Product specifications are subject to change without notice • Des changements peuvent être apportés au produit sans préavis.

GENERAL INSTRUCTIONS • Read this manual carefully and completely before proceeding. • It is recommended that you wear safety glasses at all times during the installation. INSTALLATION OVER CERAMIC TILES • If your shower door is to be installed over ceramic tiles, the tiles should lay completely under the wall jamb. • Silicone should be used to seal the gap where the ceramic tiles meet the fixed panel. NOTICE • Caulking: no sealant is required inside the shower, unless otherwise stated. • Some models are equipped with clear sealing gaskets. CARE FOR YOUR SHOWER DOOR • Never use scouring powder pads or sharp instruments on metal pieces or glass panels. An occasional wiping down with a mild soap diluted in water is all that is needed to keep the panels and aluminum parts looking new. • We recommend wiping the glass panels with a squeegee after each use. INSTRUCTIONS GÉNÉRALES • Lire attentivement et complètement le manuel d’installation avant de procéder. • Il est recommandé de porter des lunettes de sécurité en tout temps lors de l’installation. INSTALLATION SUR LES TUILES EN CÉRAMIQUE • Si votre porte de douche doit être installée sur une bordure en céramique, le jambage doit reposer complètement sur cette dernière. • Le calfeutrage doit être appliqué sur le côté extérieur de la douche où le panneau fixe rencontre la bordure en céramique. NOTE • Calfeutrage: aucun scellant n’est nécessaire à l’intérieur de la douche • Certains modèles sont dotés de joints d’étanchéité clairs. L’ENTRETIEN DE VOTRE DOUCHE • Ne jamais utiliser de poudre ou de tampon à récurer, ni d’instrument tranchant sur les parties en métal ou en verre. De temps à autre, il suffit de nettoyer la porte avec une solution d’eau et un détergent doux pour conserver l’aspect neuf des panneaux de verre et du cadre en aluminium. • Nous recommandons de passer une raclette de douche sur les panneaux de verre après chaque utilisation. En Fr PLEASE KEEP THIS MANUAL AND PRODUCT CODE NUMBER FOR FUTURE REFERENCE AND FOR ORDERING REPLACEMENT PARTS IF NECESSARY VEUILLEZ CONSESRVER CE MANUAL ET LE CODE DE PRODUIT POUR DES RÉFÉRENCES FUTURES, ET AU BESOIN, LA COMMANDE DE PIÉCES DE RECHARGE

TOOLS REQUIRED / OUTILS REQUIS

POSSIBLE CONFIGURATIONS / CONFIGURATIONS POSSIBLES * Use a ¼" drill bit for ceramic when drilling into ceramic tiles • * Utiliser une mèche à céramique de ¼" lors du perçage des tuiles en céramique. * This configuration is illustrated in this manual.• * Cette configuration est illustrée dans ce manuel. * PENCIL CRAYON 1/4” & 1/8” DRILL BITS MÈCHE 1/4” & 1/8” TAPE MEASURE RUBAN À MESURER HACKSAW SCIE À MÉTAUX SCREWDRIVER TOURNEVIS LEVEL NIVEAU SILICONE SCELLANT PLIERS PINCE * DRILL PERCEUSE

