Axema Access ControlAB | Box 90215 | 120 23 Stockholm, Sweden | +46 (0)8-722 34 40 | [email protected] | www.axema.se
Codelock A04
A04 is a stand alone codelock designed for in- and outdoor usage
Manual
Updated 11/20/2020
Enter programming code
4
Example- access code 4455 in code slot 1 and five seconds open time.
4
Blocking after invalid code
4
Factory reset
5
Factory settings
5
Technical data and performance
5
2 (5)
ManualA04
Power supply 10-40VDC or 8-35VAC
3-4
Relay output
5-6
Not used
7-8
Timer input
Closing of connector 7 and 8 disables CODE 3.
9-10
Exit button
Depending on type of lock connected to the A04, the supply voltage may need to be increased.
Check voltage at lock if the lock is stoll locked after entering a valid code.
Programming
1. Enter programming mode
Programming mode
l At power up, the unit enters programming mode automatically when the frame is
closed.
l After a valid access, either by code or exit button, the programming mode can be
entered by unlocking, opening and closing of the frame within 45 seconds.
l With programming code from rev. 4.
In programming mode CODE 1 , CODE 2 , CODE 3 and OPEN TIME flashes under the
corresponding function buttons.
2. Enter A090 for normally closed (NC) relay function.
Enter A091 for normally open (NO) relay function.
3. Press the corresponding function button of the code to be changed, added or removed.
4. To erase the code, continue at step 6.
3 (5)
ManualA04
5. Enter the desired code.
6. Press the function button for OPEN TIME.
7. Set desired unlocking time
8. Exit programming mode by pressing B or wait for 30 seconds.
Enter programming code
1. Enter programming mode
2. Press A20 .
3. Enter a six digit programming code twice. A valid entry is confirmed by a beep.
4. Press B to leave programming mode.
The programming code should not contain an access code.
Example- access code 4455 in code slot 1 and five seconds open time.
1. Enter programming mode
2. Press the function button for CODE 1.
3. Enter 4455
4. Press the function button for OPEN TIME.
5. Enter 05
6. Press B to leave programming mode.
Blocking after invalid code
Three invalid codes in a row will block the code lock
Unblocking happens automatically after one minute or after two valid code entries in a row.
4 (5)
ManualA04
1. Enter programming mode
2. Enter A 00199200.
Factory settings
l 7 seconds unlocking time
l No codes
l N/O lock relay function
Technical data and performance
Attribute
A04
Power supply
10-40 VDC/8-35 VAC
Maximum relay load
1A 30VDC
IP-rating
IP55
IP rating
IK08
Temperature range
-30° to +55C°
5 (5)