CAUTION: This product is sensitive to Electrostatic Discharges (ESD). Take precautions while handling the product by using

proper grounding straps at all times. PHYSICAL SPECIFICATIONS Length: 76 mm (3.00 in) Width: 47 mm (1.85 in) Height: 17 mm (0.67 in) Weight: 26 g (0.92 oz) Max Readers: 1 Max Input: 2 Max Output 1 This Freedom device is certified as follows:  Electrical: UL294 and UL294B  Power over Ethernet: IEEE 802af  EMI Radiation: FCC Part 15 Class B INSTALLATION REQUIREMENTS Freedom Bridges should only be installed in dry, non-condensing environments. The ambient temperature of the environment should range between -40°C and 50°C. When mounting the Freedom Bridge to a surface, ensure that the mounting surface is a non-conductive. Causing any short-circuits on the Freedom Bridge may cause it to malfunction. DC power, reader, input contact, and output device wires should be between 16-28 AWG. They should also be stripped 5.5mm to sufficiently fit the terminal blocks and ensure that they do not come in contact with each other. INSTALLATION PROCEDURE For each of the following steps, be sure to use reference on the back for additional details: 1. Connect a Wiegand Reader to the Wiegand Reader Input on the Freedom Bridge. a. If the reader has a shield wire, connect the shield wire to the 0v terminal on the Wiegand Reader Input. If an extension cable is used between the reader and the Freedom Bridge, connect the reader’s shield wire to the cable’s shield, then connect the cable’s shield to the 0v terminal on the Wiegand Reader Input. b. Any unused wires on the reader must be evenly snipped and have their tips insulated using electrical tape or equivalent. The shield wire on the reader must also be completely insulated. 2. If you have any supervised input contacts, wire them to the Digital Contact Inputs using Method 1 or Method 2. 3. If you have any non-supervised input contacts, wire them to the Digital Contact Inputs. 4. If you have a relay output contact, wire it to the Relay Output. 5. Supply power to the Freedom Bridge using either or both of the following methods: a. A 2.25 – 5.25 W Power over Ethernet (PoE) port on an Ethernet switch connected to the Freedom Bridge using a Cat5e or Cat6 cable. b. 10 – 16 Vdc & 350 mA (300 mA external & 50 mA internal) DC power connected directly to the TB1 terminal on the Freedom Bridge. 6. If you are not using PoE to power your Freedom Bridge, connect a Cat5e or Cat6 cable from any port on an Ethernet switch to the RJ- 45 connector on the Freedom Bridge. Note: Ethernet only supports a maximum cable length of 100 m. Greater lengths can be achieved by adding switches or repeaters every 100m. 7. To configure and add the Freedom Bridge to a MESH/Freedom Server, refer to the MESH/Freedom Version 8 Software Guide. A flashing green “Ready” LED light on the Freedom Bridge circuit board indicates that the bridge is attempting to connect to the server. A solid green “Ready” LED light indicates that the Freedom Bridge has established a connection to the server and is ready to use. SINGLE PORT (FB1) FREEDOM BRIDGE™ Installation Guide FB1 Base Plate Mounting Dim mm in A 116.07 4.57 B 78.74 3.10 C 15.24 0.60 D 85.59 3.37 E 10.16 0.40 F 58.42 2.30

DC: 30 Vdc @ 1Adc

 AC: 60 Vac @ 0.5Aac Digital Contact Inputs R1-2 Ground In1-2 Non-Supervised or Supervised Input 1-2 Optional DC Power In 0v DC Power Ground +12 DC Power Input TB1 Requirements:  10 – 16 Vdc  350 mA (300 mA external & 50 mA internal) Wiegand Reader Input +12 Power Output 0v Ground D1 Data 1 Input D0 Data 0 Input Ld LED Output Bz Buzzer Output Power Output using PoE:  12.0 – 12.5 Vdc  300 mA Max. Current Power Output using DC:  8.5 – 16 Vdc  300 mA Max. Current Reset Button Press and hold this button for 10 seconds to reset the configuration back to default. 50-40-1 NOTE: As long as the total current of the reader plus a door strike DOES NOT EXCEED 300mA, you may power the door strike using the power out and ground from the Reader Input terminal block. 1 1 2 3 4 5 2 3 4 5 SHIELD

Other Controller Manuals