PARTS AND HARDWARE LISTING /

LISTE DES PIÈCES ET QUINCAILLERIE 12 13 14 15 16 18 17 19 20 21 ITEM FLEURCO CODE PARTS AND HARDWARE / PIÈCES ET QUINCAILLERIE QTY 1 ELE-WJAMB-XX-79 WALL JAMB / JAMBAGE 2 2 LA-CJAMB-XX-79 CORNER JAMB / JAMBAGE DU COIN 1 3 LAP-MAGEXP-XX-79 MAGNETIC EXPANDER / EXTENSEUR MAGNÉTIQUE 1 4 DOOR PANEL ASSEMBLY / ASSEMBLAGE DU PANNEAU DE PORTE 1 5 RETURN PANEL / PANNEAU DE RETOUR 1 6 LAVBRACKET-33 WALL MOUNT BRACKET / SUPPORT MURAL 1 PJ-BRACKET-XX 7 LAVBAR-XX-70 SUPPORT BAR / BARRE DE SUPPORT 1 8 LAV-BRACKET-S-XX GLASS MOUNT BRACKET / SUPPORT DE VERRE 1 9 HANDLE / POIGNÉE 1 10 COEX-LA415-40-33 THRESHOLD GASKET / JOINT DU SEUIL 1 COEX-LA415-40 11 PLAT-THRESH-33-72 THRESHOLD / SEUIL 1 ++15405 12 WALL PLUG / CHEVILLE 6 13 PAN HEAD SCREW / VIS À TÊTE CYLINDRIQUE 6 14 FLAT HEAD SCREW / VIS À TÊTE PLATE 1 15 PAN SELF DRILLING SCREW / VIS PAN AUTO-PERÇANTE 12 16 BACK SCREW CAP / CAPUCHON COUVRE-VIS ARRIÈRE 18 17 SCREW CAP / CAPUCHON COUVRE-VIS 18 18 LA-RP-CAP-33-79 FRAME CAP / CAPUCHON DU CADRE 1 LA-RP-CAP-XX 19 ELE-WJCAP-XX WALL JAMB CAP / CAPUCHON DU JAMBAGE 2 20 LA-CJAMB-CAP-33-79 CORNER CAP / CAPUCHON DE JAMBAGE DU COIN 1 SET LA-CJAMB-CAP-XX 21 SHIM / CALE 1 LEGEND / LÉGENDE XX = FINISH/FINI (11, 25, 33) ** = LENGTH / LONGUEUR (54, 60, 79, 86 ETC) ++ = CODE / CODE (AC, ABN)

SPACERS FUNCTION / FONCTION DES ESPACEURS

IF THE WALL OPENING EXCEEDS THE MAXIMUM DIMENSION OF THE DOOR, PLEASE CALL YOUR FLEURCO DISTRIBUTOR TO PURCHASE THE SPACERS KIT, THIS WILL EXPAND THE UNIT AN ADDITIONAL 3/4” SI L’OUVERTURE DU MUR DÉPASSE LA DIMENSION MAXIMALE DE LA PORTE, S’IL VOUS PLAÎT APPELER VOTRE DISTRIBUTEUR FLEURCO POUR ACHETER LE KIT D’ESPACEURS QUI PERMETTRA D’AJUSTER LA PORTE DE 3/4” ADDITIONNEL. 1 3 2 1 5 SPACER ESPACEUR 1 TOP VIEW VUE DE DESSUS 3/8” 9mm

