Digi DC-400 Operation Manual

Specifications

Brand: Digi
Category: Scales
Model: DC-400 (Operation Manual)
File Type: PDF
File Size: —
Pages: 68

Read Online

Read the Digi DC-400 Operation Manual online using the built-in PDF viewer.

Text of the manual

Shanghai Teraoka Electronic Co., Ltd.

2C-5F Shanghai Tianhua Information Technology Park No.299, Long Cao Road, Xu Hui District Shanghai China, 200235 Tel: +86-21-64085151 Fax: +86-21-64083468

1. General Information .......................................................................................................... 1

1.1. General Layout ................................................................................................................................ 1 1.1.1. 500g/5kg Capacity ............................................................................................................................... 1 1.1.2. 2.5kg/25kg Capacity ............................................................................................................................ 2 1.2. Features ........................................................................................................................................... 3 1.3. Operating Conditions ...................................................................................................................... 3 1.4. Dimensions...................................................................................................................................... 3 1.4.1. 500g/5kg Capacity ............................................................................................................................... 3 1.4.2. 2.5kg/25kg Capacity ............................................................................................................................ 3 1.5. Display and Indicators .................................................................................................................... 4 1.5.1. Display Specifications ......................................................................................................................... 4 1.5.2. Indicators ............................................................................................................................................. 4 1.6. Key .................................................................................................................................................. 4 1.6.1. Key Sheet Layout ................................................................................................................................ 4 1.6.2. Key Functions ..................................................................................................................................... 5 2. Setup .................................................................................................................................. 6 2.1. Mode Change .................................................................................................................................. 6 2.2. Specification Setting ....................................................................................................................... 7 2.2.1. Specification Entry (141) .................................................................................................................... 7 2.2.2. Specification List ................................................................................................................................. 8 2.3. Password Setting ........................................................................................................................... 18 2.3.1. Procedures of Password Setting ........................................................................................................ 18 2.3.2. Password Using ................................................................................................................................. 19 2.4. Clear Files ..................................................................................................................................... 19 3. Program Mode ................................................................................................................. 20 3.1. Programmable Files ...................................................................................................................... 20 3.2. Programming Mode Entry ............................................................................................................ 20 3.3. PLU FILE ...................................................................................................................................... 21 3.3.1. Program Item File .............................................................................................................................. 21 3.3.2. Delete Item Code ............................................................................................................................... 23 3.3.3. Label Format List .............................................................................................................................. 24 3.4. FACTORY NAME FILE .............................................................................................................. 25 3.4.1. Program Factory Name File .............................................................................................................. 25 3.4.2. Print Factory Name File .................................................................................................................... 25 3.4.3. Delete Factory Name File.................................................................................................................. 26 3.5. PROGRAM DATE AND TIME ................................................................................................... 26 3.6. ADDRESS FILE ........................................................................................................................... 27 3.6.1. Program Address File ........................................................................................................................ 27 3.6.2. Print Address File .............................................................................................................................. 27 3.6.3. Delete Address File ........................................................................................................................... 28 3.7. TEXT FILE ................................................................................................................................... 29 3.7.1. Program Text File .............................................................................................................................. 29 3.7.2. Print Text File .................................................................................................................................... 29 3.7.3. Delete Text File ................................................................................................................................. 30 3.8. FREE FORMAT FILE .................................................................................................................. 30 3.8.1. General Information .......................................................................................................................... 30 3.8.2 Print Area, Print Position and Print Angles ........................................................................................ 31 3.8.3 Programming Parameter of Print Items .............................................................................................. 33 3.8.4 Free Format Entry .............................................................................................................................. 35 3.8.5 Free Format Copy Function ............................................................................................................... 41 3.8.6 Free Format Delete Function .............................................................................................................. 41 3.8.7 Sample of program a format by modifying the existing format ......................................................... 42 3.9 Logo File ........................................................................................................................................ 44

3.9.1 Pre-programming Logo Data .............................................................................................................. 44

