Invacare Action Vertic Operation & User’s Manual
Read Online
Read the Invacare Action Vertic Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Invacare® Action Vertic
en
Medium active wheelchair
User Manual
This manual MUST be given to the user of the product.
BEFORE using this product, this manual MUST be read and saved for
future reference.
©2019 Invacare Corporation
All rights reserved. Republication, duplication or modification in whole or in part is prohibited
without prior written permission from Invacare Corporation. Trademarks are identified by ™and ®.
All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise
noted.
1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
1.1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
1.2
Symbols in this manual . . . . . . . . . . . . . . . . . . . . . . . . . .
5
1.3
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
1.4
Limitation of Liability. . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
1.5
Standards and Regulations. . . . . . . . . . . . . . . . . . . . . . . .
6
1.6
Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
1.7
Service life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
2.1
Safety information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
2.2
Safety information on electromagnetic interference . . . . .
9
2.3
Safety information on changes and modifications. . . . . . . 10
2.4
Safety devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.5
Labels and symbols on the product . . . . . . . . . . . . . . . . . 12
3 Components and their functions . . . . . . . . . . . . . . . . . . . . . . 14
3.1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2
Parking brakes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.3
Backrest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.3.1
Backrest cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.4
Armrests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.4.1
Tubular armrest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.5
Leg rests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.5.1
One piece footboard . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.6
Chest and Knee cushions. . . . . . . . . . . . . . . . . . . . . . . . . 18
3.7
Anti-tipper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.8
Push handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.9
Tires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.10
Seat cushion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.1
Posture belt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.2
Table tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.3
Air pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.4
Passive illumination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5 Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.1
Safety information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6 Using the wheelchair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.1
Safety information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.2
Braking during use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.3
Move to/from the wheelchair . . . . . . . . . . . . . . . . . . . . . 27
6.4
Driving and steering the wheelchair. . . . . . . . . . . . . . . . . 28
6.5
Negotiating steps and kerbs . . . . . . . . . . . . . . . . . . . . . . 29
6.6
Going up and down stairs . . . . . . . . . . . . . . . . . . . . . . . . 31
6.7
Negotiating ramps and slopes . . . . . . . . . . . . . . . . . . . . . 32
6.8
Stability and balance when seated. . . . . . . . . . . . . . . . . . 33
6.9
Vertical positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.10
Battery charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
7 Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
7.1
Safety information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
7.2
Folding and unfolding the wheelchair . . . . . . . . . . . . . . . 39
7.3
Lifting the wheelchair . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.4
Removing and fitting the rear wheels . . . . . . . . . . . . . . . 40
8 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
8.1
Safety information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
8.2
Maintenance Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . 42
8.3
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
8.4
Disinfection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
9.1
Safety information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
9.2
Identifying and repairing faults . . . . . . . . . . . . . . . . . . . . 47
10 After Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
10.1
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
10.2
Re-use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
10.3
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
11 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
11.1
Dimensions and weight . . . . . . . . . . . . . . . . . . . . . . . . . 49
Materials. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
11.3
Environmental conditions. . . . . . . . . . . . . . . . . . . . . . . . 50
12 Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
12.1
Inspections performed. . . . . . . . . . . . . . . . . . . . . . . . . . 51
This user manual contains important information about the
handling of the product. To ensure safety when using the
product, read the user manual carefully and follow the
safety instructions.
Note that there may be sections in this document, which are
not relevant to your product, since this document applies
to all available models (on the date of printing). If not
otherwise stated, each section in this document refers to all
models of the product.
The models and configurations available in your country can
be found in the country-specific price lists.
Invacare reserves the right to alter product specifications
without further notice.
Before reading this document, make sure you have the
latest version. You find the latest version as a PDF on the
Invacare website.
If you find that the font size in the printed document is
difficult to read, you can download the PDF version from the
website. The PDF can then be scaled on screen to a font
size that is more comfortable for you.
For more information about the product, for example
product safety notices and product recalls, contact your
Invacare representative. See addresses at the end of this
document.
In case of a serious incident with the product, you should
inform the manufacturer and the competent authority in
your country.
1.2
Symbols in this manual
Symbols and signal words are used in this manual and apply
to hazards or unsafe practices which could result in personal
injury or property damage. See the information below for
definitions of the signal words.
WARNING
Indicates a hazardous situation that could result
in serious injury or death if it is not avoided.
CAUTION
Indicates a hazardous situation that could result
in minor or slight injury if it is not avoided.
IMPORTANT
Indicates a hazardous situation that could result
in damage to property if it is not avoided.
Tips and Recommendations
Gives useful tips, recommendations and
information for efficient, trouble-free use.
This product complies with Directive 93/42/EEC
concerning medical devices. The launch date
of this product is stated in the CE declaration
of conformity.
Manufacturer of the product.
1648806-B.00
5
Invacare® Action Vertic
1.3
Warranty Information
We provide a manufacturer’s warranty for the product
in accordance with our General Terms and Conditions of
Business in the respective countries.
Warranty claims can only be made through the provider
from whom the product was obtained.
1.4
Limitation of Liability
Invacare accepts no liability for damage arising from:
•
Non-compliance with the user manual
•
Incorrect use
•
Natural wear and tear
•
Incorrect assembly or set-up by the purchaser or a
third party
•
Technical modifications
•
Unauthorised modifications and/or use of unsuitable
spare parts
1.5
Standards and Regulations
Quality is fundamental to the company’s operation, working
within the disciplines of ISO 13485.
The vehicle was successfully tested according to international
standards as to its safety. It satisfies the requirements
according to RoHS 2011/65/EU, REACH 1907/2006/EC, EN
12183 including a test for flammability (EN 1021-2 or ISO
8191–2) and ISO 7176–14. It was also tested successfully
according to EN 60529 IPX4 as to its resistance to spray
water, and is therefore well suited for weather conditions
such as typical European weather conditions.
1.6
Intended use
The medium active wheelchair is propelled manually and
should only be used for independent or assisted transport
of a disabled person with mobility difficulties. This manual
wheelchair is intended to provide mobility to persons
ages 15 and up (adolescents and adults) with a maximum
weight capacity of 115 kg. The device is indicated to
provide mobility to persons limited to sitting position. It is
intended for active users who wish to position themselves
vertically during the day for medical or professional reasons.
When used without an assistant, it should only be used by
persons who are physically and mentally able to use the
wheelchair safely (e.g. to propel themselves, steer, brake).
The wheelchair should only be used on level ground and
accessible terrain, as well as indoors.
This medium active wheelchair needs to be
subscribed and fit to your specific health condition.
It is important that you comply with the vertical
positioning protocol (duration, frequency, posture,
maximum verticality angle, …) which has been
prescribed by your physical therapist.
WARNING!
Any other or incorrect use could lead to
hazardous situations.
There are no contraindications known, when using the
wheelchair as intended.
6
1648806-B.00
– In some configurations, the overall dimensions
of the wheelchair when it is ready for use
exceed the authorized limits, the access to
emergency escape routes is not possible.
– In some configurations, the wheelchair exceed
the size recommended for travelling by train
in the EU.
Theft and metal detection systems: in seldom cases
the materials used in the wheelchair may activate
theft and metal detection systems.
1.7
Service life
The expected service life of this product is five years when
used daily and in accordance with the safety instructions,
maintenance intervals and correct use, stated in this manual.
The effective service life can vary according to frequency
and intensity of use.
