9329-66071-00 REV A 09/19

S6L Module Installation Stage 64 Controller Assembly Replacement This document shows how to replace the Controller assembly in Avid® VENUE Stage 64 I/O units. After collecting the required items, listed below, proceed to Prepare the I/O Rack Unit. Required Items This procedure requires the following items: • #1 Phillips screwdriver (6-inch or longer) • A clean, padded work surface • Anti-static wrist strap (not included). Make sure you are electrically grounded and discharge static before working • Recommended: A known-good XLR cable to perform an audio loopback test Prepare the I/O Rack Unit Do the following to prepare your Stage 64: 1 Shut down your VENUE system and power down your Stage 64. 2 Disconnect all cables from your Stage 64. 3 Remove the back panel by loosening the eight captive thumbscrews completely, using a #2 Phillips screwdriver if necessary, and set the panel aside. Figure 1. Stage 64 back panel captive thumbscrews

Remove the Controller Assembly

To remove the Stage 64 Controller assembly: 1 Loosen the four captive thumbscrews that secure the Controller to the front of the chassis. 2 Inside the back of the unit, loosen the captive thumbscrew that secures the Controller to the chassis. 3 Starting at the far right and working to your left, disconnect all ribbon cables from each I/O card. Figure 2. Stage 64 Controller front panel captive thumbscrews Figure 3. Controller captive screw Figure 4. Ribbon cables disconnected from all I/O cards

4 Disconnect the 2x PSU cables and 1x signal cable from the back of the controller.

5 Using one hand to guide the I/O ribbon cables so they don’t get caught on the chassis frame, pull the Controller out through the front of the Stage 64. 6 Proceed to Install the New Stage 64 Controller. Figure 5. Controller PSU cable clips (shown at left) and disconnecting the signal cable (shown at right) Figure 6. Pulling the Controller assembly out of the Stage 64

Install the New Stage 64 Controller

To install the new Stage 64 Controller Assembly: 1 Hold the new Controller assembly in one hand while you carefully feed the ribbon cables into the Controller slot in the Stage 64. 2 Gently push the Controller into the slot and, reaching in from the back of the Stage 64, continue guiding the ribbon cables through ahead the slot. 3 From the back of the unit, make sure all the ribbon cables are clear of the slot and then gently push the Controller the rest of the way in. Make sure the alignment pin on the back end of the Controller assembly is lined up with, and passes through, its hole in the Stage 64 chassis. 4 Tighten the captive screw to secure the back of the Controller assembly to the Stage 64 chassis. 5 Reconnect all ribbon cables from the Controller to I/O cards, working left-to-right (shortest to longest). Make sure the tabs on the connectors click into their locked position. 6 Reconnect the 1x signal and 2x PSU cables. Make sure the cables are fully seated. 7 Making sure to orient it correctly, reinstall the back panel and tighten its eight captive thumbscrews. 8 At the front of the Stage 64, tighten the 4 captive screws on the front of the Controller assembly to secure it to the Stage 64 chassis. 9 Re-install the back cover of the Stage 64 and tighten the 8 captive screws that secure it to the chassis. 10 Proceed to Confirming Installation. Make sure the ribbon cables do not get bent or pinched, and be especially careful to prevent them from coming into contact with com- ponents on Output cards installed in the Stage 64! Figure 7. Controller assembly alignment pin correctly positioned

To confirm installation:

1 Connect the power cables to the Stage unit and to a power source. 2 Connect the Stage unit to the rest of your S6L system using Ethernet or fiber. 3 Power on your S6L system (engine, control surface, then Stage unit). 4 Enable Config mode. 5 In the VENUE software screen, go to the Options > Devices page. 6 In the AVAILABLE DEVICES column, select the Stage 64 device so it is highlighted. 7 Click CONNECT. 8 Click to select a flashing Stage slot and assign the selected I/O unit to that slot. 9 Click to select the Stage 64 in CONNECTED DEVICES. 10 In the INFORMATION pane, select the SETTINGS tab and make sure all I/O cards are shown. For example, the following image shows a Stage 64 with 6x SRI analog input cards and 1x SRO analog output cards installed. Note how only 5 of the input cards are listed. 11 If any installed card is not listed, shut down your system and Stage 64, remove the back cover and check to make sure the ribbon cable connection to each I/O card. Stage 64 selected in CONNECTED DEVICES