3.9.2 Program Display & Keys Function .................................................................................................... 45 3.9.3 Programming Order ............................................................................................................................ 46 3.9.4 Program Logo File ............................................................................................................................. 46 3.9.5 Delete Logo File ................................................................................................................................. 47 3.10 Memory Status ............................................................................................................................. 47 3.11 Program Multi-barcode File ......................................................................................................... 48 3.11.1. Program Multi-barcode File ............................................................................................................ 48 3.11.2. Delete Multi-barcode File ............................................................................................................... 48 3.12. 2D BARCODE TEXT FILE ....................................................................................................... 49 3.12.1. Program 2D Barcode Text File ....................................................................................................... 49 3.12.3. Delete 2D Barcode Text File ........................................................................................................... 49 4. REGISTRATION MODE ............................................................................................... 50 4.1 ON/OFF ......................................................................................................................................... 50 4.2 Reset and Weighing Check ............................................................................................................ 50 4.3 Tare Subtraction ............................................................................................................................. 50 4.3.1 One touch Tare Subtraction ................................................................................................................ 50 4.3.2 Digital tare Subtraction ...................................................................................................................... 51 4.4 Item Call Up ................................................................................................................................... 51 4.5 Set New Item Code in Registration Mode ..................................................................................... 51 4.6 Manual Print ................................................................................................................................... 52 4.6.1 Item Label Printing ............................................................................................................................. 52 4.6.2 Total Label Printing ........................................................................................................................... 52 4.7 Accumulation and Subtraction ....................................................................................................... 53 4.8 Unit Weight Operation ................................................................................................................... 54 4.8.1 Unit Weight Setting in Operation Mode ............................................................................................ 54 4.8.2 Re-computing Unit Weight in Memory ............................................................................................. 55 4.9 Inventory Operation ....................................................................................................................... 56 4.9.1 Manual Transaction ............................................................................................................................ 56 4.9.2 Total Transaction ................................................................................................................................ 57 4.10 Function key ................................................................................................................................. 58 4.10.1 Net/Gross Key .................................................................................................................................. 58 4.10.2 Switch Platform Key ........................................................................................................................ 58 4.10.3 Switch Weight Unit Key .................................................................................................................. 59 4.10.4 View Item Key ................................................................................................................................. 59 4.10.5 Address No Key ............................................................................................................................... 60 4.10.6 Lot No Key ....................................................................................................................................... 61 4.10.7 Sequence No. Key ............................................................................................................................ 61 5. Report Mode .................................................................................................................... 62 5.1. Report Type Selection ................................................................................................................... 62 5.2. Report Mode Entry........................................................................................................................ 62 5.3. Item Report ................................................................................................................................... 62 5.3.1 One Item Print .................................................................................................................................... 62 5.4. Inventory Report ........................................................................................................................... 64 5.4.1 Print Threshold Report ....................................................................................................................... 64 5.4.2 Print In / Out Count Report ................................................................................................................ 64 5.4.3 Clear In / Out Count Report ............................................................................................................... 65 5.5. SHELF LOCATION PRINT ........................................................................................................ 65

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 1 of 65 1. General Information 1.1. General Layout 1.1.1. 500g/5kg Capacity

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 2 of 65 1.1.2. 2.5kg/25kg Capacity

