GFA TS 959 Installation Instructions Manual
Read Online
Read the GFA TS 959 Installation Instructions Manual online using the built-in PDF viewer.
Text of the manual
0000000 0000 51171547 XXXXX
– en –
Status: j / 01.2020
GfA ELEKTROMATEN GmbH & Co. KG
Wiesenstraße 81 • 40549 Düsseldorf
www.gfa-elektromaten.de
[email protected]
General safety information .............................................................................................. 5
2
Technical data ................................................................................................................ 6
3
Mechanical installation .................................................................................................... 7
4
Electrical installation ....................................................................................................... 8
Connection cable connection overview ............................................................................. 9
Limit switch configuration, screwable version up to year of construction in 1997 ............ 10
Limit switch configuration, single limit switches ............................................................... 10
Carrying out the electrical installation.............................................................................. 11
Mains supply ................................................................................................................... 12
Mains connection to control ............................................................................................ 12
Completing the electrical installation ............................................................................... 12
Overview of control ......................................................................................................... 13
5
Commissioning of the control ........................................................................................ 14
DES: Rapid adjustment of final limit positions ................................................................. 14
NES: Rapid adjustment of final limit positions ................................................................. 15
6
Advanced electrical installation ..................................................................................... 16
Connection of door safety switches X2 ........................................................................... 16
External supply X1 .......................................................................................................... 17
Emergency STOP X3 ...................................................................................................... 17
X20 Relay contact ........................................................................................................... 17
External Control device X5 .............................................................................................. 17
7
Control programming .................................................................................................... 18
8
Table menu items ......................................................................................................... 19
Door operating modes ..................................................................................................... 19
Door positions ................................................................................................................. 19
Door functions ................................................................................................................. 20
Safety functions .............................................................................................................. 20
Maintenance cycle counter ............................................................................................. 21
Readout of data memory ................................................................................................. 22
Deleting of all settings / Readout GfA stick ..................................................................... 22
9
Safety devices .............................................................................................................. 23
X2: Input, door safety switch ........................................................................................... 23
X3: Input, emergency STOP ........................................................................................... 24
10 Functional description ................................................................................................... 24
X1: Mains supply of the control and supply of external devices ...................................... 24
X5: Input, control device .................................................................................................. 25
Door operating mode "Extended hold-to-run" .................................................................. 25
Potential-free X20 Relay contact ..................................................................................... 25
Force monitoring (DES only) ........................................................................................... 26
Travel time monitoring (NES only) ................................................................................... 27
Maintenance cycle counter .............................................................................................. 27
Short-circuit/overload display .......................................................................................... 27
Standby function ............................................................................................................. 27
11 Status display ................................................................................................................ 28
Faults .............................................................................................................................. 28
Commands ...................................................................................................................... 30
Status indications ............................................................................................................ 31
12 Explanation of symbols ................................................................................................. 32
13 Declaration of incorporation / Declaration of conformity ................................................. 34
Symbols
Warning - Risk of injury or danger to life!
Warning - Danger to life from electric shock!
Note - Important information!
▶
Prompt - Required action!
Illustrations show example products. Differences from the delivered product are possible.
1 General safety information
Specified use
The door control is intended for a power-operated door with a drive unit (NES/DES GfA limit
switch system).
The safe operation is only guaranteed with specified normal use. The drive unit is to be
protected from rain, moisture and aggressive ambient conditions. No liability for damage
caused by other applications or non-observance of the information in the manual.
Modifications are only permitted with the agreement of the manufacturer. Otherwise the
Manufacturer’s Declaration shall be rendered null and void.
Safety information
Warning ! Failure to follow these installation instructions may result in severe injury
or death.
Please read these instructions before using the product
Keep these instructions handy
Please include these instructions when you pass on the product
Installation and commissioning are to be performed by skilled personnel only.
Only trained electrical craftsmen are permitted to work on electrical equipment. They must
assess the tasks assigned to them, recognise potential danger zones and be able to take
appropriate safety measures.
Installation work is only to be carried out with the supply off.
Observe the applicable regulations and standards.
Coverings and protective devices
Only operate with corresponding coverings and protective devices.
