CAN232 FD User Manual
i
Copyright and Trademark
Copyright 2020, Grid Connect, Inc. All rights reserved.
No part of this manual may be reproduced or transmitted in any form for any purpose other than the
purchaser's personal use, without the express written permission of Grid Connect, Inc. Grid
Connect, Inc. has made every effort to provide complete details about the product in this manual, but
makes no warranty of any kind with regard to this material, including, but not limited to, the implied
warranties of merchantability or fitness for a particular purpose. In no event shall Grid Connect, Inc.
be liable for any incidental, special, indirect, or consequential damages whatsoever included but not
limited to lost profits arising out of errors or omissions in this manual or the information contained
herein.
Grid Connect, Inc. products are not designed, intended, authorized or warranted for use as
components in systems intended for surgical implant into the body, or in other applications intended
to support or sustain life, or in any other application in which the failure of a Grid Connect, Inc.
product could create a situation where personal injury, death, or severe property or environmental
damage may occur. Grid Connect, Inc. reserves the right to discontinue or make changes to its
products at any time without notice.
Grid Connect and the Grid Connect logo, and combinations thereof are registered trademarks of Grid
Connect, Inc. All other product names, company names, logos or other designations mentioned
herein are trademarks of their respective owners.
CAN232 FD is a trademark of Grid Connect, Inc.
Grid Connect
1630 W. Diehl Rd.
Naperville, IL 60563, USA
Phone: 630.245.1445
Technical Support
Phone: 630.245.1445
Fax: 630.245.1717
On-line: www.gridconnect.com
CAN232 FD User Manual
Disclaimer and Revisions
Operation of this equipment in a residential area is likely to cause interference in which case the
user, at his or her own expense, will be required to take whatever measures may be required to
correct the interference.
Attention: This product has been designed to comply with the limits for a Class B digital
device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy, and if not installed and used in
accordance with this guide, may cause harmful interference to radio communications.
Changes or modifications to this device not explicitly approved by Grid Connect will void the user's
authority to operate this device.
The information in this guide may change without notice. The manufacturer assumes no
responsibility for any errors that may appear in this guide.
Date
Rev. Author
Comments
10/30/2019
A
EDL
Preliminary Release
01/13/2020
B
EDL
Updated pictures and diagrams
CAN232 FD User Manual
iii
Warranty
Grid Connect warrants each product to be free from defects in material and workmanship for a
period of ONE YEAR after the date of shipment. During this period, if a customer is unable to
resolve a product problem with Grid Connect Technical Support, a Return Material Authorization
(RMA) will be issued. Following receipt of a RMA number, the customer shall return the product to
Grid Connect, freight prepaid. Upon verification of warranty, Grid Connect will -- at its option --
repair or replace the product and return it to the customer freight prepaid. If the product is not under
warranty, the customer may have Grid Connect repair the unit on a fee basis or return it. No services
are handled at the customer's site under this warranty. This warranty is voided if the customer uses
the product in an unauthorized or improper way, or in an environment for which it was not designed.
Grid Connect warrants the media containing software and technical information to be free from
defects and warrants that the software will operate substantially for a period of 60 DAYS after the
date of shipment.
In no event will Grid Connect be responsible to the user in contract, in tort (including negligence),
strict liability or otherwise for any special, indirect, incidental or consequential damage or loss of
equipment, plant or power system, cost of capital, loss of profits or revenues, cost of replacement
power, additional expenses in the use of existing software, hardware, equipment or facilities, or
claims against the user by its employees or customers resulting from the use of the information,
recommendations, descriptions and safety notations supplied by Grid Connect. Grid Connect liability
is limited (at its election) to:
1) refund of buyer's purchase price for such affected products (without interest)
2) repair or replacement of such products, provided that the buyer follows the above procedures.
There are no understandings, agreements, representations or warranties, expressed or implied,
including warranties of merchantability or fitness for a particular purpose, other than those
specifically set out above or by any existing contract between the parties. The contents of this
document shall not become part of or modify any prior or existing agreement, commitment or
relationship.
CAN232 FD User Manual
Table of Contents
1. Overview ........................................................................................................................... 1-1
1.1 Introduction ......................................................................................................... 1-1
1.2 Hardware Description ......................................................................................... 1-2
1.3 Model Description ............................................................................................... 1-2
1.4 CAN Network ..................................................................................................... 1-3
2. Getting Started ................................................................................................................. 1-3
2.1 Software Installation ........................................................................................... 2-4
2.1.1 TeraTerm Install .................................................................................. 2-4
2.2 Hardware Installation .......................................................................................... 2-5
2.2.1 RS232 Serial Cable ............................................................................. 2-5
2.2.2 Power Options ..................................................................................... 2-5
2.2.3 Input Power ......................................................................................... 2-5
2.2.4 OEM Options ...................................................................................... 2-5
2.2.5 Configuration Push Button .................................................................. 2-6
2.2.6 CAN Driver ......................................................................................... 2-6
2.2.7 TTL Option ......................................................................................... 2-7
2.3 Entering Configuration Mode ............................................................................. 2-8
2.3.1 RS232 Interface: ................................................................................. 2-8
2.3.2 Config Button ...................................................................................... 2-8
2.3.3 Serial Command .................................................................................. 2-8
3. Operation .......................................................................................................................... 3-9
3.1 CAN Command Mode ........................................................................................ 3-9
3.1.1 ASCII Message String Syntax ............................................................ 3-9
3.1.2 Binary Formatted Messages .............................................................. 3-12
3.2 Using Message Filters ....................................................................................... 3-19
3.2.1 Defining Filter Entries ...................................................................... 3-19
3.2.2 How Filtering Works ........................................................................ 3-19
3.3 Tunnel Mode ..................................................................................................... 3-19
4. Configuration Mode ....................................................................................................... 4-21
4.1 General Commands ........................................................................................... 4-21
4.1.1 help or ? ............................................................................................. 4-21
4.1.2 show .................................................................................................. 4-21
4.1.3 exit ..................................................................................................... 4-21
4.2 root level ........................................................................................................... 4-21
4.2.1 config ................................................................................................ 4-22
4.2.2 status.................................................................................................. 4-22
4.2.3 export config ..................................................................................... 4-22
4.2.4 import config ..................................................................................... 4-24
4.2.5 exit ..................................................................................................... 4-25
4.3 status level ......................................................................................................... 4-25
4.3.1 show all ............................................................................................. 4-26
CAN232 FD User Manual
v
4.3.2 log ...................................................................................................... 4-26
4.3.3 test...................................................................................................... 4-26
4.4 config level ........................................................................................................ 4-26
4.4.1 com .................................................................................................... 4-27
4.4.2 can ...................................................................................................... 4-27
4.4.3 command ........................................................................................... 4-27
4.4.4 filters .................................................................................................. 4-27
4.4.5 tunnel ................................................................................................. 4-27
4.4.6 save .................................................................................................... 4-27
4.5 config com ......................................................................................................... 4-27
4.5.1 baud ..................................................................................... 4-28
4.5.2 data bits ................................................................................ 4-28
4.5.3 parity .................................................................................... 4-28
4.5.4 stop ...................................................................................... 4-28
4.5.5 flow ...................................................................................... 4-28
4.5.6 mode .................................................................................... 4-28