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 3 of 65 1.2. Features  Digital printing scale consists of counting function and label printing function.  High-speed, high reliability thermal head printer, the Max. printing width is 60mm, the Max. printing speed is 110mm/sec.  Easy paper handing achieved special designed mechanism.  Built-in clock automatically updates date and time.  Quick response to weight changes.  Capacity : 500g/5kg, 2.5kg/25kg.  High Resolution : Display Resolution 1/50,000, 4-interval. : Internal Resolution 1/1,000,000.  Remote platform connector support 4 x load cells 350 Ohm.  202 x 32 pixels FSTN type LCD with back-light.  Touch Panel Integrated.  55 switch keys a. ON/OFF key. b. 10 Numeric keys, to key in numeric data. c. 26 character keys, to key in characters. d. 18 Operational keys, to perform various functional operations.  Ethernet function.  RS232C I/F for data communication and barcode scanner connection.  PS/2 I/F for IBM keyboard 1.3. Operating Conditions  Power Source : AC 176V ~ 264V, 47~63Hz.  Operating Temperature : -10 C ~ +40 C.  Operating Humidity : 15% ~ 85% RH.  Power Consumption : 0.5A. 1.4. Dimensions 1.4.1. 500g/5kg Capacity  Platter size : 215(W) x 162(D) mm.  Overall size : 360(W) x 465(D) x 159(H) mm. 1.4.2. 2.5kg/25kg Capacity  Platter size : 290(W) x 215(D) mm.  Overall size : 360(W) x 465(D) x 162(H) mm.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 4 of 65 1.5. Display and Indicators DC-400 per 1000pcs 1 2 1.5.1. Display Specifications  Weight display : 6 digits.  Unit Weight display : 7 digits.  Quantity : 8 digits.  Second Line display : 25 characters. 1.5.2. Indicators  ZERO : On when zero point is adjusted and weight is stable.  NET : On when tare subtraction is performed.  SCALE-1 : On when Scale 1(Built-in Platform) is selected.  SCALE-2 : On when Scale 2(Remote Platform) is selected.  RECOM : On when Unit Weight re-computing is possible.  INSUFF : On when Net weight is below a specific percentage of the capacity weight.  LABEL : On when label printing mode is chosen.  ∑ : On when Quantity accumulation is done.  IN : On when Inventory IN (For Counting Mode)  OUT : On when Inventory OUT (For Counting Mode)  X : On when in Report mode.  S : On when in Programming mode.  Z : On when in Service mode. 1.6. Key 1.6.1. Key Sheet Layout OFF LOT NO SHIFT UP SHIFT DOWN SCALE ! # $ % & " ( ) + ; * / - @ ′ .

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 5 of 65 1.6.2. Key Functions  : ON/OFF key. Turn display on or off.  : Print key. Issue label or receipt at R mode / Print out report at X mode / To enter item programmed mode.  PIECES : PCS key. To computing unit weight by sampling / Escape the Programming screen without saving data in X and S mode  UNIT WEIGHT: UNIT WEIGHT key. To set Unit Weight in Registration mode.  : MODE SET key. To switch into control modes.  CODE : CODE key. Call up PLU data in Registration mode / Store the programmed data in S mode.  : Feed key. To feed paper.  + : PLUS key. Accumulate the Total Quantity / Select programming item such as Item Code, Factory Name in S mode / Select Report Type in X Mode.  - : MINUS key. Correct the sales data / Select programming item such as Item Code, Factory Name in S mode / Select Report Type in X mode.  CLEAR : CLEAR key. Clear Alphanumeric Data / Select "YES" in S, X and Z mode.  : RE-ZERO key. Reset weight display to zero.  : TARE key. Set or clear tare values / Select "NO" in S, X and Z mode / Item test print in S mode.  0 ~ 9 : Numeric keys. Input numerical value.  . : DOT key. To enter Decimal point.  A to Z : Character keys. To view the Preset data such as ID CODE, PART NAME in R mode / Enter Alphabetic data in R mode (ID CODE) and S mode.  SCALE : SCALE key. To switch between scale1 and scale2  LOT NO : LOT NO key. To view the Lot Number or to program new Lot Number for temporarily printing.  SHIFT UP : SHIFT UP key. To select Top function or symbol of the desired key for entering.  SHIFT DOWN : SHIFT DOWN key. SCALE key. To select Bottom function of desired key for entering.  << : LEFT SHIFT key. To move cursor LEFT.  >> : RIGHT SHIFT key. To move cursor RIGHT.  SPACE : SPACE key. To SPACE the entering characters or numbers.  INSERT : INSERT key. Insert Data..  DEL : DELETE key. Delete the Data.  CHAR TYPE : CHARACTER TYPE key. Code type entered.  LETTER SZ : LETTER SIZE key. Switch Cap or Lower case..  CHAR SZ : CHARACTER SIZE key. Change Font size.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 6 of 65 2. Setup 2.1. Mode Change OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY 0.0000kg 0 0 R mode. [MODE][MODE] (within 3 seconds) X1.0 ITEM REPORT Enter X mode. Lamp X turns on. [MODE] S1 PLU FILE Enter S mode. Lamp S turns on. [MODE] SERVICE MODE Enter Z mode. Lamp Z turns on. [MODE] PWD X 0 SET Enter Password Set mode. [MODE] 0.0000kg 0 0 Return to R mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 7 of 65 2.2. Specification Setting 2.2.1. Specification Entry (141) OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY SERVICE MODE Z mode. Lamp Z turns on. [Rezero]+[1][4][1] SPEC 000 XXX (setting) XXX (former) Enter [1][4][1] while depressing [Rezero]. XXX:SPEC data [+] SPEC 001 XXX XXX [+] key only increase specification count, it does not update SPEC data. [-] SPEC 000 XXX XXX [-] key only decrease specification count, it does not update SPEC data. [1][7] [PIECES] SPEC 000 SPEC 017 017 XXX XXX XXX It goes to a designed specification count. (000~062 is enabled) [>>] SPEC 017 XXX XXX [>>] key select SPEC data. Move cursor right. [<<] SPEC 017 XXX XXX [<<] key select SPEC data. Move cursor left. [1] [*] SPEC 017 SPEC 018 001 XXX XXX XXX [C] SPEC 018 000 XXX Clear the enter data. [CODE] * Note SERVICE MODE Store the updated specification and escape to Z mode. Note: If press [T] key, it does not store the updated specification and escape to Z mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 8 of 65 2.2.2. Specification List Customer SPEC Setting-(141) SPEC NO. SPECIFICATION DESCRIPTION DC-400 00 AUTO POWER SAVING WHEN NO WEIGHT CHANGE & NO KEY PRESS  0 Inhibit 3 30 Minutes 1. When SPEC1 set to 0, backlight will off and when SPEC1 set to 1, the scale will auto power off. 1 3 Minutes 4 1 Hour 2 10 Minutes 5 3 Hours 01 POWER SAVING MODE 0 Back Light Off 1 POWER OFF . 02 NEGATIVE COUNTING  0 No 1 Yes 03 EXTENT OF INSUFFICIENT SAMPLES  0 0.1% 2 0.0% 1 0.2% 04 SET NEW ITEM DURING REGISTRATION MODE  0 Yes 1 No 05 DATE ORDER  0 Month / Day / Year 2 Year / Month / Day 1 Day / Month / Year 06 TIME FORMAT  0 24 Hour 1 12 Hour (am / pm) 07 UNIT WEIGHT AUTO RECOMPUTING 0 No 1 Yes 08 SAMPLING TIMES FOR UNIT WEIGHT CALCULATION  0 15 Times 1 20 Times 09 DISPLAY ACCURACY UNIT WEIGHT CALCULATION DURING RECOMPUTING 0 No 1 Yes 10 SET POINT BUZZER  0 Buzzer On 1 Buzzer Off 11 CLEAR ALL INPUT KEY IN ONE TOUCH 0 Yes 1 No 12 KEEP LOT NO IN REGISTRATION MODE  0 Allow 1 Inhibit 13 JOB SEQUENCE 0 Disable 1 Enable 14 AUTO EXIT FROM ADD MODE  0 No 1 Yes