Ensure that gaskets are fitted correctly and that cable glands are correctly tightened.
Spare parts
Only use original spare parts.
2 Technical data
Series
TS 959
Dimensions W x H x D
155 mm x 386 mm x 90 mm
Installation
Vertical, free of vibration
Operating frequency
50 Hz / 60 Hz
Supply voltage (+/- 10%)
1 N~220-230 V, PE
3 N~220-400 V, PE
3~220-400 V, PE
Output power for drive unit, maximum
3 kW
Protection per phase, on-site
10 A …… 16 A
External mains supply: X1/L, X1/N
Protection via F1 micro-fuse
1 N~230 V
1,6 A time-lag
Control inputs
24 V DC, type. 10 mA
Relay contact
1 potential-free changeover contact
Loading of relay contacts,
ohmic/inductive
230 V AC, 1 A
24 V DC, 0,4 A
Control power consumption
4 W
Temperature range
Operation
Storage
-10 °C …… +50 °C
+0 °C ….... +50 °C
Air humidity, non-condensing
up to 93 %
Protection class of housing with CEE-plug
IP 54 / IP 65
Protection class of housing
IP 65
Compatible GfA - limit switch
NES (mechanical limit switch)
DES (digital limit switch)
3 Mechanical installation
Control installation!
Indoor use only
Mounting only on even ground that is free of vibration
Only mount in the vertical position
Door must be in clear view from place of installation
Requirements
The permissible loads on walls, mountings, connection and transmission elements must not
be exceeded.
Mounting
The control is mounted via 4 elongated holes
4 Electrical installation
Warning - Danger to life due to electrical current!
Disconnect the cables (mains OFF) and check that the supply is off
Observe the applicable regulations and standards
Ensure proper electrical connection
Use suitable tools
On-site backup fuse and disconnector unit!
Connection to the indoor installation via an all-pole disconnector unit, with current
≥ 10 A as per EN 12453 (e.g. CEE plug connector, main switch)
Note! - The inputs of the following safety devices of the control are rated
Performance Level c (PLc):
Slack-rope switch
Pass-door switch
Safety edge
Limit switch system
Safety circuit of the drive unit
Emergency STOP control device
Connect only sensors that comply with the current EN 12453 and are suitable for
Performance Level c.
Observe the installation instructions of the drive unit!
Connection cable connection overview
Ⓐ DES →
Ⓑ X12 DES
Ⓒ MOT →
Ⓓ X13
Pin
Core
Pin
Description:
Pin
Core
Term. Description:
①
5/wh
①
+24 V safety circuit
①
3
W
Phase W
②
6/bn
②
Channel B (RS485)
②
2
V
Phase V
③
7/gn
③
Ground
③
1
U
Phase U
④
8/ye
④
Channel A (RS485)
④
4
N
Neutral conductor (N)
⑤
9/gy
⑤
Safety circuit
⑤
PE
PE
⑥
10/pk
⑥
8 V DC supply voltage
Ⓐ NES →
Ⓔ X12 NES
Pin
Core
Term.
Description:
①
5/wh
11
Limit switch common +24 V, wire link to: 7, 9, 5, 14
②
6/bn
12
S5 Auxiliary limit switch
③
7/gn
6
S3 Open limit switch
④
8/ye
15
S6 Auxiliary limit switch
⑤
9/gy
8
S4 CLOSE limit switch
⑥
10/pk
4
Safety circuit
Limit switch configuration, screwable version up to year of construction in 1997
5
6
7
10
9
3
2
1
4 (N)
S6
S5
S3
S1
S2
S4
S10
F1
G1
Y1
1
3
2
4
5
X12
W1
M1
F1
Thermal contact
X12
Limit switch board
G1
Rectifier
S1
Emergency OPEN limit switch
M1
Motor
S2
Emergency CLOSE limit switch
S10
Emergency manual operation
S3
OPEN limit switch
W1
Connection cable
S4
CLOSE limit switch
Y1
Spring-loaded brake
S5
Auxiliary limit switch
S6
Auxiliary limit switch
Limit switch configuration, single limit switches
5
6
7
10
9
3
2
1
4PE
M1
S10
F1
S4
S3
S5
S6
W1
A1
A1
Terminal box
S3
OPEN limit switch
F1
Thermal contact
S4
CLOSE limit switch
M1
Motor
S5
Auxiliary limit switch
S10
Emergency manual operation
S6
Auxiliary limit switch
W1
Connection cable
Carrying out the electrical installation
▶ Remove covers.
