................................................................................... 25 Force monitoring (DES only) ........................................................................................... 26 Travel time monitoring (NES only) ................................................................................... 27 Maintenance cycle counter .............................................................................................. 27 Short-circuit/overload display .......................................................................................... 27 Standby function ............................................................................................................. 27 11  Status display ................................................................................................................ 28 Faults .............................................................................................................................. 28 Commands ...................................................................................................................... 30 Status indications ............................................................................................................ 31 12  Explanation of symbols ................................................................................................. 32 13  Declaration of incorporation / Declaration of conformity ................................................. 34 Symbols Warning - Risk of injury or danger to life! Warning - Danger to life from electric shock! Note - Important information! ▶ Prompt - Required action! Illustrations show example products. Differences from the delivered product are possible.

1 General safety information

Specified use The door control is intended for a power-operated door with a drive unit (NES/DES GfA limit switch system). The safe operation is only guaranteed with specified normal use. The drive unit is to be protected from rain, moisture and aggressive ambient conditions. No liability for damage caused by other applications or non-observance of the information in the manual. Modifications are only permitted with the agreement of the manufacturer. Otherwise the Manufacturer’s Declaration shall be rendered null and void. Safety information Warning ! Failure to follow these installation instructions may result in severe injury or death.  Please read these instructions before using the product  Keep these instructions handy  Please include these instructions when you pass on the product Installation and commissioning are to be performed by skilled personnel only. Only trained electrical craftsmen are permitted to work on electrical equipment. They must assess the tasks assigned to them, recognise potential danger zones and be able to take appropriate safety measures. Installation work is only to be carried out with the supply off. Observe the applicable regulations and standards. Coverings and protective devices Only operate with corresponding coverings and protective devices. Ensure that gaskets are fitted correctly and that cable glands are correctly tightened. Spare parts Only use original spare parts.

2 Technical data

Series TS 959 Dimensions W x H x D 155 mm x 386 mm x 90 mm Installation Vertical, free of vibration Operating frequency 50 Hz / 60 Hz Supply voltage (+/- 10%) 1 N~220-230 V, PE 3 N~220-400 V, PE 3~220-400 V, PE Output power for drive unit, maximum 3 kW Protection per phase, on-site 10 A …… 16 A External mains supply: X1/L, X1/N Protection via F1 micro-fuse 1 N~230 V 1,6 A time-lag Control inputs 24 V DC, type. 10 mA Relay contact 1 potential-free changeover contact Loading of relay contacts, ohmic/inductive 230 V AC, 1 A 24 V DC, 0,4 A Control power consumption 4 W Temperature range Operation Storage -10 °C …… +50 °C +0 °C ….... +50 °C Air humidity, non-condensing up to 93 % Protection class of housing with CEE-plug IP 54 / IP 65 Protection class of housing IP 65 Compatible GfA - limit switch NES (mechanical limit switch) DES (digital limit switch)

3 Mechanical installation

Control installation!  Indoor use only  Mounting only on even ground that is free of vibration  Only mount in the vertical position  Door must be in clear view from place of installation Requirements The permissible loads on walls, mountings, connection and transmission elements must not be exceeded. Mounting The control is mounted via 4 elongated holes

4 Electrical installation

Warning - Danger to life due to electrical current!  Disconnect the cables (mains OFF) and check that the supply is off  Observe the applicable regulations and standards  Ensure proper electrical connection  Use suitable tools On-site backup fuse and disconnector unit!  Connection to the indoor installation via an all-pole disconnector unit, with current ≥ 10 A as per EN 12453 (e.g. CEE plug connector, main switch) Note! - The inputs of the following safety devices of the control are rated Performance Level c (PLc):  Slack-rope switch  Pass-door switch  Safety edge  Limit switch system  Safety circuit of the drive unit  Emergency STOP control device Connect only sensors that comply with the current EN 12453 and are suitable for Performance Level c. Observe the installation instructions of the drive unit!