1648806-B.00
7
Invacare® Action Vertic
2
Safety
2.1
Safety information
This section contains important safety information for the
protection of the wheelchair user and assistant and for safe,
trouble-free use of the wheelchair.
WARNING!
Risk of accidents and serious injury
Accidents with resulting serious injury can occur
if the wheelchair is wrongly adjusted.
– Adjustments at the wheelchair always must be
carried out by an authorized dealer.
WARNING!
Risk due to driving style being unsuitable for
the conditions
There is a risk of skidding on wet ground, gravel
or uneven terrain.
– Always adjust your speed and driving style to
the conditions (weather, surface, individual
ability, etc.).
WARNING!
Risk of injury
In a collision you could sustain injury to parts of
your body that extend beyond the wheelchair
(e.g. feet or hands).
– Avoid an unbraked collision.
– Never drive into an object head-on.
– Drive carefully through narrow passages.
WARNING!
Risk due to wheelchair being out of control
At high speed you could lose control of your
wheelchair and overturn.
– Never exceed a speed of 7 km/h.
– Avoid collisions in general.
WARNING!
Risk of tilting
The position of the rear wheel axle and the angle
of your wheelchair’s backrest are two of the key
adjustments that can affect your stability whilst
sitting in the wheelchair.
– These changes, any front wheels position
and/or angle fork adjustments to the set-up of
your wheelchair must only be performed at the
direction of a competent person who has fully
risk assessed the implication of any changes
to the wheelchair configuration. Therefore,
consult with your distributor.
CAUTION!
Risk of burning
The wheelchair components can heat up when
exposed to external sources of heat.
– Do not expose the wheelchair to strong sunlight
before use.
– Before usage, check all components that
come into contact with your skin for their
temperature.
8
1648806-B.00
Risk of injury during transport
The wheelchair is not approved to be transported
in vehicles, using the ordinary attachment points.
– Do not transfer the wheelchair either occupied
or unoccupied in vehicles using the ordinary
attachment points.
– Transport the wheelchair as luggage, for
example in the trunk of a vehicle.
WARNING!
Wheelchair Tie Down Restraints
– Wheelchair users should NOT be transported in
vehicles of any kind while in wheelchairs. As
of this date, the Department of Transportation
has not approved any tie-down systems for
transportation of a user while in a wheelchair,
in a moving vehicle of any type.
– It is Invacare’s position that users of wheelchairs
should be transferred into appropriate seating
in vehicles for transportation and use be
made of the restraints made available by the
auto industry. Invacare cannot and does not
recommend any wheelchair transportation
systems.
CAUTION!
Risk of getting fingers caught
There is always a risk of getting, e.g. fingers
or arms, caught in the moving parts of the
wheelchair.
– Make sure when activating the folding or
insertion mechanisms of moving parts, such as
the removable axle of the rear wheel, folding
backrest or antitipper, that nothing becomes
caught.
CAUTION!
Risk of tipping
The hanging of additional load (back pack or
similar items) onto your chair backposts can affect
the rearward stability of your chair, especially
when used in combination with recliner backrests.
– Invacare strongly recommend the use of
anti-tippers (available as an option) when using
your backposts with additional load.
2.2
Safety information on electromagnetic
interference
This wheelchair was successfully tested in accordance
with International standards as to its compliance with
Electromagnetic Interference (EMI) regulations. However,
electromagnetic fields, such as those generated by radio and
television transmitters, and cellular phones can influence
the functions of wheelchairs with electric device. Also, the
electronics used in our wheelchairs can generate a low level
of electromagnetic interference, which however will remain
1648806-B.00
9
Invacare® Action Vertic
within the tolerance permitted by law. For these reasons we
ask you to please observe the following precautions:
WARNING!
Risk of malfunction due to electromagnetic
interference
– Do not switch on or operate portable
transceivers or communication devices (such as
radio transceivers or cellular phones) when the
electric device is switched on.
– Avoid getting near strong radio and television
transmitters.
– Adding electrical accessories and other
components or modifying the electric device
in any way can make it susceptible to
electromagnetic interference. Keep in mind
that there is no sure way to determine the
effect such modifications will have on the
overall immunity of the electronic system.
– Report all occurrences of unintentional
movement of the electric device to your
authorized dealer.
2.3
Safety information on changes and
modifications
WARNING!
Risk of serious injury or damage
Use of incorrect or improper replacement
(service) parts may cause injury or damage
– Replacement parts MUST match original
Invacare parts.
– Always provide the wheelchair serial number to
assist in ordering the correct replacement parts.
10
1648806-B.00
Risk of injuries and damage due to unapproved
components and accessory parts
Seating systems, additions and accessory parts
which have not been approved by Invacare for
use with this mobility device can affect the
tipping stability and increase tipping hazards.
– Only ever use seating systems, additions and
accessory parts which have been approved by
Invacare for this mobility device.
Seating systems which are not approved by
Invacare for use with this mobility device do
not, under certain circumstances, comply with
the valid standards and could increase the
flammability and the risk of skin irritation.
– Only use seating systems that have been
approved by Invacare for this mobility device.
Electrical and electronic components which have
not been approved by Invacare for use with this
mobility device can cause fire hazards and lead
to electromagnetic damage.
– Only ever use electrical and electronic
components which have been approved by
Invacare for this mobility device.
Batteries which have not been approved by
Invacare for use with this mobility device can
cause chemical burns.
– Only ever use batteries which have been
approved by Invacare for this mobility device.
CAUTION!
Risk of injuries, and damage, if unapproved
backrests are used
A retrofitted backrest which is not approved by
Invacare for use with this mobility device may
overload the backrest tube and thus increase the
risk of injuries and of damage to the mobility
device.
– Please contact your authorized dealer who will
perform risk analyses, calculations, stability
checks etc. to ensure that the backrest can be
used safely.
CE marking of the mobility device
– The conformity assessment/CE marking was
carried out in accordance with Directive 93/42
EEC and only applies to the complete product.
– The CE marking is invalidated if components or
accessories are replaced or added that have
not been approved for this product by Invacare.
– In this case, the company that adds or replaces
the components or accessories is responsible
for the conformity assessment/CE marking or
for registering the mobility device as a special
design and for the relevant documentation.
1648806-B.00
11
Invacare® Action Vertic
2.4
Safety devices
WARNING!
Risk of accidents
Safety devices that are incorrectly set or no longer
working (brakes, antitipper) can cause accidents.
– Always check that the safety devices are
working before you use the wheelchair and
have them checked regularly by the authorized
dealer.
The functions of the safety devices are described in chapter
Product Overview.
2.5
Labels and symbols on the product
Identification label
The identification label is attached to the frame of your
wheelchair and gives the following information:
A
Manufacturer’s address
B
Product description
C
Date of manufacture
D
CE mark
E
Maximum user weight
F
Part number
G
Serial number barcode
H
Serial number
I
“crossed out wheelie bin”
12
1648806-B.00
Read user manual
Indicates a hazardous situation that could
result in serious injury or death if it is not
avoided.
Snap hook symbols
WARNING Symbol
This wheelchair is not configured for
passenger transport in a motor vehicle. This
symbol is attached to the frame close to the
identification label.
WEEE conform
This product may contain substances that
could be harmful to the environment if
disposed of in places (landfills) that are not
appropriate according to legislation.
The “crossed out wheelie bin” symbol is
placed on this product to encourage you to
recycle wherever possible.
