FR Family, MB91460 Emulation System
Doc. No. 002-05146 Rev. *A
Cypress Semiconductor
198 Champion Court
San Jose, CA 95134-1709
http://www.cypress.com
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
2
Copyrights
© Cypress Semiconductor Corporation, 2005-2016. The information contained herein is subject to change without notice.
Cypress Semiconductor Corporation assumes no responsibility for the use of any circuitry other than circuitry embodied in a
Cypress product. Nor does it convey or imply any license under patent or other rights. Cypress products are not warranted nor
intended to be used for medical, life support, life saving, critical control or safety applications, unless pursuant to an express
written agreement with Cypress. Furthermore, Cypress does not authorize its products for use as critical components in life-
support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The
inclusion of Cypress products in life-support systems application implies that the manufacturer assumes all risk of such use
and in doing so indemnifies Cypress against all charges.
Trademarks
All other trademarks or registered trademarks referenced herein are property of the respective corporations.
Source Code
Any Source Code (software and/or firmware) is owned by Cypress Semiconductor Corporation (Cypress) and is protected by
and subject to worldwide patent protection (United States and foreign), United States copyright laws and international treaty
provisions. Cypress hereby grants to licensee a personal, non-exclusive, non-transferable license to copy, use, modify, create
derivative works of, and compile the Cypress Source Code and derivative works for the sole purpose of creating custom
software and or firmware in support of licensee product to be used only in conjunction with a Cypress integrated circuit as
specified in the applicable agreement. Any reproduction, modification, translation, compilation, or representation of this Source
Code except as specified above is prohibited without the express written permission of Cypress.
Disclaimer
CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS MATERIAL,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. Cypress reserves the right to make changes without further notice to the materials described
herein. Cypress does not assume any liability arising out of the application or use of any product or circuit described herein.
Cypress does not authorize its products for use as critical components in life-support systems where a malfunction or failure
may reasonably be expected to result in significant injury to the user. The inclusion of Cypress‟ product in a life-support
systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress against all
charges.
Use may be limited by and subject to the applicable Cypress software license agreement.
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
3
Contents
1.
Introduction .................................................................................................................................................................... 5
2.
Hardware Requirements ............................................................................................................................................... 6
3.
Software Installation ...................................................................................................................................................... 7
3.1
Softune Workbench ............................................................................................................................................... 7
4.
Installation of the Emulation System ........................................................................................................................... 8
4.1
Providing a Clock Source ...................................................................................................................................... 8
4.2
Checking the Jumpers ........................................................................................................................................... 8
4.3
Connecting the Emulation System ......................................................................................................................... 9
4.3.1
Cabling the Emulator MB2198-01 ............................................................................................................. 9
4.3.2
Mounting the Evaluation MCU ................................................................................................................ 10
4.3.3
Connecting and Cabling the Adapter Board to the Evaluation Board ..................................................... 10
4.4
Power up the Emulation System .......................................................................................................................... 13
5.
Jumpers and Switches ................................................................................................................................................ 14
5.1
Jumpers of the MB91V460 Adapter Board (MB2198-300) .................................................................................. 14
5.1.1
V-Chip Options ....................................................................................................................................... 14
5.1.2
Emulator Interface .................................................................................................................................. 15
5.1.3
External Emulation Memory .................................................................................................................... 16
5.1.4
Clock Control .......................................................................................................................................... 17
5.1.5
Power Settings ........................................................................................................................................ 18
5.1.6
Signal Routing ........................................................................................................................................ 18
5.1.7
Default Jumper Settings .......................................................................................................................... 19
5.2
Jumpers of the evaluation board SK-91460-MAIN V1.2 ...................................................................................... 20
5.2.1
Analogue Power Supply Voltage ............................................................................................................ 20
5.2.2
Default Jumper Settings .......................................................................................................................... 21
5.3
Default Jumper Settings of the evaluation board SK-91F467D-208PFV ............................................................. 22
5.4
Default Jumpers Settings of the probe cable PB-91467D-208PFV ..................................................................... 23
5.5
Default Jumpers Settings of the probe cable PB-91467D-LS-208PFV ................................................................ 24
6.
Softune Workbench Getting Started .......................................................................................................................... 25
6.1
Copying the “template” directory .......................................................................................................................... 25
6.2
Adjusting the project files ..................................................................................................................................... 25
6.3
Opening the Softune Workbench ......................................................................................................................... 26
6.4
Entering the code................................................................................................................................................. 28
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
4
6.5
Compiling the Project ........................................................................................................................................... 28
6.6
Enter Debugging Mode ........................................................................................................................................ 29
6.6.1
Executing the Program ........................................................................................................................... 30
6.7
Ending the Debugging ......................................................................................................................................... 30
6.8
Last steps ............................................................................................................................................................ 30
7.
