IntelliSAW IRM-48 Reader

INSTALLATION MANUAL Document: 910.00371.0001 Revision: 1.1 Date: 14 July 2016 Page 1 of 28

IntelliSAW IRM-48 Reader

Installation Manual Page 2 of 28 IRM-48 Reader 910.00371.0001 Copyright © 2016, IntelliSAW IntelliSAW reserves the right to make technical changes or modify the contents of this document without prior notice. IntelliSAW is not responsible for errors or possible lack of information in this document. IntelliSAW reserves all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents, in whole or in part, without prior written consent of IntelliSAW is forbidden. IntelliSAW Rosemount Measurement 100 Burtt Rd. Andover, MA 01810 +1-978-409-1534 WARRANTY These products are warranted to be free from functional defects in material and workmanship at time of manufacture and to conform at that time to the specifications set forth in the relevant instruction manuals or data sheets, for such products for a period of one year. Reference IntelliSAW terms and conditions provided at time of purchase for complete warranty details.

IntelliSAW IRM-48 Reader

Installation Manual Page 3 of 28 IRM-48 Reader 910.00371.0001 IMPORTANT INFORMATION This symbol identifies messages in this document related to safety. DANGER DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury. Failure to follow the instructions given will result in death or serious injury. WARNING WARNING indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury. Failure to follow the instructions given can result in death or serious injury CAUTION CAUTION indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury. Failure to follow these instructions can result in personal injury. NOTICE NOTICE alerts you to practices unrelated to personal injury, such as those that can cause property damage. Failure to follow these instructions can result in property damage. IMPORTANT IMPORTANT indicates additional information about making effective use of this product.

IntelliSAW IRM-48 Reader

Installation Manual Page 4 of 28 IRM-48 Reader 910.00371.0001 TABLE OF CONTENTS 1 Introducing the IRM-48 Reader ........................................................................................... 6 1.1 Models ......................................................................................................................... 6 1.2 Instructions for Use ...................................................................................................... 6 2 Product Overview ................................................................................................................ 7 2.1 System Inputs and Outputs .......................................................................................... 7 2.2 Labeling ....................................................................................................................... 7 2.2.1 Serial ID Label ...................................................................................................... 7 2.2.2 Compliance Label ................................................................................................. 7 2.2.3 Product Label........................................................................................................ 8 2.3 Connectors .................................................................................................................. 8 2.3.1 USB Cable Connector ........................................................................................... 9 2.3.2 Power and Modbus RTU Connector ..................................................................... 9 2.3.3 SMA (RF) Connectors ........................................................................................... 9 2.3.4 Humidity Sensor Connector .................................................................................10 2.4 Power / Feedback LED ...............................................................................................10 3 Installation ..........................................................................................................................11 3.1 Unpacking ...................................................................................................................11 3.2 Dimensions .................................................................................................................12 3.3 Din Rail Mounting .......................................................................................................12 3.3.1 Installation Location .............................................................................................13 3.3.2 Recommended Spacing .......................................................................................13 4 Wiring ................................................................................................................................14 4.1 Power and Modbus RTU Connections ........................................................................15 4.1.1 Power ..................................................................................................................15 4.2 Communication Connections ......................................................................................17 4.3 Humidity Sensor Connections .....................................................................................19 4.4 Air Interface Connections ............................................................................................19 5 Sensor Installation & System Configuration .......................................................................20 5.1 Sensor Installation ......................................................................................................20 5.2 System Configuration ..................................................................................................20 6 System Integration .............................................................................................................21 6.1 Modbus Commands ....................................................................................................21 6.2 Modbus Registers .......................................................................................................22 7 Specifications .....................................................................................................................24

IntelliSAW IRM-48 Reader

Installation Manual Page 5 of 28 IRM-48 Reader 910.00371.0001 8 Product Certifications .........................................................................................................25 8.1 Compliance .................................................................................................................25 8.2 Wireless Certifications ................................................................................................26 8.2.1 Telecommunication Compliance ..........................................................................26 8.2.2 Approved Antennas .............................................................................................26 8.2.3 Federal Communications Commission (FCC) ......................................................26 8.2.4 Industry Canada (IC) ............................................................................................27 9 Contact ..............................................................................................................................28