4.5.7 startup delay ........................................................................ 4-28
4.6 config can .......................................................................................................... 4-28
4.6.1 baud ..................................................................................... 4-29
4.6.2 sample point ........................................................................ 4-29
4.6.3 timeout ................................................................................. 4-30
4.6.4 expert ................................................................................................. 4-30
4.6.5 FD ........................................................................................ 4-30
4.6.6 FDbaud ................................................................................ 4-30
4.6.7 FDexpert ............................................................................................ 4-30
4.7 config can expert ............................................................................................... 4-30
4.7.1 baud ..................................................................................... 4-31
4.7.2 sample point ........................................................................ 4-31
4.7.3 clkdiv ................................................................................... 4-31
4.7.4 tseg1 ..................................................................................... 4-31
4.7.5 tseg2 ..................................................................................... 4-31
4.7.6 sjw ....................................................................................... 4-31
4.8 config can FDexpert .......................................................................................... 4-32
4.8.1 FDbaud ................................................................................ 4-32
4.8.2 FDsample point ................................................................... 4-32
4.8.3 FDclkdiv .............................................................................. 4-32
4.8.4 FDtseg1 ............................................................................... 4-32
4.8.5 FDtseg2 ............................................................................... 4-32
4.8.6 FDsjw .................................................................................. 4-33
4.9 config command ................................................................................................ 4-33
4.9.1 filter ..................................................................................... 4-33
4.9.2 mode .................................................................................... 4-33
4.9.3 format .................................................................................. 4-33
4.9.4 timestamp ............................................................................ 4-33
4.9.5 eol ........................................................................................ 4-33
4.9.6 config cmd ........................................................................... 4-33
4.10 config tunnel .................................................................................................... 4-34
4.10.1 rxid size ............................................................................. 4-34
4.10.2 rxid ..................................................................................... 4-34
4.10.3 txid size .............................................................................. 4-34
4.10.4 txid ..................................................................................... 4-34
CAN232 FD User Manual
4.10.5 txFD .................................................................................. 4-34
4.10.6 lenFD ................................................................................. 4-34
4.10.7 trigger ................................................................................ 4-35
4.10.8 timer .................................................................................. 4-35
4.11 config filters .................................................................................................... 4-35
4.11.1 show all ........................................................................................... 4-35
4.11.2 std filter ......................................................................... 4-35
4.11.3 ext filter ........................................................................ 4-35
4.11.4 Setting Up Message Filters ............................................................. 4-35
4.12 config filters std #n.......................................................................................... 4-36
4.12.1 enable ................................................................................ 4-36
4.12.2 sid1 .................................................................................... 4-36
4.12.3 sid2 .................................................................................... 4-36
4.12.4 type .................................................................................... 4-36
4.12.5 reject .................................................................................. 4-36
4.12.6 limiter ................................................................................ 4-36
4.12.7 scale ................................................................................... 4-37
4.13 config filters ext #n ......................................................................................... 4-37
4.13.1 enable ................................................................................ 4-37
4.13.2 eid1 .................................................................................... 4-37
4.13.3 eid2 .................................................................................... 4-37
4.13.4 type .................................................................................... 4-37
4.13.5 reject .................................................................................. 4-37
4.13.6 limiter ................................................................................ 4-37
4.13.7 scale ................................................................................... 4-38
5. Technical Support .......................................................................................................... 5-39
CAN232 FD User Manual
1-1
1. Overview
1.1 Introduction
The CAN232 FD enables the use of an RS232 COM port to send and receive CAN messages on an
ISO11898 CAN or CAN FD network.
The CAN232 FD can be configured to operate in either the serial command mode or the serial tunnel mode,
providing the user with a choice as to the type of functionality desired.
In the command mode, the CAN232 FD is capable of sending and receiving arbitrary CAN messages
through the serial port, providing a complete CAN-to-232 interface. This mode also supports message
filtering to limit the range of CAN identifiers that will be received.
In Tunnel mode, the CAN232 FD establishes a full-duplex virtual serial link between itself and an
application on another CAN node. A serial device can transparently send and receive serial stream data on
the CAN232 serial line and the CAN232 will route the data over CAN to the configured target device. In
previous versions of the product this feature was referred to as virtual circuit (VC) mode.
The CAN232 FD operating mode and all other configuration parameters are accessed through the ‘config’
button. Pressing the button causes the CAN232 FD to enter configuration mode where it then prompts the
user to modify configuration parameters. In addition to parameter configuration, the configuration mode
also provides diagnostic tools.
The CAN232 FD represents an evolution of the earlier CAN232 product line, providing a performance
increase and enhanced features, while retaining much backward compatibility.
The CAN-RS232 version is shown below.
The new units are based on an ARM Cortex-M0+ 32-bit microcontroller. All device interfaces (UART,
CAN) have built-in hardware buffers that allow for high-speed data flow without data loss. Hardware
buffering, coupled with a fast and efficient CPU, allows each interface to operate at its maximum rated
limit.
The new hardware version is now equipped with an isolated CAN interface standard.
CAN232 FD User Manual
1.2 Hardware Description
The following drawing shows the location and function of the LEDs.
1.3 Model Description
The CAN232 FD platform has the option of DTE (male) or DCE (female) on the RS232 serial cable. It has a
Male DB9 CAN connector.
CAN232 FD User Manual
1-3
1.4 CAN Network
Before trying to send commands to the CAN232 FD, make sure the unit is attached to a valid CAN network
with at least one other node attached and running. Without another node on the network, the CAN232 FD
will attempt to transmit the message indefinitely (as per CAN 2.0A/B specifications).
Make sure there are terminating resistors on the network. A terminating resistance of 120 ohms is
appropriate for ISO11898 drivers. Attempts to communicate over the CAN network without terminating
resistors can lead to erratic behavior and many long hours of trouble shooting.
CAN ISO11898 specifies a three wire bus: CAN_H, CAN_L, and GROUND. Failure to provide a common
ground between network nodes will create some weird behavior. At best, the system will appear to
communicate correctly until either the weather changes, you touch something, or the date changes. CAN_H
and CAN_L form a differential pair and each one must be referenced to a common ground in order to work
properly.
PIN
Function
2
CAN-L
3
CAN-Ground
7
CAN-H
CAN232 FD User Manual
2. Getting Started
2.1 Software Installation
2.1.1 TeraTerm Install
You will need an RS232 serial port and terminal emulation software in order to configure the CAN232 FD
device over the serial line. For Windows platforms we recommend the Tera Term terminal emulator. You
can download the software using the following link: Tera Term Install.
CAN232 FD User Manual
2-5
2.2 Hardware Installation
2.2.1 RS232 Serial Cable
The table below lists the serial line data and control signals for the CAN232 FD. The RS232 interface is a 9-
pin D-style connector. Male connectors are wired as DTE and female connectors are wired as DCE.
CAN232 FD
Signal
Direction
(J8)
DTE DB-9 Male
Pin #
DCE DB-9
Female Pin #
Data Out (TXD)
Out (3)
3
2
Data In (RXD)
In (4)
2
3
Ground
(1)
5
5
CTS
In (6)
8
7
RTS
Out (5)
7
8
No Connection
(8)
6
4
No Connection
(9)
4
6
+9-32Vdc
In (10)
9
9
No Connection
(7)
1
1
Frame Ground
(2)
Shield
Shield
Units can be specially ordered with TTL level signals, which are connected in the same manner as the
RS232 versions.
Pin 9 on the DB-9 connector is shown with +9-32 VDC going to Pin 10 of J8. This is an optional method of
supplying power to the device. It is not required if you use a different power source. For more details about
power, see Power Options below.
2.2.2 Power Options
For the CAN-232 model, power (+9-32 VDC) can be supplied through a Phoenix terminal block, through a
barrel jack, through the serial cable (usually pin 9), or through the OEM option connector on the circuit
board. The factory default configuration is the Barrel Jack.
2.2.3 Input Power
The input power range is from 9-32VDC for the CAN-232 model.
2.2.4 OEM Options
The OEM version comes without a RS232 cable. It is designed to be part of an embedded product. Instead
of a cable connector, a 10-pin header is used to connect the signals to an OEM’s circuit board.