Setup / Change Connection PC – Emulation System ............................................................................................... 31
7.1
Setup Serial Connection ...................................................................................................................................... 31
7.1.1
Overview ................................................................................................................................................. 31
7.1.2
Settings ................................................................................................................................................... 31
7.2
Setup USB ........................................................................................................................................................... 31
7.2.1
Overview ................................................................................................................................................. 31
7.2.2
Updating the USB-Drivers ....................................................................................................................... 31
7.3
Setup LAN ........................................................................................................................................................... 34
7.3.1
Overview ................................................................................................................................................. 34
7.3.2
Configuring the LAN Adapter .................................................................................................................. 34
7.3.3
Configuring Operating System “WindowsTM”........................................................................................... 35
7.3.4
Checking the network-connection ........................................................................................................... 38
7.3.5
Troubleshooting ...................................................................................................................................... 38
7.3.6
Softune Workbench ................................................................................................................................ 40
Revision History ................................................................................................................................................................... 41
Document Revision History ........................................................................................................................................... 41
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
5
1. Introduction
The chapter gives short overview of this guide
This user guide describes the first steps how to use the MB91460 emulation system. It describes also the
software and hardware installation procedure.
Further information can be found in the following manuals:
„Softune Workbench Installation Manual for V6‟ for information about the installation procedure of the
software
„MB2198-01 Hardware Manual‟ for information about the emulator
„SK-91460-MAIN V1.2 User Guide‟ for information about the evaluation board SK-91460-MAIN and its
jumpers and options.
„SK-91F467D-208PFV V1.1 User Guide‟ for information about the evaluation board SK-91F467D-208PFV
and its jumpers and options.
„PB-91467D-208PFV User Guide‟ for information about the probe cable PB-91467D-208PFV and its jumpers
and options.
The MB91460 emulation system allows the designer immediately to start with the software development before
his own final target system is available.
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
6
2. Hardware Requirements
The chapter lists the required hardware for the MB91460 emulation system.
The MB91460 emulator system consists of
The emulator MB2198-01 incl. 16 V DC power supply
The DSU-FR cable MB2198-10
The MB91V460 adapter board (MB2198-300) incl. 16 V DC power supply
And an evaluation board, e.g.
The evaluation board SK-91460-MAIN V1.2 incl. 9 V DC power supply
Or
The evaluation board SK-91F467-208PFV V1.1 incl. 9 V DC power supply and
The probe cable PB-91467-208PFV or the probe cable PB-91467-LS-208PFV
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
7
3. Software Installation
This chapter describes the software installation procedure
This installation procedure is valid for Windows XP/2000/NT 4.0. For other operating systems and for further
details, please refer to the Softune Workbench installation manual for V6 and to the hardware manual of the
Emulator MB2198-01
3.1
Softune Workbench
Please install the Softune Propack 911s FRSTAPACK600007FME02
Execute FRSTAPACK600007FME02 and follow installation process.
This file presents the styles that are available in a chapter file for a Reference Design Guide. Styles are located
in the Styles and Formatting bar.
(Leave blank Body paragraph marker here to add space between opening sentences and main content of
chapter.)
Rule 1: To install the software under Windows XP/2000/NT 4.0, the user requires administration authority.
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
8
4. Installation of the Emulation System
This chapter describes, what should be considered and checked before power-up the emulation system. Also the
start-up procedure of the emulation system is described.
In order to properly install the emulation system, please follow the following steps.
4.1
Providing a Clock Source
The adapter board can be equipped with two clocks, a main and a sub clock. The following figure depicts who to
install the crystal and the capacities for the main clock in connector SC30. The same applies analogously for the
sub clock in connector SC31.
Figure 4-1. Installing the crystal for the main clock
The crystal for the main clock has a frequency of 4 MHz and the crystal for the sub clock has a frequency of 32
kHz. The capacity of the capacitor should be 22 pF.
4.2
Checking the Jumpers
Rule 2: To prevent damages, check all jumpers and switches before powering up the emulation system.
Jumpers of the MB91V460 adapter board (MB2198-300) and all jumpers of the evaluation board SK-91460-
MAIN V1.2 or SK-91F467D-208PFV and the probe cable PB-91467D-208PFV influencing the adapter board are
described in chapter 5.
Installation of the Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
9
4.3
Connecting the Emulation System
The following connections have to be established:
4.3.1
Cabling the Emulator MB2198-01
There are some connections necessary for the emulator MB2198-01. The following lists each step.
1.
Connect the emulator MB2198-01 (1) e.g. with the USB-Cable (2) to the USB port of the PC. (Analogously
for other connection types. Please also refer to chapter 7.