IntelliSAW IRM-48 Reader

Installation Manual Page 6 of 28 IRM-48 Reader 910.00371.0001 1 INTRODUCING THE IRM-48 READER The IntelliSAW IRM-48 Reader is a remote monitoring unit that provides temperature, partial discharge (PD), and humidity sensing for predictive condition-based monitoring of electrical power critical assets such as switchgear, circuit breakers, and bus ducts. Multiple IRM Readers can be bussed to a CAM-4 system or existing SCADA system providing immediate data display and alarming. 1.1 MODELS This manual covers the following models: • IRM-48-T00: Temperature only monitoring • IRM-48-TP0: Temperature and PD monitoring • IRM-48-T0H: Temperature and Humidity monitoring • IRM-48-TPH: Temperature, PD, and Humidity monitoring 1.2 INSTRUCTIONS FOR USE The IRM-48 Reader is intended for use in the measurement of Temperature, Humidity, Ambient Temperature, Partial Discharge and Surface Discharge of Low to Medium Voltage air insulated Electrical Equipment. Readers connect Air Interfaces through RF cables for wireless interrogation of SAW temperature sensors and Partial Discharge monitoring, while humidity and ambient temperature sensors are wired to the readers. Interfacing to the IntelliSAW CAM-4 or an existing SCADA, DCS, or historian is easily accomplished with industry standard Modbus RTU (RS485 serial). WARNING The Reader is not intended for use in monitoring assets above 40KV The reader is intended to be installed in Low Voltage compartments of switchgear or in similar types of assets; a unit can also be installed in a weather proof environmental enclosure. The unit is intended for use at a maximum altitude of 5km, between -40°C to +70°C and between 10 - 95% non-condensing relative humidity. The reader has been recognized for meeting UL 61010-1 safety requirements for electrical equipment. Please refer to Specifications and Compliance for complete ratings. WARNING The Reader is not intended for installation in asset Medium Voltage or High Voltage Compartments. Only sensors and antennas are intended for installation in medium voltage Compartments.

IntelliSAW IRM-48 Reader

Installation Manual Page 7 of 28 IRM-48 Reader 910.00371.0001 2 PRODUCT OVERVIEW 2.1 SYSTEM INPUTS AND OUTPUTS The maximum system inputs and outputs are as follows: Inputs Outputs 12 temp sensors Communications: Modbus RTU 4 air interfaces (PD / temp) 8 humidity sensors Power: 24V to 60V DC (3.5W) 2.2 LABELING The Reader has two labels on the bottom of the unit, a Serial ID label and a compliance label, and one main product label on the top. 2.2.1 Serial ID Label The IRM-48 Serial ID label provides a model number and serial number for the reader. Figure 1: IRM-48 Model Number and Serial ID Label 2.2.2 Compliance Label The compliance label provides product certification information. Figure 2: IRM-48 Compliance Label

IntelliSAW IRM-48 Reader

Installation Manual Page 8 of 28 IRM-48 Reader 910.00371.0001 2.2.3 Product Label The top product label provides guidance to the model type, product voltage and power ratings, and connector interfaces. Figure 3: Product top label Model identification boxes will be red if the option is available in the reader. 2.3 CONNECTORS The product has up to seven connectors (depending on model): • (1) USB connector – used for configuration • (1) Power and Modbus RTU (RS485) connector • (4) SMA (RF) connectors – used for air interface connections • (1) Ground lug – chassis Function Earth (FE) • (1) Humidity connector – available with humidity option Figure 4: Front and side views of IRM-485 Reader Power & Modbus RTU USB Humidity SMA (RF) Model Identification Voltage and power ratings Ground Lug

IntelliSAW IRM-48 Reader

Installation Manual Page 9 of 28 IRM-48 Reader 910.00371.0001 2.3.1 USB Cable Connector Interface Name Description USB USB USB mini used for unit configuration 2.3.2 Power and Modbus RTU Connector Pin Name Description V+ Power In + Input power range from 24 to 60V DC. V- Power In - Input power range from 24 to 60V DC. FE Functional Earth This pin is used for ground and shield connectivity. Should use separate wire from Case Ground. D-COM DATA Common Common input for Modbus RTU (RS485) DATA- DATA Negative Negative Input for Modbus RTU (RS485) DATA+ DATA Positive Positive Input for Modbus RTU (RS485) 2.3.3 SMA (RF) Connectors Pin Name Description P1 RF Port 1 Air Interface Radio Frequency Port 1 P2 RF Port 2 Air Interface Radio Frequency Port 2 P3 RF Port 3 Air Interface Radio Frequency Port 3 P4 RF Port 4 Air Interface Radio Frequency Port 4 Ground Case Ground Chassis ground lug connection, required for safety when air interfaces are near energized conductors.