Electrical shock protection
Type B applied part
According to IEC60601–1, comply with
protection against electrical shock specified
requirements
1648806-B.00
13
Invacare® Action Vertic
3
Components and their functions
3.1
Overview
A
Chest cushion
B
Back
C
Rear wheel with handrim
D
Parking brake
E
Frame
F
Front wheel fork with front wheel
G
One piece footboard
H
Knee cushion
I
Seat/Cushion
J
Raising/lowering button
K
Tubular Armrest
Short description
This is a medium active wheelchair with stand up mechanism
and folded backrest.
The equipment of your wheelchair may differ from
the diagram as each wheelchair is manufactured
individually to the specifications in the order.
14
1648806-B.00
Components and their functions
3.2
Parking brakes
The parking brakes are used to immobilize the wheelchair
when it is stationary to prevent it from rolling away.
WARNING!
Risk of overturning if you brake sharply
If you apply the parking brakes while you are
moving, the direction of movement can become
uncontrollable and the wheelchair may stop
suddenly, which can lead to a collision or to you
falling out.
– Never apply the parking brakes while you are
moving.
WARNING!
Risk due to wheelchair being out of control
– The parking brakes must be operated
simultaneously.
– Do not apply the parking brakes to slow down
the wheelchair.
– Do not lean on the parking brakes for support
or transfer.
WARNING!
Risk of overturning
The parking brakes will not operate correctly
unless there is sufficient air in the tires.
– Ensure the correct tire pressure, 3.9 Tires, page
21.
CAUTION!
Risk of pinching or crushing
There may be a very small gap between the rear
wheel and the parking brake with the risk that
you could trap your fingers.
– Keep your fingers away from movable parts
when using the brake, always keep your hand
on the brake lever.
The distance between the brake shoe and the tire
can be adjusted. The adjustment must be carried
out by an authorized dealer.
Standard brake
1.
To apply the brake, push the brake lever forwards as
far as possible.
2.
To release the brake, pull the brake lever backwards.
The lever of the push handle can be folded back to
facilitate transfers. To do so, pull up the lever and
fold it backwards.
1648806-B.00
15
Invacare® Action Vertic
3.3
Backrest
Fixed backrest do not require adjustment.
WARNING!
Risk of tipping
The hanging of additional load (back pack
or similar items) onto your wheelchair back
posts can affect the rearward stability of your
wheelchair. This can cause the chair to tip
backwards causing injury.
– Therefore, Invacare strongly recommend the
use of anti-tippers (available as an option)
when using your back posts with additional
load (back pack or similar items).
3.3.1
Backrest cover
You can adjust the tension of the backrest cover as required.
Adjusting the backrest cover
1.
Remove the backrest cushion A.
2.
Loosen the hook and loop strips B on the rear of the
backrest cover by simply pulling on them.
3.
Tighten or loosen the strips as required then reattach
them.
WARNING!
Risk of tipping
If the bands are set very loose, the tipping point
of your wheelchair is changed for the worse.
– Ensure that the bands are set correctly.
IMPORTANT!
– Do not overtighten the bands; this is to ensure
that the geometry of the wheelchair is not
changed.
3.4
Armrests
WARNING!
The armrest does not engage into the wheelchair.
– Therefore do not hold it in order to lift the
wheelchair.
CAUTION!
Risk of pinching
– Keep your fingers away from movable parts
during removing, fitting or adjusting the
armrest.
16
1648806-B.00
Components and their functions
3.4.1
Tubular armrest
Folding
1.
Apply the parking brake on both sides.
2.
Grip the tubular armrest by the armpad and fold it back.
Setting the height
1.
Loosening the 2 screws A with 5 mm Allen key.
2.
Slide tubular armrest support to the desired height and
firmly tighten the 2 screws (10 Nm) A.
3.
Adjust other side accordingly, if required.
Invacare recommends that tubular armrest adjustment is
carried out by an authorized dealer.
3.5
Leg rests
WARNING!
Risk of injury
– Never lift the wheelchair by the footrest
supports or leg rests.
CAUTION!
Risk of pinching or crushing fingers
There are swing mechanisms where you could
trap your fingers.
– Be careful when using, swinging, disassembling
or adjusting these mechanisms.
IMPORTANT!
Risk of damage to the leg rest mechanism
– Do not place anything heavy, or let children
sit on the leg rest.
3.5.1
One piece footboard
Angle and depth adjustment
The one piece footboard has 2 angle positions.
1648806-B.00
17
Invacare® Action Vertic
1.
Unscrew the lower locking screws A with 4 mm Allen
key.
2.
Remove the upper locking screws A with 4 mm Allen
key, sideways.
3.
Position the one piece footboard assembly into the one
of the two angle positions.
4.
Insert the upper locking screws A into the pre-set holes
and firmly tighten upper and lower screws (10 Nm).
Depth adjustment.
1.
Remove the two locking screws A with 4 mm Allen key,
sideways.
2.
Position the one piece footboard assembly forwards or
backwards to the appropriate depth.
3.
Insert the two locking screws A into the pre-set holes
and firmly tighten the screws (10 Nm).
Height adjustment
The one piece footboard has three height adjustment
options.
1.
Remove calf strap if necessary.
2.
Remove the two locking screws A with 4 mm Allen key,
sideways.
3.
Position the one piece footboard assembly into one of
three preset positions.
4.
Insert the two locking screws A into the pre-set holes
and firmly tighten the screws (10 Nm) into the desired
position.
Invacare recommends that angle and depth adjustment are
carried out by an authorized dealer.
Calf strap adjustment
To ensure a good position of the feet the calf strap
A is attached to the leg rest support and adjustable
by hook and loop fasteners, make sure they perfectly
overlap.
3.6
Chest and Knee cushions
Chest and knee cushions contribute to comfort and good
posture during verticalization.
WARNING!
Risk of falling
Chest and knee cushions that are incorrectly set
or fixed can lead to falling.
– Always check that the cushions are correctly
fitted before using the wheelchair and have
them set or readjusted by an authorized dealer
when required.
18
1648806-B.00
Components and their functions
WARNING!
Risk of discomfort
– When adjusting the tension of the chest strap,
make sure the rib cage is not compressed
based upon user’s morphology.
Always check that hook and loop fasteners are well
positioned and make sure they perfectly overlap.
Chest cushion
Chest cushion A and its strap B installation and assessment,
must be carried out by an authorized dealer.
WARNING!
Risk of injury
– The adjustments of the chest cushion must be
carried out by an authorized dealer.
Knee cushion
Knee cushion C and its strap D installation and assessment,
must be carried out by an authorized dealer.
WARNING!
Risk of injury
– The adjustments of the knee cushion must be
carried out by an authorized dealer.
These adjustments are required with reference to the
user’s morphology and his particular physical limits.
Make sure that the knee cushion is fitted correctly
on each side. The fixations E must be locked into
position.
3.7
Anti-tipper
An anti-tipper prevents the wheelchair from tipping
backwards.
WARNING!
Risk of overturning
Anti-tippers that are incorrectly set or no longer
working can lead to overturning.
– Always check that the anti-tipper is working
before using the wheelchair and have it set
or readjusted by an authorized dealer when
required.
– In some configurations, the static stability of
the wheelchair may be lower than 10°; Invacare
strongly recommends the use of anti-tipper
(available as an option).
1648806-B.00
19
Invacare® Action Vertic
WARNING!