Connection cable connection overview

Ⓐ DES → Ⓑ X12 DES Ⓒ MOT → Ⓓ X13 Pin Core Pin Description: Pin Core Term. Description: ① 5/wh ① +24 V safety circuit ① 3 W Phase W ② 6/bn ② Channel B (RS485) ② 2 V Phase V ③ 7/gn ③ Ground ③ 1 U Phase U ④ 8/ye ④ Channel A (RS485) ④ 4 N Neutral conductor (N) ⑤ 9/gy ⑤ Safety circuit ⑤ PE PE ⑥ 10/pk ⑥ 8 V DC supply voltage Ⓐ NES → Ⓔ X12 NES Pin Core Term. Description: ① 5/wh 11 Limit switch common +24 V, wire link to: 7, 9, 5, 14 ② 6/bn 12 S5 Auxiliary limit switch ③ 7/gn 6 S3 Open limit switch ④ 8/ye 15 S6 Auxiliary limit switch ⑤ 9/gy 8 S4 CLOSE limit switch ⑥ 10/pk 4 Safety circuit

Limit switch configuration, screwable version up to year of construction in 1997

5 6 7 10 9 3 2 1 4 (N) S6 S5 S3 S1 S2 S4 S10 F1 G1 Y1 1 3 2 4 5 X12 W1 M1 F1 Thermal contact X12 Limit switch board G1 Rectifier S1 Emergency OPEN limit switch M1 Motor S2 Emergency CLOSE limit switch S10 Emergency manual operation S3 OPEN limit switch W1 Connection cable S4 CLOSE limit switch Y1 Spring-loaded brake S5 Auxiliary limit switch S6 Auxiliary limit switch Limit switch configuration, single limit switches 5 6 7 10 9 3 2 1 4PE M1 S10 F1 S4 S3 S5 S6 W1 A1 A1 Terminal box S3 OPEN limit switch F1 Thermal contact S4 CLOSE limit switch M1 Motor S5 Auxiliary limit switch S10 Emergency manual operation S6 Auxiliary limit switch W1 Connection cable

Carrying out the electrical installation

▶ Remove covers. ▶ Open cable entry ① or ②. ▶ Insert and connect connection cable in the open cable entry ① (from below) or ② (from above). ▶ Properly tighten cable glands. Avoid damage to parts!  Open cable entry with suitable tool

3~, N, PE

230 / 400 V 50 / 60 Hz 3~, PE 230 / 400 V 50 / 60 Hz 1~, N, PE, sym. 230 V 50 / 60 Hz 1~, N, PE, asym. 230 V 50 / 60 Hz L1 L2 L3 N PE L1 L2 L3 PE N PE SI 25.15 WS, SI 45.7 WS N PE SI 25.15 WS, SI 45.7 WS 3 x 400 V 1 x 230 V / 3 x 230 V 20.1 1.5 1.8 1.9 20.2 1.6 20.3 1.7 230V 400V 20.1 1.5 1.8 1.9 20.2 1.6 20.3 1.7 230V 400V Mains connection to control 3 Completing the electrical installation Install and tighten cable entries and/or cable glands. For commissioning of the control, leave the covers open.

Overview of control

20.1 1.5 1.8 1.9 20.2 1.6 20.3 1.7 F1 = 1,6A t 230V 400V MOT DES/ NES S11 S12 X20 X3 2.1 2.2 3.1 5.15.25.3 5.4 3.2 959 X2 X5 S F1 V1 S13 X1 X1 X1 X1 5k0 DES/ NES DES or NES limit switch socket X1 Mains supply X2 Door safety switch F1 Micro-fuse 1.6 A time-lag X3 Emergency STOP control device MOT Motor socket X5 Control device, external three push-button S Selector switch X20 Potential-free relay contact S11 OPEN push-button S12 STOP push-button S13 CLOSE push-button V1 Display

5 Commissioning of the control

▶ Supply cables Insert / switch on DES: Rapid adjustment of final limit positions 1. Check output rotating direction 2. Move to OPEN final limit position 3. Save OPEN final limit position 4. Move to CLOSE final limit position 5. Save CLOSE final limit position Note!  The rapid adjustment is complete, "Hold-to-run" door operating mode is active  Change of OPEN/CLOSE final limit positions via menu items "1.1" to "1.4"

Observe the installation instructions of the drive unit!

