Grant Internal Vecta UK | DOC 0048  | Rev 1.1 | July 2020

Grant Internal Vecta 4-16kW Condensing Wood Pellet Boiler and Side Pellet Store User Instructions

Grant Internal Vecta GRANT ENGINEERING (UK) LIMITED

Hopton House, Hopton Industrial Estate, Devizes, Wiltshire, SN10 2EU Tel: +44 (0)1380 736920 Fax: +44 (0)1380 736991 Email: [email protected] www.grantuk.com This manual is accurate at the date of printing but will be superseded and should be disregarded if specifications and/or appearances are changed in the interests of continued product improvement. However, no responsibility of any kind for any injury, death, loss, dam

About your Boiler

4 2 About your Fuel 7 3 Boiler Control Panel 8 4 Boiler Overheat Thermostat 11 5 Electrical Isolator Switch 11 6 Safety Charge Pipe Thermostat 11 7 The Grant Logo Indicator 12 8 Lighting the Boiler 12 9 If your Boiler fails to Start 13 10 Cleaning and Servicing your Boiler 15 11 Emptying the Ash Pan 15 12 Ventilation 17 13 Electricity Supply 17 14 Sealed Heating System 18 15 Frost Protection 18 16 Service Log 19 This appliance can be

Grant Internal Vecta Your Grant Vecta wood pellet boiler should only be installed,

commissioned and serviced by an Installer who has undergone specific product training by Grant Engineering (UK) Limited. 1.1 Condensing Boiler Operation During the combustion process, hydrogen and oxygen combine to produce heat and water vapour. The water vapour produced is in the form of superheated steam that contains heat that is locked up in the flue gases.

automatically re-start the burner (as long as there is a demand for the

boiler to run). Figure 2: Front/left side view of boiler - door open 1.4 Topping up the Pellet Hopper When required (see Section 1.3 above), the boiler pellet hopper can be easily topped as follows: • Pull down the hinged cover at the top of the front door of the boiler to access the control panel. • Set the ON/STANDBY switch on the control panel to STANDBY

LCD screen and the slow flashing Grant logo (and remote Grant logo

indicator, if fitted) will be automatically cancelled. The boiler pellet hopper will not be completely filled by the side pellet store. The auger will only transfer pellets to the boiler pellet hopper until the contents switch is satisfied. NOTE ! The side pellet store is also fitted with a contents switch. The side pellet store auger will only operate when this con

Your Grant Vecta boiler is designed to run on 6mm diameter EN Plus Grade A1 wood pellets (conforming to EN14961-2).

ONLY EN Plus Grade A1 (EN14961-2) wood pellets MUST be used with your Grant Vecta boiler. These pellets must be bark and sand free. ! CAUTION Failure to use pellets that meet the conditions above will invalidate the product guarantee. If you are in any doubt over which pellets are suitable please contact

The boiler control panel is located in the top front panel of the boiler.

To access the control panel pull down the cover. Refer to Figure 4. 3 Boiler Control Panel The boiler control panel has the following (refer to Figure 5): • ‘ON/STANDBY’ switch • LCD screen • Boiler control setting buttons The control panel is used by the Installer or Grant Service Engineer to check and adjust the boiler settings during commissioni

Grant Internal Vecta 3.2.2 Setpoint Temperature

The ‘Setpoint’ temperature (SP) is constantly displayed in the top right corner of the control panel LCD screen. Refer to Figure 6. The ‘Setpoint’ temperature is set by the Installer during commissioning, using buttons 5 and 6, within the range 55°C to 75°C. Refer to Figure 6. Typically it will be set to 70-75°C. This is the ‘target’ temperature setting about which the modulation of the bo