The CAN signals are brought out to the OEM connector at J10. The OEM connector is a 10-pin header
soldered to the bottom side of the board.
CAN232 FD User Manual
The RS232 signals are brought out to the OEM connector at J11. Power can be supplied through pin 1 and
Ground is tied to pin 9.
2.2.5 Configuration Push Button
Pressing the recessed push button for less than 3 seconds will put the processor into configuration mode.
Pressing the recessed push button for MORE than 3 seconds will reset the unit to factory defaults.
See the Configuration Mode chapter for detailed operation.
2.2.6 CAN Driver
The TCAN1042 is a CAN transceiver that meets or exceeds the specifications of the ISO11898-2 (2016)
High Speed CAN (Controller Area Network) physical layer standard. The device is designed for use in CAN
FD networks up to 5 Mbps (megabits per second). Additionally, the device includes many protection
features to enhance device and network robustness.
The TCAN1042 is characterized for operation over the ambient temperature range of –40°C to 125°C.
Failsafe Outputs
Meets or Exceeds ISO 11898-2 requirements
Bus Fault Protection: ±58 V
Dominant Time-Out Function
IEC ESD Protection up to ±15 kV
DOMINANT TIME-OUT
A dominant time-out circuit in the TCAN1042 prevents the driver from blocking network communications
if a local controller fault occurs. The time-out circuit is triggered by a falling edge on TXD. If no rising edge
occurs on TXD before the time-out of the circuits expires, the driver is disabled to prevent the local node
from continuously transmitting a Dominant bit. If a rising edge occurs on TXD, commanding a Recessive
bit, the timer will be reset and the driver will be re-enabled. The time-out value is set so that normal CAN
communication will not cause the Dominant time-out circuit to expire.
FAILSAFE
The supply terminals have undervoltage detection that places the device in protected mode. This protects the
bus during an undervoltage event on either of the supply terminals.
CAN232 FD User Manual
2-7
THERMAL SHUTDOWN
The TCAN1042 has an internal thermal shutdown circuit that turns off the driver outputs when the internal
temperature becomes too high for normal operation. This shutdown circuit prevents catastrophic failure due
to short-circuit faults on the bus lines. If the device cools sufficiently after thermal shutdown, it will
automatically re-enable, and may again rise in temperature if the bus fault is still present. Prolonged
operation with thermal shutdown conditions may affect device reliability.
BUS LOADING
The TCAN1042 family is specified to meet the 1.5 V requirement with a 50Ω load, incorporating the worst
case including parallel transceivers. The differential input resistance of the TCAN1042 family is a minimum
of 30 kΩ. If 100 TCAN1042 family transceivers are in parallel on a bus, this is equivalent to a 300Ω
differential load worst case. That transceiver load of 300 Ω in parallel with the 60Ω gives an equivalent
loading of 50 Ω. Therefore, the TCAN1042 family theoretically supports up to 100 transceivers on a single
bus segment. However, for CAN network design margin must be given for signal loss across the system and
cabling, parasitic loadings, network imbalances, ground offsets and signal integrity thus a practical
maximum number of nodes is typically much lower.
2.2.7 TTL Option
This CAN-232 model option allows a user to connect TTL level signals to the board through the serial
interface. This option is by special order and NOT a field option.
CAN232 FD User Manual
2.3 Entering Configuration Mode
2.3.1 RS232 Interface:
To view the Configuration menu, first connect the CAN232 FD serial cable to a PC running a monitor
program, such as Tera Term. Set the COM port parameters to 115200, 8, 1, None. The cable should be a
null-modem if the CAN232 FD is wired as DTE.
2.3.2 Config Button
Press the Config button (for less than 3 seconds) located next to the cable. The config prompt should appear
as ‘>’. Type ‘help’ or ? to display the possible commands and settings for each level.
Whenever the CONFIG button is pressed, the COM port settings are automatically set to 115200, 8, N, 1
with no flow control in case the user forgets the configured settings.
2.3.3 Serial Command
When using Command mode it’s possible to enter configuration mode using the proper command. In this
case the serial parameters are left at their configured settings. This ensures that an application can smoothly
change from RUN to CONFIG and back to RUN mode without needing to change COM port settings.
CAN232 FD User Manual
3-9
3. Operation
The following sections describe the operation of the CAN232 FD.
3.1 CAN Command Mode
In the command mode, the CAN232 FD is capable of sending and receiving arbitrary CAN messages via the
use of ASCII or Binary formatted message strings (Figure 3).
Figure 3
When the CAN232 FD receives a valid command message on the serial line, it converts it to a CAN
message and transmits it out over the CAN network.
Conversely, when a CAN message is received by the CAN232 FD, it converts it to a command message and
transmits it out of the serial port.
The CAN232 FD supports ten (10) CAN receive message filters each for standard IDs and Extended IDs
consisting of individual IDs, ID ranges or classic ID masks. By using the masks to specify which bits of an
identifier are to be compared to the filter value, the CAN232 FD is capable of selecting an arbitrary sub-set
of the total possible CAN messages and rejecting all others. Thus, only desired messages will be received
and the total required bandwidth of the serial link is kept to a minimum.
3.1.1 ASCII Message String Syntax
Message strings are formatted as human-readable ASCII sequences that are easy to enter and read. Each
message string is of variable length, depending on the number of data bytes included in the message.
In order to facilitate human CAN network monitoring, there is an option to append a CR/LF sequence to
each output ASCII message string. Doing so makes it much easier to watch the incoming messages on a
terminal where each message is on a separate line. See Appending CR/LF To Received Command Strings
on page 3-12.
Messages starting with ‘|’ will generate a self-receive of the transmitted message. If the message is
transmitted on CAN successfully, it will be received back on the serial line as if it had been sent from some
other node.
Terminating with ‘!’ instead of ‘;’ indicates the intent is a one-shot transmit. This command option is
maintained in the firmware for backward compatibility with previous versions. A one-shot message is only
CAN232 FD User Manual
accepted when the mode option under command settings in configuration is set to one-shot. In this mode,
no attempts to automatically retry on error will happen. This is used in time-triggered CAN protocols.
All message string characters are in upper case only. Lower case characters will be interpreted as a syntax
error and the message will be discarded.
Identifier and data fields are treated as base-16 digits (hexadecimal).
The syntax of both transmit and receive message strings are identical.
There are three types of message strings:
- Normal CAN messages
- Remote Transmission Request CAN messages (RTR)
- Report CAN error status messages (optional)
As per the CAN 2.0A/B specification, RTR messages do not contain data. To support RTR messages, the
syntax is modified to include an explicit single-digit length. The length field is treated as a base-10 digit and
must be a single digit between 0 and 8. The CAN FD specification does not support Remote frames.
3.1.1.1 Normal CAN Message
A normal CAN message consists of the identifier type (11-bit or 29-bit), identifier, CAN type, and data
bytes and is encoded as follows:
Normal CAN Message Syntax
: … ;
The first character,‘:’, is for synchronization and allows the CAN232 FD parser to detect the beginning of a
command string.
The following character is either ‘S’ for standard 11-bit, or ‘X’ for extended 29-bit identifier type.
The ‘IDENTIFIER’ field consists of three or eight hexadecimal digits, indicating the value of the identifier.
Note that if a 29-bit value is entered and an 11-bit value was specified, the command will be treated as
invalid and ignored.
The character ‘N’ indicates that the message is a normal (non-RTR) CAN 2.0A/B transmission. The
character ‘F’ or ‘H’ indicates that the message is a normal CAN FD transmission without or with the higher
data baud rate switch (BRS) respectively.