IntelliSAW IRM-48 Reader

Installation Manual Page 10 of 28 IRM-48 Reader 910.00371.0001 2.3.4 Humidity Sensor Connector Pin Name Description H-PWR Humidity Power Humidity Cable Power Input from Humidity Sensor H-DAT Humidity Data Humidity Cable DATA Input from Humidity Sensor H-CLK Humidity Clock Humidity Cable Clock Input from Humidity Sensor H-COM Humidity Common Humidity Cable Common Input from Humidity Sensor 2.4 POWER / FEEDBACK LED The product has one power / feedback LED. LED States: • No Illumination: No Power • Solid Green: Power, no measurements • Green / Amber toggle: Automated measurements • Fast flashing Amber: Rebooting LED

IntelliSAW IRM-48 Reader

Installation Manual Page 11 of 28 IRM-48 Reader 910.00371.0001 3 INSTALLATION IMPORTANT • The installation instructions are only for the IRM-48 Reader. • It is assumed an Air Interface Antenna, and Sensors have been installed and configured. WARNING INSTALLATION AND CONFIGURATION SHOULD BE PERFORMED ONLY BY PERSONNEL WHO ARE TECHNICALLY COMPETENT AND AUTHORIZED TO DO SO. LOCAL REGULATIONS REGARDING ELECTRICAL INSTALLATION AND SAFETY MUST BE OBSERVED. Failure to follow the instructions given can result in death or serious injury WARNING THE USE OF THIS EQUIPMENT IN A MANNER NOT SPECIFIED IN THIS MANUAL OR BY THE MANUFACTURER MAY IMPAIR PROTECTION OF THE USER AND EQUIPMENT. Failure to follow the instructions given can result in death or serious injury CAUTION THIS EQUIPMENT IS DESIGNED FOR INSTALLATION IN AN ENCLOSURE THAT PROVIDES ADEQUATE PROTECTION AGAINST ELECTRIC SHOCK. Failure to follow these instructions can result in personal injury. 3.1 UNPACKING 1. Remove the product from its packing. Retain the packing for future use, to transport the instrument to a different site or to return it to the supplier for repair/testing. 2. Examine the delivered items for damage or defects. If any are found, contact the courier immediately. 3. In the Box: a. Reader with a pre-installed din rail mounting clip b. Power and Modbus RTU terminal block (6 position 5.08mm Plug)

IntelliSAW IRM-48 Reader

Installation Manual Page 12 of 28 IRM-48 Reader 910.00371.0001 3.2 DIMENSIONS The IRM-48 instrument has dimensions of 81 H × 142.5 W x 51.5 mm D (3.19 H × 5.61 W × 2.03 in D). Figure 5: IRM-48 Dimensions (in mm) 3.3 DIN RAIL MOUNTING CAUTION ENSURE THE INSIDE OF THE PANEL IS WITHIN THE READER’S OPERATING TEMPERATURE AND THAT THERE IS ADEQUATE AIR FLOW TO PREVENT OVERHEATING. The IRM-48 Reader is mounted on standard 35 mm din rail. It can be mounted either vertically or horizontal by changing the orientation of the mounting clip. The din rail mounting clip is located on the back of the IRM-48 Reader and is screwed on to the frame. The clip is normally oriented for vertical installation of the reader on to a din rail. To change the installation mounting orientation, remove the 2 screws holding the mounting clip to the frame of the reader. Once removed, turn the mounting clip 90 degrees in the desired direction and screw on the mounting clip to the two additional tapped holes on the frame of the reader.

IntelliSAW IRM-48 Reader

Installation Manual Page 13 of 28 IRM-48 Reader 910.00371.0001 Figure 6: Horizontally Installed Din Rail Mounted Reader Figure 7: Vertically Installed Din Rail Mounted Reader 3.3.1 Installation Location The IRM-485 Reader is intended for installation in LV compartments of switchgear, other electrical assets, or in weather protected enclosed locations. The Reader is required to be installed within 7m of the Air Interface, the maximum length of the Air Interface Antenna RF cable. 3.3.2 Recommended Spacing It is recommended to allow up to 5 cm (2 in.) for the IRM-48 Reader connectors. It is best to have the USB connector easily accessible.

IntelliSAW IRM-48 Reader

Installation Manual Page 14 of 28 IRM-48 Reader 910.00371.0001 4 WIRING WARNING SYSTEM WIRING SHOULD BE PERFORMED ONLY BY PERSONNEL WHO ARE TECHNICALLY COMPETENT AND AUTHORIZED TO DO SO. LOCAL REGULATIONS REGARDING ELECTRICAL INSTALLATION AND SAFETY MUST BE OBSERVED. Failure to follow the instructions given can result in death or serious injury WARNING TO AVOID ELECTRICAL SHOCK. AC POWER WIRING MUST NOT BE CONNECTED TO THE SOURCE UNTIL ALL WIRING CONNECTIONS PROCEDURES ARE COMPLETED. Failure to follow the instructions given can result in death or serious injury WARNING CHECK THE INFORMATION LABEL ON THE CASE TO DETERMINE THE CORRECT VOLTAGE BEFORE CONNECTING TO A LIVE SUPPLY. Failure to follow the instructions given can result in death or serious injury IMPORTANT The wiring diagram below shows all possible combinations. The actual connections required depend upon your system installation. The Reader terminal connections are illustrated in the figure below. In general, all wiring connections are made to the instrument after it is installed.