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 9 of 65 SPEC NO. SPECIFICATION DESCRIPTION DC-400 15 SIO SELECT JOB 0 No Operation 3 PC Connection Please set SPEC29 force balance to ENABLE when SPEC26 is set to FORCE BALANCE. 1 Track N Print (TNP) 4 Printer Connection 2 Force Balance (FB) 5 Barcode Scanner 16 RS232C BAUD RATE (SIO)  0 1200 3 9600 1 2400 4 19200 2 4800 5 38400 17 RS-232C DATA LENGTH (SIO)  0 7 Bits 1 8 Bits 18 RS-232C PARITY BIT (SIO)  0 None 2 Even 1 Odd 19 RS-232C STOP BIT (SIO)  0 1 Bit 1 2 Bits 20 RS232 OPTION CARD WITH 8 PIN DIN2 AND 8 PIN DIN1 CONNECTORS 0 Not Connected 4 PC / Printer Please set SPEC29 force balance to ENABLE when connected to FORCE BALANCE. 1 Printer / Force Balance 5 PC / Force Balance 2 Force Balance / Printer 6 Force Balance / PC 3 Printer / PC 21 RS-232 BAUD RATE FOR 8 PIN DIN1 CONNECTOR (OPTIONAL CARD) 0 4800 2 19200 1 9600 3 38400 22 RS-232 DATA LENGTH FOR 8 PIN DIN1 CONNECTOR (OPTIONAL CARD) 0 7 Bits 1 8 Bits 23 RS-232 STOP BIT FOR 8 PIN DIN1 CONNECTOR (OPTIONAL CARD) 0 1 Bit 1 2 Bits 24 RS-232 PARITY BIT FOR 8 PIN DIN1 CONNECTOR (OPTIONAL CARD) 0 None 2 Even 1 Odd 25 RS-232 BAUD RATE FOR 8 PIN DIN2 CONNECTOR (OPTIONAL CARD) 0 4800 2 19200 1 9600 3 38400 26 RS-232 DATA LENGTH FOR 8 PIN DIN2 CONNECTOR (OPTIONAL CARD) 0 7 Bits 1 8 Bits 27 RS-232 STOP BIT FOR 8 PIN DIN2 CONNECTOR (OPTIONAL CARD) 0 1 Bit 1 2 Bits

