Grant Internal Vecta UK | DOC 0048 | Rev 1.1 | July 2020
Grant Internal Vecta
4-16kW Condensing Wood Pellet Boiler and Side
Pellet Store
User Instructions
Grant Internal Vecta GRANT ENGINEERING (UK) LIMITED
Hopton House, Hopton Industrial Estate, Devizes, Wiltshire, SN10 2EU
Tel: +44 (0)1380 736920 Fax: +44 (0)1380 736991
Email: [email protected] www.grantuk.com
This manual is accurate at the date of printing but will be superseded and should be disregarded if specifications and/or appearances
are changed in the interests of continued product improvement. However, no responsibility of any kind for any injury, death, loss, dam
About your Boiler
4
2
About your Fuel
7
3
Boiler Control Panel
8
4
Boiler Overheat Thermostat
11
5
Electrical Isolator Switch
11
6
Safety Charge Pipe Thermostat
11
7
The Grant Logo Indicator
12
8
Lighting the Boiler
12
9
If your Boiler fails to Start
13
10
Cleaning and Servicing your Boiler
15
11
Emptying the Ash Pan
15
12
Ventilation
17
13
Electricity Supply
17
14
Sealed Heating System
18
15
Frost Protection
18
16
Service Log
19
This appliance can be
Grant Internal Vecta Your Grant Vecta wood pellet boiler should only be installed,
commissioned and serviced by an Installer who has undergone
specific product training by Grant Engineering (UK) Limited.
1.1 Condensing Boiler Operation
During the combustion process, hydrogen and oxygen combine to
produce heat and water vapour. The water vapour produced is in the
form of superheated steam that contains heat that is locked up in the
flue gases.
automatically re-start the burner (as long as there is a demand for the
boiler to run).
Figure 2: Front/left side view of boiler - door open
1.4 Topping up the Pellet Hopper
When required (see Section 1.3 above), the boiler pellet hopper can
be easily topped as follows:
•
Pull down the hinged cover at the top of the front door of the
boiler to access the control panel.
•
Set the ON/STANDBY switch on the control panel to STANDBY
LCD screen and the slow flashing Grant logo (and remote Grant logo
indicator, if fitted) will be automatically cancelled.
The boiler pellet hopper will not be completely filled by the side
pellet store. The auger will only transfer pellets to the boiler
pellet hopper until the contents switch is satisfied.
NOTE
!
The side pellet store is also fitted with a contents switch. The side
pellet store auger will only operate when this con
Your Grant Vecta boiler is designed to run on 6mm diameter EN Plus Grade A1 wood pellets (conforming to EN14961-2).
ONLY EN Plus Grade A1 (EN14961-2) wood pellets MUST be used with your Grant Vecta boiler. These pellets must be bark and
sand free.
!
CAUTION
Failure to use pellets that meet the conditions above will invalidate the product guarantee. If you are in any doubt over which pellets are suitable
please contact
The boiler control panel is located in the top front panel of the boiler.
To access the control panel pull down the cover. Refer to Figure 4.
3 Boiler Control Panel
The boiler control panel has the following (refer to Figure 5):
•
‘ON/STANDBY’ switch
•
LCD screen
•
Boiler control setting buttons
The control panel is used by the Installer or Grant Service Engineer
to check and adjust the boiler settings during commissioni
Grant Internal Vecta 3.2.2 Setpoint Temperature
The ‘Setpoint’ temperature (SP) is constantly displayed in the top right
corner of the control panel LCD screen. Refer to Figure 6.
The ‘Setpoint’ temperature is set by the Installer during
commissioning, using buttons 5 and 6, within the range 55°C to 75°C.
Refer to Figure 6. Typically it will be set to 70-75°C. This is the ‘target’
temperature setting about which the modulation of the bo