2.
Plug the DSU-FR Cable MB2198-10 (3) into the port labeled „DSU Cable‟ (4). The correct position of cable
and port is marked with arrows.
3.
Finally, connect the 16 V DC power supplies (5) to the port „DC in‟ (6) and to 230 V. Please, be aware, that
the emulator is switched off.
Figure 4-2 illustrates the necessary connections of the emulator MB2198-01.
Figure 4-2. Connections of the Emulator MB2198-01
Installation of the Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
10
4.3.2
Mounting the Evaluation MCU
1.
Press down the top of the IC socket. Take care when you press the IC socket; Hold the board against the
pressure not to bend the board.
2.
Confirm that the hook is open, and put the evaluation MCU on the socket. The index shows the A1 pin of the
evaluation MCU.
3.
Release the socket slowly and confirm that the evaluation MCU is fastening to the socket.
The following figure shows the socket of the evaluation MCU MB91V460.
Figure 4-3. Mounting the Evaluation MCU
4.3.3
Connecting and Cabling the Adapter Board to the Evaluation Board
Depending on the evaluation board, a probe cable is required or not. The following sections describe the
connection of the adapter board to the evaluation board SK-91460-Main or to the evaluation board SK-91F467D-
208PFV with the probe cable PB-91467D-208PFV or PB-91467D-LS-208PFV.
4.3.3.1
Connecting the Adapter Board to the SK-91460-MAIN
1.
Connect both boards. Be aware, that the boards are tight connected.
Figure 4-4 shows the connected boards.
Figure 4-4. Connected Adapter Board and Evaluation Board
Installation of the Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
11
After connecting both boards together it is necessary to connect the DSU-FR Cable MB2198-10 and the power
supplies.
2.
Connect the DSU-FR Cable MB2198-10 to the evaluation board.
3.
Connect the 16 V DC power supply to the port „DC in‟ and to 230 V. Please, be aware, that „SW2 Power‟ is
off.
4.
Provide the 9 V DC power supply and connect it to 230 V. The following figure shows the correct
polarization. Do not power up the evaluation board by connecting the power supply yet
Figure 4-5. The Correct Polarization of the 9 V DC Power Supply
Figure 4-6 shows the cabling of the adapter and evaluation boards.
Figure 4-6. Cabling the Adapter Board and Evaluation Board
4.3.3.2
Connecting the Adapter Board to the SK-91F467D-208PFV
1.
Connect the adapter board with the probe cable. Be aware, that the boards are tight connected.
2.
Unscrew the YQ-PACK of the SK-91F467D-208PFV and remove carefully the microcontroller from the
socket.
3.
Connect the probe cable PB-91467D-208PFV to the SK-91F467D-208PFV and tighten the screw.
The same procedure applies for the probe cable PB-91467D-LS-208PFV.
9 V
GND
Installation of the Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
12
Figure 4-7 shows the connected boards.
Figure 4-7. Connected Adapter Board, Probe Cable and Evaluation Board
After connecting the boards it is necessary to connect the DSU-FR Cable MB2198-10 and the power supplies.
4.
Connect the DSU-FR Cable MB2198-10 to the evaluation board.
5.
Connect the 16 V DC power supply to the port „DC in‟ and to 230 V. Please, be aware, that „SW2 Power‟ is
off.
6.
Provide the 9 V DC power supply and connect it to 230 V. The following figure shows the correct
polarization. Do not power up the evaluation board by connecting the power supply yet.
Figure 4-8. The Correct Polarization of the 9 V DC Power Supply
9 V
GND
Installation of the Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
13
The following figure shows the cabling of the boards.
Figure 4-9. Cabling the Adapter Board, Probe Cable and Evaluation Board
4.4
Power up the Emulation System
To avoid damages, please always follow this procedure to power up the emulation system.
1.
Switch on the main switch at the back of the emulator MB2198-01. The „Power‟ LED and the „UVCC‟ LED
have to be illuminated.
2.
Power on the MB91V460 Adapter Board (MB2198-300) „SW2 Power‟. The „Power‟ LED has to be
illuminated.
3.
Power on the evaluation board SK-91460-MAIN V1.2
Rule 3: To power down the emulation system, please follow the procedure reversely.
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
14
5. Jumpers and Switches
This chapter describes the jumpers and switches which can be modified on the MB91V460 adapter board
(MB2198-300). Also the jumpers of the evaluation board SK-91460-MAIN V1.2 influencing the adapter board are
explained. The default settings are mentioned.
5.1
Jumpers of the MB91V460 Adapter Board (MB2198-300)
5.1.1
V-Chip Options
Some options of the V-chip can be enabled or disabled.