Each ‘DATA-n’ field is a pair of hexadecimal digits defining the data byte to be sent. If no data is to be sent
(length = zero), then the data bytes are omitted. CAN FD messages can be up to 64 data bytes in length
where only lengths 0 – 8, 12, 16, 20, 24, 32, 48 and 64 are valid based on the standard.
Each data byte specified must be a hexadecimal pair in order to eliminate ambiguity.
The terminating character ‘;’ signals the end of the message.
CAN232 FD User Manual
3-11
Examples
Example #1
:S123N12345678;
This message string indicates a 11-bit identifier whose value is $123, is normal, and has four data bytes: $12
$34 $56 and $78.
Example #2
:XF00DN;
This message string indicates a 29-bit identifier whose value is $F00D, is normal, and has zero data bytes.
Example #3
:X12345678H0102030405060708090A0B0C;
This message string indicates a 29-bit identifier whose value is $12345678, is normal CAN FD with BRS,
and has twelve data bytes: $01 $02 $03 $04 $05 $06 $07 $08 $09 $0A $0B and $0C.
3.1.1.2 RTR CAN Message
A RTR CAN message consists of the type (11-bit or 29-bit), identifier, CAN type, length, does not have any
data bytes, and is encoded as follows:
RTR CAN Message Syntax
: ;
The first character ,‘:’, is for synchronization and allows the CAN232 FD parser to detect the beginning of a
command string.
The following character is either ‘S’ for standard 11-bit, or ‘X’ for extended 29-bit identifier type.
The ‘IDENTIFIER’ field consists of from one to eight hexadecimal digits, indicating the value of the
identifier. Note that if a 29-bit value is entered and an 11-bit value was specified, the command will be
treated as invalid and ignored.
The character ‘R’ indicates that the message is a RTR transmission. The CAN FD specification does not
support Remote frames.
The ‘LENGTH’ field is a single ASCII decimal character from ‘0’ to ‘8’ that specifies the length of the data
being requested.
The terminating character ‘;’ signals the end of the message.
Examples
Example #1
:S123R8;
This message string indicates a 11-bit identifier whose value is $123, is RTR, and has length 8.
Example #2
:XF00DR0;
This message string indicates a 29-bit identifier whose value is $F00D, is RTR, and has length 0.
CAN232 FD User Manual
3.1.1.3 Report Error Status Message
A Report Error Status message indicates changes in the current CAN bus error status detected by the CAN
controller. This message is only transmitted if the report err feature is enabled under the command
settings. By default this feature is disabled.
Report CAN Error Status Message Syntax
: ;
The first character ,‘:’, is for synchronization and allows the receiver’s parser to detect the beginning of a
command string.
The character ‘E’ indicates that this is a Report Error Status message.
The following character represents the new CAN error status.
‘A’ – Active (actively flagging errors on the bus, CAN operation is normal)
‘W’ – Warning (error count above the warning threshold)
‘P’ – Passive (only passively flagging errors on the bus, too many errors detected)
‘B’ – Bus Off (no longer transmitting on the CAN bus)
The terminating character ‘;’ signals the end of the message.
3.1.1.4 Appending CR/LF To Received Command Strings
When using the CAN232 FD to view received CAN messages directly on a terminal, the user can set a
configuration parameter to append a sequence to each message string generated. This makes it
easier for the user to see each received message as each message will be on a separate line. See the eol
option under the command settings.
3.1.1.5 Timestamp
Outgoing serial command messages can have a 16-bit time-stamp appended to them with a 1-ms resolution.
In ASCII mode, the timestamp is appended to the data block in uppercase HEX ASCII in the same way that
the data field is presented (i.e.: two ASCII HEX digits to represent a byte). The '@' character is inserted
between the last DATA digit and the first TIMESTAMP digit to differentiate between the two fields.
Zero-length messages appear as they would normally, except the prefixed timestamp is added.
Ex 1:S12N12@F00F: This is a 11-bit identifier with 1 data byte and timestamp of $F00F ms.
Ex 2:X13N@2EDF: This is a 29-bit identifier with 0 data bytes and timestamp of $2EDF ms.
Ex 3:S14R5@15E5: This is a 11-bit identifier with RTR=5 and timestamp of $15E5 ms.
3.1.2 Binary Formatted Messages
Transmitting CAN messages over the serial line in binary is more efficient because the data can be
transmitted as-is without converting each byte to two ASCII characters in hex. However, it’s also a little
more complicated to frame the message since any binary value that marks the start of a message may also
appear in the data. This binary protocol makes use of DLE sequences and byte stuffing to uniquely frame
messages.
A binary message always begins with the 2-byte DLE SYNC sequence $FF $00. If this sequence happened
to occur in the middle of the binary message, it would incorrectly signal to the receiver that a new message
CAN232 FD User Manual
3-13
was starting. To ensure the SYNC sequence does not occur in the middle of the message, the transmitter
must scan the message for the binary value $FF and replace it with the 2-byte DATA sequence $FF $01.
The $01 byte is the stuff byte. Now if a ..$FF $00.. pair occurs inside the message then it will be translated
into $FF $01 $00 by the byte stuffing. The receiver must convert the DLE DATA sequence back to a single
byte $FF by removing the $01 byte.
The following table defines all the valid DLE sequences implemented in the protocol. Any other DLE
sequence received should be considered an error and will cause the message to be discarded.
DLE Sequences Defined
Name
Byte-0
Byte-1
Type
Comment
SYNC
$FF
$00
FRAME
Marks start of message
DATA
$FF
$01
DATA
Defines data value of $FF
CONFIG
$FF
$02
COMMAND
Configuration mode entry command
REPORT
$FF
$03
STATUS
Report CAN error status change
DLE RE-SYNC
$FF
$FF
ERROR
Restarts DLE sequence parsing
After the DLE SYNC sequence to start the message, a CAN message header format is defined, followed by
the CAN data values. Note any of the header or data bytes might contain the $FF value and must be scanned
to perform the byte stuffing.
CAN232 FD User Manual
3.1.2.1 CAN 2.0A/B Messages
The tables below show the Binary message format for CAN 2.0A/B messages.
Note: The ONE-SHOT bit in earlier versions has been replaced with the FD bit. Set the mode option to one-
shot under the command settings in configuration to continue using the one-shot functionality. Also, when
FD=0, then BIT-6 is interpreted as the RTR flag.
STD-NORMAL Message Format
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
Byte-0
1
1
1
1
1
1
1
1
SYNC
Byte-1
0
0
0
0
0
0
0
0
Byte-2
EXT=0
RTR=0
FD=0
SELF-
RCV
LENGTH
TYPE
Byte-3
0
0
0
0
0
ID (10 -8)
ID
Byte-4
ID (7-0)
Byte-5
DATA-0
DATA
Byte-6
DATA-1
Byte-7
DATA-2
Byte-8
DATA-3
Byte-9
DATA-4
Byte-10
DATA-5
Byte-11
DATA-6
Byte-12
DATA-7
STD-RTR Message Format
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
Byte-0
1
1
1
1
1
1
1
1
SYNC
Byte-1
0
0
0
0
0
0
0
0
Byte-2
EXT=0
RTR=1
FD=0
SELF-
RCV
LENGTH
TYPE
Byte-3
0
0
0
0
0
ID (10 -8)
ID
Byte-4
ID (7-0)
CAN232 FD User Manual
3-15
EXT-NORMAL Message Format
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
Byte-0
1
1
1
1
1
1
1
1
SYNC
Byte-1
0
0
0
0
0
0
0
0
Byte-2
EXT=1
RTR=0
FD=0
SELF-
RCV
LENGTH
TYPE
Byte-3
0
0
0
ID (28-24)
ID
Byte-4
ID (23-16)
Byte-5
ID (15-8)
Byte-6
ID (7-0)
Byte-7
DATA-0
DATA
Byte-8
DATA-1
Byte-9
DATA-2
Byte-10
DATA-3
Byte-11
DATA-4
Byte-12
DATA-5
Byte-13
DATA-6
Byte-14
DATA-7
EXT-RTR Message Format
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
Byte-0
1
1
1
1
1
1
1
1
SYNC
Byte-1
0
0
0
0
0
0
0
0
Byte-2
EXT=1
RTR=1
FD=0
SELF-
RCV
LENGTH
TYPE
Byte-3
0
0
0
ID (28-24)
ID
Byte-4
ID (23-16)
Byte-5
ID (15-8)
Byte-6
ID (7-0)
CAN232 FD User Manual
3.1.2.2 CAN FD Messages
The tables below show the Binary message format for CAN FD. The FD feature must be enabled under can
settings to support these commands.