 For adjusting the mechanical limit switch, see the drive unit installation instructions NES: Rapid adjustment of final limit positions 1. Check output rotating direction 2. Move to OPEN final limit position and adjust S3 OPEN limit switch 3. Move to CLOSE final limit position 5cm above the ground and adjust S5 pre-limit switch 4. Move to CLOSE final limit position and adjust S4 CLOSE limit switch

6 Advanced electrical installation

Connection of door safety switches X2 Connection of door safety switches X2 Pass-door switch / slack-rope switch suitable for Performance Level c (PLc) ST+ ST A18 2 1 S30a 1k5 S31 6k8 N S 6k8 2k0 1 2 N S 2.1 2.3 2.5 2.2 2.4 X2 2 S30b 1k5 1 2 3 4 1 A18 Junction box switch ST+ Mains supply ST Input for door safety switch S30a Slack-rope switch (NC contact) S30b S31 Electronic pass-door switch (Entrysense)

External supply X1

Emergency STOP X3 X20 Relay contact External supply X1 Emergency STOP X3 Relay contact X20 X1 F1 = 1,6A t A1 F1 X3 A2 2 1 S15 X20 20.1 20.2 20.3 A16 A1 External device A2 Control device A16 Relay F1 Micro-fuse 1,6 A Emergency STOP External Control device X5 External control device X5 X5 P 1 S17 2 A4 X5 4 3 2 1 S14 4 3 2 1 S16 2 1 S15 A6 X5 Three push button A4 Key push-button A6 Three push button Note!  Install and tighten cable entries and/or cable glands.

7 Control programming

1. Start programming 2. Select menu item and confirm 3.a) Set and store functions 3.b) Set and store positions (DES) 4. Exit programming Note!  Complete programming is only possible after setting the final limit positions.

8 Table menu items

Door operating modes Door operating modes Door operating mode Hold-to-run OPEN Hold-to-run CLOSE Self-hold OPEN Hold-to-run CLOSE Extended hold-to-run For NES: Set the S5 limit switch right before the CLOSE final limit position Output rotating direction Maintain output rotating direction Change output rotating direction Door positions Door positions OPEN final limit position, coarse correction (DES) Approach and store desired door position CLOSE final limit position, coarse correction (DES) Approach and store desired door position OPEN final limit position, fine correction (DES) Without door movement, [ + ] OPEN correction [ – ] CLOSE correction CLOSE final limit position, fine correction (DES) Without door movement, [ + ] OPEN correction [ – ] CLOSE correction Setting for position of relay switching point (DES) Select relay function via menu item 2.7 Approach and store desired door position; To use NES the switching point must be adjusted via the S6 auxiliary limit switch at the drive unit.

Relay function on X20

Off Impuls contact* for 1 second Permanent contact* Red lamp, permanently lit during door movement OPEN final limit position 3 seconds permanent light CLOSE final limit position 3 seconds permanent light Red lamp, permanently lit during door movement OPEN final limit position 3 seconds permanent light CLOSE final limit position Off Clearance dock leveller Active at OPEN final limit position only *) Previous teach-in of door positions via menu item 1.7 Relais X20 (only DES) or respectively via the S6 auxiliary limit switch at the drive unit (NES). Safety functions Safety functions Force monitoring (DES) 0 = Off Adjustable for 2 % to 10 % overload Travel time monitoring (NES) 0 = Off 0 to 90 seconds

Maintenance cycle counter

Maintenance cycle counter Maintenance cycle preselection 01-99 corresponds to 1,000 to 99,000 cycles Cycles are counted down Reaction upon reaching "0" Status indication "CS" appears in turns with value set by menu item 8.5. Changeover to "hold-to-run" door operating mode. Status indication "CS" appears in turns with value set by menu item 8.5. Changeover to "hold-to-run" door operating mode. Status indication "CS" appears in turns with value set by menu item 8.5. Option: Press STOP-button for 3 seconds to deactivate changeover and status indications for 500 cycles. Status indication "CS" appears in turns with value set by menu item 8.5 and relay contact X20 switches.