Risk of overturning
On uneven or soft ground, the anti-tipper can sink
into potholes or directly into the ground, thereby
curtailing or eliminating its safety function.
– Only use the anti-tipper when travelling on
even and firm ground.
Anti–tipper installation
Anti-tipper A installation must be carried out by an
authorized dealer.
WARNING!
Risk of tipping
An activated anti-tipper can catch when
negotiating a step or an edge.
– Only use the anti-tipper when travelling on
level ground and flat surfaces.
Setting the height
WARNING!
Risk of overturning
– The adjustments of the anti-tipper must be
carried out by an authorized dealer.
This adjustment is required with reference to the
position and diameter of the rear wheel as well as
the user conditions and his particular safety limits.
Make sure that the anti-tipper device is fitted
correctly on each side. The fixations B must be
locked into position.
3.8
Push handle
IMPORTANT!
– Always check the push handles before using
the wheelchair, as to whether the hand grips
are secure, cannot be turned and cannot be
pulled off.
CAUTION!
If the fixing screws are not correctly tightened,
the push handle could accidentally come off the
backrest tube while pushing it upwards.
– Make sure that the fixation is firmly tightened.
Push handle installation
Push handles A installation must be carried out by an
authorized dealer.
20
1648806-B.00
Components and their functions
3.9
Tires
The ideal pressure depends on the tire type:
Tire
Max.
pressure
Solid tire: 610 mm (24”)
-
-
-
Pneumatic tire:
610 mm (24”)
4 bar
400 kPa
58 psi
Non marking pneumatic
tire: 610 mm (24”)
7 bar
700 kPa
101 psi
Solid tire: 150 mm (6”)
-
-
-
The compatibility of the tires listed above depends on
the configuration and/or model of your wheelchair.
The size of the tire is mentioned on the sidewall of
the tire. The change of appropriate tires must be
carried out by an authorized dealer.
CAUTION!
– The tires pressure have to be equal in both
wheels to avoid a less driving comfort, to keep
the brakes efficiency and an easy propelling of
the wheelchair.
3.10
Seat cushion
A suitable cushion is recommended to provide an even
pressure distribution on the seat.
CAUTION!
Adding a cushion to the seat will raise your
height above the ground and can affect your
stability in all directions. If a cushion is changed
it may also change the user’s stability. If the
thickness of the cushion is changed, a complete
set up of the wheelchair need to be done by an
authorized dealer.
– We recommend to use an Invacare or Matrx
cushion with anti-slip base cover in order to
prevent sliding.
1648806-B.00
21
Invacare® Action Vertic
4
Accessories
4.1
Posture belt
The wheelchair can be equipped with a posture belt. It
prevents the user from sliding downward in the wheelchair
or from falling out of the wheelchair. The posture belt is
not a positioning device.
WARNING!
Risk of serious injury / strangulation
A loose belt can allow the user to slip down and
create a risk of strangulation.
– The posture belt should be mounted by
a qualified technician and fitted by the
responsible prescriber.
– Always make sure that the posture belt is
tightly fitted across the lower pelvis.
– Each time the posture belt is used, check if it
fits properly. Changing the seat and/or backrest
angle, the cushion and even your clothes
influence the fit of the belt.
Closing and opening the posture belt
Ensure that you are sitting fully back in the seat and that
the pelvis is as upright and symmetrical as possible.
1.
To close, push the catch A into the buckle clasp B.
2.
To open, push the Press button C and pull the catch A
out of the buckle clasp B.
Adjusting the length
The posture belt has the good length, when there’s
just sufficient space for a flat hand between body
and belt.
22
1648806-B.00
Shorten or extend the loop D as required.
2.
Thread loop D through catch A and plastic buckle E
until the loop is flat.
If this adjustment is not sufficient, it might be required to
re-fit the posture belt at the fixations.
Fitting the posture belt at the fixations
CAUTION!
– Thread the belt loop through both plastic
buckles to avoid the belt from loosening.
– Do the adjustments on both sides equally,
so that the buckle clasp remains in a central
position.
– Make sure that the belts do not get caught in
the spokes of a rear wheel.
1.
Thread the loop F through the fixation on the chair G
and then through BOTH plastic buckles H.
4.2
Table tray
WARNING!
Risk of tipping / injury
– Max load on the table: 5 kg
CAUTION!
Risk of discomfort / minor bruises
– Make sure that the elbows of the user
are placed on the table when pushing the
wheelchair. If the elbows protrudes from the
table while pushing the wheelchair, there is a
risk of discomfort or minor bruises.
Table tray installation
Table tray A installation must be carried out by an
authorized dealer.
Depth adjustment
Slide the table tray A forwards or backwards to adjust to
the required depth.
1648806-B.00
23
Invacare® Action Vertic
CAUTION!
Risk of discomfort
– When adjusting the depth of the table, make
sure not to squeeze the stomach of the user.
The table tray A reduces accessibility to the
raising/lowering button.
4.3
Air pump
The air pump is fitted with a universal valve connection.
Using the correct valve connection depends of the inner
tube valve type.
1.
Remove the dust cap from the valve connection.
2.
Push the valve connection onto the open valve on the
wheel and pump the wheel up.
There are two types of pumps available:
•
Low pressure <6 bars
•
High pressure >6 bars
Instruction for use printed on the packaging.
4.4
Passive illumination
You can attach reflectors to the rear wheels.
24
1648806-B.00
Risk of injury
– Before using the wheelchair, check its
general condition and its main functions, 8.2
Maintenance Schedule, page 42.
Your authorized dealer will supply your wheelchair ready for
use. Your dealer will explain the main functions and ensure
that the wheelchair meets your needs and requirements.
Adjustments of the axle position and the front wheel
supporters must be carried out by an authorized dealer.
If you receive your wheelchair folded, please read section
7.2 Folding and unfolding the wheelchair, page 39.
1648806-B.00
25
Invacare® Action Vertic
6
Using the wheelchair
6.1
Safety information
WARNING!
Risk of accidents
Uneven tire pressure can have a huge effect on
handling.
– Check the tire pressure before each journey.
WARNING!
Risk of falling out of the wheelchair
When using too small front wheels the wheelchair
could get stuck at curbs or in floor grooves.
– Make sure that the front wheels are suitable
for the surface you’re driving on.
CAUTION!
Risk of crushing
There may be a very small gap between the rear
wheel and the mudguard/ armpad with the risk
that you could trap your fingers.
– Ensure that you always propel your wheelchair
using the handrims only.
CAUTION!
Risk of crushing
There may be a very small gap between the rear
wheel and the parking brake with the risk that
you could trap your fingers.
– Ensure that you always propel your wheelchair
using the handrims only.
26
1648806-B.00
Using the wheelchair
6.2
Braking during use
Whilst you are moving, you brake by transferring force to
the handrim with your hands.
WARNING!
Risk of overturning
If you apply the parking brakes while you are
moving, the direction of movement can become
uncontrollable and the wheelchair may stop
suddenly, which can lead to a collision or to you
falling out.
– Never apply the parking brakes while you are
moving.
CAUTION!
Risk of burning your hands
If you brake for a long time, a lot of frictional
heat is produced at the handrims (especially anti
slip handrims).
– Wear suitable gloves.
1.
Hold the handrims and press evenly with both hands
until the wheelchair stops.
6.3
Move to/from the wheelchair
WARNING!
Risk of overturning
There is a high risk of overturning during the
transfer.