Jumper
Setting
Description
S1
ALARM_SEL
EN – X
Old alarm comparator
X – DIS
New alarm comparator
S2
ADC_SEL
EN – X
5V ADC is enabled
X – DIS
3V ADC is enabled
S3
HWWDG_KILL
EN – X
Hardware watchdog is disabled
X – DIS
Hardware watchdog is enabled
S4
FIX_ENX
EN – X
Fixed Mode / Reset Vector is enabled
X – DIS
Fixed Mode / Reset Vector is disabled
S5
CSV_KILL
EN – X
Clock supervisor is disabled
X – DIS
Clock supervisor is enabled
S6
SRAM_SFX
EN – X
Flash Mode
X – DIS
SRAM Mode
S7
FSC_DISABLE
EN – X
Disable flash security of emulation flash
X – DIS
Enable flash security of emulation flash
Default:
S1 = X–DIS
S2 = EN–X
S3 = X-DIS
S4 = EN–X
S5 = X–DIS
S6 = X–DIS
S7 = EN–X
Note:
1.
ALARM_SEL: The 91V460 is equipped with two different alarm comparators. The devices 91F467D and
91461 are equipped with the new alarm comparator.
2.
ADC_SEL: Depending on the voltage supply the respective ADC have to be selected.
3.
HWWDG_KILL: The hardware watchdog has to be enabled also in the Softune workbench.
(Debug Mode: Setup-> Dev. Environment-> Dev. Environment-> Execution-> watchdog)
Jumpers and Switches
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
15
4.
SRAM_SFX: Depending on the connected emulation memory, the respective mode has to be selected. By
default a SRAM is connected.
5.1.2
Emulator Interface
The emulator interface can be terminated if the in-circuit-emulator (ICE) is not used.
Jumper
Setting
Description
S14
INITX
USER – INITX
INITX is controlled by the evaluation board
INITX – ICE
INITX is controlled by the emulator
S15
TRSTX
USER – TRSTX
TRSTX is controlled by the evaluation board
TRSTX – ICE
TRSTX is controlled by the emulator
S16
ICD3
PD_OFF – ICD3
Disconnect pull-down resistor to ICD3
ICD3 – PD_ON
Connect pull-down resistor to ICD3
S17
ICD2
PD_OFF – ICD2
Disconnect pull-down resistor to ICD2
ICD2 – PD_ON
Connect pull-down resistor to ICD2
S18
ICD1
PD_OFF – ICD1
Disconnect pull-down resistor to ICD1
ICD1 – PD_ON
Connect pull-down resistor to ICD1
S19
ICD0
PD_OFF – ICD0
Disconnect pull-down resistor to ICD0
ICD0 – PD_ON
Connect pull-down resistor to ICD0
S20
BREAK
PD_OFF – BREAK
Disconnect pull-down resistor to BREAK
BREAK – PD_ON
Connect pull-down resistor to BREAK
Default:
S14 = INITX–ICE
S15 = TRSTX–ICE
S20 = OFF-BREAK
S16 = OFF–ICD3
S17 = OFF–ICD2
S18 = OFF–ICD1
S19 = OFF–ICD0
Note:
1.
If the in-circuit-emulator (ICE) is used, the default settings have to be used.
Jumpers and Switches
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
16
5.1.3
External Emulation Memory
The size of the external emulation memory and the emulation memory width is selectable.
Jumper
Setting
Description
S13
D32_D16SL
D32 – X
External emulation memory is used in a 32 bit width
X – D16
External emulation memory is used in a 16 bit width
Jumper
MDENS2
MDENS1
MDENS0
Size
S10 MDENS1
S11 MDENS0
S12 MDENS2
1
1
1
8 MByte
1
1
0
4 MByte
1
0
1
2 MByte
1
0
0
1 MByte
0
1
1
512 kByte
0
1
0
Prohibited
0
0
1
Prohibited
0
0
0
0 Byte
Default:
S13 = D32-X
MDENS0 = 0
MDENS1 = 0
MDENS2 = 0
Jumpers and Switches
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
17
5.1.4
Clock Control
The source of the main and the sub clock is selectable between the adapter board and the evaluation board.
MCLKI and MCLKO of the external bus interface can be connected to the evaluation board or can be shorten on
the adapter board.