Readout of data memory

Readout of data memory Cycle counter 7-digit number M HT ZT T H Z E Displayed in division of ten consecutively M HT = = 1,000,000 100,000 ZT T = = 10,000 1,000 H Z = = 100 10 E = 1 Last faults Display change of the last 6 faults Data counter 7-digit number M HT ZT T H Z E Displayed in division of ten consecutively M HT = = 1,000,000 100,000 ZT T = = 10,000 1,000 H Z = = 100 10 E = 1 Cycle counter of the last change in programming Number of activations of slack-rope, pass-door switch Software version The firmware version of the control is displayed Deleting of all settings / Readout GfA stick Deleting / Readout Deleting of all settings Activating GfA stick All settings are set to factory setting! Except for cycle counter

9 Safety devices

X2: Input, door safety switch The door safety switch is installed on the door and connected to the door control via the spiral cable. Function Reaction upon activation Slack-rope switch / pass-door switch Switching contact is interrupted: Door stop Switching contact is closed: Door is ready for operation Door safety switch The door safety switches (slack-rope switch / pass-door switch) are connected to a safety circuit with Performance Level c (Plc) according to ISO 13849-1 (X2.1/X2.2). Accordingly, only switches with the same Performance Level c (Plc) may be connected. The safety circuit requires an overall terminal resistance of 5k0 for line cross-circuit monitoring. When the door safety switch is activated, it is not possible to move the door. When activated during door movement, an immediate STOP takes place. Fault indication F1.2 will be displayed. Slack-rope switch The evaluation of the door control provides for the connection of two slack-rope switches. For line cross-circuit monitoring, a resistor of 1k5 must be integrated in the switches. In the case of a line cross-circuit, fault indication F1.8 is displayed. Electronic pass-door switch (Entrysense) The electronic pass-door switch (Entrysense) has a Performance Level c (Plc) according to ISO 13849-1 and is monitored by the door control. Any other switch used must have Performance Level c (Plc) according to ISO 13849-1. For line cross-circuit monitoring, a resistor of 2k0 must be integrated in the switch. In the case of switch failure, fault indication F1.7 is displayed. In the case of a line cross-circuit, fault indication F1.8 is displayed.

X3: Input, emergency STOP

The Emergency STOP control device is connected to a safety circuit with Performance Level c (Plc) according to ISO 13849-1. Connection of an emergency STOP control device as per EN 13850 or an evaluation unit for an anti-trap safety device. The F1.4 fault indication appears upon activation. 10 Functional description X1: Mains supply of the control and supply of external devices Mains supply of the control Connection via the terminals X1/1.1 to X1/1.4 and PE Various mains connections: 3 N~, 3~, 1 N~ for symmetric and asymmetric motors. Power supply 400 V = Wire link 1.5 – 1.6 Power supply 230 V = Wire link 1.6 – 1.7 Note! ▶ Pay attention to the "Mains supply connection" and "Mains supply connection to control" descriptions Supply of external devices Connection of external devices for 230 V, such as traffic-light, illumination, relay, etc. via the terminals X1/1.8 and X1/1.9. Note!  The mains supply of external devices using terminals X1 / 1.8 and X1 / 1.9 is only possible if the door control is connected to supply networks with 3 N ~ 400 V or 1 N ~ 230 V (symmetrical)  Protection via F1, 1,6 A time-lag micro-fuse

X5: Input, control device

Warning! ▶ "Hold-to-run" door operating mode: The door must be fully visible from the operating point Note! ▶ Application without STOP push-button: Connect wire link X5.1 to wire link X5.2 Door operating mode "Extended hold-to-run" Menu item 0.1 Function ".5". At the door operating mode "Extended hold-to-run", the CLOSE-button must be pressed until door final position CLOSED is reached. If the CLOSE button is released beforehand, the door will automatically move to OPEN-direction. Note! When using NES ▶ Door can´t be closed if S5 limit switch for door operating mode "Extended hold-to- run" is not set right before CLOSE Potential-free X20 Relay contact The relay functions are described under menu item 2.7. Attention – Damage to components!  Maximum current of 1 A at 230 VAC and 0,4 A at 24 VDC  We recommend the use of LED lamps  When using light bulbs, these should have power of maximum 40 W and be shock-proof

Force monitoring (DES only)