▶ Open cable entry ① or ②.
▶ Insert and connect connection cable in the open cable entry ① (from below) or ② (from
above).
▶ Properly tighten cable glands.
Avoid damage to parts!
Open cable entry with suitable tool
3~, N, PE
230 / 400 V
50 / 60 Hz
3~, PE
230 / 400 V
50 / 60 Hz
1~, N, PE, sym.
230 V
50 / 60 Hz
1~, N, PE, asym.
230 V
50 / 60 Hz
L1 L2 L3 N PE
L1 L2 L3
PE
N PE
SI 25.15 WS, SI 45.7 WS
N
PE
SI 25.15 WS, SI 45.7 WS
3 x 400 V
1 x 230 V / 3 x 230 V
20.1
1.5
1.8
1.9
20.2
1.6
20.3
1.7
230V
400V
20.1
1.5
1.8
1.9
20.2
1.6
20.3
1.7
230V
400V
Mains connection to control
3
Completing the electrical installation
Install and tighten cable entries and/or cable glands.
For commissioning of the control, leave the covers open.
Overview of control
20.1
1.5
1.8
1.9
20.2
1.6
20.3
1.7
F1 = 1,6A t
230V
400V
MOT
DES/
NES
S11
S12
X20
X3
2.1
2.2
3.1
5.15.25.3 5.4
3.2
959
X2
X5
S
F1
V1
S13
X1
X1
X1
X1
5k0
DES/
NES
DES or NES limit switch socket
X1
Mains supply
X2
Door safety switch
F1
Micro-fuse 1.6 A time-lag
X3
Emergency STOP control device
MOT
Motor socket
X5
Control device, external three push-button
S
Selector switch
X20 Potential-free relay contact
S11
OPEN push-button
S12
STOP push-button
S13
CLOSE push-button
V1
Display
5 Commissioning of the control
▶ Supply cables
Insert / switch on
DES: Rapid adjustment of final limit positions
1. Check output rotating direction
2. Move to OPEN final limit position
3. Save OPEN final limit position
4. Move to CLOSE final limit position
5. Save CLOSE final limit position
Note!
The rapid adjustment is complete, "Hold-to-run" door operating mode is active
Change of OPEN/CLOSE final limit positions via menu items "1.1" to "1.4"
Observe the installation instructions of the drive unit!
For adjusting the mechanical limit switch, see the drive unit installation
instructions
NES: Rapid adjustment of final limit positions
1. Check output rotating direction
2. Move to OPEN final limit position and adjust S3 OPEN limit switch
3. Move to CLOSE final limit position 5cm above the ground and adjust S5 pre-limit switch
4. Move to CLOSE final limit position and adjust S4 CLOSE limit switch
6 Advanced electrical installation
Connection of door safety switches X2
Connection of door safety switches X2
Pass-door switch / slack-rope switch
suitable for Performance Level c (PLc)
ST+
ST
A18
2
1
S30a
1k5
S31
6k8
N
S
6k8
2k0
1
2
N
S
2.1
2.3
2.5
2.2
2.4
X2
2
S30b
1k5
1
2
3
4
1
A18
Junction box switch
ST+
Mains supply
ST
Input for door safety switch
S30a Slack-rope switch (NC contact)
S30b
S31
Electronic pass-door switch (Entrysense)
External supply X1
Emergency STOP X3
X20 Relay contact
External supply X1
Emergency STOP X3
Relay contact X20
X1
F1 = 1,6A t
A1
F1
X3
A2
2
1
S15
X20
20.1
20.2
20.3
A16
A1 External device
A2 Control device
A16 Relay
F1 Micro-fuse 1,6 A
Emergency STOP
External Control device X5
External control device X5
X5
P
1
S17
2
A4
X5
4
3
2
1
S14
4
3
2
1
S16
2
1
S15
A6
X5
Three push button
A4 Key push-button
A6 Three push button
Note!