IntelliSAW IRM-48 Reader

Installation Manual Page 15 of 28 IRM-48 Reader 910.00371.0001 Power Supply V+ V- Modbus RTU D-COM DATA - DATA + Humidity Sensor M12 Connector Laptop AIR INTERFACE ANTENNA AIR INTERFACE ANTENNA AIR INTERFACE ANTENNA AIR INTERFACE ANTENNA Figure 8: IRM-48 Connections and Common Wiring 4.1 POWER AND MODBUS RTU CONNECTIONS The IRM-48 Reader uses a single connector for power and Modbus RTU communication. The Connector is a 6 position Male connector. The connector accepts 16-26 AWG wire. It is recommended that Ferrules be used for all terminating wires. V+ V- FE D-COM DATA - DATA + 24V - 60V DC Power Supply V+ V- Modbus RTU D-COM DATA - DATA + Figure 9: Power and Modbus RTU Connections 4.1.1 Power The IRM-48 Reader operates at 48VDC nominal power, but can operate between 24 to 60V DC with a total power consumption of 3.5 W. The following block diagram outlines the recommended power wiring for the IRM-48 Reader with a 2-pole circuit breaker and AC/DC power supply. Surge suppression devices can also be installed on the input line and neutral if higher safety rating is required.

IntelliSAW IRM-48 Reader

Installation Manual Page 16 of 28 IRM-48 Reader 910.00371.0001 AC/DC Power Supply N L V+ V- N L Input Power 2-pole Circuit Breaker 1 3 2 4 IntelliSAW Reader V+ V- FE Low-voltage Compartment FE Figure 10: IntelliSAW Reader Recommended Power Wiring 4.1.1.1 Local versus bussed DC power IntelliSAW recommends the use of a DC power supply in the same low-voltage compartment as the reader. This is the simplest and most flexible option. It is possible to run a DC power bus alongside the RS485 bus, however, this option requires careful consideration of the wire diameter. This method also increases the likelihood of EFT or surge voltages along the DC bus. 4.1.1.2 DC power wire diameter considerations Power connections are recommended to be a minimum 18 AWG, tin-coated, soft drawn copper per ASTM B8, Class B stranding, 300V rated. Insulation shall be EP (ethylene propylene) or EPCP (ethylene propylene chlorosulfonated polyethylene compound). If bussed power is being considered, the wire gauge must be selected to prevent excessive voltage drop between the DC power source and the reader that is electrically farthest from the source. The larger wire diameter required could force the use of a custom cable for DC power as the power bus wire cannot be the same gauge as the communications bus (RS485). Most standard RS485 bus installations use wire diameters of about 0.5mm or 24 AWG; this wire size may be too small to properly support DC power to all the readers if there are many readers a bus. 4.1.1.3 Functional Earth wiring Functional earth (FE) connection should always be installed between the reader’s FE terminal, FE post, and the FE connection in the low-voltage compartment. FE at the cable connection shunts transients at the cables, while case ground provides both RF shielding and safety against induced voltages on air interface cables.

IntelliSAW IRM-48 Reader

Installation Manual Page 17 of 28 IRM-48 Reader 910.00371.0001 IMPORTANT There are two INDEPENDENT connections that shall be individually wired to the Protective Earth of the installation site such that there is an extremely low impedance between the enclosures; this is best achieved using the shortest possible ground cable. 4.2 COMMUNICATION CONNECTIONS The IntelliSAW readers are connected in a network using a standard, half-duplex RS485 bus. This is a 3-wire bus, differential signals for data +/- and a common signal return. The common signal is clamped to PE for safety and connects to the line driver through a high resistance to prevent ground loops. The figure below shows the various elements of a network in a switchgear substation. Figure 11: RS485 Data Communication Bus Topology 4.2.1.1 Recommended Cabling IntelliSAW recommends the use of shielded cable for the RS485 wiring, providing at least one twisted pair, one single line, and a drain wire, although typical cable has two twisted pair. The twisted pair provides DATA+/- signals to each reader while the single line would be for D-COM, providing a low-impedance return for each reader. 4.2.1.2 Bus cable shielding The drain wire associated with the RS485 bus shielding foil should be connected to the protective earth at the source end (the end of the line segment closest to the bus master) with the destination end left unconnected. This prevents ground loops and induced noise. Each

