Durite 0-649-35 Quick Start Manual

Text of the manual

12/24v Li-Polymer Jump Starter Pack

Part No. 0-649-35 0-649-35-LEAF www.durite.co.uk GENERAL DURITE’s innovative 12/24v Li-Ion Jump pack. Super light and compact with capability to jump start all petrol vehicles and diesel vehicles with upto 13.0L engine capacity. For 12v application this product outputs 500A Starting Current and 1000A Peak Current, for 24v application this product outputs 250A Starting Current and 500A Peak Current. WARNING! Before using this unit please read these instructions carefully. Take special care to follow the warnings and safety suggestions listed throughout this manual. Keep these instructions for future reference.

1. Check before using the product that there are more than 3 lights available on the battery

indicator (60% charge state). If there is not do not attempt to start the vehicle until the unit is fully charged. 2. Do NOT crank the engine for more than 3 seconds using the product. 3. Please wait at least 15 seconds before trying to crank the engine again if it does not start. 4. Make sure the voltage is selected before connecting to a vehicle battery 5. Do not connect a RED Clamp to the earth terminal on battery and vice versa as this will lead to short circuit. It could damage the product and further be dangerous to the user. 6. Remove the jump starter immediately on starting the vehicle. 7. Always check that the jumper clamps are connected correctly. Check the vehicle battery terminals to ensure they are not rusty/dirty. If so clean before attempting to connect and jump this vehicle. 8. If the vehicle does not start on the third attempt please do not try again as this will damage the unit and will void the warranty. 9. If the unit enters its 'protected state' please press and hold the 'test' button to reset the unit. 10. This unit has no serviceable parts inside. Please do not try to open/dissemble the unit as this could be dangerous and will void the warranty. 11. MUST NOT BE USED TO JUMP START ANY VEHICLE WITH A LITHIUM ION BATTERY INSTALLED - RISK OF DAMAGE OR INJURY! 12. Do not use the unit if it has been dropped or damaged. 13. Do not charge for more than 8 hours. Remove from charge once all status LED’s are no longer illuminated.

What is the lowest and highest voltage to be detected by the jump pack to know it is

operating a 12v system? There are some voltage ranges for 12V system : 0<3V<8.1V<12V<13.5V. 0--3V: When the car battery is in this range the Jump pack will not react . 3V-8.1V: The 12V Led light will flash, meaning the vehicle battery is weak, the jump pack will need manual operation by pressing the 12V button when the 12v system cannot be automatically recognized. 8.1V--12V: In this range the 12V system can automatically recognize the 12V battery, it will automatically begin to work and output current. 12V--13.5V: In this range the vehicle battery has enough power to start the engine, in this situation the 12V led will be on but no output will occur. What is the lowest and highest voltage to be detected by the jump pack to know it is operating a 24v system? There are some voltage ranges for 24V system : 13.5V<14.4V<16.2V<24V 13.5V--14.4V: The 12V and 24V led will flash and alternate. No output will be offered, you need to manually operate and press the 24V button to engage the jump pack. 14.4V--16.2V: 24V led will flash, no output will occur, the jump pack will need manual operation by pressing the 24V button to engage the jump pack. 16.2V--24V: 24V led will be on and the 24V system can automatically recognize the 24V battery , will begin to work immediately. 24V: In this range the vehicle battery has enough power enough to start the engine, in this situation the 24V led will be on but no output will occur.

Storage Level Indicators

Press the switch to check the battery level of Jump Starter. The indicator will flash one by one during the period of charging. Different num- bers of solid indicators show different storage level of Jump Starter. All indicators lights turn off when the charging is completed and the units battery is full. Charging the Jump Starter: 1. Plug the domestic charger into the 240v socket (or in car charger to 12v socket). 2. Connect the other end of the charger to 15V 1A input port of Jump Starter. 3. Remove from charge once LED status lights turn off or after 8 hours (max.) Jump Start Vehicle Instructions: 1. Make sure the unit has more than 3 light indictators available before attempt- ing to jump start the vehicle. 2. Connect the RED clamp to the vehicle’s battery positive(+) terminal and con- nect the BLACK clamp to the vehicle’s battery negative(-) terminal. 3. The product will automatically identify the 12v/24v voltage via its unique intelli- gent identifcation function. 4. Start the vehicle. 5. When the vehicle is started remove the jumper cables from the vehicle’s bat- tery. 6. Leave the vehicle engine running. 0-649-35-LEAF www.durite.co.uk OPERATION GUIDANCE Switch Instruction: Switch #1 (TEST) Check the batterys storage level and turns the product on. Switch #2 (12/24V) Selects required voltage. Press 12V for 12V vehicles. Press 24V for 24V vehicles.

If there is no jump start reaction please check the following:

1. Check to see that the battery clamps are connected correctly. 2. If the clamps are connected correctly but there is still no power please check the vehicle’s battery to ensure it has not failed. 3. If the above has been fulfilled then the vehicle will need to be inspected by a professional who can assess the vehicle for the further fault. PARTS LIST 1 x 24v Li-Polymer Jump Pack 1 x 230v UK Charger 1 x 12v In car charger 1 x User Manual TROUBLESHOOTING 12/24v indicators are flashing frequently - The appliance will lock itself for self protection from short circuit if it is detected. Unlock the unit by pressing and holding the on/off switch for 5 seconds. 12/24v indicators twinkle frequently when connecting to the vehicle’s battery. Check to see that the product clamps are connected to the correct terminals on the battery. 0-649-35-LEAF www.durite.co.uk