Amulet Hotkey CoreModule FX300 Quick Start Manual
Text of the manual
FX2s CoreModule™ FX300 (Single-Width Taco)
Remote Workstation solutions for Dell FX2s FC630/FC640 blade servers
Quick Start Guide
www.amulethotkey.com
QS-FX30-0001 v1.0 February 2021
For Health and safety information, refer to the sheet LS-AHKL-0001.
The Amulet Hotkey® CoreModule™ FX300 is a unique, single slot PCIe expansion
module for the Dell PowerEdge FX2 chassis. incorporating a
Each CoreModule FX300 contains one Intel® Programmable Acceleration Card
(PAC) with the Intel® Arria® 10 GX FPGA. The Aria 10 provides data centers
with both inline and lookaside acceleration, high-performance and outstanding
versatility. The FX300 delivers superior scalability, reliability and performance.
There may be different ways to configure, depending on use case. As well as
explaining the basic installation of the FX300, this guide gives setup examples of
how to use an CoreModule FX300 with an FC640 for remote access to the FGPA.
Assign two module slots to one blade (default)
Each CoreModule FX300 contains one Aria PCIe card that maps to a blade
installed in the top/bottom position in the same side at the front of the FX2s
chassis as shown in Figure 1.
Figure 1: Four blade configuration example
In Figure 1 the CoreModule FX300s in positions PCIe1 & PCIe2 at the rear left
hand side (LHS) connect with a blade in the bottom Compute 4 position on the
right hand side (RHS) at the front.
The second pair (PCIe3 & PCIe4) connect to the blade in the top Compute 2
position on the same side.
The third pair (PCIe5 & PCIe6) connect to the bottom Compute 3 position on the
front LHS.
The fourth pair (PCIe7 & PCIe8) connect to Compute 1 in the top position on the
front LHS.
Assign four module slots to one blade
If only one blade is used on half of the chassis, the space below can be empty,
contain a storage sled, or a compute sled with no PCIe expansion requirement.
In Figure 2, four CoreModule FX300s connect with a single blade in the top
Compute position. So Compute 1 connects to PCIe5, 6, 7 & 8 on the RHS (rear).
Compute 2 connects to PCIe 1, 2, 3, 4 on the LHS (rear).
Figure 2: Two blade configuration example
How to select the mapping for four module slots to one blade
! Caution:
This is only possible when all sleds or blades are powered down.
1
Login to the CMC with the IP address, username and password.
2
Select PCIe Overview from the left-hand menu and click the Setup tab.
3
Make sure the Enable PCIe Slot Reassignment box is checked. See Figure 3.
Note: This selection is automatic when a storage sled is installed in the chassis
slots Compute 3 or Compute 4, reassigning the slot below to the slot above.
Figure 3: Reconfigure the iDRAC for alternative slot reassignment
Prepare the blades in the FX2s chassis
1
For a new install, power down all the blades.
2
For an existing configuration (if applicable):
a). shut down or migrate all VMs hosted by the blades;
b). in the VMware vSphere client, locate the ESXi server in the Inventory and
put it in to Maintenance Mode;
c). power down any blades that will connect to the CoreModule FX300.
3
Remove any PCIe modules that occupy the slots where you will install the
CoreModule FX300.
Install a CoreModule FX300 module in a PCIe slot
The CoreModule FX300 module installs easily into the rear of the FX2s chassis
into one of the eight slots of the expansion bay.
Do the following steps to install each module.
! Caution:
Always use anti-static handling procedures, such as wearing a
wrist-strap, before handling the CoreModule FX300.
1
Remove all packaging and the connector protector from the module.
2
Decide which is the correct position to install the module(s).
Note: Make sure you install the CoreModule FX300 module in the correct PCIe
slot of the expansion bay for your configuration. Refer to Figure 1 and Figure 2.
FX2s CoreModule™ FX300 (Single-Width Taco) Quick Start Guide
Health and Safety (Refer to legislation sheet LS-AHKL-0001)
•
This device complies with part 15 of the FCC Rules (Class A)
•
Operating temperature range: 15° to 35° C (59° to 95° F)
•
Operating humidity range: 10% to 80% (non-condensing)
For product documentation, downloads and technical assistance, visit:
For further information on all our products, visit www.amulethotkey.com.
© 2021 Amulet Hotkey Ltd. All rights reserved.
Information in this document is subject to change. No part of this document may be reproduced through any means including (but not limited to) electronic or
mechanical, without express written permission from Amulet Hotkey Ltd. Amulet Hotkey Ltd may have patents, patent applications, trademarks or copyrights or other
intellectual property rights covering subject matter in this document. PC-over-IP, PCoIP and the PCoIP logo are registered trademarks of Teradici Corp. Amulet Hotkey
is a registered trademark of Amulet Hotkey Ltd. Other product names and company names listed within this document may be trademarks of their respective owners.
Amulet Hotkey products are designed and built in the UK.
3
Press in the release tab on the top of the module lever.
4
Pull the module lever down prior to inserting into the expansion bay.
5
Align the connectors on the rear of the CoreModule FX300 module with the
expansion connector at the rear of the FX2 chassis. See Figure 4.
6
Push the module into the expansion bay so it is almost fully installed.
7
Push the card-puller lever up until you hear a click. The module is installed.
Figure 4: Install the CoreModule FX300 module in a PCIe expansion slot.
8
Connect a QSFP connection to the front of the module if required. See
Figure 5.
Figure 5: Location for QSFP connection to the front port
A fully populated chassis looks like Figure 6.
Figure 6: A populated FX2s chassis with eight CoreModule FX300 modules
Set up the CoreModule FX300
! Caution:
Follow the requirements for proper thermal control of the FX400.
Sled
iDRAC
Minimum BIOS
Minimum requirement
FC640
iDRAC9
2.5.4
4.00.00.00 (70) firmware installed
1
Install the latest approved iDRAC on all compute sleds in the FX2s chassis.
See our support website and the Tech Note for the latest approved versions.
2
To select the configuration in Figure 1, make sure the checkbox for Enable
PCIe Slot Reassignment is deselected.
3
To select the configuration in Figure 2, make sure the checkbox for Enable
PCIe Slot Reassignment is selected.
4
Power on the blades in the FX2s chassis.
5
Set the BIOS setting SR-IOV Global Enable to ENABLED.
To remove the CoreModule FX300
! Caution:
Always use anti-static handling procedures such as wearing a
wrist-strap before handling the CoreModule FX300 module.
1
Shut down any applications running on the CoreModule FX300.
2
Power down the blades that map to the CoreModule FX300 module.
3
Press in the release tab on the top of the module lever.
4
Pull the lever down. This ejects the module from the connectors on the
backplane of the chassis.
5
Carefully draw out the CoreModule FX300 module and fit the connector
protector that came with the unit. See Figure 7.
6
Put in a suitable anti-static bag.
Figure 7: Remove the CoreModule FX300 module from the FX2s chassis