Ambassador Electric Projection Screen by Draper

Copyright © 2008 Draper Inc. Form Ambassador_Inst08 Printed in U.S.A. Caution ➀ Read instructions through completely before proceeding. ➁ Follow instructions carefully. Installation con trary to in struc tions invalidates warranty. ➂ Entire bottom of screen case should be un ob struct ed to permit prop er operation of automatic trap door, and access to bottom panel for making electrical connections or servicing. ➃ Screen should be installed level (using a carpenter’s level). ➄ Nothing should be fastened to screen dowel, viewing surface or auto matic trap door. ➅ Do not touch screen while in motion. ➆ Operating switch(es) packed separately in screen carton. Do not discard with packing material. ➇ Screen operates on 110-120v, 60 hz., .78 amp draw. NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment. Hanging Screen General: When locating viewing surface and checking clear ance for screen operation, remember surface is not centered in case; it is offset to audience’s right (see drawing on back). Normally viewing surface, not case, should be centered in room. Screen is nor mal ly re cessed above ceil ing and may be in stalled in a varie ty of ways. See typical in stal la tion detailed on back of this sheet. Re gard less of mount ing method used, the following points apply: ➀ Screen should be positively and securely sup port ed so that vibration or even abusive pulling on viewing surface will not weaken in stal la tion. ➁ Installer must insure that fasteners used are of adequate strength and suitable for the mounting surface chosen. Screen must be level for satisfactory operation. Use car pen ter’s level. ➂ Entire bottom of case must be readily accessible after installation. (Operating door must be free to open; access door must open to permit electrical connections and limit switch adjustment; semi-permanent bottom panel must be re mov able in case fabric replacement is ever required.) ➃ Hinge on bottom board and particularly hinge on automatic trap door of screen must be per mit ted to operate freely. Front and back of case must be straight—not forced to warp or bow. Hinges must be free from mas tic or paint buildup, and doors must be un ob struct ed by ceiling tiles. ➄ Do not use screen case to support adjacent sections of ceiling. ➅ If trim pieces must be attached to case, do not permit screws to pro trude through ¾" wall of case. Do not attach trim with nails. ➆ Extended hinges are available to allow gluing of ceiling tile when recessed. ➇ If case is painted, slots around doors should be shielded to protect view ing surface from paint splatters or overspray. ➈ Do not seal unit in ceiling until electrical connections have been made and screen has been operated successfully. Electrical Connections Screen operates on 110-120V, 60 hz., .78 amp draw. Junction box for electrical hook-up is located at left end of screen and may be exposed by opening access door and removing box cover. Removal of junc tion box cover plate ex poses red, black and white pigtail leads and green in ter nal ground wire per wiring di a gram on reverse. Screen is shipped with internal wiring complete and control switch(es) fully boxed. Wire connecting screen to switch(es), and switch(es) to power supply should be furnished by installer. Connections should be made in accordance with attached wiring diagram, and wiring should comply with National and local electrical codes. All operating switches should be “off” before power is connected. Adjustments Screen has been factory set and should not nor mal ly require further ad just ment. However, if you desire to change the “up” and “down” stop ping positions, proceed as follows: CAUTION: Be sure all switches are in “off” position before ad just ing limit switches. Always be pre pared to shut screen off man u al ly when new ad just ment is being tested. Screen may be se vere ly dam aged if viewing surface is al lowed to run too far up or too far down. Adjusting “fully up” position — “Up” limit switch is located on bracket at left end of operating door. Raising switch slightly will permit door to close farther; lowering switch will cause door not to close as far. Adjusting “fully down” position — “Down” limit switch is located on left side of limit switch assembly immediately behind access door on left end of case. Left hand, hex head machine screw contacts limit switch button to shut screen off in “Down” position. Turning this ma chine screw clockwise will allow viewing surface to run farther down before stopping. Turning it coun ter clock wise will cause surface to stop in a less extended position. At no time should view ing surface be un rolled far enough to ex pose any part of screen roller. Be sure nut on machine screw is tight against steel plate before closing access door. If you encounter any diffi culty installing or ser vic ing your Ambassador screen, call your dealer or Draper, Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-7142. Operation When screen is fi rst op er at ed, be cautious! If au to mat ic trap door does not drop open im me di ate ly when switch is fl ipped “down”, re turn switch to “off” and free trap door and/or recheck elec tri cal con nec tions before proceeding. Cycle unit down and up several times to confi rm sat is fac to ry operation. 110-120v Single Station Con trol — 3-position up-off-down switch per mits op er a tion to be stopped at any point. Factory adjusted limit switch es automatically stop screen when fully down or fully up. 110-120v Multiple Station Control—Switches are similar in ap pear ance to 110-120v Single Station Control. Screen stops when switch is re leased and may be re start ed in either direction. Factory adjusted limit switch es stop screen au to mat i cal ly when fully up or fully down. 24v Control — Three-button up-stop-down switch es stop at any point desired, operate in any sequence. Factory adjusted limit switches au to mat i cal ly stop screen when fully up or fully down. Key Operated Switching — Two kinds of key-operated switches are op tion al ly available with this unit. ➀ The key-operated power sup ply switch controls power to the screen and switches. When it is “off”, the switches will not operate screen. Key may be removed from the switch in either “on” or “off” position. ➁ A three-po si tion key switch per mits the screen to be operated directly by key. In this case, the screen’s operator must always have a key. RS232/Ethernet—Serial communication and network communication optionally available with wall switches, RF or IR remote. 4" 3" 9 7/8" 5" 10" 10 1/4" Mounting brackets (rods, angles, & attaching hardware by others) Conduit connection on left end Wood case Incl. brackets Ceiling grid and tile (by others) ®