IntelliSAW IRM-48 Reader

Installation Manual Page 18 of 28 IRM-48 Reader 910.00371.0001 segment of the bus should be shield-terminated to the protective earth in the cabinet from which it originates. 4.2.1.3 Bus resistive termination The RS485 bus needs to be terminated at each end with 120 Ω resistors when long stretches of cable are used. This ensures that the bus has the correct impedance. In general, RS485 adapters and bus masters provide the source impedance internally and should be located at one end of the bus. If the bus length is less than 2% of the maximum (20 meters at 9600 baud), the termination resistor may be omitted, as long as the bus master has termination and failsafe resistors. 4.2.1.4 Bus data rate (baud rate) considerations The RS485 bus data rate is dependent on the bus cable length and the number of readers on the bus. In industrial environments, slower data communication rates are generally more reliable; IntelliSAW recommends either 19200 baud or 9600 baud for the data rate. Bus length Bus cable length has an impact on the overall data rates which can be achieved. A conservative rule for RS485 uses the equation: (baud rate * cable length (m)) < 10 x 106. A 9600 baud network would require a bus less of (10 x 106 ÷ 9600), or 1042 meters (about 3400 feet). This is perfectly adequate for most substation installations. Number of Readers As the number of readers increase on the RS485 bus, the baud rate must be adjusted to accommodate the electrical characteristics of the communication protection circuits. The following table is a guide for number of readers versus system baud rate: Readers Baud Rate 1 115,200 1 – 8 38,400 1 – 16 19,200 1 – 32 9,600

IntelliSAW IRM-48 Reader

Installation Manual Page 19 of 28 IRM-48 Reader 910.00371.0001 4.3 HUMIDITY SENSOR CONNECTIONS The Humidity Sensor Connector is a 4 position male connector. The connector accepts 16-26 AWG wire. It is recommended that Ferrules be used for all terminating wires. The IntelliSAW Humidity sensor is shipped with a cable assembly. H-PWR H-DAT H-CLK H-COM M12 Connector HUMIDITY SENSOR Figure 12: Humidity Connector 4.4 AIR INTERFACE CONNECTIONS The IRM-48 Reader supports up to 4 Air Interface Antenna connections (P1-P4). The Air Interface Antenna connections on the Reader are female SMA connections. The Air Interface Antenna’s connect to the Reader through RF cables with Male SMA Connectors on each end. RF Cables are provided by IntelliSAW when purchasing air interfaces. Only IntelliSAW provided antennas are suitable for the desired performance and for compliance with transmitter authorizations.

IntelliSAW IRM-48 Reader

Installation Manual Page 20 of 28 IRM-48 Reader 910.00371.0001 5 SENSOR INSTALLATION & SYSTEM CONFIGURATION 5.1 SENSOR INSTALLATION This manual does not cover specific sensor installation. Please reference the IntelliSAW Sensor Installation Manual for more detail. 5.2 SYSTEM CONFIGURATION The Reader requires system configuration for the associated installed temperature sensors, air interfaces, and humidity sensors. Configuration is performed through the USB port and uses the IntelliSAW Measurement Configuration Software. Details will not be discussed here, please refer to the Configuration Software User Manual for detailed instructions. Figure 13: IntelliSAW System Configuration Software

IntelliSAW IRM-48 Reader

Installation Manual Page 21 of 28 IRM-48 Reader 910.00371.0001 6 SYSTEM INTEGRATION The IRM-48 Reader has one RS485 slave communication connection. The Reader can be connected to a CAM-4 unit or an existing SCADA, DCS, or historian system. All IRM-48 readers are slave devices polled by either a Master CAM-4 unit or SCADA system. The following Modbus information is for Reader Firmware rev.1123 or higher. For legacy Modbus Register data, please contact IntellISAW support. 6.1 MODBUS COMMANDS The Reader treats holding and input registers identically; however HOLDING registers are the preferred approach. Modbus-RTU payloads always begin with the address and a function code (FC). The Reader supports the following Modbus function codes, as shown in the following table: Command FC Description 2 Function code required by CiTect MBF_READHOLDING 3 Fetch up to 81 of 256 defined registers MBF_READINPUT 4 Exactly duplicates the MBF_READHOLDING command with the same registers MBF_PRESETSINGLE 6 Set a single register – do not use in reserved registers MBF_DIAGNOSTICS 7 Sub-functions supported are 1, 4, 10-14 MBF_FETCH_CEC 11 Return 0x0000 if not busy, 0xFFFF if busy MBF_PRESETMULTIPLE 16 Set up to registers MBF_RESET_COMM 19 Reset reader processor if successful. MBF_RESET_COMM_ISR 7E
<7E> <55> resets reader XMS_XMESSAGE_FC 7F The remainder of the payload contains a native command. Modbus-RTU payloads obey the MODICON standard except for special function codes, 7E and 7F. For the 0x7F function code, the payload begins with address and 0x7F followed by an IntelliSAW native protocol command payload. The MBF_RESET_COMM_ISR command is a special sequence that reboots the processor from within the serial receive interrupt service routine, regardless of protocol, when it is detected from a serial line idle condition. The MBF_RESET_COMM_ISR command must be properly formatted and successfully parsed. This special sequence offers a means of resetting a reader that is otherwise externally unresponsive.