Install and tighten cable entries and/or cable glands.
7 Control programming
1. Start programming
2. Select menu item and confirm
3.a) Set and store functions
3.b) Set and store positions (DES)
4. Exit programming
Note!
Complete programming is only possible
after setting the final limit positions.
8 Table menu items
Door operating modes
Door operating modes
Door operating mode
Hold-to-run OPEN
Hold-to-run CLOSE
Self-hold OPEN
Hold-to-run CLOSE
Extended hold-to-run
For NES: Set the S5 limit switch right before the CLOSE final limit
position
Output rotating direction
Maintain output rotating direction
Change output rotating direction
Door positions
Door positions
OPEN final limit position, coarse correction (DES)
Approach and store desired door position
CLOSE final limit position, coarse correction (DES)
Approach and store desired door position
OPEN final limit position, fine correction (DES)
Without door movement,
[ + ]
OPEN correction
[ – ]
CLOSE correction
CLOSE final limit position, fine correction (DES)
Without door movement,
[ + ]
OPEN correction
[ – ]
CLOSE correction
Setting for position of relay switching point (DES)
Select relay function via menu item 2.7
Approach and store desired door position; To use NES the switching point must
be adjusted via the S6 auxiliary limit switch at the drive unit.
Relay function on X20
Off
Impuls contact*
for 1 second
Permanent contact*
Red lamp, permanently lit during door movement
OPEN final limit position
3 seconds permanent light
CLOSE final limit position
3 seconds permanent light
Red lamp, permanently lit during door movement
OPEN final limit position
3 seconds permanent light
CLOSE final limit position
Off
Clearance dock leveller
Active at OPEN final limit position only
*) Previous teach-in of door positions via menu item 1.7 Relais X20 (only DES) or respectively via the S6
auxiliary limit switch at the drive unit (NES).
Safety functions
Safety functions
Force monitoring (DES)
0 = Off
Adjustable for 2 % to 10 % overload
Travel time monitoring (NES)
0 = Off
0 to 90 seconds
Maintenance cycle counter
Maintenance cycle counter
Maintenance cycle preselection
01-99 corresponds to 1,000 to 99,000 cycles
Cycles are counted down
Reaction upon reaching "0"
Status indication "CS" appears in turns with value set by menu item 8.5.
Changeover to "hold-to-run" door operating mode. Status indication "CS"
appears in turns with value set by menu item 8.5.
Changeover to "hold-to-run" door operating mode. Status indication "CS"
appears in turns with value set by menu item 8.5.
Option: Press STOP-button for 3 seconds to deactivate changeover and
status indications for 500 cycles.
Status indication "CS" appears in turns with value set by menu item 8.5
and relay contact X20 switches.
Readout of data memory
Readout of data memory
Cycle counter
7-digit number
M
HT
ZT
T
H
Z
E
Displayed in division of ten consecutively
M
HT
=
=
1,000,000
100,000
ZT
T
=
=
10,000
1,000
H
Z
=
=
100
10
E
=
1
Last faults
Display change of the last 6 faults
Data counter
7-digit number
M
HT
ZT
T
H
Z
E
Displayed in division of ten consecutively
M
HT
=
=
1,000,000
100,000
ZT
T
=
=
10,000
1,000
H
Z
=
=
100
10
E
=
1
Cycle counter of the last change in programming
Number of activations of slack-rope, pass-door switch
Software version
The firmware version of the control is displayed
Deleting of all settings / Readout GfA stick
Deleting / Readout
Deleting of all settings
Activating GfA stick
All settings are set to factory setting!
Except for cycle counter
9 Safety devices
X2: Input, door safety switch
The door safety switch is installed on the door and connected to the door control via the
spiral cable.