Ambassador Projection Screen by Draper

Standard Construction Offset Construction Extended Hinges for Attachment of Ceiling Tile (Wt. not to exceed 16 oz. per sq. ft.) Single Station Control Junction box at left end of screen Internal Screen Wiring White (Common) Red (Down) Black (Up) Green (Ground) Dashed wiring by installer Control switch Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep Blue Black Red Location of key operated on-off switch if furnished To 110-120v Line Multiple Station Control Junction box at left end of screen Internal Screen Wiring White (Common) Red (Down) Black (Up) Green (Ground) Dashed wiring by installer Red Red Black Blue Blue Cap off with wire nut and tape Black Red Blue Black Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep. 3 shown. More or less equally feasible. Location of key operated on-off switch if furnished To 110-120v Line Motor Motor Case Dimensions Wiring Diagrams Page 2 of 2 Viewing surface 193/8" Conduit connection this side 4" Fabric width + 24" Mounting brackets Motor compartment 97/8" 5" 45/8" Ceiling tile and grid (by others) www.draperinc.com (765) 987-7999 Two-Way Serial Communication (RS232) with MC1 See separate Serial Communication RS232 Instruction sheet for enabling RS232 with the MC1. RS232 Data FROM Control System RS232 Data TO Control System Signal Ground & Manual Switch Common Manual Switch Up Manual Switch Down White-Common to screen & 110-120V AC Neutral Red-to Screen (directional) Brown-to Screen (directional) Black-Hot to 110-120V AC Green/Yellow-Ground Fuse Program LED Eye Port for IR Eye. For RF Receiver or LED Wall Switch, a Splitter and a Power Supply is required. Plug RF Receiver or LED Wall Switch and Power Supply into splitter, then run cable from Splitter to MC1 Eye Port. Low Voltage Wiring by others AC Wiring by electrician MC1 White (Common) Red (Down) Black (Up) Green (Ground) Internal Screen Wiring Location of key operated on-off switch if furnished To 110-120V Line STOP Control Switches 24v DC STOP 3 Button Wall Switch DOWN - Red COM - White UP - Black White-Common to screen & 110-120V AC Neutral Red-to screen (directional) Brown-to screen (directional) Yellow-to 110-120V AC-Hot Black-to 110-120V AC-Hot Green-Ground Eye Port for IR Eye, RF Receiver or LED Wall Switch. For more than one of these, a splitter is required. Aux Port for connecting additional LVC-III modules (up to six total can be linked- connect from Aux to Eye). Dashed wiring by electrician Low voltage wiring by others White (Common) Red (Down) Black (Up) Green (Ground) Internal Screen Wiring Location of key operated on-off switch if furnished To 110-120V Line STOP Control Switches 24v DC STOP Low Voltage and Remote Control

Other Projection Screen Manuals