Kamoer X1 Quick Start Manual
Read Online
Read the Kamoer X1 Quick Start Manual online using the built-in PDF viewer.
Text of the manual
Pump X1 - Quick start instruction
Thank you for choosing the Kamoer X1 Bluetooth dosing pump, Kamoer's latest dosing system that
can be controlled by most mobile Bluetooth devices..
For the latest information about this product and the support service information for the product,
please visit www.kamoer.com.
PACKING LIST
1 Dosing Pump X1, 1 Power Supply, 1 Graduated Cylinder, 1 Power Link Cable, transparent PVC
Tubing
SPECIFICATIONS
Dosing Channel: 1
Dosing Times: 12 times / day -once / 31 days
Fluid Volume: .1ml - 6000ml
Accuracy: <+/-2%
Pump Life: >2000 hour
INSTALLATION
1. Attach the dosing pump head to the main unit by lining up the center
of the exposed side of the dosing head on to the front of X1 unit and
push the head in until it snaps into place. You can install the head with
the tubing down, up to the left or right. Just choose the option that
better suits your setup.
2. The location of your X1 should be easy to access; it should be close to
an electrical power source, close to sump or location where the dosing tubing will be installed and
also have easy access to dosing containers that will hold the solutions. The unit should also be
installed higher than the sump but not directly above water.
3. Connect the tubing by attaching the included PVC clear tubing to the unions already attached to
the doser head and we are ready to configure the X1. The intake is the right most tube and the
output to the left when installed facing downwards.
OPERATION
1.
Play or Apple App Store and make sure that the Bluetooth
on our mobile device is set to on.
2. Start the app and click on the upper left-
symbol to let the app scan the surrounding area and find
your X1 pump. All done! Your X1 device is now connected.
3.
Set
Nickname
Confirm
If you have multiple X1 Pumps, you can easily assign
them to different groups to make things a little more
organized. To create or assign an X1 pump to a group,
just tap on the three dots to the right of the X1 pump and
created group name. This feature is great if you have
multiple systems with multiple X1 Pumps.
CALIBRATION
1. After connecting to the X1 Pump, the next step in the process is to calibrate it. Tap on the pump
Settings
-hand
Flow Calibration
2. Prime the line and purge out any excess air. If not, the calibration will be off. Once you see all air
has been purged from the line and water starts to pour out, tap on Stop.
3. Using the included 10ml beaker, insert
Start Adding
The pump will run for 10 seconds and then automatically stop.
4. Enter the volume of liquid in the testing beaker and tap on Complete. For increased accuracy, we
recommend that you calibrate the X1 pump every 4-6 weeks.
DOSING METHODS
The X1 has two methods of operation, Manual for single one-time dosing and Planned for a custom 12
stage, 24 hour dosing schedule.
MANUAL ADD
Manual Add
Main
center of the circle to enter your volume amount in milliliters.
Confirm
Start adding
you a real-time countdown as the solution is being added.
PLANNED ADD
Planned Add allows you to create a more
intricate schedule of up to 12 different time
points in a 24 hour period or to automate a
single dosing on a daily basis at the same
time each day.
To create a new plan, just tap on the pump name you wish to configure
Plan A
At the top of the screen you will see the container section. This is a
really handy section that allows you to approximate how much solution
there is left in the container based on your current dosing schedule. In
order for this to work correctly, you must enter the volume of your
container to the best of your ability.
The next section is the cycle. Here you are able to determine if you want
to dose on a daily basis or as infrequent as once every 31 days.
You can also set the pump to dose on a weekly basis which allows you
to then select which days of the week you want to dose.
To select the days of the week you want to dose, just tap on the day until a blue checkmark is added
to the right side.
The final and bottom section is your actual schedule. Here you can tell the doser to administer a daily
total volume and spread it evenly 12 times in a day.
Plus Symbol
For an automated single dose regimen that repeats itself da
Add Plan
Quick Plan
ANTICHEMICAL INTERFERENCE
The Antichemical interference setting allows you have another plan or pump dosing at the same time,
one pump will delay administering the chemical by 5 minutes to ensure that the two chemicals do not
mix.
Save
right hand corner. The main screen
will now show your entire dosing regimen and is now set to begin dosing.
WARRANTY
We warrant your product against any defect in material and workmanship, under normal use. In the
event a product is found to be defective within the warranty period of one year, we will, at our option,
repair or replace the defective product. The warranty period starts at the day of purchase. For warranty
validation, a proof of purchase must be furnished. This limited warranty applies only to the original
purchaser and is not transferable from the original consumer purchaser.
The followings are excluded from the warranty:
1. Improper use of the device causing malfunction;
2. The device is repaired or modified by an unauthorized person;
3. Uses of non-produced material by our company i.e. pump or tube;
4. Damage by disaster;
5. Improper maintenance causing damage;
6. Use of reagent or sample causing corrosion;
7. Damage by accident or over load;
8. Consumables, such as silicone tube and fuse etc.
To obtain warranty support, you may contact our local technical support. Our technical support will
attempt to diagnose and correct the problem. If the problem cannot be rectified, our technical support
will ask you to return the product. You will be asked to furnish proof of purchase to confirm that the
product is still under warranty.
Kamoer Fluid Tech (Shanghai) Co., Ltd, reserves the right to improve or alter appearance and
technical specifications without notice.