– Only get in and out without assistance if you
are physically able to do so.
– When transferring, position yourself as far
back as possible in the seat. This will prevent
damaged upholstery and the possibility of the
wheelchair tipping forward.
– Make sure that both castors are facing straight
to the front.
WARNING!
Risk of overturning
The wheelchair could tip forwards if you stand
on the footrest.
– Never stand on the footrest when getting in
and out.
CAUTION!
If you release or damage the brakes the
wheelchair could roll away out of control.
– Do not support yourself on the brakes when
getting in and out.
1648806-B.00
27
Invacare® Action Vertic
IMPORTANT!
The mudguards and armrests could become
damaged.
– Never sit on the mudguards or armrests when
getting in and out.
1.
Propel the wheelchair as near as possible to the seat
that you want to move to.
2.
Apply the parking brakes.
3.
Remove the armrests or move them upwards out of
the way.
4.
Detach the legrests or swing them outwards (if so
equipped).
5.
Place your feet on the ground.
6.
Hold the wheelchair and, if necessary, also hold a fixed
object in the vicinity.
7.
Move slowly to chair.
6.4
Driving and steering the wheelchair
You drive and steer the wheelchair using the handrims.
Before driving without an assistant you must find your
wheelchair’s tipping point.
WARNING!
Risk of tipping
The wheelchair can tip backwards if it is not fitted
with an antitipper. When finding the tipping
point, an assistant must stand immediately
behind the wheelchair to catch it if it tips over.
– To prevent tipping, install an antitipper device.
WARNING!
Risk of tipping
The wheelchair can tip forwards.
– When setting up your wheelchair, test its
behavior in terms of tipping forward and adjust
your driving style accordingly.
CAUTION!
A heavy load hanging on the backrest can affect
the wheelchair’s centre of gravity.
– Change your driving style accordingly.
28
1648806-B.00
Using the wheelchair
Finding the tipping point
1.
Release the brake.
2.
Roll backwards a short distance, grasp both handrims
firmly and push forwards with a slight kick.
3.
The shift in weight and steering in opposite directions
with the handrims will enable you to identify the tipping
point.
6.5
Negotiating steps and kerbs
WARNING!
Risk of overturning
When negotiating steps you could lose your
balance and tip the wheelchair over.
– Always approach steps and kerbs slowly and
carefully.
– Do not go up or down steps that are higher
than 25 cm.
CAUTION!
An activated anti-tipper prevents the wheelchair
from tipping backwards.
– Deactivate the anti-tipper before going up or
down steps or kerbs.
1648806-B.00
29
Invacare® Action Vertic
Going down a step with an assistant
1.
Move the wheelchair right up to the kerb and hold the
handrims.
2.
The assistant should hold both push handles, place
one foot on the tipper aid (if installed) and tilt the
wheelchair backwards so that the front wheels lift off
the ground.
3.
The assistant should then hold the wheelchair in this
position, push it carefully down the step and then tilt it
forwards until the front wheels are back on the ground.
Going up a step with an assistant
WARNING!
Risk of serious injuries
Going up steps and kerbs frequently can result
in earlier than expected fatigue break of the
wheelchair backrest. The user might fall out of
the wheelchair.
– Always use a tipper aid when going up steps
or kerbs.
1.
Move the wheelchair backwards until the rear wheels
touch the kerb.
2.
The assistant should tilt the wheelchair using both push
handles so that the front wheels lift off the ground,
then pull the rear wheels over the kerb until the front
wheels can be placed back on the ground.
Going down a step without an assistant
30
1648806-B.00
Using the wheelchair
WARNING!
Risk of tipping
When going down a step without an assistant you
could tip over backwards if you cannot control
your wheelchair.
– First learn how to go down a step with an
assistant.
– Learn how to balance on the rear wheels, 6.4
Driving and steering the wheelchair, page 28.
1.
Move the wheelchair right to the kerb, lift the front
wheels and keep the wheelchair balanced.
2.
Now slowly roll both rear wheels over the kerb. While
doing this, hold the handrims firmly with both hands
until the front wheels are back on the ground.
6.6
Going up and down stairs
WARNING!
Risk of overturning
When negotiating stairs you could lose your
balance and overturn your wheelchair.
– Always use two assistants when negotiating
stairs with more than one step.
1.
You can go up and down stairs by taking them one step
at a time, as described above. The first assistant should
stand behind the wheelchair holding the push handles.
The second assistant should hold a solid part of the
front frame to steady the wheelchair from the front.
1648806-B.00
31
Invacare® Action Vertic
6.7
Negotiating ramps and slopes
WARNING!
Risk due to wheelchair being out of control
When negotiating slopes or gradients your
wheelchair could tip backwards, forwards or
sideways.
– Always have an assistant behind the wheelchair
when approaching long slopes.
– Avoid lateral slopes.
– Avoid slopes of more than 7°.
– Avoid jerking when changing direction on a
slope.
CAUTION!
Your wheelchair could run away even on slightly
sloping ground if you do not control it using the
handrims.
– Use the parking brakes if your wheelchair is
stationary on sloping ground.
Going up slopes
To go up a slope, you must create some momentum, keep up
the momentum and control the direction at the same time.
1.
Bend your upper body forwards and propel the
wheelchair with quick, powerful strokes on both
handrims.
32
1648806-B.00
Using the wheelchair
Going down slopes
When going down slopes, it is important to control your
direction and particularly your speed.
1.
Lean back and carefully allow the handrims to run
through your hands. You should be able to stop the
wheelchair at any time by gripping the handrims.
CAUTION!
Risk of burning your hands.
If you brake for a long time, a lot of frictional
heat is produced at the handrims (especially anti
slip handrims).
– Wear suitable gloves.
6.8
Stability and balance when seated
Some everyday activities and actions require you to lean
forwards, sideways or backwards out of the wheelchair. This
has a major effect on the wheelchair’s stability. To keep
your balance at all times, proceed as follows:
Leaning forwards
WARNING!
Risk of falling out
If you lean forwards out of the wheelchair you
could fall out of it.
– Never bend too far forwards and do not shift
forwards in your seat to reach an object.
– Do not bend forwards between your knees to
pick up something off the floor.
1648806-B.00
33
Invacare® Action Vertic
1.
Point the front wheels forwards. (To do this, move your
wheelchair forwards slightly then back again.)
2.
Apply both parking brakes.
3.
When leaning forwards your upper body must remain
over the front wheels.
Reaching backwards
WARNING!
Risk of falling out
If you lean too far backwards you could tip your
wheelchair over.
– Do not lean out over the backrest.
– Use an antitipper device.
1.
Point the front wheels forwards. (To do this, move your
wheelchair forwards slightly then back again.)
2.
Do not apply the parking brakes.
3.
When reaching backwards do not reach so far that you
have to change your sitting position.
6.9
Vertical positioning
WARNING!
Safety procedures
– Always operate both manual brakes to locked
the rear wheels.
– Check that the chest and knee cushions,
posture belt and calf straps used to support
the body, are in place and well adjusted. These
adjustments must be carried by an authorized
dealer.
– Always make sure that no obstacle or persons
(like child) interferes during the raising/lowering
process as there is a risk of serious injury in
case of body jamming in moving mechanical
device.
– Ensure that you have the possibility of calling
for assistance in case of trouble during stand up
process (cell phone or alarm necklace/bracelet
at hand).
CAUTION!