Return panel size corresponding to the model that was purchased /

Taille du panneau de retour correspondant au modèle acheté MODEL MODÈLE DIM A = FRONT OPENING SPACER ESPACEUR MODEL MODÈLE DIM B = SIDE OPENING SPACER SPACEUR DIM A = DIMENSION DE L’AVANT DIM B = DIMENSION DU CÔTÉ MIN MAX MAX MIN MAX MAX ELECP23__-XX-40-79 23-1/4” 23-7/8” 24 1/4” 32 29-1/4” 29 7/8 30 1/4 ELECP25__-XX-40-79 25-1/4” 25-7/8” 26 1/4” 36 33-1/4” 33 7/8 34 1/4 ELECP27__-XX-40-79 27-1/4” 27-7/8” 28 1/4” 42 39-1/4” 39 7/8 40 1/4 ELECP29__-XX-40-79 29-1/4” 29-7/8” 30 1/4” 48 45-1/4” 45 7/8 46 1/4 ELECP31__-XX-40-79 31-1/4” 31-7/8” 32 1/4” ELECP33__-XX-40-79 33-1/4” 33-7/8” 34 1/4” (DOOR) MIN MAX (DIM A) (RETURN PANEL) MIN MAX (DIM B) TOP VIEW VUE DE DESSUS THIS DOOR OPENS OUTWARDS AND INWARDS, CONFIRM THE PLUMBING LOCATION BEFORE STARTING THE INSTALLATION CETTE PORTE S’OUVRE VERS L’INTÉRIEUR ET L’EXTÉRIEUR. CONFIRMER L’EMPLACEMENT DE LA PLOMBERIE AVANT DE COMMENCER L’INSTALLATION THE INSTALLATION SHOWN IS BASED ON PLUMB FINISHED WALLS AND A LEVELLED BASE. IF THESE CONDITIONS ARE NOT MET, PLEASE ADJUST ACCORDINGLY L’INSTALLATION ILLUSTRÉE EST BASÉE SUR DES MURS FINIS D’APLOMB ET UNE BASE DE DOUCHE NIVELÉE. SI CES CONDITIONS NE SONT PAS PRÉSENTS, VEUILLEZ AJUSTER EN CONSEQUENCE THE PANELS ARE TREATED DIFFERENTLY ON EACH SIDE. LOCATE THE MICROTEK AND S.R.T LABEL THAT IS INSTALLED ON THE MICROTEK SIDE (THE INTERIOR SIDE OF THE SHOWER). REMOVE THE STICKER AT THE END OF THE INSTALLATION. LES PANNEAUX ONT UN TRAITEMENT DIFFÉRENT SUR CHAQUE CÔTÉ. LOCALISER L’ÉTIQUETTE MICROTEK ET S.R.É QUI EST INSTALLÉE SUR LE CÔTÉ DU MICROTEK (LA FACE INTÉRIEURE DE LA DOUCHE). RETIRER L’ÉTIQUETTE À LA FIN DE L’INSTALLATION. DIMENTIONS SPECIFICATIONS INCLUDING THE SPACERS / SPÉCIFICATIONS DES DIMENTIONS Y COMPRIS LES ESPACEURS DETECTING THE S.R.T SIDE ON THE GLASS / DÉTECTER LE CÔTÉ S.R.É SUR LE VERRE

MARK THE CENTER LINES / MARQUER LES LIGNES DU CENTRE

PLACE THE CENTER OF THE WALL JAMBS ON THE CENTER LINES / PLACER LE CENTRE DES JAMBAGES SUR LES LIGNES DU CENTRE / ” / ” CENTER CENTRE TOP VIEW VUE DE DESSUS 1 (DIM A) (DIM B) INTERIOR SHOWER SIDE INTÉRIEUR DE LA DOUCHE

DE LA DOUCHE

THE SIDE HOLES OF THE WALL JAMBS MUST BE PLACED FACING TO THE INTERIOR SIDE OF THE SHOWER LES TROUS LATÉRAUX DES JAMBAGES DOÎVENT ÊTRES INSTALLÉS VERS L’INTÉRIEUR DE LA DOUCHE A C B 12 3 4 LEVEL AND MARK THE DRILLING LOCATIONS / NIVELER ET MARQUER LES POINTS DE PERÇAGE DRILL, SILICONE AND INSERT THE WALL PLUGS / PERCER, SILICONER ET INSÉRER LES CHEVILLES

IF SPACERS ARE NEEDED, INSTALL THEM ON THE WALL JAMBS PRIOR TO INSTALLING THE WALL JAMBS ON THE WALL

SI DES ESPACEURS SONT NÉCESSAIRES, LES INSTALLER DANS LES JAMBAGES AVANT D’INSTALLER LES JAMBAGES SUR LES MURS INTERIOR SHOWER SIDE INTÉRIEUR DE LA DOUCHE INTERIOR SHOWER SIDE INTÉRIEUR DE LA DOUCHE 13 INTERIOR SHOWER SIDE INTERIOR SHOWER SIDE SPACERS ARE OPTIONAL AND NOT SHOWN IN THE FOLLOWING STEPS OF THE MANUAL. SEE PAGE 6 LES ESPACEURS SONT FACULTATIFS ET NE SERONT PAS PRÉSENTS DANS LES ÉTAPES QUI SUIVENT. VOIR PAGE 6 INSTALL THE WALL JAMBS / INSTALLER LES JAMBAGES INSTALL THE SPACERS ON THE WALL JAMBS / INSTALLER LES ESPACEURS DANS LES JAMBAGES 5 4A