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 10 of 65 SPEC NO. SPECIFICATION DESCRIPTION DC-400 28 RS-232 PARITY BIT FOR 8-PIN DIN2 CONNECTOR (OPTIONAL CARD) 0 None 2 Even 1 Odd 29 RS-232 CONNECTION TO FORCE BALANCE (FB) 0 Disable 1 Enable 30 TYPE OF FORCE BALANCE 0 Export 2 SHG-200 (JAPAN) 1 HR-60 (JAPAN) 3 SHG-300 (JAPAN) 31 PC/PRN OUTPUT DATA METHOD 0 No Operation 2 By +/-/Print Key (PC/PRN) 1 Count Condition (PC only) 3 For Both Cases 1 & 2 32 SELECT EXTERNAL PRINTER TYPE 0 ELTRON LP2622/LP2722 OR TVP1000 2 DP122 (JAPAN) 1 SE250 33 EXTERNAL ELTRON/TVP PRINTER DOWNLOAD LABEL FORMAT 0 Enable 1 Disable 34 PRINT WHEN PRESS +/- KEY 0 Disable 1 Enable 35 PC DATA WITH HEADER 0 Yes 1 No 36 PC DATA HEADER TYPE 0 Code 1 Title 37 BARCODE SCANNER (BCS) CONNECTION  0 Disable 1 Enable 38 BARCODE SCANNER (BCS) WITH HEADER 0 Yes 1 No 39 TRACK NPRINT (TNP) TIME OUT 0 2 Seconds 2 32 Seconds 1 8 Seconds 40 SELECTION OF TRACK NPRINT (TNP) NETWORK INTERFACE 0 No Interface (RS232) 2 Ethernet - Twisted Cable 1 Ethernet - Coaxial Cable 41 PORT NUMBER (IP ADDRESS)  Range (1 - 254) 42 SET SCALE NUMBER  Range (0 - 999999)

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 11 of 65 SPEC NO. SPECIFICATION DESCRIPTION DC-400 43 SELECT RECEIPT OR LABEL PAPER PRINTING 0 Print Receipt Paper 1 Print Label Paper 44 PRINTING SPEED FOR RECEIPT  0 Slow 2 High 1 Normal 45 PRINTING SPEED FOR LABEL  0 Slow 2 High 1 Normal 46 LABEL PRINTING DENSITY  0 Low 2 Medium High 1 Medium 3 High 47 LABEL TYPE (DC300 only)  0 Gap 1 No Gap 48 PEEL SENSOR FUNCTION 0 Disable 1 Enable 49 NO OF REPRINT LABELS 0 No Label 2 2 Labels 1 1 Label 50 SELECTION OF LABEL AND RECEIPT PRINTING OPERATION 0 All Operation (In/Out/Non-Add) 3 In & Out (Receiving & Shipping) 1 Out (Shipping Operations) 4 No Printing 2 In (Receiving Operations) 51 HUMAN READABLE BARCODE PRINTING FORMAT 0 No Print 1 Print 52 ITEM DATA (SUCH AS ID CODE, PART NAME, PART NO & LOT NO) PRINTING FORMAT  0 Centering 1 Start Printing From Left 53 DATE TITLE PRINT  0 No 1 Yes 54 WEIGHT DATA AND QUANTITY TITLE PRINT 0 No Print 1 Print 55 PRINTING OF FACTORY NAME ON LABEL  0 No Print 1 Print 56 DEFAULT PRINTING LABEL FACTORY NO  Range (0 - 32) 57 PRINTING OF FACTORY NAME FORMAT  0 No Centering 1 Centering