– Not operate the raising/lowering function when
the charger is connected, unless battery is at
very low capacity and cannot drive lowering
operation.
– Battery at its maximum capacity allows about
150 cycles, depending on user’s weight, before
recharging.
34
1648806-B.00
Using the wheelchair
Always make sure that the ground where you want
to stand up is perfectly flat and firm, without
obstacle or object which might damage stability of
the wheelchair and safety of the user.
Seating and standing assessment
Please comply with the vertical positioning protocol which
has been prescribed by your physical therapist. It is
essential that your Action Vertic is perfectly adapted to
your morphology. All necessary adjustments are describe
in the Service Manual, contact your authorized dealer for
complete assessment.
1.
Seat depth adjustment: correct position of center of
knee A, seat depth too short B, seat depth too long C.
2.
Stand up position adjustment: correct alignment of
ankle/knee/hip joint A, knee joint hyper extended B,
incomplete knee extension C.
All the seating and standing assessment, the chest
and knee cushions, posture belt and calf straps
adjustment must be carried out by an authorized
dealer with assistance of a multi-disciplinary team of
qualified health advisors.
Standing up
After applying the safety procedures, you can stand up.
1.
Position your forearms on armrest tubes
2.
Operate raising/lowering button A upwards.
3.
Stand up progressively (in stages) until the prescribed
vertical angle.
The persons around you and yourself will be advised
that you are using the stand up function by a long
“beep” (one tone).
1648806-B.00
35
Invacare® Action Vertic
CAUTION!
Risk of blockage in stand up or seating position.
During standing/seating process, you can break
the raising/lowering button A, this can cause a
overly long blockage in position.
– Do not hit an obstacle with the raising/lowering
button A.
Operate raising/lowering button A upwards to stand up or
downwards to sit back.
Sitting down
1.
Keep your forearms on armrest tubes
2.
Operate raising/lowering button A downwards.
3.
Go down progressively (in stages) to the initial seating
position (beeping will stop).
After no use during 30 minutes, one tone warns you
the setting go in a stand-by mode.
36
1648806-B.00
Using the wheelchair
6.10
Battery charging
Light bars (led) on battery box
display A
A
A
Charging time
First use, even if any led are
lighted
8 hours
The orange led just disappears
5 hours
The red led are lighted, a noise
alerting the battery empty starts
8 hours
WARNING!
Risk of damage the battery
The battery can not reach its optimal load
capacity.
– Do not let in charge the battery more than
10 hours.
WARNING!
Risk of electrocution, explosion and destruction
of the battery or charger
– Always use the charger (HP 1202N2) supplied
with wheelchair as there is a risk of explosion
or destruction of the battery if poor quality or
incompatible charger is used.
– Always protect the charger against humidity as
there is a risk of electrocution and destruction
of the charger if it is wet.
– Do not use the charger if it has been dropped
or damaged as there is a risk of short-circuit
and electrocution.
CAUTION!
Risk of fire and/or injury
– Only use an extension lead if it is absolutely
necessary as there is a risk of fire or injury if a
damage one is used.
– If there is no other choice, make sure the
extension lead is in good condition and
compatible with the charge power.
– Not operate the raising/lowering function when
the charger is connected, unless battery is at
very low capacity and cannot drive lowering
operation.
Battery charge
1.
Connect the charger A using the charger plug B to
the battery box.
2.
Plug the charger into the mains, it starts automatically.
3.
The red light on top of the charger turns orange.
1648806-B.00
37
Invacare® Action Vertic
4.
The warning light on top of the charger is green,
charging is finished.
5.
First unplug the charger from the mains and then the
charger plug B from the battery box.
Warning lights on the top of the charger: red
flashing = low charge load capacity, orange flashing =
tension of the battery in low or overheating. Restart
the charging process from step 1.
Battery box display
Light signals signification
Light bars (led) on battery box
display A
A
A
Battery load level
All the green led are lighted
100%
The first green led disappears
90 – 95%
The orange led disappears, red
led are lighted, a noise alerting
the battery empty starts
5 – 10%
Storage and transport of the battery
Only store battery when it is completely charged.
Battery can be stored at a temperature from – 40°
C to + 65° C. If the battery is stored for more than
four weeks, it must be recharge once a month. This
to keep full charge and prevent any deterioration
by spontaneous discharge.
The wheelchair is equipped with battery which are
not considered as “dangerous equipment”. The
battery conforms to regulation on dangerous goods
air freight (IATA/DGR).
38
1648806-B.00
Risk of injury if the wheelchair is not properly
secured
In the event of an accident, braking manoeuvre,
etc. you may suffer serious injuries from flying
wheelchair parts.
– Always remove the rear wheels when
transporting the wheelchair.
– Firmly secure all wheelchair components in
the means of transport to prevent them from
coming loose during the journey.
IMPORTANT!
Excessive wear and abrasion could affect the
strength of load-bearing parts.
– Do not pull your wheelchair across abrasive
surfaces without the wheels fitted (e.g. pulling
the frame over tarmac).
7.2
Folding and unfolding the wheelchair
The wheelchair has a rigid frame. Nevertheless, the backrest
can be folded forwards.
Folding the wheelchair
1.
Remove the seat cushion, if present.
2.
Loosening both knobs A without forcing.
3.
Position the two tubular armrests close to the backrest
tube.
4.
Pull the backrest upwards and fold it forwards on the
seat.
1648806-B.00
39
Invacare® Action Vertic
Unfolding the wheelchair
CAUTION!
Risk of getting fingers caught
There is a risk of getting your fingers caught
between the tubular armrest and the backrest.
– Never clasp the tubular armrest with your
fingers.
IMPORTANT!
Risk of falling out
– Check that the backrest is completely engaged
on the frame, before using the wheelchair
again.
1.
Position the wheelchair next to you.
2.
Tilt the wheelchair, if possible, gently towards you.
3.
Pull the backrest upwards and push it downwards into
its bracket.
4.
Tightening firmly both knobs A.
5.
Position the two tubular armrests downwards.
7.3
Lifting the wheelchair
IMPORTANT!
– Never lift the wheelchair by removable or
mobile parts (rear wheels, tubular armrests).
– Ensure the backrest posts are securely in place.
1.
Fold the wheelchair, see chapter 7.2 Folding and
unfolding the wheelchair, page 39.
2.
Always lift the wheelchair by gripping the frame at
points A.
Two assistants are required to lift the wheelchair, for
example in the trunk of a vehicle, as the heaviest
part is about 27.2 kg.
7.4
Removing and fitting the rear wheels
WARNING!
Risk of overturning
If the removable axle of a rear wheel is not fully
engaged, the wheel can become loose during
use. This can lead to overturning.
– Always ensure that the removable axles are
fully engaged whenever you fit a wheel.
40
1648806-B.00
Removing the rear wheels
1.
Release the brakes.
2.
With one hand, hold the wheelchair upright.
3.
With the other, hold the wheel through the external
spoke rim around the wheel hub.
4.
Using your thumb, press the removable axle button A.
Keep it pressed and pull the wheel out of the adapter
sleeve B.
Fitting the rear wheels
1.
Release the brakes.
2.
With one hand, hold the wheelchair upright.
3.
With the other, hold the wheel through the external
spoke rim around the wheel hub.
4.
Using your thumb, press the removable axle button and
hold it down.
5.
Push the axle into the adapter sleeve B up to the stop.
6.
Release the removable axle button and make sure that
the wheel is secure.
