Kaba Mas LA GARD BASIC Series Manager Programming

Text of the manual

3740-2 Deadbolt & 4200 Dual-Handed

swingbolt Lock OPENING THE LOCK 1. Enter valid six (6) digit combination. The lock will signal a valid combination entry with a double signal. 2. Within four (4) seconds, turn the keypad to the open position (clock-wise) if using a deadbolt style lock, or turn the handle to the open position if using a swingbolt style lock. 3. Pull door open. •� Invalid Combination Entry - Lock will signal three (3) times. •� Security Considerations - On safes using more than one lock the swingbolt must lock first. CHANGING MANAGER AND USER COMBINATIONS ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1. Enter “zero” six times. 2. Enter your existing six (6) digit combination one time. 3. Enter your new six (6) digit combination two times. 4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3. 5. Test lock operation several times before closing the door. •� Valid Combination - Double signal after valid six (6) digit combination is entered. •� Invalid Combination - Triple signal indicates the old combination is still valid. CAUTION: When selecting a combination do not use birthday or other predictable data that could give correlation between the user and combination. Keep the combination secret. © copyright 2004-2008 (P/N) 760.128 Rev A�• 12/08 Kaba Mas LLC Page 1 of 2 FEATURES MANAGER COMBINATION (Factory set to 1-2-3- 4-5-6) •� Add/Remove�User •� Enable/Disable�User USER COMBINATION •� Open�Lock •� Change�Combination WRONG TRY PENALTY •� Four�(4)�consecutive�invalid�combinations initiates five (5) minute delay period. LOW BATTERY WARNING •� Repeated�LED�flashing�and�beeping�during opening indicates battery is low and needs immediate replacement. AUDIO AND VISUAL SIGNAL •� Double�signal�-�two�(2)�LED�flashes�and�two�(2) beeps - indicates entry is valid or accepted. •� Triple�signal�-�three�(3)�LED�flashes�and�three�(3) beeps - indicates invalid or not accepted. 4200 Swingbolt Lock 3740-2 Deadbolt Lock 3000 Entry (Swingbolt Only) 3750 Entry SUggESTED�KEypADS: 3715 Entry (Swingbolt Only) 3190 PrivatII (Optional) 3710 Entry (Swingbolt Only)

ADD USER (MANAGER ONLY)

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1. Enter the Manager combination and hold down last digit of combination until the lock signals with two sets of double beeps. 2. Press 1. Lock signals twice. 3. Enter user combination twice. The lock signals twice after each valid entry. 4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3. •� Valid�Combination�Entry�-�Double�signal�after�valid�six�(6)�digit�combination�is�entered. •� Invalid�Combination�Entry�-�Triple�signal�indicates�the�old�combination�is�still�valid.� DISABLE USER (MANAGER ONLY) ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1. Enter the Manager combination and hold down last digit of combination until the lock signals with two sets of double beeps. 2. Press 2. Lock signals once. 3.�User�is�temporarily�disabled.�(User�combination�is�saved�and�will�be�valid�if�reinstated.) 4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3. REINSTATE USER (MANAGER ONLY) ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1. Enter the Manager combination and hold down last digit of combination until the lock signals with two sets of double beeps. 2. Press 1. Lock signals once. 3.�User�is�reinstated. 4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3. DELETE USER (MANAGER ONLY) ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1. Enter Manager combination and hold down last digit of combination until the lock signals with two sets of double beeps. 2. Press 3. Lock signals once. 3.�User�and�combination�are�removed�from�lock.�(Add�User�feature�is�still�available.) 4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3. WRONG TRY PENALTY •� Entry�of�four�(4)�consecutive�invalid�combinations�starts�a�five�(5)�minute�delay�period. � � � -�LED�flashes�red�at�ten�(10)�second�intervals. •� At�the�end�of�the�delay�period,�two�more�consecutive�invalid�combinations�will�restart the five (5) minute delay period. BATTERY LOW WARNING •� Repeated�LED�flashing�and�beeping�during�an�opening�indicates�that�the�battery�is�low and needs immediate replacement. •� Uses�one�(1)�9-Volt�alkaline�battery�only.�(Example:�Duracell™�or�Energizer™�alkaline batteries.) It is recommended that batteries be replaced at least once annually. •� Lock contains a non-volatile memory; even with the batteries removed the lock will retain all programming. For battery replacement instructions, see input unit’s “User Operation” Guide. Mounting instructions available at www.kaba-mas.com. © copyright 2004-2008 (P/N) 760.128 Rev A�• 12/08 Kaba Mas LLC Page 2 of 2

Other Door locks Manuals