Jumper
Setting
Description
S22
EML – X0
Main clock provided from adapter board
X0 - USER
Main clock provided from evaluation board
S23
EML – X1
Main clock provided from adapter board
X1 - USER
Main clock provided from evaluation board
S24
EML – X0A
Sub clock provided from adapter board
X0A - USER
Sub clock provided from evaluation board
S25
EML – X1A
Sub clock provided from adapter board
X1A - USER
Sub clock provided from evaluation board
S30 / S31
MCLKI /
MCLKO
EVA – MCLKI
EVA – MCLKO
MCLKI and MCLKO are not connected to evaluation board. MCLKI
and MCLKO are shorten
MCLKI – USER
MCLKO – USER
MCLKI and MCLKO are connected to evaluation board. MCLKI and
MCLKO are not shorten
Default:
S22 = EML-X0
S23 = EML-X1
S24 = EML-X0A
S25 = EML-X1A
S30 = MCLKI-USER
S31 = MCLKO-USER
By default the clocks are provided from the adapter board.
By default MCLKI and MCLKO are connected to the evaluation board.
Jumpers and Switches
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
18
5.1.5
Power Settings
The voltage sources are selectable.
Jumper
Setting
Description
S26
SHDNSEL
UVCC5 – SHDNSEL
Keep watching VCC5 of evaluation board
SHDNSE – UVCC3
Keep watching VCC3 of evaluation board
S27
VCCC3SEL
3.3V – VCCC3SEL
MB91V460‟s VCC3 is supplied by evaluation board
VCCC3SEL – 3.5V
3.5V is supplied to VCC3 of MB91V460
S28
VCC5
UVCC3 – VCC5
Connect VCC3 of the adapter board to VCC3 of evaluation board
VCC5 – UVCC5
Connect VCC5 of the adapter board to VCC5 of evaluation board
S29
UVCC3H
UVCC5 – UVCC3H
VCC5H is generated from VCC5 by adding +1 V
UVCC3H – UVCC3
VCC5H is generated from VCC3 by adding +1 V
S8
C
VCC3 – C
Connect to VCC3 of MB91V460
C – VCC3C
Connect to the C terminal of the evaluation board
Default:
S26 = SHDNSEL–UVCC3
S27 = VCCC3SEL–3.5V
S28 = VCC5–UVCC5
S29 = UVCC3H–UVCC3
S8 = VCC3 – C
Note:
1.
SHDNSEL: VCC3 or VCC5 can be supervised. If the selected voltage fails, the power supply of the
evaluation chip will be cancelled.
5.1.6
Signal Routing
Some signal can be routed depending on the application of the evaluation board.
Jumper
Setting
Description
S21
P10_7
PULLDOWN –
P10_7
Pull-down resistor is connected to P10_7
P10_7 – PULLUP
Pull-up resistor is connected to P10_7
S32/S33
P224/P242
P224 – CN2_B68
P242 – CN3_A6
P22_4 is connected to CN2_B68
P24_2 is connected to CN3_A6
P224 – CN3_A6
P242 – CN2_B68
P22_4 is connected to CN3_A6
P24_2 is connected to CN2_B68
S34/S35
P225/P243
P225 – CN2_B67
P243 – CN3_A5
P22_5 is connected to CN2_B67
P24_3 is connected to CN3_A5
P225 – CN3_A5
P243 – CN2_B67
P22_5 is connected to CN3_A5
P24_3 is connected to CN2_B67
Default:
S21 = PULLDOWN – P10_7
S32 = P224 – CN2_B68
S33 = P242 – CN3_A6
S34 = P225 – CN2_B67
S35 = P243 – CN3_A5
Jumpers and Switches
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
19
5.1.7
Default Jumper Settings
In Figure 5-1 the default jumper settings of the adapter board are marked. The resistor can be removed, beside
of R71, R74 and R75.
Figure 5-1. Default Jumper Settings of the Adapter Board
Jumpers and Switches
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
20
5.2
Jumpers of the evaluation board SK-91460-MAIN V1.2
In this section only the jumpers, influencing the adapter board are explained. Please refer to the user guide of the
evaluation board SK-91460-MAIN V1.2 for the other jumpers and switches.
5.2.1
Analogue Power Supply Voltage
The power supply for the ports of the adapter board is generated by the evaluation board. The voltage is
selectable between 3.6 V and 5 V.
Jumper
Setting
Description
SL260
closed
The microcontroller interface is powered with 3,3V
open
The microcontroller interface is powered with 5V
SL262
closed
Power supply MCU_Vcc is connected
open
Power supply MCU_Vcc is disconnected
ST370
closed
3,3V is supplied to UVCC3
open
3,3V is not supplied to UVCC3
ST371
closed
3,3V is supplied to VCC3C
open
3,3V is not supplied to VCC3C
Default:
SL260 = open
SL262 = closed
ST370 = closed
ST371 = closed
By default, the I/O-ports are supplied by 5 V.
Note:
1.
The Jumper S28 of the adapter board selects UVCC3 or MCU_VCC (UVCC5) as power supply for the I/O-
port. By default this Jumper selects MCU_VCC (UVCC5).