1648806-B.00
41
Invacare® Action Vertic
8
Maintenance
8.1
Safety information
WARNING!
Some materials deteriorate naturally over time.
This could result in damage to wheelchair
components.
– Your wheelchair should be checked by a
authorized dealer at least once a year or if it
has not been used for a long period.
Your Invacare authorized dealer can provide help
in carrying out regular maintenance. To find an
authorized dealer near you, contact the Invacare
distributor for your country (end of this document).
Packaging for return
The wheelchair shall be sent to the authorized dealer
in an appropriate packaging to avoid damage during
the shipment.
8.2
Maintenance Schedule
To ensure safe and reliable operation, carry out the following
checks and maintenance regularly or have it carried out by
another person.
weekly
monthly
annually
Check the tire
pressure
X
Check rear wheels are
seated correctly
X
Check posture belt
X
Check battery load
level
X
Visual check
X
Check stand up
mechanism
X
Clean front wheels
X
Check bolts
X
Check spokes
X
Check parking brakes
X
Have wheelchair
checked by an
authorized dealer
X
42
1648806-B.00
Check the tire pressure
1.
Check the tire pressure, 3.9 Tires, page 21.
2.
Inflate the tires to the required pressure.
3.
Check the tire tread at the same time.
4.
If necessary, change the tires.
Check rear wheels are seated correctly
1.
Pull on the rear wheel to check that the removable axle
is seated correctly. The wheel should not come off.
2.
If the rear wheels are not engaged properly, remove
any dirt or deposits. If the problem persists, have the
removable axles re-fitted by an authorized dealer.
Check posture belt
1.
Check that the posture belt is adjusted correctly.
IMPORTANT!
– Loose posture belts must be adjusted by an
authorized dealer.
– Damaged posture belts must be replaced by
an authorized dealer.
Check battery load level
1.
Check that the battery load level is at 100%.
Visual check
1.
Examine your wheelchair for loose parts, cracks or other
defects.
2.
If you find anything, have your wheelchair checked
immediately by an authorized dealer.
Check stand up mechanism
1.
Check that the stand up mechanism is easy operating.
Clean front wheels
1.
Check that the front wheels turn freely.
2.
Remove any dirt or hair from the front wheel bearings.
Check the bolts
Bolts can work loose through constant use.
1.
Check that the bolts are tight (on the footrest, seat
cover, sides, backrest, frame, seat module).
2.
Tighten any loose bolts with the suitable torque.
Therefore refer to the Service Manual, available on the
internet at www.invacare.eu.com.
IMPORTANT!
Safety nuts and bolts lose their effectiveness as a
result of repeated loosening and tightening.
– Safety nuts and bolts must be replaced by an
authorized dealer.
Check the spoke tension
The spokes should not be loose or distorted.
1.
Loose spokes must be tightened by an authorized dealer.
2.
Broken spokes must be replaced by an authorized dealer.
Check the parking brakes
1.
Check that the parking brakes are positioned correctly.
The brake is set correctly if the brake shoe depresses
the tire by a few millimeters when the brake is applied.
2.
If you find that the setting is not correct, have the
brakes correctly set by an authorized dealer.
1648806-B.00
43
Invacare® Action Vertic
IMPORTANT!
The parking brakes must be reset after replacing
the rear wheels or changing their position.
Checking after a heavy collision or blow
IMPORTANT!
The wheelchair can sustain visibly undetectable
damage as a result of a heavy collision or hard
blow.
– It is essential to have your wheelchair checked
by an authorized dealer after a heavy collision
or hard blow.
Repairing or changing an inner tube
1.
Remove the rear wheel and release any air from the
inner tube.
2.
Lift one tire wall away from the rim using a bicycle tire
lever. Do not use sharp objects such as a screwdriver
which could damage the inner tube.
3.
Pull the inner tube out of the tire.
4.
Repair the inner tube using a bicycle repair kit or, if
necessary, replace the tube.
5.
Inflate the tube slightly until it becomes round.
6.
Insert the valve into the valve hole on the rim and place
the tube inside the tire (the tube should lie right round
the tire with no creases).
7.
Lift the tire wall over the edge of the rim. Start close to
the valve and use a bicycle tire lever. When doing this,
check all the way round to ensure that the inner tube is
not trapped between the tire and the rim.
8.
Inflate the tire to the maximum operating pressure.
Check that no air is escaping from the tire.
Spare parts
All spare parts may be obtained from an Invacare
authorized dealer. A current list of spare parts is
available on the internet at www.invacare.eu.com.
8.3
Cleaning
Your wheelchair will serve you well for many years if you
clean it regularly.
IMPORTANT!
Sand and seawater can damage the bearings and
steel parts can rust if the surface is damaged.
– Only expose the wheelchair to sand and
seawater for short periods and clean it after
every trip to the beach.
IMPORTANT!
– Do not use coarse abrasives, aggressive cleaning
products or high-pressure cleaners. Never use
acids, alkalines or solvents such as acetone or
cellulose thinner.
– Always use ordinary household cleaning agents.
1.
Clean the cushions and metal parts with a soft, damp
cloth.
2.
Dry the wheelchair carefully with a cloth after using it
in the rain.
3.
If the wheelchair is dirty, wipe off the dirt as soon as
possible with a damp cloth and dry it carefully.
44
1648806-B.00
Regular cleaning will reveal loose or worn parts and
enhance the smooth operation of your wheelchair.
To operate properly and safely, your wheelchair
must be cared for just like any other vehicle. For
upholstery that is severely stained or surface finish
that is badly damaged, contact an authorized dealer
for further information.
Cleaning upholstery
For cleaning upholstery refer to the instructions on the label
on the seat, cushion and backrest cover.
If possible, always overlap hook and loop strips (the
self-gripping parts) when washing, to minimize lint
and thread build-up on hook strips and prevent
damage to upholstery fabric by these.
Cleaning metal surfaces
Hot water and mild detergent on soft cloth should be use
to cleaning metal surfaces.
1.
Wipe down with damp cloth.
2.
Dry surface by wiping down with dry cloth.
Car polish and soft wax can be used to remove abrasions
and restore gloss.
Cleaning plastic surfaces
Plastic surfaces must be cleaned with soft cloth, mild
detergent and hot water.
IMPORTANT!
– Do not use solvents or kitchen cleaners to
clean plastic surfaces.
1.
Rinse surface with clean water.
2.
Dry surface by wiping down with dry cloth.
8.4
Disinfection
The wheelchair may be disinfected by spraying or wiping
with tested, approved disinfectants.
Spray a soft cleaning and disinfecting product
(bactericidal and fungicide meeting the EN1040
/ EN1276 / EN1650 standards) and follow the
instructions given by the manufacturer.
1648806-B.00
45
Invacare® Action Vertic
9
Troubleshooting
9.1
Safety information
Faults may arise as a result of daily use, adjustments or
changing demands on the wheelchair. The table below
shows how to identify and repair faults.
Some of the actions listed must be carried out by a qualified
technician. These are indicated. We recommend that all
adjustments are carried out by a qualified technician.
CAUTION!
– If you notice a fault with your wheelchair, e.g.
a significant change in handling, stop using
your wheelchair immediately and contact your
provider.