Function
Reaction upon activation
Slack-rope switch / pass-door
switch
Switching contact is interrupted: Door stop
Switching contact is closed: Door is ready for operation
Door safety switch
The door safety switches (slack-rope switch / pass-door switch) are connected to a safety
circuit with Performance Level c (Plc) according to ISO 13849-1 (X2.1/X2.2). Accordingly,
only switches with the same Performance Level c (Plc) may be connected. The safety circuit
requires an overall terminal resistance of 5k0 for line cross-circuit monitoring. When the door
safety switch is activated, it is not possible to move the door. When activated during door
movement, an immediate STOP takes place. Fault indication F1.2 will be displayed.
Slack-rope switch
The evaluation of the door control provides for the connection of two slack-rope switches. For
line cross-circuit monitoring, a resistor of 1k5 must be integrated in the switches. In the case
of a line cross-circuit, fault indication F1.8 is displayed.
Electronic pass-door switch (Entrysense)
The electronic pass-door switch (Entrysense) has a Performance Level c (Plc) according to
ISO 13849-1 and is monitored by the door control. Any other switch used must have
Performance Level c (Plc) according to ISO 13849-1.
For line cross-circuit monitoring, a resistor of 2k0 must be integrated in the switch. In the
case of switch failure, fault indication F1.7 is displayed. In the case of a line cross-circuit, fault
indication F1.8 is displayed.
X3: Input, emergency STOP
The Emergency STOP control device is connected to a safety circuit with Performance Level c
(Plc) according to ISO 13849-1.
Connection of an emergency STOP control device as per EN 13850 or an evaluation unit for
an anti-trap safety device. The F1.4 fault indication appears upon activation.
10 Functional description
X1: Mains supply of the control and supply of external devices
Mains supply of the control
Connection via the terminals X1/1.1 to X1/1.4 and PE
Various mains connections: 3 N~, 3~, 1 N~ for symmetric and asymmetric motors.
Power supply 400 V = Wire link 1.5 – 1.6
Power supply 230 V = Wire link 1.6 – 1.7
Note!
▶ Pay attention to the "Mains supply connection" and "Mains supply connection to
control" descriptions
Supply of external devices
Connection of external devices for 230 V, such as traffic-light, illumination, relay, etc. via the
terminals X1/1.8 and X1/1.9.
Note!
The mains supply of external devices using terminals X1 / 1.8 and X1 / 1.9
is only possible if the door control is connected to supply networks
with 3 N ~ 400 V or 1 N ~ 230 V (symmetrical)
Protection via F1, 1,6 A time-lag micro-fuse
X5: Input, control device
Warning!
▶ "Hold-to-run" door operating mode:
The door must be fully visible from the operating point
Note!
▶ Application without STOP push-button: Connect wire link X5.1 to wire link X5.2
Door operating mode "Extended hold-to-run"
Menu item 0.1 Function ".5".
At the door operating mode "Extended hold-to-run", the CLOSE-button must be pressed until
door final position CLOSED is reached. If the CLOSE button is released beforehand, the door
will automatically move to OPEN-direction.
Note!
When using NES
▶ Door can´t be closed if S5 limit switch for door operating mode "Extended hold-to-
run" is not set right before CLOSE
Potential-free X20 Relay contact
The relay functions are described under menu item 2.7.
Attention – Damage to components!
Maximum current of 1 A at 230 VAC and 0,4 A at 24 VDC
We recommend the use of LED lamps
When using light bulbs, these should have power of maximum 40 W and be
shock-proof
Force monitoring (DES only)
Menu item 3.1:
The force monitoring can only be used with fully balanced doors and drive units with DES. It
should be able to detect when persons are moving with the door.
Warning!
The force monitoring is no substitute for safety measures in providing protection
against the trapping hazard
Function
Force monitoring
".0"
Off
".2" - "1.0"
".2": Low limit value
"1.0": High limit value
Important!
Force monitoring for doors with spring balance only
Environmental factors such as changes in temperature or wind load can lead to
inadvertent triggering of force monitoring
After exiting programming, the door must carry out a full OPEN and CLOSE-operation in self-
hold mode.
The force monitoring is a self-learning system which is effective for an opening width range of
5 cm to 2 m (approx.). Slow progressive changes, e.g. gradual reduction of the spring torsion,
are compensated automatically.