Jumpers and Switches
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
21
5.2.2
Default Jumper Settings
In Figure 5-2 the default jumper settings are marked. For detailed information about the jumpers, please refer to
the hardware manual of the evaluation board.
Figure 5-2. Default Jumper Settings of the Evaluation Board SK-91460-MAIN
Jumpers and Switches
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
22
5.3
Default Jumper Settings of the evaluation board SK-91F467D-
208PFV
In the following figure the default jumper settings are marked. For detailed information about the jumpers, please
refer to the user guide of the evaluation board.
Figure 5-3. Default Jumper Settings of the Evaluation Board SK-91F467D-208PFV
Jumpers and Switches
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
23
5.4
Default Jumpers Settings of the probe cable PB-91467D-208PFV
In the following figure the default jumper settings are marked. For detailed information about the jumpers, please
refer to the user guide of the evaluation board.
Figure 5-4. Default Jumper Settings of the Probe Cable PB-91467D-208PFV
Jumpers and Switches
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
24
5.5
Default Jumpers Settings of the probe cable PB-91467D-LS-208PFV
In the following figure the default jumper settings are marked. For detailed information about the jumpers, please
refer to the user guide of the evaluation board.
Figure 5-5. Default Jumper Settings of the Probe Cable PB-91467D-LS-208PFV
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
25
6. Softune Workbench Getting Started
Preparing a New Project
6.1
Copying the “template” directory
If you want to create a new project it is strongly recommended to use the “template project” as a base of
operations.
The “template project” includes all basic settings for a quick and safe start. It includes the header and includes
files of the latest released version.
To start, copy the “template” directory with all its sub folders.
For example, we want to create a project, called LED. For that, rename the copy of the “template” folder to
“LED”.
Figure 6-1. Copy the Template Project
6.2
Adjusting the project files
First click into the new “LED” folder and rename the following files:
Template.prj
Led.prj
Template.wsp
Led.wsp
Now open the file “Led.prj” with your favorite text editor.
You will find an entry like this:
[DirInfo]
PRJ=C:\
Softune Workbench Getting Started
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
26
In the line “PRJ=” please edit the file path to your correct path. Of course, the “template” has to be renamed to
“led”.
Save and close the file. Attention: If you use MS Word, please be sure to save the file as a normal text file, not as
a word document!
Now open the file “Led.wsp” also with a text editor.
Do the following changes:
[PrjFile]
Count=1
FILE-0=Template.prj
FILE-0=Led.prj
ActivePrj=Template.prj
ActivePrj=Led.prj
[SubPrj-Template.prj]
[SubPrj-Led.prj]
Like in the Prj-File, you have to set your correct project folder path in the “WSP=” line:
[DirInfo]
WSP=C:\
Now save and close the file also as a normal text file.
The new project environment is now adjusted.
6.3
Opening the Softune Workbench
Now you can open the Softune Workbench. For installation of this tool please refer to the Installation Guide App.
Note.
Choose the Menu File/Open. The following pop up window will occur:
Figure 6-2. Open a Workspace
Click “OK” for “Workspace/Project file”, and then browse to the file “Led.wsp”. Open it.
Softune Workbench Getting Started
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
27
Then the following project structure will be displayed on the left side of the Softune screen.
The next level contains the ABS-File of the Project, which contains the compiled program data
The source files, their dependencies and the debugger settings follow.
For the moment the Source Files are in the point of interest.
Open the Source File of the Main Program “Main.c” by double clicking it in the window shown left.
Now a text editor window will open, which shows the contents of “Main.c”. It will look like this:
Softune Workbench Getting Started
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
28
Figure 6-3. The MAIN.C Code of the Template
The code only contains the chip specific header inclusion and in the main routine a frame for the interrupt
initialization.
6.4
Entering the code
Now the development of the application can begin, therefore the main-function is already prepared.
Interrupt definition is done in the file „vectors.c'.
6.5
Compiling the Project
Because of the usage of the “Template Project”, you now can compile this example at this moment. No other
settings have to be done.
There are two ways to build to the whole project data. Either choose Project/Build or click the button in the circle
in the illustration below:
Softune Workbench Getting Started
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
29
6.6
Enter Debugging Mode
After a successful project built you can enter the debugger mode via three different interfaces depending on your
hardware set up:
PC-COM-Port (RS232)
LAN Interface
USB Port
By double clicking on the correct connection type of the Debug dependency in the Project window (*.sup-files),
your PC will connect to the MB2198-01 Emulator and the Softune Workbench will enter the Debugging Mode.
After a successful connection, the Softune Workbench will look like this:
Figure 6-4. Debugging Mode after a successful Connection
Note: The interface has to be determined only once. Later you can choose the menu Debug/Start debug to enter
this mode.