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 12 of 65 SPEC NO. SPECIFICATION DESCRIPTION DC-400 58 SELECTION OF LABEL LOGO PRINTING STATUS  0 No Print 3 Logo 3 1 Logo 1 4 Logo 4 2 Logo 2 59 SELECTION OF BARCODE TYPE  0 Code128 2 Code39 1 Ean128 60 AUTO PRINT FUNCTION 0 Between Set Point 1 And Set Point 2 1 Disable 61 ETHERNET FUNCTIONS 0 No Operation 2 Data Transfer Mode 1 Scale Genie 62 RS232C SOFTWARE HANDSHAKING XON/XOFF 0 Disable 1 Enable 63 SAMPLE QUANTITY  0 10 Pcs 2 50 Pcs 1 25 Pcs 3 100 Pcs 64 SCALE A  B 0 Manual 1 Auto 65 UNIT OF Pcs WT 0 1000 Pcs 1 1 Pcs 66 RESERVED 67 IMS 0 Disable 1 Enable 68 EPSON II 0 Disable 1 Enable 69 4 LOT NO 0 Disable 1 Enable 70 UPD LOT & PART NM 0 Disable 1 Enable 71 TEXT 11-16 IN TTL  0 Disable 1 Enable 72 COMMA IN QUANTITY 0 Disable 1 Enable 73 PRINT BARCODE 0 With Header 2 QTY Without Header 1 All Without Header

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 13 of 65 SPEC NO. SPECIFICATION DESCRIPTION DC-400 74 OVERWRITE UNIT WT 0 No 1 Yes (If Unit WT = 0) 75 RESET SEQ NO 0 No 1 Yes (When Print) 76 SELECTABLE PRINTE 0 Disable 1 Enable 77 SELECTABLE PRINTS 0 Disable 1 Enable 78 TRANSACTION ABC 0 Disable 1 Enable 79 ID MANAGER 0 Disable 1 Enable 80 DHCP  0 Disable 1 Enable 81 2D ITEM-TTL SEQ# 0 Disable 1 Enable 82 TTL SEQ NUM INC 0 Yes 1 No 83 WIRELESS COMM 0 Disable 1 Enable 84 SELECT UW/SCALE 0 Disable 1 Enable 85 SCALE 1 PER PCS 0 Disable 1 Enable 86 SCALE 2 PER PCS 0 Disable 1 Enable 87 SCALE 3 PER PCS 0 Disable 1 Enable 88 SCALE 4 PER PCS 0 Disable 1 Enable 89 AUTO PRINT COND 0 No Condition 1 WT = Below 90 PRINT CONDITION 0 No Condition 1 Lot Number 91 SP BUZZER COND  0 Standard 2 Outside Set Point 1 Inside Set Point

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 14 of 65 SPEC NO. SPECIFICATION DESCRIPTION DC-400 100 SERVER IP ADDRESS  Range (1 - 255) For Client scale only 101 ON/OFF KEY  0 Enable 1 Disable 102 BLACK BAR SENSING LABEL  0 Normal 1 Black Bar Sensing 103 TRANSPARENT FILM LABEL  0 No 1 Yes 104 PRINT CHECKING LINE  0 Print 1 No Print 105 LABEL PRINT ORIENTATION  0 From Bottom 1 From Top 106 DEFAULT LABEL FORMAT FOR ITEM PRINTING  0 T1 Not Used [A] 12 S (T6) [T7] Formats in ( ) are for U1 only. Formats in [ ] are for CA only. F1 to F8 are Free Format. 1 T2 (A) [B] 13 A (T7) [T8] 2 T3 (B) [C] 14 B (T8) [T9] 3 T4 (C) [U2] 15 C (T9) [T10] 4 T5 (U2) [U3] 16 F1 (T10) [F1] 5 T6 (U3) [U4] 17 F2 (F1) [F2] 6 T7 (U4) [U5] 18 F3 (F2) [F3] 7 T8 (U5) [U6] 19 F4 (F3) [F4] 8 T9 (U6) [U7] 20 F5 (F4) [F5] 9 T10 (U7) [U8] 21 F6 (F5) [F6] 10 T11 (U8) [T5] 22 F7 (F6) [F7] 11 T12 (T5) [T6] 23 F8 (F7) [F8] 24 - (F8) - 107 DEFAULT LABEL FORMAT FOR TOTAL PRINTING  0 T1 Not Used [A] 12 S (T6) [T7] Formats in ( ) are for U1 only. Formats in [ ] are for CA only. F1 to F8 are Free Format. 1 T2 (A) [B] 13 A (T7) [T8] 2 T3 (B) [C] 14 B (T8) [T9] 3 T4 (C) [U2] 15 C (T9) [T10] 4 T5 (U2) [U3] 16 F1 (T10) [F1] 5 T6 (U3) [U4] 17 F2 (F1) [F2] 6 T7 (U4) [U5] 18 F3 (F2) [F3] 7 T8 (U5) [U6] 19 F4 (F3) [F4] 8 T9 (U6) [U7] 20 F5 (F4) [F5] 9 T10 (U7) [U8] 21 F6 (F5) [F6] 10 T11 (U8) [T5] 22 F7 (F6) [F7] 11 T12 (T5) [T6] 23 F8 (F7) [F8] 24 - (F8) - 108 PRINT MANUAL WEIGHT SIGNATURE ON ITEM LABEL  0 Inhibit 1 Allow For WG 109 LEFT ALIGNMENT OF PRICE AND WEIGHT ON LABEL  0 No 2 Weight 1 Price 3 Price & Weight