IntelliSAW IRM-48 Reader

Installation Manual Page 22 of 28 IRM-48 Reader 910.00371.0001 6.2 MODBUS REGISTERS Note: table items highlighted in blue are not yet implemented. REGISTER DESCRIPTION TYPE MIN MAX SCALE ERROR CODE 418 1 temp 1 signed 16 -500 1675 0.1 C 0x8000 419 temp 2 signed 16 -500 1675 0.1 C 0x8000 420 temp 3 signed 16 -500 1675 0.1 C 0x8000 421 temp 4 signed 16 -500 1675 0.1 C 0x8000 422 temp 5 signed 16 -500 1675 0.1 C 0x8000 423 temp 6 signed 16 -500 1675 0.1 C 0x8000 424 temp 7 signed 16 -500 1675 0.1 C 0x8000 425 temp 8 signed 16 -500 1675 0.1 C 0x8000 426 temp 9 signed 16 -500 1675 0.1 C 0x8000 427 temp 10 signed 16 -500 1675 0.1 C 0x8000 428 temp 11 signed 16 -500 1675 0.1 C 0x8000 429 temp 12 signed 16 -500 1675 0.1 C 0x8000 430 ambient 1 signed 16 -400 1250 0.1 C 0x8000 431 RH 1 unsigned 162 0 1000 0.1% RH 0xFFFF 432 ambient 2 signed 16 -400 1250 0.1 C 0x8000 433 RH 2 unsigned 16 0 1000 0.1% RH 0xFFFF 434 ambient 3 signed 16 -400 1250 0.1 C 0x8000 435 RH 3 unsigned 16 0 1000 0.1% RH 0xFFFF 436 ambient 4 signed 16 -400 1250 0.1 C 0x8000 437 RH 4 unsigned 16 0 1000 0.1% RH 0xFFFF 438 ambient 5 signed 16 -400 1250 0.1 C 0x8000 439 RH 5 unsigned 16 0 1000 0.1% RH 0xFFFF 440 ambient 6 signed 16 -400 1250 0.1 C 0x8000 441 RH 6 unsigned 16 0 1000 0.1% RH 0xFFFF 442 ambient 7 signed 16 -400 1250 0.1 C 0x8000 443 RH 7 unsigned 16 0 1000 0.1% RH 0xFFFF 444 ambient 8 signed 16 -400 1250 0.1 C 0x8000 445 RH 8 unsigned 16 0 1000 0.1% RH 0xFFFF 446 SD1 Total unsigned 16 0 65534 10 "Quhf"3 0xFFFF 447 SD2 Total unsigned 16 0 65534 10 "Quhf " 0xFFFF 448 SD3 Total unsigned 16 0 65534 10 "Quhf " 0xFFFF 449 SD4 Total unsigned 16 0 65534 10 "Quhf " 0xFFFF 450 PD1 Total unsigned 16 0 65534 10 "Quhf " 0xFFFF 451 PD2 Total unsigned 16 0 65534 10 "Quhf " 0xFFFF 452 PD3 Total unsigned 16 0 65534 10 "Quhf " 0xFFFF 453 PD4 Total unsigned 16 0 65534 10 "Quhf " 0xFFFF 454 Data version = 1 unsigned 16 0 65534 na 0xFFFF 455 noise 1 unsigned 16 0 65534 10 "Quhf " 0xFFFF 1 Registers start at 0. 418 is 400418 or 0x01A2 in the datagram. 2 RH may be treated as signed 16 making the error code translate to a small negative number. 3 Partial discharge and surface discharge are nonlinear, and the scale is approximate.