Menu item 3.1: The force monitoring can only be used with fully balanced doors and drive units with DES. It should be able to detect when persons are moving with the door. Warning!  The force monitoring is no substitute for safety measures in providing protection against the trapping hazard Function Force monitoring ".0"  Off ".2" - "1.0"  ".2": Low limit value  "1.0": High limit value Important!  Force monitoring for doors with spring balance only  Environmental factors such as changes in temperature or wind load can lead to inadvertent triggering of force monitoring After exiting programming, the door must carry out a full OPEN and CLOSE-operation in self- hold mode. The force monitoring is a self-learning system which is effective for an opening width range of 5 cm to 2 m (approx.). Slow progressive changes, e.g. gradual reduction of the spring torsion, are compensated automatically. After force monitoring has been triggered, only the "Hold-to-run" door operating mode is possible and the F4.1 fault indication is displayed. The resetting occurs when a final limit position for the door is reached.

Travel time monitoring (NES only)

Menu item 3.3 The set travel time is automatically compared with the time measured for movement between the final limit positions. If the travel time is exceeded, the F5.6 fault indication appears. Fault indication F5.6 is reset by closing the door. Note!  The travel time is set at the factory to 90 seconds  Recommended setting value: door travel time + 7 seconds Maintenance cycle counter Menu item 8.5: A value between 0 and 99,000, as a multiple of 1000, can be selected for the maintenance cycle setting. The maintenance cycle counter reading is reduced by one each time the Open final limit position is reached. Once the maintenance cycle reaches zero, the setting from menu item 8.6 is activated. Short-circuit/overload display If there is a short circuit or an overload of the 24 VDC supply voltage, the 7-digit display vanishes. Standby function If there is no fault or command pending, the control switches to Standby. If the automatic closing duration is longer than 60 seconds, the control also switches to Standby. Only the left dot is lit up. The Standby function is terminated with a command or by activation of the selector switch S.

11 Status display

Faults Faults Display: "F" and code Code Fault description Fault causes and fault correction Terminals X2.1 – X2.2 are open. Slack-rope switch/Pass-door contact is open. Check door safety switch. Check whether the connection cable is connected. Open safety circuit (DES) Emergency manual operation has been activated. Thermal protection of the motor has tripped. Check emergency manual operation. Check door and door drive unit for stalling. Warning! Danger of the door dropping! Stalling may indicate the anti fall back device (if incorporated) has activated. Take appropriate measures. Terminals X3.1 – X3.2 are open. Emergency STOP has been activated. Check emergency STOP. Check whether the connection cable is connected. Faulty entrysense switch. Faulty entrysense installation. Open and close pass door. Check the DIP-switch in the junction box for spiral cable. Check the resistance and wiring of the spiral cable. Check the pass door installation. Line cross-circuit in the safety circuit. Switch control off and on. Check the DIP-switch in the junction box for spiral cable. Check the resistance and wiring of the spiral cable. (DES) OPEN emergency stop switch reached. In the voltage-free state, move the door back via the emergency manual operation. (NES) OPEN or CLOSE emergency stop switch reached. Emergency manual operation has been activated. Thermal protection of the motor has tripped Limit switch system has changed over from NES to DES without the control being reset. Check OPEN/CLOSE emergency stop switch. Check emergency manual operation. Reset of control via menu item "9.5". Check door and door drive unit for stalling. Warning! Danger of the door dropping! Stalling may indicate the anti fall back device (if incorporated) has activated. Take appropriate measures. (DES) CLOSE emergency stop switch reached. In the voltage-free state, move the door back via the emergency manual operation. No limit switch detected (active at initial operation). Connect the limit switch to the control. Check the limit-switch connection cable.

Display: "F" and code

Code Fault description Fault causes and fault correction Limit switch system has changed over from DES to NES without the control being reset. Reset of control via menu item "9.5". Internal plausibility error. Execute fault clearance trough movement command. Triggering of force monitoring. Check the door mechanism for stiffness. ROM error. Switch control off and on. Replace control if necessary. CPU error. Switch control off and on. Replace control if necessary. RAM error. Switch control off and on. Replace control if necessary. Internal fault of control. Switch control off and on. Replace control if necessary. Fault of digital limit switch (DES). Check DES connector and connection cable. Switch control off and on. Fault with door movement. Check the limit switch turn. Switch control off and on. Check door and door drive unit for stalling. Warning! Danger of the door dropping! Stalling may indicate the anti fall back device (if incorporated) has activated. Take appropriate measures. Fault with rotating direction (DES). Change rotating direction via menu item “0.2”. At initial operation minimum travel distance was not completed. Move the door for at least 1 second.