VUE DE DESSUS

COVER THE TEETH OF THE PLIERS TO AVOID SCRATCHING THE METAL COUVRIR LES DENTS DE LA PINCE POUR NE PAS RAYER LE MÉTAL THE LABEL INDICATES THE INTERIOR AND EXTERIOR OF THE SHOWER L’ÉTIQUETTE INDIQUE L’INTÉRIEUR ET L’EXTÉRIEUR DE LA DOUCHE 2 CENTER CENTRE TOP VIEW VUE DE DESSUS COVER THE TEETH OF THE PLIERS TO AVOID SCRATCHING THE METAL COUVRIR LES DENTS DE LA PINCE POUR NE PAS RAYER LE MÉTAL PLACE THE WIDER SIDE OF THE CORNER EXTRUSION ON THE RETURN PANEL PLACER LE CÔTÉ LE PLUS GRAND DU JAMBAGE DE COIN VERS LE PANNEAU DE RETOUR INSERT THE RETURN PANEL / INSÉRER LE PANNEAU DE RETOUR PLACE THE CORNER JAMB / PLACER LE JAMBAGE DU COIN 7 6

FINISHED WALL TO RETURN PANEL OUTER EDGE

MUR FINI AU BORD EXTÉRIEUR DU PANNEAU DU RETOUR BAR LENGTH = SUBSTRACT 5/8” FROM THE MEASUREMENT OF THE FINISHED WALL TO RETURN PANEL EDGE LONGUEUR DE LA BARRE = SOUSTRAIRE 5/8” DE LA MESURE DU MUR FINI AU BORD DU PANNEAU DU RETOUR FORMULA / FORMULE 7 MEASURE AND CUT THE SUPPORT BAR / MESURER ET COUPER LA BARRE DE SUPPORT 9 8 ADJUST THE RETURN PANEL / AJUSTER LE PANNEAU DE RETOUR

ASSEMBLE THE SUPPORT BAR AS ILLUSTRATED /

ASSEMBLER LA BARRE DE SUPPORT TELLE QU’ILLUSTRÉE 11 10 PLACE DE SUPPORT BAR ONTO THE RETURN PANEL / PLACER LA BARRE DE SUPPORT SUR LE PANNEAU DE RETOUR

MARK THE SUPPORT BRACKET POSITION / MARQUER LA POSITION DU SUPPORT MURAL

REMOVE THE SUPPORT BAR / ENLEVER LA BARRE DE SUPPORT 13 12

DE LA DOUCHE

INTERIOR SHOWER SIDE INTÉRIEUR DE LA DOUCHE E 6a 14 D C B 12 UNFASTEN SET SCREW TO SEPARATE PARTS, INSTALL THE SMALL WALL MOUNT PLATE ONTO THE WALL DÉVISSER LA VIS À DOUILLE POUR SÉPARER LES PIÈCES ET FIXER LA PLAQUE DU SUPPORT MURAL A USE A 1/4” DRILL BIT WHEN DRILLING INTO CERAMIC TILES UTILISER UNE MÉCHE DE 1/4” POUR PERCER DES TUILES EN CÉRAMIQUE PLACE THE WALL MOUNT ON THE PREVIOUS MARK AND MARK THE HOLE LOCATION / PLACER LE SUPPORT MURAL SUR LA MARQUE ET MARQUER LA POSITION DU TROU SECURE THE BRACKET / SÉCURISER LE SUPPORT 15 14

DE LA DOUCHE

CONFIG A: PAGE 16 CONFIG B: PAGE 17 CHOOSE A CONFIGURATION / CHOISIR UNE CONFIGURATION 17 16 INSTALL THE SUPPORT BAR / INSTALLER LA BARRE DE SUPPORT