46
1648806-B.00
Identifying and repairing faults
Fault
Possible cause
Action
Incorrect tire pressure on one rear wheel
Correct tire pressure, → 3.9 Tires, page 21
The wheelchair does not
travel in a straight line
One or more spokes broken
Replace faulty spoke(s), → authorized dealer
Spokes tightened unevenly
Tighten loose spokes, → authorized dealer
Front wheel bearings are dirty or damaged
Clean or replace the bearings, → authorized
dealer
Incorrect tire pressure in one or both rear
tires
Correct tire pressure, → 3.9 Tires, page 21
The brakes are gripping
poorly or asymmetrically
Brake setting incorrect
Correct the brake setting, → authorized dealer
Tire pressure in rear tires is too low
Correct tire pressure, → 3.9 Tires, page 21
Rolling resistance is very
high
Rear wheels not parallel
Ensure the rear wheels are parallel, → authorized
dealer
Too little tension in front wheel bearing block
Tighten the nut on the bearing block axle slightly,
→ authorized dealer
The front wheels wobble
when moving fast
Front wheel has worn smooth
Change front wheel, → authorized dealer
The front wheel is stiff or
stuck
Bearings are dirty or faulty
Clean or replace the bearings, → authorized
dealer
1648806-B.00
47
Invacare® Action Vertic
10
After Use
10.1
Storage
IMPORTANT!
Risk of damage to the product
– Do not store the product near heat sources.
– Never store other items on top of the
wheelchair.
– Store the wheelchair indoors in a dry
environment.
– Refer to temperature limitation in chapter 11.3
Environmental conditions, page 50.
After long-term storage (more than four months) the
wheelchair must be inspected in accordance to chapter 8
Maintenance, page 42.
10.2
Re-use
The wheelchair is suitable for re-use. The following actions
should be taken:
•
Cleaning and disinfection, 8.3 Cleaning, page 44 and 8.4
Disinfection, page 45 in this manual.
•
Inspection, 8.2 Maintenance Schedule, page 42 in this
manual.
•
The wheelchair should be adapted for the new user in
accordance with the service documentation (available
from the Invacare authorized dealer in your country).
10.3
Disposal
Be environmentally aware and dispose of your wheelchair
properly. Disposal is subject to national and local regulations.
For correct disposal, contact your specialist dealer or
ask your town or district council about local waste
management companies.
48
1648806-B.00
Dimensions and weight
All dimension an weight specifications refer to a wide range
of the wheelchair in a standard configuration. Dimension
and weight (based on ISO 7176–1/5/7) may alter according
to different configurations. In some configurations, the
wheelchair exceed the recommended dimensions for a
wheelchair.
Electrical system
Raisin/lowering
button
< 5 N (operating force)
Actuator Linak
4500 N
Battery pack
NI-MH 24 V 3.8 Ah (about 150 full
lifts, depends of user’s weight)
Main fuse
24 V T2A/250 V
Insulation class
Class II equipment
Protection class
IPX4 , the electrical system is
protected against spray water
Charger HP 1202N2
Output voltage
24 V DC
Voltage supply
100 – 240 V AC 50/60 Hz (1.0 A)
Overall length with leg
rests
840 – 980 mm, one piece
footboard frontwards
915 – 1040 mm, one piece
footboard backwards
Overall width
570 – 670 mm
in increments of 25 mm
Folded length
—
Folded width
—
Folded height
590 – 610 mm
Total mass
from 30.5 kg
Mass of the heaviest part
27.2 kg
Static stability downhill
Static stability uphill
Static stability sideways
23°
7°
16°
Seat plane angle
4°
Effective seat depth
410 – 460 / 460 – 510 mm,
in increments of 25 mm
Effective seat width
380 – 480 mm,
in increments of 50 mm
Seat surface height at
front edge
470 / 520 mm
Seat surface height at rear
edge
430 / 480 mm
Backrest angle (fixed)
0°
1648806-B.00
49
Invacare® Action Vertic
Backrest height
320 / 380 – 480 mm,
in increments of 20 mm
Footrest to seat distance
410 – 460 mm,
in increments of 25 mm
Leg to seat surface angle
75°
Armrest to seat height
150 – 230 mm, step less
Front location of armrest
structure
—
Hand rim diameter
535 mm
Horizontal location of axle
10 – 50 mm
Minimum turning radius
810 mm
Stowage width
400 – 500 mm
Stowage height
500 mm
Stowage length
840 – 1040 mm
Overall length without leg
rests
—
Overall height
820 – 980 mm
Stand up position: from 1360
mm
Maximum user weight
115 kg
Pivot width
1265 mm
Maximum slope angle
brake
7°
11.2
Materials
Frame/backrest tubes
Aluminum, Steel
Upholstery (seat and backrest)
Foam PUR, Fabric Nylon
and Polyester
Push handles
PVC
Plastic parts like brake handles,
clothes guards, foot plates,
armpads and parts of most
accessories
Thermoplastic (e.g.
PA, PP, ABS and PUR)
according to marking
on the parts
Folding mechanism / vertical
brace / clamping parts / castor
forks
Aluminum, Steel
Screws, washers and nuts
Steel
All materials used are protected against corrosion.
We use only REACH and RoHS compliant materials
and components.
11.3
Environmental conditions
Temperature limitation
– 20° C to + 40° C
Relative humidity
20% to 75%
Atmospheric pressure
800 hPa to 1060 hPa
Be aware that when a wheelchair has been stored
under low temperatures, it must be adjusted to
chapter 8 Maintenance, page 42 before use.
50
1648806-B.00
It is confirmed by stamp and signature that all jobs listed in the inspection schedule of the service and repair instructions
have been properly performed. The list of the inspection jobs to be performed can be found in the service manual which is
available through Invacare.
Delivery Inspection
1st Annual Inspection
Stamp of authorized Invacare dealer / Date / Signature
Stamp of authorized Invacare dealer / Date / Signature
2nd Annual Inspection
3rd Annual Inspection
Stamp of authorized Invacare dealer / Date / Signature
Stamp of authorized Invacare dealer / Date / Signature
1648806-B.00
51
Invacare® Action Vertic
4th Annual Inspection
5th Annual Inspection
Stamp of authorized Invacare dealer / Date / Signature
Stamp of authorized Invacare dealer / Date / Signature
52
1648806-B.00
Pencoed Technology Park, Pencoed
Bridgend CF35 5AQ
Tel: (44) (0) 1656 776 222
Fax: (44) (0) 1656 776 220
[email protected]
www.invacare.co.uk
New Zealand:
Invacare New Zealand Ltd
4 Westfield Place, Mt Wellington 1060
New Zealand
Phone: 0800 468 222
Fax: 0800 807 788
[email protected]
www.invacare.co.nz
Ireland:
Invacare Ireland Ltd,
Unit 5 Seatown Business Campus
Seatown Road, Swords, County Dublin
Tel : (353) 1 810 7084
Fax: (353) 1 810 7085
[email protected]
www.invacare.ie
Asia:
Invacare Asia Ltd.
1 Lenton Place, North Rocks NSW 2151
Australia
Phone: (61) (02) 8839 5333
Fax: (61) (02) 8839 5343
[email protected]
www.invacare.com
Australia:
Invacare Australia Pty. Ltd.
1 Lenton Place, North Rocks NSW 2151
Australia
Phone: 1800 460 460
Fax: 1800 814 367
[email protected]
www.invacare.com.au
Invacare France Operations SAS
Route de St Roch
F–37230 Fondettes
France
1648806-B.00
2019-04-10
*1648806B.00*
Making Life’s Experiences Possible®