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 15 of 65 SPEC NO. SPECIFICATION DESCRIPTION DC-400 110 PRINT $ AND WEIGHT UNIT ON LABEL  0 No Print 1 Print 111 PRINTING OF CHECKSUM FOR ITEM BARCODE  0 Disable 1 Enable For Code39 only. 112 ZERO SUPPRESS FOR DATE AND TIME  0 Disable 1 Enable 113 ENLARGE LINE SPACING FOR G3 FONT ON ITEM LABEL  0 Inhibit 1 Allow For CN only. 114 ALIGNMENT OF COMMODITY NAME ON LABEL  0 Center 2 Justify 1 Left 115 CONTINUOUS LABEL  0 Disable 1 User Programmable # For CN. 116 MULTI BARCODE TYPE  0 EAN128 5 GS1 DataMatrix # # For multi barcode 2 only. 1 RSS 6 GS1 DataBar Composite # 2 CODE128 7 Codabar 3 PDF417 # 8 Code39 4 GS1 QR Code # 9 GM Code # 117 ENABLE PASSWORD MODE  0 Allow 2 Allow Multi Password 1 Inhibit 118 YEAR FORMAT  0 YY 1 YYYY 144 PRINTING POSITION OFFSET FOR RECEIPT  0 0mm (Standard) 5 - 1mm 1 1mm 6 - 2mm 2 2mm 7 - 3mm 3 3mm 8 - 4mm 4 4mm 120 CHARACTER SIZE FOR BARCODE DATA  0 Large 1 Small 121 PRINT FORMAT OF MONTH  0 Number 2 3 Alphabetic 1 2 Alphabetic 122 NUMERIC KEY ENTRY RESET  0 3 sec 2 Disable For AA. 1 5 sec

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 16 of 65 SPEC NO. SPECIFICATION DESCRIPTION DC-400 123 TOTAL LABEL PRINTING  0 No Print 1 Print 124 TARE OVERRIDE  0 Allow 1 Inhibit 125 SETTING OF CLIENT / SERVER  0 Client 1 Server / Workstation 126 MASK BARCODE LAST HUMAN READABLE CHECK DIGIT  0 No 1 Yes 127 WIRELESS COMMUNICATION  0 No 1 Yes 128 PRINT CONTROL FOR IMAGE  0 Disable 1 Enable 129 GRATUITOUS ARP  0 Disable 1 Enable 130 RTS/CTS HANDSHAKING OF RS-232C  0 On 1 Off 131 SYMBOL FORMAT FOR DATE PRINT  0 Dash 2 Null 1 Period 132 WIDTH OF STACKED SYMBOL IN SEGMENTS FOR RSS BARCODE  0 2 2 6 Effective when SPEC116 = 1. 1 4 3 8 133 THE PRINTED QUALITY OF 2D BARCODE  0 Mid 2 High 1 High-Mid 3 Highest (For QR Code only) 134 RSS AND 2D BARCODE HUMAN READABLE INTERPRETATION PRINT  0 All 2 No Print 1 GTIN only 135 BARCODE CHECK LINE  0 Print 1 No Print 136 FEED FOR CONTINUOUS LABEL  0 No 1 Yes 137 GAP VALUE IN-FEED OPERATION  0 Re-adjustable 1 No Change