Softune Workbench Getting Started
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
30
6.6.1
Executing the Program
Now choose Debug/Run/Go, press F5 or click the
button. Look at the Starter Kit. A “scrolling” LED has to
be flashing on the Board.
To halt the execution, choose Debug/Abort or click the
button (Note, that this button is only active in
execution mode). The emulator system now is being halted. The execution can be continued by entering the
“Go”-Mode again.
6.7
Ending the Debugging
To end the debugging just choose the menu Debug/End debug.
6.8
Last steps
To save the project data choose File/Close Workspace.
Click “Yes”. Afterwards you can close the Softune Workbench.
Note, that in the next start of the Workbench, your new LED-Project will occur in the menu list File/Recent
Workspace File. By simply clicking to “Led.wsp”, the whole project will open again.
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
31
7. Setup / Change Connection PC –
Emulation System
This chapter describes who to establish the connection between PC and emulation system.
The emulator MB2198-01 offers three possibilities to program and to debug a device, namely via
Serial connection
USB
LAN
In the template for the 91V460 all three connection types are already preconfigured, but for some device
additional settings have to be made.
7.1
Setup Serial Connection
7.1.1
Overview
The emulator MB2198-01 offers the possibility to program and debug a device via a serial connection. Even
though this is a very easy to install connection, the transmission speed is very slow.
7.1.2
Settings
The default setting for debugging via a serial connection is COM 1 and a baud rate of 115200 Baud.
7.2
Setup USB
7.2.1
Overview
The emulator MB2198-01 is provided with a USB port that can be used to program and debug a device. No
additional hardware connection is required for this purpose.
7.2.2
Updating the USB-Drivers
To operate the emulator MB2198-01 on the PC, the USB-Drivers of the PC have to be updated. The following
procedure describes the update-process.
1.
Connect the USB-Cable to the emulator MB2198-01 and to the PC. Connect the 16 V DC power supply to
the port „DC in‟ and to 230 V. Please, be aware, that the emulator is switched off. Also refer to Figure 4-2.
2.
After the PC is booted, power up the emulator. Windows will register a new hardware component and will
start the hardware wizard. Select the option „No, not this time‟ to search the drivers manually and press
„Next‟.
Setup / Change Connection PC – Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
32
Figure 7-1. Installing the USB-driver I
3.
Select the option „Install from a list or specific location (Advanced) and press „Next‟
Figure 7-2. Installing the USB-driver II
Setup / Change Connection PC – Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
33
4.
Include the subfolder „Drivers‟ of the unpacked the softune propack 911s Rev 60006, e. g.
„c:\temp\rev600006\Drivers‟ in the search. Press „Next‟ to install the drivers.
Figure 7-3. Choose the search options
5.
Finish the update procedure by pressing „Finish‟.
Figure 7-4. Close the hardware wizard
Rule 4: To install the software under Windows XP/2000/NT 4.0, the user requires administration authority.
Setup / Change Connection PC – Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
34
7.3
Setup LAN
7.3.1
Overview
The emulator MB2198-01 is provided with a local area network port that can be used to program and debug a
device over a network connection. No additional hardware connection except the LAN connection itself is
required for this purpose
Using the Cypress LAN-remote controlled debug facility,
A Cypress support engineer can easily help solving a concrete problem by debugging your application out of
a Cypress support centre.
You can control the emulator from different locations without having to move your hardware installation from
one place to another.
Program download will be more than 6 times faster than with RS232C
7.3.2
Configuring the LAN Adapter
1.
Connect emulator and PC by the serial RS232-Port (or USB-Port)
2.
Start the „LAN Address“ Program in the Softune Workbench Folder
3.
Click on Communication to define the serial RS232 Port where the emulator is connected to or use USB
connection.
4.
Read current status from the emulator
5.
Set the unique IP address given from your network manager. This is a very important point; every IP-
address within a network has to be unique.
6.
Check the Port address: must be 5001
7.
Make settings valid by “Set”, and reset the emulator when prompted
8.
Close Program “LAN Address”
Setup / Change Connection PC – Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
35
Figure 7-5. Changing the IP-Address
7.3.3
Configuring Operating System “WindowsTM”
1.
Within your WindowsTM-directory (e.g. C:\windows or C:\WINNT\system32\drivers\etc) you should find three
files:
services
hosts
lmhosts[.sam]
(Note: The files may not have a file-extension!)
2.
Make a copy off all three files, like for an example: services to sevices.old , etc.