IntelliSAW IRM-48 Reader

Installation Manual Page 23 of 28 IRM-48 Reader 910.00371.0001 456 surface 1 unsigned 16 0 65534 10 "Quhf " 0xFFFF 457 internal 1 unsigned 16 0 65534 10 "Quhf " 0xFFFF 458 noise 2 unsigned 16 0 65534 10 "Quhf " 0xFFFF 459 surface 2 unsigned 16 0 65534 10 "Quhf " 0xFFFF 460 internal 2 unsigned 16 0 65534 10 "Quhf " 0xFFFF 461 noise 3 unsigned 16 0 65534 10 "Quhf " 0xFFFF 462 surface 3 unsigned 16 0 65534 10 "Quhf " 0xFFFF 463 internal 3 unsigned 16 0 65534 10 "Quhf " 0xFFFF 464 noise 4 unsigned 16 0 65534 10 "Quhf " 0xFFFF 465 surface 4 unsigned 16 0 65534 10 "Quhf " 0xFFFF 466 internal 4 unsigned 16 0 65534 10 "Quhf " 0xFFFF 467 noise 5 unsigned 16 0 65534 10 "Quhf " 0xFFFF 468 surface 5 unsigned 16 0 65534 10 "Quhf " 0xFFFF 469 internal 5 unsigned 16 0 65534 10 "Quhf " 0xFFFF 470 noise 6 unsigned 16 0 65534 10 "Quhf " 0xFFFF 471 surface 6 unsigned 16 0 65534 10 "Quhf " 0xFFFF 472 internal 6 unsigned 16 0 65534 10 "Quhf " 0xFFFF 473 noise 7 unsigned 16 0 65534 10 "Quhf " 0xFFFF 474 surface 7 unsigned 16 0 65534 10 "Quhf " 0xFFFF 475 internal 7 unsigned 16 0 65534 10 "Quhf " 0xFFFF 476 noise 8 unsigned 16 0 65534 10 "Quhf " 0xFFFF 477 surface 8 unsigned 16 0 65534 10 "Quhf " 0xFFFF 478 internal 8 unsigned 16 0 65534 10 "Quhf " 0xFFFF 479 noise 9 unsigned 16 0 65534 10 "Quhf " 0xFFFF 480 surface 9 unsigned 16 0 65534 10 "Quhf " 0xFFFF 481 internal 9 unsigned 16 0 65534 10 "Quhf " 0xFFFF 482 noise 10 unsigned 16 0 65534 10 "Quhf " 0xFFFF 483 surface 10 unsigned 16 0 65534 10 "Quhf " 0xFFFF 484 internal 10 unsigned 16 0 65534 10 "Quhf " 0xFFFF 485 noise 11 unsigned 16 0 65534 10 "Quhf " 0xFFFF 486 surface 11 unsigned 16 0 65534 10 "Quhf " 0xFFFF 487 internal 11 unsigned 16 0 65534 10 "Quhf " 0xFFFF 488 noise 12 unsigned 16 0 65534 10 "Quhf " 0xFFFF 489 surface 12 unsigned 16 0 65534 10 "Quhf " 0xFFFF 490 internal 12 unsigned 16 0 65534 10 "Quhf " 0xFFFF 491 SD1 Num unsigned 16 0 65534 counts 0xFFFF 492 SD2 Num unsigned 16 0 65534 counts 0xFFFF 493 SD3 Num unsigned 16 0 65534 counts 0xFFFF 494 SD4 Num unsigned 16 0 65534 counts 0xFFFF 495 PD1 Num unsigned 16 0 65534 counts 0xFFFF 496 PD2 Num unsigned 16 0 65534 counts 0xFFFF 497 PD3 Num unsigned 16 0 65534 counts 0xFFFF 498 PD4 Num unsigned 16 0 65534 counts 0xFFFF

IntelliSAW IRM-48 Reader

Installation Manual Page 24 of 28 IRM-48 Reader 910.00371.0001 7 SPECIFICATIONS TEMPERATURE Operating Frequency 425 to 442 MHz SAW Sensors up to 12 Redundancy Model Up to 4 redundant antennas RF Transmit Power Pulsed, -6 to + 10 dBm4 RF Receive Sensitivity -86 dBm RF Receive Frequency Stability ± 700 Hz RF Interrogation Distance Up to 1.75 m (2.5 m with TPD air interface) RF Interrogation Time ≤ 160 mSec PARTIAL DISCHARGE Number of Channels Up to 4 IntelliSAW CAM Air Interfaces (TPD) Measurement Method Ultra-High Frequency (UHF) Selectable Bands (Center Frequency) 300MHz, 600MHz, or 1200MHz Measurement Types Noise Floor, Surface Discharge (Corona), Internal Discharge (PD) Measurement Scale nonlinear scale, capability to calibrate to reference source Sensitivity 100pC Qpk demonstrated in 24kV switchgear, installation dependent. Response Time 100 mSec HUMIDITY Number of Channels Up to 8 IntelliSAW IH-10 sensors (bussed) Measurement Types Relative Humidity, Ambient Temperature COMMUNICATION INTERFACES Data Bus Interface RS485 (half duplex) Data Bus Baud Rate 4800, 9600, 19200, 38400, 57600, or 115200 baud Data Protocol Modbus-RTU device Response Time 500 mSec or longer timeout recommended. (typically < 100 mSec) Configuration Interface USB Configuration Protocol IntelliSAW Native PHYSICAL Operating Power 48 Vdc typical (24 to 60 Vdc), 3.5W Dimensions 81 W × 142.5 L × 46 mm H Weight 0.3 kg (10 oz) International Protection (IEC 60529) IP 20 Mounting Style DIN rail mounted Operating Conditions -40°C to +70°C, 10 - 95% RH non-condensing Elevation Up to 5000m 4 Using administrative settings, levels to -13.5dBm may be attained. FCC modes reduce the maximum power using these settings.