The Length field is now a Length Code for FD data lengths up to 64 bytes. When FD=1, then BIT-6 is
interpreted as the BRS flag. The BRS flag indicates whether Bit Rate Switching is active for the message
and data transmission is at the higher data rate.
STD-NORMAL FD Message Format
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
Byte-0
1
1
1
1
1
1
1
1
SYNC
Byte-1
0
0
0
0
0
0
0
0
Byte-2
EXT=0
BRS
FD=1
SELF-
RCV
LENGTH CODE
TYPE
Byte-3
0
0
0
0
0
ID (10 -8)
ID
Byte-4
ID (7-0)
Byte-5
DATA-0
DATA
Byte-6
DATA-1
Byte-7
DATA-2
Byte-8
DATA-3
Byte-9
DATA-4
Byte-10
DATA-5
:
:
Byte-n
DATA-N
CAN232 FD User Manual
3-17
EXT-NORMAL FD Message Format
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
Byte-0
1
1
1
1
1
1
1
1
SYNC
Byte-1
0
0
0
0
0
0
0
0
Byte-2
EXT=1
BRS
FD=1
SELF-
RCV
LENGTH CODE
TYPE
Byte-3
0
0
0
ID (28-24)
ID
Byte-4
ID (23-16)
Byte-5
ID (15-8)
Byte-6
ID (7-0)
Byte-7
DATA-0
DATA
Byte-8
DATA-1
Byte-9
DATA-2
Byte-10
DATA-3
Byte-11
DATA-4
Byte-12
DATA-5
:
:
Byte-n
DATA-N
Length Code Defined
Length Code
Length
$00-$08
0-8
$09
12
$0A
16
$0B
20
$0C
24
$0D
32
$0E
48
$0F
64
CAN232 FD User Manual
3.1.2.3 Report Error Status Message
A Report Error Status message indicates changes in the current CAN bus error status detected by the CAN
controller. This message is only transmitted if the report err feature is enabled under the command
settings. By default this feature is disabled.
Report Error Status Message Format
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
Byte-0
1
1
1
1
1
1
1
1
SYNC
Byte-1
0
0
0
0
0
0
0
0
Byte-2
1
1
1
1
1
1
1
1
REPORT
Byte-3
0
0
0
0
0
0
1
1
Byte-4
ERROR STATUS CODE (7-0)
STATUS
The following character represents the new CAN error status code.
‘A’ – Active (actively flagging errors on the bus, CAN operation is normal)
‘W’ – Warning (error count above the warning threshold)
‘P’ – Passive (only passively flagging errors on the bus, too many errors detected)
‘B’ – Bus Off (no longer transmitting on the CAN bus)
3.1.2.4 Timestamp
Outgoing serial command messages can have a 16-bit time-stamp appended to them with a 1-ms resolution.
In binary mode, the received CAN messages are extended by appending the time-stamp as two binary bytes
(MSB first).
The encoding of the two bytes is the same as for the DATA field (i.e., If any of the time-stamp bytes is a
$FF byte, it is escaped).
The time-stamp field is always two logical bytes, but can be expanded up to four in the case where both
MSB and LSB bytes are $FF.
NORMAL Timestamped Message Format
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
Byte-0
1
1
1
1
1
1
1
1
SYNC
Byte-1
0
0
0
0
0
0
0
0
:
:
TYPE
ID
DATA
Byte-n
DATA-N
Byte-n+1
TIMESTAMP (15-8)
TIME
STAMP
Byte-n+2
TIMESTAMP (7-0)
CAN232 FD User Manual
3-19
3.2 Using Message Filters
In command mode, the CAN232 FD supports message filtering through the use of identifier ranges or masks
and filter values, providing the ability to receive only a sub-set of all the possible CAN identifiers. This can
greatly reduce the required serial data bandwidth on a busy network by only allowing certain messages to be
received. Required serial bandwidth can be further reduced by using limiters.
To use the filters, they must be enabled, their type must be specified, and appropriate ID values must be
assigned. This configuration is done while in the configuration mode.
3.2.1 Defining Filter Entries
CAN messages can be filtered according to a message filter list.
The list defines which identifiers will be received and which will be ignored.
Each filter in the list can be enabled or disabled separately.
Definitions can be either a single ID, a pair of IDs, an ID range or an ID mask and match value.
A filter can be inclusive (allow to pass) or exclusive (discard).
Standard (11-bit) and Extended (29-bit) IDs can be defined.
Definitions must not conflict nor overlap.
Filtering can be enabled or disabled under the Command settings.
When disabled, all CAN messages are received regardless of the definitions in the list.
When enabled, only messages which match filter definitions in the list will be passed through.
An additional limiter can be set for messages that pass through the filter by dividing the number of
messages (eg. 1 out of 20) or keeping a minimum frequency (eg. 1 every 100 ms).
An empty filter list that is enabled will receive nothing, but still permit transmission (making the
unit effectively TX only).
The maximum number of filter definitions possible is ten (10) each for Standard and Extended IDs.
3.2.2 How Filtering Works
Whenever the CAN232 FD receives a CAN message from the network, it checks to see if any filters are
enabled. If none of the filters are enabled, it assumes no filtering should be performed and outputs the
command message format to the serial port. If any filters are enabled, the CAN232 FD will attempt to match
the received message to each enabled filter in order. At the first successful match, the message is accepted
(if inclusive) or discarded (if exclusive). If accepted the message is checked against any limiters then
converted to command message format and output to the serial port. If no matches were successful, the
message is discarded.
Note: The output format depends on mode : ASCII or BINARY
3.3 Tunnel Mode
Tunnel mode is used to transparently transfer serial data over the CAN bus. In previous versions of the
product this feature was referred to as virtual circuit (VC) mode. In Tunnel mode, the CAN232 FD
establishes a full-duplex virtual serial link between itself and an application on another CAN node. A serial
device can transparently send and receive serial stream data on the CAN232 serial line and the CAN232 will
route the data over CAN to the configured target device.
A pair of CAN232 devices can be utilized to create a virtual serial link. By providing a virtual serial link
over the CAN network, an application can exchange data with a serial device in a network-transparent
fashion, using existing CAN network cabling as a data link (Figure 4).
CAN232 FD User Manual
Figure 4
The Tunnel requires two, user-configurable, CAN identifiers for the transmit ID in the serial to CAN
direction and the receive ID in the CAN to serial direction. The IDs can be either standard 11-bit or
extended 29-bit. Since virtually every CAN protocol provides a sub-set of unused or ‘user-specific’
identifiers, establishing IDs for the Tunnel on a CAN network in conjunction with an existing protocol is
very likely supported and easy to do.
