without permission of the owner. Compro Electronic GmbH Beim Alten Flugplatz 3 49377 Vechta. Germany Tel: +49 4441 / 89112-50 | Fax: +49 4441 / 89112-55 www.compro.de | [email protected] Flash lamp type BEACON 90 USER MANUAL Documentation No:ExS-IO-04-1404.0 EN Edition 01/2014

© Compro Electronic® - all rights reserved. This document may not be copied, reproduced in whole or in part by any means

without permission of the owner. User manual BEACON 90 Page 2 z 6 TABLE OF CONTENTS 1. Compliance with the requirements of the directives 3 2. Description 3 2.1. Technical data: 3 2.2. Parameters of the intrinsic circuit: 3 2.3. Terminal block 4 3. Installation 4 3.1. Assembly 4 3.3. Procedure of installation and connection 4 4. Special conditions of use 5 5. Conditions of use until warranty 5 6. Transport 6 7. Storage 6 8. Maintenance and repairs 6 9. Recycling 6

© Compro Electronic® - all rights reserved. This document may not be copied, reproduced in whole or in part by any means

without permission of the owner. User manual BEACON 90 Page 3 z 6 1. Compliance with the requirements of the directives Compro Electronic as a manufacturer declares that the Flash lamp type BEACON 90 meets the requirements of the Directive 94/9/EC and has been designed in accordance with good engineering practice, especially in the field of explosion safety, and current technical knowledge, under the following harmonized standards under the Directive 94/9/EC: PN-EN 60079-0: 2013-03 + A11:2014- 03 (EN 60079-0:2012 + A11:2013), PN-EN 60079-11:2012 (EN 60079-11:2012), PN-EN 60079-26:2007 (EN 60079-26:2007). Marking I I 1 G Ex ia I IC T 4 Ga 2. Description Flash lamp type BEACON 90 is designed for optical signalling of working conditions or to generate warning signals. Optical signals are generated by LEDs with high life expectancy. Flash lamp as a device group II, category 1G is designed for use in Zone 0 explosive mixture of flammable substances in the form of gases, vapours or mists with air. 2.1. Technical data: Supply voltage 24VDC (reverse polarity protection) Ambient temperature range Ta -40°C ÷ +60°C Degree of protection acc. PN-EN 60529 IP65 Cable entry: Cable gland – cable diameter 4÷6mm Cable connected permanently 4÷8mm Weight 0,4kg Dimensions (ø x H) 95,5mm x 136mm Modes Permanent light Flash light 2.2. Parameters of the intrinsic circuit: PARAMETER VALUE Terminal block J1 + ÷ - Maximum input voltage Ui 28 V DC Maximum input current Ii 660 mA Maximum input power Pi 1,2W Maximum internal capacitance Ci ~0 Maximum internal inductance Li ~0

© Compro Electronic® - all rights reserved. This document may not be copied, reproduced in whole or in part by any means

without permission of the owner. User manual BEACON 90 Page 4 z 6 2.3. Terminal block Mode selection Terminal block of supply + and - Note: during connecting external circuits should pay special attention to the parameters of intrinsically safe circuits specified on the unit. Device should be supplied with intrinsic safe power supply (power supply, barrier) with proven explosion-proof properties EC-type examination certificate with concerning to the output power circuit. The maximum cable length depends on the parameters specified in the certificate of the power supply or barriers and cannot be exceeded. 3. Installation Flash lamp type BEACON 90 is placed in a plastic housing. Housing provides a degree of protection IP65 provide adequate choking the power cable and the use of mounting screws sealings. 3.1. Assembly The device can be mounted to any flat surface by means of two fixing screws from the inside of the base. After attaching the base, the screw holes must be plugged by blanking plugs supplied with the device. 3.3.Procedure of installation and connection  To remove the lid, turn the lamp lid clockwise (to the right). Remove the lid, making sure that the sealing type o-ring remains in place.  Remove the electronics by removing the two screws that secure it to the base.  Remove blanking plugs from mounting holes and assembly lamp base to a flat surface. Then and shut the mounting holes.  In the version with cable gland enter the power cable through the prepared cable

© Compro Electronic® - all rights reserved. This document may not be copied, reproduced in whole or in part by any means

without permission of the owner. User manual BEACON 90 Page 5 z 6 gland, connect the wires to the terminal block J1 maintaining proper polarity.  Verify that a sealing type o-ring has not been damaged and is in place. Put the lamp lid and turn counter-clockwise (to the left). 4. Special conditions of use The device housing is made of plastic and can cause electrostatic discharges able to ignite the explosive atmosphere under certain extreme conditions. The user must ensure that the device will not be installed in a location where it can be under extreme conditions that could cause electrostatic discharge on the surfaces of plastics. Clean only with a damp cloth with addition of antistatic detergent. 5. Conditions of use until warranty Condition of warranty is keep to the following requirements: • compliance with the recommendations contained in the manual • preservation of the (serial number identifying the product) • use of the product as intended

© Compro Electronic® - all rights reserved. This document may not be copied, reproduced in whole or in part by any means

without permission of the owner. User manual BEACON 90 Page 6 z 6 6. Transport Transportation should be done using covered transport means, protected from rain, strong shocks and impacts at ambient temperature -40C + 60C. 7. Storage Flash light BEACON 90 should be storage in closed storage room at ambient temperature - 40C + 60C in atmosphere free of aggressive vapours and gases 8. Maintenance and repairs Maintenance is reduced to periodic inspection of cleanliness. In case of malfunction, check the connection of electrical circuits and the presence of voltage. It is not allowed to make any repairs and changes in the structure of the device. Any repair performs only the manufacturer's service! 9. Recycling The device has no components dangerous to health and life. Please note that this product after the exploitation cannot be treated as household waste. By ensuring proper storage will help prevent the negative effects of threatening the environment and human health. Recycling helps protect the environment. For more detailed information about recycling, please contact your city office, or the manufacturer of the device.