IntelliSAW IRM-48 Reader

Installation Manual Page 25 of 28 IRM-48 Reader 910.00371.0001 8 PRODUCT CERTIFICATIONS 8.1 COMPLIANCE UL / cUL 61010-1 Registered Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1 IEC61000-6-5 Level 4 substation EMC/EMI per IEC61000-4-x below IEC 61000-4-2 ESD, ±8kV contact & ±15kV air discharge IEC 61000-4-3 RFI, 10V/m IEC 61000-4-4 EFT, ±4kV (power, humidity, and RS485) IEC 61000-4-5 Surge, ±2kV line-line, ±4kV line-PE, Criteria B IEC 61000-4-6 CRFI, 10Vrms (power, humidity, and RS485) IEC 61000-4-8 Magnetic immunity, 100V/m, 50 & 60Hz, three axes IEC 61000-4-9 Pulse magnetic field immunity test, 300A/m IEC 61000-4-10 Damped oscillatory magnetic field immunity, 30A/m IEC 61000-4-11 Voltage dips and interrupts, DC power IEC 61000-4-12 Ring wave immunity 5kV common mode, 1kV differential (power & signal) IEC 61000-4-16 Conducted frequency immunity 30V cont. and 300V/1s diff., common mode to earth (power) 30V cont. and 300V/1s, common mode to earth (signal) IEC 61000-4-17 Ripple on DC supply IEC 60255-5 Dielectric strength, 500Vrms per IEC61010-1 for 24Vdc equipment IEC 60255-5 Impulse voltage, 806V per IEC61010-1 for 24Vdc equipment EN 300 220 Conducted spurious and EMI spurious (restricted frequency ranges) EN 55011 Conducted Spurious, Class A

IntelliSAW IRM-48 Reader

Installation Manual Page 26 of 28 IRM-48 Reader 910.00371.0001 8.2 WIRELESS CERTIFICATIONS 8.2.1 Telecommunication Compliance All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. IntelliSAW is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage. However, certification is dependent on the class of asset into which the equipment is installed. 8.2.2 Approved Antennas The Reader RF module has been approved to operate with the antenna types listed below with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. IntelliSAW Part # Type Gain IA-MM-5-y Monopole (5 cm mast) -1 dBi IA-MM-9-y Monopole (9 cm mast) +1 dBi IA-MM-17-y Monopole (17 cm mast) +3.2 dBi IA-MM-TPD-y Patch inverted F (PIFA) +3.5 dBi IA-MM-TMP-y Patch inverted F (PIFA) +3.5 dBi Part Number (“y”) indicates cable length and is offered in 3, 5, or 7 meters. 8.2.3 Federal Communications Commission (FCC) This product contains FCCID: 2AEAE-ISAW-RF-H0215 The design of the IRM-48 complies with U.S. Federal Communications Commission (FCC) guidelines respecting safety levels of radio frequency (RF) exposure for fixed location devices. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules when the unit is professional installed in metal enclosures described in the IEEE standard C37.20. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

IntelliSAW IRM-48 Reader

Installation Manual Page 27 of 28 IRM-48 Reader 910.00371.0001 8.2.3.1 Installation Requirements The IntelliSAW IRM-48 and approved antennas can be professionally installed in the following installation environments: 1. Metal enclosures described in the IEEE/ANSI Std C37.20, or UL and NEMA specifications derived from Std C37.20, as indicated in KDB 550099. a. The Reader is not required to be in such an enclosure since the antenna is wired away from the host. b. The Reader firmware shall be configured for ANSI 2. Open air operation a. The antenna and reader can operate outside of the metal enclosures when the Reader firmware is configured for Open Air operation. Changes or modification to the equipment not expressly approved by IntelliSAW could void the user's authority to operate the equipment. 8.2.4 Industry Canada (IC) This product contains device certified under IC: 11526A-ISAWRFH0215 This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following conditions: • This device may not cause harmful interference. • This device must accept any interference received, including interference that may cause undesired operation. Changes or modification to the equipment not expressly approved by IntelliSAW could void the user's authority to operate the equipment Ce produit contient un appareil certifié en vertu IC: 11526A - ISAWRFH0215 Cet appareil se mets en conformité avec les normes CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux conditions suivantes: • L’appareil ne produit pas de brouillage malfaisant. • L’appareil doit accepter tout brouillage radioélectrique reçu, y compris le brouillage qui pourrait provoquer le fonctionnement non désiré. Les changements ou les modifications apportés à l'équipement qui n'est pas expressément approuvé par IntelliSAW pourraient annuler l'autorité de l'utilisateur à utiliser cet équipement.

IntelliSAW IRM-48 Reader

Installation Manual Page 28 of 28 IRM-48 Reader 910.00371.0001 CONTACT Head Office: IntelliSAW – ALTANOVA GROUP Rosemount Measurement 100 Burtt Rd. Andover, MA 01810 [email protected] +1-978-409-1534 Regional Office: IntelliSAW LATAM IntelliSAW China Regional Distributors: Visit www.altanova-group.com for the latest distribution locations.