The receive ID is used to specify which CAN message should be received by the CAN232 FD when waiting
for incoming stream data. The CAN232 FD will filter out all other messages. When a CAN message
containing this identifier is received, the data in the message is assumed to be stream data from another
application on the CAN bus or perhaps from another CAN232 FD. This data is then read and output directly
to the serial COM port.
The CAN232 FD takes data bytes coming into its serial port and groups them into CAN messages for
transmission. When a remote CAN application target receives these messages, it extracts the data bytes and
processes them as needed based on the serial protocol being tunneled. This operation is fully transparent to
the connected serial device.
The CAN232 FD only sends CAN messages when a full CAN packet of data has been received. This leads
to a case where the last part of a data stream is not sent if it is less than eight bytes long. The maximum data
length can also be configured for CAN FD implementations, default 32. To deal with leftover data in a
transparent fashion, the CAN232 FD provides a timeout feature that will automatically force a transmission
of the last accumulated byte(s) after a specified maximum waiting time.
The CAN232 FD can also be configured to force immediate transmission upon detection of a specific user-
configured byte in the data stream (CR or LF, for example).
CAN232 FD User Manual
4-21
4. Configuration Mode
Configuration mode provides a command line interface organized into multiple levels or groups that can be
navigated by the user. Appropriate commands are provided at each level. The current level is always
displayed as part of the prompt (eg. “config com>”). The two main levels of the CLI are for status (status>)
and configuration (config>). Under the status level the user can view unit information such as serial number
and firmware version as well as a log of error and debug events.
The commands are detailed in the same sequence as they appear in the following menu.
4.1 General Commands
All commands are entered in lower case
4.1.1 help or ?
Displays a list of available commands for the given level.
4.1.2 show
Displays the configuration settings for all parameters on the given level.
4.1.3 exit
Exits the level and returns to the next level up.
4.2 root level
The root level is the entry point into configuration mode. Under the root level you can navigate to the config
and status levels. There are also tools for backing up and restoring the configuration settings.
>?
config
status
export config
import config
exit
>config
config>?
com
can
command
filters
tunnel
save
exit
CAN232 FD User Manual
4.2.1 config
Move to the config level.
4.2.2 status
Move to the status level.
4.2.3 export config
Export the current configuration to the serial line. The serial output can be captured, logged or copy/pasted
to a configuration file.
Here is an example of using Tera Term to log the configuration output to a file.
First, configure the CAN232 FD to the desired settings and return to the root level.
Second, in Tera Term click on File then Log…
Pick the location and file name to save the configuration file and click Save.
CAN232 FD User Manual
4-23
Enter the export config command at the prompt. The configuration output will look similar to the
following:
Note: The configuration is stored as simple text and it can be edited, but it is recommended that edits to the
configuration be done on the device for error checking and then use the export config command and log to
a new file.
Next, Click Close in the Tera Term: Log window.
>export config
config
{
com
{
baud : 115200
data bits : 8
parity : none
stop : 1
flow : none
mode : command
startup delay : 0
}
can
{
baud : 250000
sample point : 80
timeout : 0
FD : disable
FDbaud : 2000000
.
.
.
type : range
reject : no
limiter : none
scale : 0
}
}
tunnel
{
rxid size : std
rxid : 0
txid size : std
txid : 0
txFD : disable
lenFD : 32
trigger : 0
timer : 20
}
}
>
CAN232 FD User Manual
4.2.4 import config
Writes new configuration settings received over the serial line from a configuration file created using the
export config command.
Here is an example of using Tera Term to send the configuration file to the CAN232 FD.
First, enter the import config command.
Second, in Tera Term click on File then Send file…
>import config
I14: Send the configuration file...
CAN232 FD User Manual
4-25
Pick the location and file name of the configuration file and click Open.
The transfer should complete quickly without errors and exit at the config level where you can check the
new settings and use the save command to save the settings in the device.
4.2.5 exit
Exits the root level and leaves configuration mode. The device restarts with the last saved configuration
settings.
4.3 status level
Under the status level you can view device information and diagnostic data.
>import config
I14: Send the configuration file...
config>
status>?
show all
log
test
exit
CAN232 FD User Manual
4.3.1 show all
This will show all the CAN232 FD status information which includes factory settings, general configuration
and a CAN bus health status.
4.3.2 log
This will display the debug log generated during the previous device operation.
4.3.3 test
To confirm that all LED indicators are working, this diagnostic causes the CAN-TX/RX and COM-TX/RX
LED indicators to cycle continuously.
To terminate the diagnostic, press any key.
4.4 config level
Under the config level you can view and change settings for the operation and behavior of the device.
status>log
CAN: command mode
UART bad idfmt
CAN Error_warning
CAN Error_passive
status>
status>show all
Device Name : CAN232
Serial Number : 000002
FW Version : 01.00
COM 115200 baud, 8, none, 1, none, command
CAN 250000 bps
CAN Status : Active
Bus Off events : 0
Passive events : 0
Warning events : 0
Overrun events : 0
CAN Rx Packets : 0
CAN Rx Overflow: 0
CAN Rx Skipped : 0
CAN Tx Packets : 0
CAN Tx Timeouts: 0
status>
CAN232 FD User Manual
4-27
4.4.1 com
Move to the com level to view or make adjustments to the serial com settings.
4.4.2 can
Move to the can level to view or make adjustments to the CAN settings.
4.4.3 command
Move to the command level to view or make adjustments to the command mode settings.
4.4.4 filters
Move to the filters level to view or make adjustments to the filter settings.
4.4.5 tunnel
Move to the tunnel level to view or make adjustments to the tunnel mode settings.
4.4.6 save
Saves the current configuration settings to non-volatile memory. A warning message is displayed if you exit
the config level without saving your changes.
4.5 config com
The com level contains the serial communication settings.
config com>?
show
baud
data bits
parity
stop
flow
mode
startup delay
exit
>config
config>?
com
can
command
filters
tunnel
save
exit
CAN232 FD User Manual
4.5.1 baud
Sets the baud rate to be used for serial communication. Any baud rate from 1200 to 1000000 (1 Mbps) can
be chosen, but not all baud rates can be matched exactly by the device. All standard serial baud rates are
supported. The default baud rate is 115200.
4.5.2 data bits
Set the number of data bits for serial communication. Values of 7 or 8 are valid.
4.5.3 parity
Set the parity to the options of none, even, or odd.
4.5.4 stop
Sets the number of stop bits for serial communication. Values of 1 or 2 are valid.
4.5.5 flow
Sets flow control to the options of none, software or hardware. Software flow control uses the XON and
XOFF characters for limiting serial communication to prevent buffer overflow and is only recommended for
ASCII protocols. Hardware flow control uses the RS232 control signals RTS and CTS for limiting serial
communication.
4.5.6 mode
Sets the serial communication mode to the options of command or tunnel.
In the command mode, the CAN232 FD is capable of sending and receiving arbitrary CAN messages over
the serial line via the use of ASCII or binary formatted messages.
In tunnel or virtual circuit mode, the CAN232 FD transparently tunnels serial data over the CAN network
between devices creating a virtual serial link. The CAN ID destination for received serial data is specified
along with the CAN ID for receiving the serial data packets.
4.5.7 startup delay
Sets the serial communication startup delay. Values of 0 to 60 seconds are valid.
This feature allows the user to specify a time-out from the time the unit is first powered up to when it starts
processing CAN messages. This can be useful to eliminate message flooding on the serial line while the host
application code gears up.
4.6 config can
The can level contains the CAN communication settings.
CAN232 FD User Manual
4-29
4.6.1 baud
Sets the baud rate to be used for classic CAN communication. Any baud rate from 5000 to 1000000 (1
Mbps) can be chosen, but not all baud rates can be matched exactly by the device. All standard CAN baud
rates are supported. The default baud rate is 250000.