After force monitoring has been triggered, only the "Hold-to-run" door operating mode is
possible and the F4.1 fault indication is displayed. The resetting occurs when a final limit
position for the door is reached.
Travel time monitoring (NES only)
Menu item 3.3
The set travel time is automatically compared with the time measured for movement between
the final limit positions. If the travel time is exceeded, the F5.6 fault indication appears.
Fault indication F5.6 is reset by closing the door.
Note!
The travel time is set at the factory to 90 seconds
Recommended setting value: door travel time + 7 seconds
Maintenance cycle counter
Menu item 8.5:
A value between 0 and 99,000, as a multiple of 1000, can be selected for the maintenance
cycle setting. The maintenance cycle counter reading is reduced by one each time the Open
final limit position is reached.
Once the maintenance cycle reaches zero, the setting from menu item 8.6 is activated.
Short-circuit/overload display
If there is a short circuit or an overload of the 24 VDC supply
voltage, the 7-digit display vanishes.
Standby function
If there is no fault or command pending, the control switches to Standby.
If the automatic closing duration is longer than 60 seconds, the control also
switches to Standby. Only the left dot is lit up. The Standby function is
terminated with a command or by activation of the selector switch S.
11 Status display
Faults
Faults
Display: "F" and code
Code
Fault description
Fault causes and fault correction
Terminals X2.1 – X2.2 are open.
Slack-rope switch/Pass-door contact is open.
Check door safety switch.
Check whether the connection cable is
connected.
Open safety circuit (DES)
Emergency manual operation has been
activated.
Thermal protection of the motor has tripped.
Check emergency manual operation. Check door
and door drive unit for stalling.
Warning! Danger of the door dropping!
Stalling may indicate the anti fall back
device (if incorporated) has activated.
Take appropriate measures.
Terminals X3.1 – X3.2 are open.
Emergency STOP has been activated.
Check emergency STOP.
Check whether the connection cable is
connected.
Faulty entrysense switch.
Faulty entrysense installation.
Open and close pass door.
Check the DIP-switch in the junction box for spiral
cable. Check the resistance and wiring of the
spiral cable.
Check the pass door installation.
Line cross-circuit in the safety circuit.
Switch control off and on.
Check the DIP-switch in the junction box for spiral
cable. Check the resistance and wiring of the
spiral cable.
(DES)
OPEN emergency stop switch reached.
In the voltage-free state, move the door back via
the emergency manual operation.
(NES)
OPEN or CLOSE emergency stop switch
reached.
Emergency manual operation has been
activated.
Thermal protection of the motor has tripped
Limit switch system has changed over from
NES to DES without the control being reset.
Check OPEN/CLOSE emergency stop switch.
Check emergency manual operation.
Reset of control via menu item "9.5". Check door
and door drive unit for stalling.
Warning! Danger of the door dropping!
Stalling may indicate the anti fall back
device (if incorporated) has activated.
Take appropriate measures.
(DES)
CLOSE emergency stop switch reached.
In the voltage-free state, move the door back via
the emergency manual operation.
No limit switch detected
(active at initial operation).
Connect the limit switch to the control.
Check the limit-switch connection cable.
Display: "F" and code
Code
Fault description
Fault causes and fault correction
Limit switch system has changed over from
DES to NES without the control being reset.
Reset of control via menu item "9.5".
Internal plausibility error.
Execute fault clearance trough movement
command.
Triggering of force monitoring.
Check the door mechanism for stiffness.
ROM error.
Switch control off and on.
Replace control if necessary.
CPU error.
Switch control off and on.
Replace control if necessary.
RAM error.
Switch control off and on.
Replace control if necessary.
Internal fault of control.
Switch control off and on.
Replace control if necessary.
Fault of digital limit switch (DES).
Check DES connector and connection cable.
Switch control off and on.
Fault with door movement.
Check the limit switch turn.
Switch control off and on. Check door and door
drive unit for stalling.
Warning! Danger of the door dropping!
Stalling may indicate the anti fall back
device (if incorporated) has activated.
Take appropriate measures.
Fault with rotating direction (DES).
Change rotating direction via menu item “0.2”.
At initial operation minimum travel distance
was not completed.