Edit file services and add the following line:
fjicesv 5001/tcp # Cypress emulator
Setup / Change Connection PC – Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
36
Figure 7-6. Add a Service
(Note: if 5001/tcp is already contained in the file services, use an unused number beginning with 5002 or
greater, e.g. fjicesv 5002/tcp. In that case also the emulator address given by the program “LAN
address”(see above) has to be changed!
3.
When saving again the file Services be sure that your editor (e.g. notepad) will not add any extension, e.g.
.txt, to your file. To get sure, use quotation marks for the filename:
File save as: “services”
4.
The file hosts is used to make a redefinition of the complex IP-number with a simple name within your global
network. This may be important if you use a DNS-Server. Of course, you can define different names for the
same IP-Address, as shown below. Edit file hosts and add the following line:
“The unique IP address (as set by LAN-Address, see above)” “Nickname of emulator”
e.g. 141.187.6.82 Emulator
Setup / Change Connection PC – Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
37
Figure 7-7. Add a Host
When saving again the file Hosts be sure that your editor (e.g. notepad) will not add any extension, e.g. .txt, to
your file. To get sure, use quotation marks for the filename:
File save as: “hosts”
5.
The file lmhosts (or lmhosts.sam) is used to make a redefinition of the complex IP-number with a simple
name within your local network.
Of course, you can define different names for the same IP-Address, as shown below. Edit file lmhosts and
add the following line:
Setup / Change Connection PC – Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
38
Figure 7-8. : Edit the File Imhosts.asm
“The unique IP address (as set by LAN-Address, see above)” “nickname of emulator”
e.g.
141.187.6.82 fjicescv
141.187.6.82 Emulator
When saving again the file Imhosts get sure that your editor (e.g. notepad) will not add any extension, e.g. .txt, to
your file. To get sure, use quotation marks for the filename:
e.g. File save as: “lmhosts” (or lmhosts.sam)
7.3.4
Checking the network-connection
Disconnect serial RS232 (or USB) cable from Emulator and try to find the emulator:
Open DOS-Window (or open RUN (Ausführen) in the Start-Menu)
The command ping Emulator should acknowledge with some time-values, that means the network is set
up right.
The emulator with LAN-adapter is successfully integrated in the network environment and can be used by the
Softune Workbench.
7.3.5
Troubleshooting
If the command ping my_emulator will reply with a timeout-message, try to find the emulator by its IP-
address: Type command ping IP-address, e.g. ping 141.187.6.82.
If this will work, then check settings (nickname and IP-address) within Imhosts and Hosts.
If neither nickname (my_emulator) nor IP-address will work, check settings done by the program LAN-address
and check the file Services.
Also check your physical network interconnection cables. When using a HUB for 10Base-T then a standard (1:1)
network cable has to be used. If the emulator is connected directly to the PC a “crossed network cable” is
necessary.
Good answer: Emulator/LAN-adapter replies with time-values:
Setup / Change Connection PC – Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
39
Figure 7-9. Testing the IP-Connection to the Emulator I
“Failed”-answer: Emulator/LAN-adapter replies with timeout message:
Figure 7-10. Testing the IP-Connection to the Emulator II
Setup / Change Connection PC – Emulation System
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
40
7.3.6
Softune Workbench
Within the Softune Workbench the LAN interface can be used instead of a serial RS232C communication. Detail-
Host: can be the “nickname” as defined in the files hosts and lmhosts or the IP-address of the emulator, set by
the program “LAN-Address”, can be used.
Figure 7-11. Changing the IP-Address of the Host in the Softune Workbench
Nickname or
IP address
FR Family, MB91460 Emulation System, Doc. No. 002-05146 Rev. *A
41
Revision History
Document Revision History
Document Title: FR Family, MB91460 Emulation System
Document Number: 002-05146
Revision
Issue Date
Origin of
Change
Description of Change
**
05/18/2005
NOFL
V1.0; UMa :Initial Release
07/18/2005
V1.1; UMa
07/28/2005
V1.2; UMa
08/16/2005
V1.3; UMa
09/02/2005
V1.4; PHu: specify board in 4.1 Providing a Clock Source; clarify jumper
setting in 5.1.4 Clock Control
10/20/2005
V1.5; UMa: Installation procedure changed
Default jumper settings changed: HWWD is enabled (S3:EN_X)
Def. jumper settings corrected: SL260 is open, SL262 is closed
01/17/2006
V1.6; UMa: Typos corrected
04/12/2006
V1.7; Resistors on adapter board can be removed; Changed software
installation procedure; Added SK-91F467D-208PFV
09/27/2006
V1.8; UMa: Corrected typo in defaults of 5.1.2 Emulator interface. Table was
Corrected.
12/14/2007
V1.9 UMa: Corrected number of document
*A
01/19/2016
NOFL
Migrated Spansion Guide from MCU-AN-300005-E-V19 to Cypress format