VUE DE DESSUS

CONFIG A PLACE THE MAGNETIC EXPANDER / PLACER L’EXTENSEUR MAGNÉTIQUE PLACE THE SHIM ON THE BASE AND INSERT THE DOOR / PLACER LA CALE SUR LA BASE ET INSÉRER LA PORTE 19A 18A

PLACE THE MAGNETIC EXPANDER / PLACER L’EXTENSEUR MAGNÉTIQUE

18B PLACE THE SHIM ON THE BASE AND INSERT THE DOOR / PLACER LA CALE SUR LA BASE ET INSÉRER LA PORTE 19B

DE LA DOUCHE

16 15 INTERIOR SHOWER SIDE INTÉRIEUR DE LA DOUCHE 15 16 17 16 15 17 MAKE SURE THERE IS NO GAR BETWEEN THEDOOR AND THE MAGNETIC EXPANDER ONCES INSTALLED VÉRIFIER QU’IL N’Y AIT PAS D’ESPACE ENTRE LA PORTE ET L’EXTENSEUR MAGNÉTIQUE APRÈS L’INSTALLATION SECURE THE DOOR AND RETURN PANEL / SÉCURISER LA PORTE ET LE PANNEAU DE RETOUR 21 ADJUST THE DOOR AND RETURN PANEL / AJUSTER LA PORTE ET LE PANNEAU DE RETOUR 20

DE LA DOUCHE

PLACE THE BUMPERS ON THE HANDLE PLACER LES BUTOIRS SUR LA POIGNÉE 11 10 1/8” OFFSET OUTWARD FROM THE FRAME DÉCALER DE 1/8” DU CADRE VERS L’EXTÉRIEUR INSTALL THE DOOR HANDLE / INSTALLER LA POIGNÉE 22 MARK THE POSITION OF THE THRESHOLD AND GASKET AND IF NEEDED, MEASURE AND CUT / MARQUER LA POSITION DU SEUIL ET DU JOINT ET SI NÉCESSAIRE, MESURER ET COUPER 23

VUE DE CÔTÉ

B INTERIOR SHOWER SIDE INTÉRIEUR DE LA DOUCHE CUT THE WALL JAMB CAP ACCORDING TO THE DOOR’S CONFIGURATION. IF SPACERS WERE REQUIRED, CUT THE CAPS BASED ON THE NUMBER OF SPACERS USED IN THE INSTALLATION. IF NO SPACERS WERE REQUIRED, CUT THE CAP TO THE MINIMUM. COUPER LE CAPUCHON DU JAMBAGE SELON LA CONFIGURATION DE LA PORTE. SI DES ESPACEURS SONT NÉCESSAIRES, COUPER LE CAPUCHON EN FONCTION DU NOMBRE D’ESPACEURS INSTALLÉS. S’IL N’Y A PAS D’ESPACEURS, COUPER LE CAPUCHON AU MINIMUM. TOP VIEW VUE DE DESSUS 19 INSTALL THE THRESHOLD AS SHOWN / INSTALLER LE SEUIL TEL QU’ILLUSTRÉ 24 CUT THE WALL JAMB CAPS / COUPER LES CAPUCHONS DES JAMBAGES 25

PLACE THE WIDER INSERTS TOWARD THE WALL

AND PUSH DOWN PLACER LES EMBOUTS LES PLUS LARGES VERS LE MUR ET POUSSER VERS LE BAS CONFIG B WALL WALL 19 18 20 19 PLACE THE WIDER INSERTS TOWARD THE WALL AND PUSH DOWN PLACER LES EMBOUTS LES PLUS LARGES VERS LE MUR ET POUSSER VERS LE BAS INSTALL THE FRAME CAPS, WALL JAMB AND CORNER CAPS / INSTALLER LES CAPUCHONS DU CADRE, DU JAMBAGE ET DU COIN 26A INSTALL THE FRAME CAPS, WALL JAMB AND CORNER CAPS / INSTALLER LES CAPUCHONS DU CADRE, DU JAMBAGE ET DU COIN 27B