Defining the CAN Bit-Time
In order for a CAN network to correctly arbitrate multiple senders and to adapt to variances in system
clocks, the low-level bit time must be correctly specified for the specific characteristics of the network. The
CAN232 FD provides a means of configuring these parameters so as to support a wide array of network
scenarios.
Note that the CAN bit-time settings at this level can only be specified as a baud rate and sample point. The
code will find the best fit solution. Move to the expert level for fine tune adjustments to the CAN bit
sampling.
clkdiv 1
Tq = ---------- baud = ------------------------ = bits/sec
16,000,000 Tq * (1 + tseg1 + tseg2)
CAN Bus State During Configuration
While the CAN232 FD is in the configuration mode, the CAN controller is in the bus-off state. It does not
interact with the bus and is effectively ‘invisible’. Thus, it is possible to perform configuration of the
CAN232 FD while still connected to an active CAN network and not adversely affect network operation.
Once the configuration state is exited, the CAN232 FD will activate the CAN controller and begin
immediately interacting with the CAN network according to the CAN ISO 11898-2 specification.
It is the users responsibility to ensure that the configuration settings are appropriate for the network to which
the CAN232 FD is connected so that the CAN232 FD operates correctly and does not cause erratic network
operation.
4.6.2 sample point
Sets the sample point during the total bit time as a percentage which dictates when the CAN signal is
sampled at each bit. A value from 70 to 95% can be chosen. The default is 80%. It is very important that all
nodes on a CAN FD network have the same sample point as this dictates when a bit rate switch occurs.
config can>?
show
baud
sample point
timeout
expert
FD
FDbaud
FDexpert
exit
CAN232 FD User Manual
4.6.3 timeout
Sets a CAN message transmit timeout in milliseconds. A value of 0 to 10000 ms can be chosen. A value of 0
will disable the timeout.
When a message is transmitted on the CAN bus and loses arbitration to a higher priority message or is
transmitted without an acknowledgement, it is resent continuously until successful. It is possible, under
heavy CAN bus loads or faulty CAN bus, to place the unit in a state where no more input parsing from the
COM port can occur due to the internal buffers being full and the CAN TX not being able to proceed. This
will block further CAN messages from being transmitted. Also under this condition, a config command
cannot be processed. This is to ensure that no CAN messages are lost while waiting for the CAN bus to
become available.
In order to alleviate this potential problem, a timeout parameter can be specified that will cancel a transmit
in progress and allow other CAN messages to be transmitted.
4.6.4 expert
Move to the expert level to view or make fine tune adjustments to the CAN bit sampling.
4.6.5 FD
Set the CAN FD feature to enable or disable. With the CAN FD feature disabled (default), the CAN232 FD
can only send and receive CAN 2.0A/B packets on the bus and makes the device incompatible with CAN
FD networks.
4.6.6 FDbaud
Sets the baud rate to be used during the data phase of CAN FD communication when bit rate switching
(BRS) is enabled. Any baud rate from 20000 to 4000000 (4 Mbps) can be chosen, but not all baud rates can
be matched exactly by the device. All standard CAN baud rates are supported. The default baud rate is
2000000 (2 Mbps).
Defining the Data CAN Bit-Time
In order for a CAN FD network to correctly operate and to adapt to variances in system clocks, the low-
level bit time must be correctly specified for the specific characteristics of the network. The CAN232 FD
provides a means of configuring these parameters so as to support a wide array of network scenarios.
Note that the FD CAN bit-time settings at this level can only be specified as a baud rate. The code will find
the best fit solution. Move to the FDexpert level for fine tune adjustments to the CAN bit sampling.
4.6.7 FDexpert
Move to the FDexpert level to view or make fine tune adjustments to the CAN bit sampling during the
data phase of CAN FD.
4.7 config can expert
The can expert level contains the fine tune parameters for CAN bit timing and sampling.
CAN232 FD User Manual
4-31
4.7.1 baud
Sets the baud rate to be used for classic CAN communication. This is the same setting as described for the
previous config can level.
4.7.2 sample point
Sets the sample point during the total bit time as a percentage which dictates when the CAN signal is
sampled at each bit. This is the same setting as described for the previous config can level.
4.7.3 clkdiv
Sets the clock divider for the CAN controller’s baud rate generator. This value is automatically determined
by the device based on baud rate and does not normally need to be adjusted. Any value from 1 to 48 will be
accepted. The baud rate and other expert settings will be automatically adjusted accordingly when this
parameter is changed.
The CAN controller uses a 16 MHz internal clock for baud rate generation.
4.7.4 tseg1
Sets the time segment 1 for the total bit time which is the number of clock cycles before the sample point.
This value is automatically determined by the device based on baud rate, clkdiv and sample point. It does
not normally need to be adjusted. Any value from 1 to 256 will be accepted. The baud rate, sample point and
other expert settings will be automatically adjusted accordingly when this parameter is changed.
4.7.5 tseg2
Sets the time segment 2 for the total bit time which is the number of clock cycles after the sample point.
This value is automatically determined by the device based on baud rate, clkdiv and sample point. It does
not normally need to be adjusted. Any value from 1 to 128 will be accepted. The baud rate, sample point,
sjw and other expert settings will be automatically adjusted accordingly when this parameter is changed.
4.7.6 sjw
Sets the synchronization jump width (sjw) for the CAN receiver. This is the maximum number of Tq
adjustment the receiver can make to adjust for oscillator differences between CAN nodes. It does not
normally need to be adjusted. Any value from 1 to tseg2 will be accepted.
config can expert>?
show
baud
sample point
clkdiv
tseg1
tseg2
sjw
exit
CAN232 FD User Manual
4.8 config can FDexpert
The can FDexpert level contains the fine tune parameters for CAN FD bit timing and sampling during the
data phase.
4.8.1 FDbaud
Sets the baud rate to be used during the data phase of CAN FD communication when bit rate switching
(BRS) is enabled. This is the same setting as described for the previous config can level.
4.8.2 FDsample point
Sets the sample point during the total bit time of the data phase as a percentage which dictates when the
CAN signal is sampled at each data bit.
4.8.3 FDclkdiv
Sets the clock divider for the CAN controller’s baud rate generator. This value is automatically determined
by the device based on baud rate and does not normally need to be adjusted. Any value from 1 to 32 will be
accepted. The FDbaud rate and other FDexpert settings will be automatically adjusted accordingly when this
parameter is changed.
The CAN controller uses a 16 MHz internal clock for baud rate generation.
4.8.4 FDtseg1
Sets the time segment 1 for the total bit time in the data phase which is the number of clock cycles before
the sample point. This value is automatically determined by the device based on FDbaud rate, FDclkdiv and
FDsample point. It does not normally need to be adjusted. Any value from 1 to 32 will be accepted. The
FDbaud rate, FDsample point and other FDexpert settings will be automatically adjusted accordingly when
this parameter is changed.
4.8.5 FDtseg2
Sets the time segment 2 for the total bit time in the data phase which is the number of clock cycles after the
sample point. This value is automatically determined by the device based on baud rate, clkdiv and sample
point. It does not normally need to be adjusted. Any value from 1 to 16 will be accepted. The FDbaud rate,
FDsample point, FDsjw and other FDexpert settings will be automatically adjusted accordingly when this
parameter is changed.
config can FDexpert>?
show
FDbaud
FDsample point
FDclkdiv
FDtseg1
FDtseg2
FDsjw
exit
CAN232 FD User Manual
4-33
4.8.6 FDsjw
Sets the synchronization jump width (SJW) for the CAN FD receiver in the data phase. This is the
maximum number of Tq adjustment the receiver can make to adjust for oscillator differences between CAN
nodes. It does not normally need to be adjusted. Any value from 1 to tseg2 will be accepted.
