Flowserve IJ Installation Operation & Maintenance
File Specifications
| Brand: | Flowserve |
| Category: | Water Pump |
| Model: | IJ (Installation Operation & Maintenance), prOTllSialVxY |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 128 pages |
Download PDF
Download Flowserve IJ Manual (128 pages)Read Online:
Read the Flowserve IJ Installation Operation & Maintenance online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
IJ PUMP OPERATION AND MAINTENANCE MANUAL
4-9 BO2660-01 manufacturer's data in APPENDIX). If differential pressure of lube oil is above that specified by lube oil console manufacturer, manually route lube oil through clean filter in accordance with its manufacturer's instructions in APPENDIX. Otherwise lube oil passage through filter is nominal. 13. Observe lube oil reservoir level glass (LG); level of lube oil should appear between minimum and maximum marks on glass; if there are no marks; lube oil level should appear higher than 1/2 length of glass but not higher than 2/3 its length. To reple ...
IJ PUMP OPERATION AND MAINTENANCE MANUAL
2-7 BO2660-01 2.2.1.4 Long-Term Indoor Storage Factory preservative measures will protect the pump for long-term (greater than 6 months) storage with the following precautions taken at the site: 1. At the beginning of the storage period: a. Fill the bearing housings of pumps equipped with anti-friction bearings with vapor-phase inhibiting oil to the level of the baffles. b. Place 2 lbs (1 kg) of vapor-phase inhibiting crystals in an open canister near the center of the pump unit, a 1 lb (0.5 kg) cloth bag in each nozzle that is securely fastened to the ...
IJ PUMP OPERATION AND MAINTENANCE MANUAL
BO2660-01 3-4 4. precision machinist level or equivalent tool; 5. optical alignment equipment such as an alignment laser or jig transit that is capable of measuring to 0.001 in (0.02 mm); 6. dial indicator; 7. indicator bracket. 3.2.2 ONE BASEPLATE FOR ENTIRE TRAIN OF UNITS Where your baseplate is designed with two or more sets of mounting pads which accommodate the entire train of units (for example, pump, driver, and fluid drive) the manufacturing process for the baseplate assures alignment of every set of mounting pads; thus, you need only level ...
IJ PUMP OPERATION AND MAINTENANCE MANUAL
3-9 BO2660-01 ALIGNMENT SCHEDULE 1. First, verify that turbine is correctly aligned with plant benchmark and fixed in its permanent position. 2. Next, set up common centerline by aligning centerline of high-speed pump soleplates with centerline of turbine shaft. 3. Then align centerline of low-speed pump baseplate with common centerline. 4. Finally, align centerline of any other baseplate (or soleplates) which might be in train with common centerline. Figure 3-8 Baseplates and Soleplates in Train ...
IJ PUMP OPERATION AND MAINTENANCE MANUAL
6-9 BO2660-01 8. Disassemble thrust bearing (54) as follows: a. Remove thrust bearing shoes from top half of base rings. Then remove top half of base rings with leveling plates attached. b. Rotate bottom half of base rings to top. Remove shoes and lift off bottom halves of base rings with leveling plates attached. NOTE The CCW rotating shaft has right-hand threads on the coupling end and left-hand threads on the outboard end. Threads on the CW rotating shaft are opposite of this. c. Remove thrust collar nut (171) from the shaft. NOTE If your pump is equ ...
IJ PUMP OPERATION AND MAINTENANCE MANUAL
BO2660-01 1-2 1.1.1.4 Impellers Impellers are keyed to the shaft with one or two keys and have an interference fit with the shaft. Because of hydraulic requirements for efficiency, the pattern of the pump suction impeller usually differs from the radial impellers at the other stages. And, depending on the requirements of design, a pump may incorporate a double-suction impeller. Normally, the pump discharge impeller has the same pattern as the radial impellers of the intermediate stages. The impeller hubs and skirts are surfaced-hardened. 1.1.1.5 Bearing ...
Flowserve IJ user guide recommended for: PHL Series, 6LR-18A, Durco Mark 3, PH6, Centrifugal Pump M-TN.
⚠️ Download Safety
The Water Pump Installation operation & maintenance (128 pages) is completely safe to download (last scan date: 20/05/2026).
Related PDF Instructions for Flowserve IJ:
-
Flowserve Edward 602Y Control Unit Maintenance manual
Edward 602Y51 -
Flowserve Limitorque L120 Series Controller User instructions
Limitorque L120 Series36 -
Flowserve ROTADISK RD Controller User instructions
ROTADISK RD80 -
Flowserve McCANNA Control Unit User instructions
McCANNA13 -
Flowserve NAF ProCap Control Unit User instruction
NAF ProCap79 -
Flowserve ColdFlow 341000 Control Unit User instructions
ColdFlow 34100020
Water Pump Equipment: Frequently Requested
-
aermotor FHSN-100 Water Pump
29.05.2026Complete device guide for the aermotor FHSN-100 Water Pump. This guide presents error codes, assembly reference, service instructions, basic operation.FHSN-100, 36 -
Milton Roy Hartell KT3 Water Pump
28.04.2026Product operation manual for the Milton Roy Hartell KT3 Water Pump. The manual guides users through product handling, basic operation, detailing setup.Hartell KT3, 3 -
U.S.SAWS BP 1520 Water Pump
18.06.2026Manual for safe operation of the U.S.SAWS BP 1520 Water Pump. It covers control functions, system parameters, device safety checks.BP 1520, 8 -
Knauer Azura P 6.1L Laboratory Equipment
07.07.2026User support guide for the Knauer Azura P 6.1L Laboratory Equipment. The guide covers usage and troubleshooting guides, cleaning instructions, product safety, control functions.Azura P 6.1L, 69 -
ubbink BioPressure II 3000 Water Filtration Systems
31.05.2026Step-by-step guide for the ubbink BioPressure II 3000 Water Filtration Systems. The document provides guidance on safety and supported accessories, safety guidelines, wiring setup.BioPressure II 3000, 55 -
Jung Pumpen UAK 45/2 M /0 Water Pump
20.06.2026Owner’s manual for the Jung Pumpen UAK 45/2 M /0 Water Pump. The documentation guides users through setup and installation procedures, setup guidelines, wiring setup.UAK 45/2 M /0, 47
Have some Questions about Flowserve IJ Device?
Get valuable and actionable advices from other Flowserve IJ device users. Describe your problem or question, regarding the using of IJ, in as much detail as possible, and other users will be able to answer you.