Move the door for at least 1 second.
Display: "E" and code
Code
Command description
An OPEN-command is present.
Inputs X5.3
A STOP command is present.
Inputs X5.2
A CLOSE command is present.
Inputs X5.4
Preset value for maintenance cycle counter reached.
Dot on left is not lit: Control circuit has a short circuit or is overloaded.
Function for changing the rotating direction is activated, only possible during initial operation.
Change of rotating direction has been carried out, only possible during initial operation.
Flashing
Teach in OPEN final limit position.
Flashing
Teach in CLOSE final limit position.
Flashing
UPWARDS travel active.
Flashing
CLOSING operation active.
Stop between the set final limit positions.
Stop at the OPEN final limit position.
Stop at the CLOSE final limit position.
12 Explanation of symbols
Symbol
Explanation
Prompt: Read installation instructions
Prompt: Check
Prompt: Note
Prompt: Note the setting of the menu below
Factory setting of the menu
Factory setting of the menu, value on the right
Factory setting of the minimum limit, dependent on drive unit
Factory setting of the maximum limit, dependent on drive unit
Setting range
Prompt: Select menu item or value,
turn selector switch S to the left or to the right
Prompt: View menu item,
press selector switch S once
Prompt: Store,
press selector switch S once
Prompt: Start programming,
actuate the selector switch S for three seconds
Prompt: Setting via OPEN/CLOSE built in push-button;
Use OPEN push-button to increase value, CLOSE push-button to decrease value
Prompt: Press stop button once via built in push-button
Prompt: Save,
press stop button once via built in push-button
Prompt: Save,
press stop button for three seconds via built in push-button
Prompt: Reset the control,
press stop button for three seconds via built in push-button
Prompt: Move to door position
Prompt: Move to door position for OPEN final limit position
Prompt: Move to pre-limit
Prompt: Move to door position for CLOSE final limit position
Declaration of incorporation / Declaration of conformity
Declaration of incorporation
within the meaning of Machinery Directive 2006/42/EC
for partly completed machinery, Appendix II Part B
Declaration of conformity
within the meaning of EMC Directive 2014/30/EU
within the meaning of RoHS Directive 2011/65/EU
We,
GfA ELEKTROMATEN GmbH & Co. KG
declare under our sole responsibility that the
following product complies with the above
directives and is only intended for installation in a
door system.
Door control
TS 959
Part no.: 20095900
We undertake to transmit in response to a
reasoned request by the appropriate regulatory
authorities the special documents on the partly
completed machinery.
This product must only be put into operation
when it has been determined that the complete
machine/system in which it has been installed
complies with the provisions of the above-
mentioned directives.
Authorised representative to compile the
technical documents is the undersigned.
Düsseldorf, 10.09.2019
Stephan Kleine
CEO
Signature
The following requirements from Appendix I of
the Machinery Directive 2006/42/EC are met:
1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.2.3, 1.2.4.2,
1.2.5, 1.2.6, 1.3.1, 1.3.2, 1.3.3, 1.3.4, 1.3.9,
1.5.1, 1.5.2, 1.5.4, 1.5.5, 1.5.6, 1.5.7, 1.5.8,
1.5.9, 1.5.10, 1.5.11, 1.5.13, 1.6.1, 1.6.2, 1.6.4,
1.7.1.1, 1.7.1.2, 1.7.2, 1.7.3, 1.7.4.3.
Standards applied:
EN 12453:2019
Industrial, commercial and garage doors and
gates - Safety in use of power operated doors -
Requirements
EN 12978:2003+A1:2009
Industrial, commercial and garage doors and
gates - Safety devices for power operated doors
and gates - Requirements and test methods
EN 60335-2-103:2015
Household and similar electrical appliances -
Safety - Part 2-103: Particular requirements for
drives for gates, doors and windows
EN 61000-6-2:2005
Electromagnetic compatibility (EMC) Part 6-2
Generic standards – Immunity standard for
industrial environments
EN 61000-6-3:2007
Electromagnetic compatibility (EMC) Part 6-3
Generic standards – Emission standard for
residential, commercial and light-industrial
environments