Display: "E" and code

Code Command description An OPEN-command is present. Inputs X5.3 A STOP command is present. Inputs X5.2 A CLOSE command is present. Inputs X5.4

Preset value for maintenance cycle counter reached.

Dot on left is not lit: Control circuit has a short circuit or is overloaded. Function for changing the rotating direction is activated, only possible during initial operation. Change of rotating direction has been carried out, only possible during initial operation. Flashing Teach in OPEN final limit position. Flashing Teach in CLOSE final limit position. Flashing UPWARDS travel active. Flashing CLOSING operation active. Stop between the set final limit positions. Stop at the OPEN final limit position. Stop at the CLOSE final limit position.

12 Explanation of symbols

Symbol Explanation Prompt: Read installation instructions Prompt: Check Prompt: Note Prompt: Note the setting of the menu below Factory setting of the menu Factory setting of the menu, value on the right Factory setting of the minimum limit, dependent on drive unit Factory setting of the maximum limit, dependent on drive unit Setting range Prompt: Select menu item or value, turn selector switch S to the left or to the right Prompt: View menu item, press selector switch S once Prompt: Store, press selector switch S once Prompt: Start programming, actuate the selector switch S for three seconds

Prompt: Setting via OPEN/CLOSE built in push-button;

Use OPEN push-button to increase value, CLOSE push-button to decrease value Prompt: Press stop button once via built in push-button Prompt: Save, press stop button once via built in push-button Prompt: Save, press stop button for three seconds via built in push-button Prompt: Reset the control, press stop button for three seconds via built in push-button Prompt: Move to door position Prompt: Move to door position for OPEN final limit position Prompt: Move to pre-limit Prompt: Move to door position for CLOSE final limit position

Declaration of incorporation / Declaration of conformity

Declaration of incorporation within the meaning of Machinery Directive 2006/42/EC for partly completed machinery, Appendix II Part B Declaration of conformity within the meaning of EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU We, GfA ELEKTROMATEN GmbH & Co. KG declare under our sole responsibility that the following product complies with the above directives and is only intended for installation in a door system. Door control TS 959 Part no.: 20095900 We undertake to transmit in response to a reasoned request by the appropriate regulatory authorities the special documents on the partly completed machinery. This product must only be put into operation when it has been determined that the complete machine/system in which it has been installed complies with the provisions of the above- mentioned directives. Authorised representative to compile the technical documents is the undersigned. Düsseldorf, 10.09.2019 Stephan Kleine CEO Signature The following requirements from Appendix I of the Machinery Directive 2006/42/EC are met: 1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.2.3, 1.2.4.2, 1.2.5, 1.2.6, 1.3.1, 1.3.2, 1.3.3, 1.3.4, 1.3.9, 1.5.1, 1.5.2, 1.5.4, 1.5.5, 1.5.6, 1.5.7, 1.5.8, 1.5.9, 1.5.10, 1.5.11, 1.5.13, 1.6.1, 1.6.2, 1.6.4, 1.7.1.1, 1.7.1.2, 1.7.2, 1.7.3, 1.7.4.3. Standards applied: EN 12453:2019 Industrial, commercial and garage doors and gates - Safety in use of power operated doors - Requirements EN 12978:2003+A1:2009 Industrial, commercial and garage doors and gates - Safety devices for power operated doors and gates - Requirements and test methods EN 60335-2-103:2015 Household and similar electrical appliances - Safety - Part 2-103: Particular requirements for drives for gates, doors and windows EN 61000-6-2:2005 Electromagnetic compatibility (EMC) Part 6-2 Generic standards – Immunity standard for industrial environments EN 61000-6-3:2007 Electromagnetic compatibility (EMC) Part 6-3 Generic standards – Emission standard for residential, commercial and light-industrial environments

Other Controller Manuals