4.9 config command
The command level contains the Command mode parameters.
4.9.1 filter
Sets whether incoming CAN message filtering is on or off.
4.9.2 mode
Sets whether the command’s CAN interface mode is normal, monitor or one-shot. A mode of normal
allows transmit and receive of CAN packets with retries. A mode of monitor only allows receive of CAN
packets and prevents any disturbing of the CAN bus. In one-shot mode no attempts to automatically retry
any transmissions due to error or lost arbitration will occur. This is used in time-triggered CAN protocols.
4.9.3 format
Sets the serial command message format between ascii or binary. The ASCII format uses only printable
characters that can also be easily read by humans on a terminal display. All data is converted to ASCII hex.
The binary format requires fewer bytes on the serial line and is more efficient for a software application.
4.9.4 timestamp
Outgoing serial command messages can have a 16-bit time-stamp appended to them with a 1-ms resolution.
Values of off or on are valid.
4.9.5 eol
Configuration parameter to append an end-of-line sequence to each ASCII command message string
generated. Values of none, cr, lf, crlf and lfcr are valid.
4.9.6 config cmd
It is possible to enter configuration mode through the COM port in Command mode by enabling this option.
Valid settings are enable or disable.
ASCII mode command = :CONFIG;
config command>?
show
filter
mode
format
timestamp
eol
config cmd
report err
exit
CAN232 FD User Manual
BINARY mode command = FF 00 FF 02 43 4F 4E 46 49 47
Note: The last six bytes of the BINARY command are ASCII 'C' 'O' 'N' 'F' 'I' 'G'
4.10 config tunnel
The tunnel level contains the Tunnel mode parameters.
4.10.1 rxid size
Sets the receive ID size between std (11-bit) or ext (29-bit).
4.10.2 rxid
Sets the receive ID for CAN messages containing the serial stream data. Values between 0 and 1FFFFFFF
in hex can be specified.
4.10.3 txid size
Sets the transmit ID size between std (11-bit) or ext (29-bit).
4.10.4 txid
Sets the transmit ID for CAN messages containing the serial stream data. Values between 0 and 1FFFFFFF
in hex can be specified.
4.10.5 txFD
Sets whether the serial stream data is sent with CAN FD protocol. Valid settings are enable or disable. If
disabled, CAN 2.0A/B messages are transmitted with 8 serial bytes per message maximum. If enabled, CAN
FD messages with bit rate switching (BRS) are transmitted and the lenFD parameter sets the maximum data
length.
4.10.6 lenFD
Sets the maximum data length when transmitting serial stream data in CAN FD packets. Valid settings are 8,
12, 16, 20, 24, 32, 48, or 64 bytes. These are the specific data length codes (DLC) supported by CAN FD.
When a CAN FD transmit is initiated by the trigger byte or the timer then the largest possible data length
code, based on the remaining data length, is transmitted in successive packets until the initiated serial data is
completely transferred.
config tunnel>?
show
rxid size
rxid
txid size
txid
txFD
lenFD
trigger
timer
exit
CAN232 FD User Manual
4-35
4.10.7 trigger
Sets the trigger byte value that will force an immediate CAN transmit when matched on the serial input.
Values between 00 and FF in hex can be specified. A value of 00 disables the trigger.
4.10.8 timer
Sets the timer value in milliseconds that will force a CAN transmit of any remaining serial data. Values
between 0 and 1000 ms can be specified. A value of 0 disables the timer.
4.11 config filters
The filters level contains the CAN ID filters used in command mode.
4.11.1 show all
This will show all the filters configured in a condense list for easier viewing.
This shows the default filter settings which are two fully inclusive identifier ranges.
A + marks the filter as enabled (inclusive) and a – marks the filter as enabled (exclusive). A space (no + or -
) means the filter is disabled.
4.11.2 std filter
Move to the standard identifier filter instance detail view. The instance must be from 1 – 10.
4.11.3 ext filter
Move to the extended identifier filter instance detail view. The instance must be from 1 – 10.
4.11.4 Setting Up Message Filters
To use message filtering, each filter used must be enabled and configured as to the type of filtering that is
desired. Once all configuration parameters have been saved and the CAN232 FD enters the normal
config filters>show all
Standard Filters
01: + 000 - 7FF
Extended Filters
01: + 00000000 - 1FFFFFFF
config filters>
config filters>?
show all
std filter
ext filter
exit
CAN232 FD User Manual
operating mode, the new filter settings will become active and will be applied to each received CAN
message.
4.12 config filters std #n
The filters std #n level contains the detail parameters for standard ID filter #n.
4.12.1 enable
Sets the enable value for this filter to no or yes.
4.12.2 sid1
Sets the sid1 value for this filter. Values between 0 and 7FF in hex can be specified.
4.12.3 sid2
Sets the sid2 value for this filter. Values between 0 and 7FF in hex can be specified.
4.12.4 type
Sets the type for this filter between range, dual and classic.
range: sid1=< ID <= sid2
dual: ID = sid1 or ID = sid2
classic: (Active/1 bits in sid1) = (ID bits in sid2)
Note to create a single ID filter use type range or dual and set sid1=sid2=ID or use type classic and set
sid1=7FF and sid2=ID.
4.12.5 reject
Sets the reject option for this filter to no or yes for inclusive or exclusive filtering respectively.
4.12.6 limiter
Sets the limiter type for this filter between none, divide and frequency. The none selection is the default
and disables the limiter so all messages pass. The divide setting will only pass 1 message out of every scale
messages. The frequency setting will only pass 1 message every scale milliseconds.
config filters std #1>?
show
enable
sid1
sid2
type
reject
limiter
scale
exit
CAN232 FD User Manual
4-37
4.12.7 scale
Sets the scale value for this limiter. Values between 0 and 10000 can be specified.
4.13 config filters ext #n
The filters ext #n level contains the detail parameters for extended ID filter #n.
4.13.1 enable
Sets the enable value for this filter to no or yes.
4.13.2 eid1
Sets the eid1 value for this filter. Values between 0 and 1FFFFFFF in hex can be specified.
4.13.3 eid2
Sets the eid2 value for this filter. Values between 0 and 1FFFFFFF in hex can be specified.
4.13.4 type
Sets the type for this filter between range, dual and classic.
range: eid1=< ID <= eid2
dual: ID = eid1 or ID = eid2
classic: (Active/1 bits in eid1) = (ID bits in eid2)
Note to create a single ID filter use type range or dual and set eid1=eid2=ID or use type classic and set
eid1=1FFFFFFF and eid2=ID.
4.13.5 reject
Sets the reject option for this filter to no or yes for inclusive or exclusive filtering respectively.
4.13.6 limiter
Sets the limiter type for this filter between none, divide and frequency. The none selection is the default
and disables the limiter so all messages pass. The divide setting will only pass 1 message out of every scale
messages. The frequency setting will only pass 1 message every scale milliseconds.
config filters ext #1>?
show
enable
eid1
eid2
type
reject
limiter
scale
exit
CAN232 FD User Manual
4.13.7 scale
Sets the scale value for this limiter. Values between 0 and 10000 can be specified.
CAN232 FD User Manual
5-39
5. Technical Support
If you are experiencing a problem, please read the user manual and other technical document supplied on
the product CD. If you are unable to solve the problem, please contact technical support.
We are located in a far western suburb of Chicago and are on Central Standard Time. Our location allows us
to best service all of North America.
Grid Connect, Inc.
1630 W. Diehl Road
Naperville, Illinois 60563 USA
+1 (800) 975-GRID (4743) USA Toll Free
+1 (630) 245-1445 Phone
+1 (630) 245-1717 Fax