Cornelius D3030 Operation & User’s Manual
| Brand: | Cornelius |
| Category: | Ice Maker |
| Model: | D3030 (Operation & User’s Manual) |
| File Type: | |
| File Size: | 0.27 Mb |
| Pages: | 18 |
Text of Cornelius D3030 Operation & User’s Manual
PRINTED IN U.S.A
IMI CORNELIUS INC; 1989-95
Ó
Part No 91875.
March, 1997
Revision C
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This Manual must be read and understood before installing or operating this equipment
TABLE OF CONTENTS
Page
SAFETY PRECAUTIONS
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GENERAL DESCRIPTION
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION INSTRUCTIONS
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADJUSTMENT
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Always disconnect power to the dispenser before servicing or cleaning.
Never place hands inside of hopper or gate area without disconnecting power to the dispenser. Agitator rota-
tion occurs automatically when the dispenser is energized!
This ice dispenser has been specifically designed to provide protection against personal injury and eliminates
contamination of ice. To insure continued protection and sanitation, observe the fo
Cornelius D3030 The ice dispenser must be sealed to the counter. The template drawings (page 4) indicate openings which
must be cut in the counter. Locate the desired position for the dispenser, then mark the outline dimensions
and cut out locations using the template drawing. Cut openings in the counter.
Apply a continuous bead of NSF International (NSF) approved silastic sealant (DOW 732 or equal) approxi-
mately 1/4”inside of the
This dispenser is provided with a gate restrictor plate, installed in its’highest position. This plate adjusts the rate
of ice flow from the dispenser. In applications using buckets, carafes or other large containers, the plate may be
removed entirely for maximum ice flow. For glasses and cups, the plate may be adjusted downward to reduce
the flow of ice. The best position depends on the type of ice being used and the size contai
Cornelius D3030 NOTE: shaded area indicates opening in
cabinet bottom needed for utilities
and beverage tubing.
FIGURE 2. MOUNTING TEMPLATES
Fill the hopper with ice and replace the lid. Pushing the dispenser lever will cause ice to flow from the ice chute.
Ice flow will continue until the lever is released. If ice does not dispense see the TROUBLESHOOTING GUIDE
to find the cause.
NOTE:
Use caution to avoid spilling ice when filling dispenser. Immediately clean up any ice spilled
from filling or operating the unit. To prevent contamination of ice, the lid must be
Cornelius D3030 Sanitize the inside of the hopper and agitator with a solution of 1/2 ounce of household bleach in 1 gallon of
water. (200 PPM)
6.
Replace the agitator disk. Sanitize as described in Step 5. Be sure the center screw is replaced and the
screw is tight.
7.
Remove Ice Chute cover as follows:
A.
Flex sides outward to disengage lower pins.
B.
Lift Ice Chute cover to disengage upper pins.
C.
Lower Ice Chute cover down out of unit. Note: it may be help
Cornelius D3030 Should your unit fail to operate properly, check that there is power to the unit and that the hopper contains ice. If
the unit does not dispense, check the following chart under the appropriate symptoms to aid in locating thede-
fect.
Trouble
Probable Cause
BLOWN FUSE OR CIRCUIT BREAKER
A.
Short circuit in wiring.
B.
Defective gate solenoid.
C.
Defective agitator motor.
GATE DOES NOT OPEN AGITATOR DOES
NOT TURN.
A.
No power.
B