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 17 of 65 SPEC NO. SPECIFICATION DESCRIPTION DC-400 138 WEIGHT DATA SYNCHRONIZATION FUNCTION  0 Allow 2 Enforce 1 Inhibit 139 FORCED FEED PAPER AFTER OPEN THERMAL HEAD  0 No 1 Yes 140 RECALCULATE LABEL AND GAP VALUE BY REZERO + FEED KEY  0 Allow 1 Inhibit 141 FTP CLIENT AUTO CONNECTION INTERVAL (MINUTE)  Enter a value between 0 to 9999 For Client scale only. 142 FTP CLIENT DATA CONNECTION MODE  0 Port 1 PASV For Client scale only. 143 ETHERNET IC RESET INTERVAL (MINUTE)  Enter value from 5 to 999

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 18 of 65 2.3. Password Setting 2.3.1. Procedures of Password Setting OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY SERVICE MODE Z mode. Lamp Z turns on. [MODE] PWD X XXXX SET Display password for X mode. XXXX: former password 0: Not set (1~ 6 bits are enable) [1][2][3][4] [*] PWD X PWD S 1234 XXXX SET SET Set password for X mode as 1234. Press [*] to save password for X mode. [*] PWD Z XXXX SET Display password for Z mode. [3][3] [C] PWD Z PWD Z 33 0 SET SET Clear the password for Z mode. [*] PWD P XXXX SET Display password for PWD mode. [1][1][1][1] PWD P 1111 SET Set password for PWD mode as 1111. [*] 0.0000kg 0 0 Return R mode after password setting.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 19 of 65 2.3.2. Password Using {Hypothesis: PWD X: 1111; PWD S: No Set; PWD P: 1234} OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY 0.0000kg 0 0 R mode. [MODE][MODE] (within 3 seconds) ENTER PWD X Need X mode password. Lamp X turns on. [1][2][3][4] [*] ENTER ENTER **** PWD X PWD X Incorrect password. Retry. [1][1][1][1] [*] ENTER X1.0 **** REPORT PWD X ITEM Correct password. Enters X mode. [MODE] S1 ITEM CD → Enters S mode. Lamp S turns on. [MODE] ENTER PWD Z Need Z mode password. Lamp Z turns on. [3][3] [*] ENTER ** MODE PWD Z SERVICE Correct password. Enters Z mode. [MODE] ENTER PWD P Need PWD mode password. [1][2][3][4] [*] ENTER PWD X **** SET PWD P 1111 Correct password. Enters PWD mode. [MODE] 0.0000kg 0 0 Return to R mode. 2.4. Clear Files This function is used to clear files in Memory. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY SERVICE MODE Z mode. Lamp Z turns on. [Rezero]+[2][3][0] CLEAR PLU FILE PLU file. [+] CLEAR REPORT FILES Select to clear report files. [+] CLEAR MEMORY DATA Select to clear memory. [*] CLEAR MEMORY Y-C N-T To clear memory. [C] or [T] SERVICE MODE [C] to clear file data, [T] to quit. Return to Z mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 20 of 65 3. Program Mode 3.1. Programmable Files In Programming Mode, there are two ways to select the Programming File by using different keys such as:  Enter the Number key.  Press [+] key or [-] key to select the Data File. The files listed below can be programmed in PROGRAM Mode (S Mode). Key To Press Data Files [1] PROGRAM PLU [2] PROGRAM FACTORY [4] PROGRAM DATE AND TIME [5] PROGRAM ADDRESS [7] PROGRAMM TEXT [8] PROGRAM FREE FORMAT [9] PROGRAM LOGO [1] [0] MEMORY STATUS [1] [1] INTERFACE TEST [1] [2] PROGRAM MULTI-BARCODE [1] [3] PROGRAM 2D BARCODE TEXT 3.2. Programming Mode Entry OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY 0.0000kg 0 0 R mode. Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Program PLU file. [2] or [+] S2 FACTORY FILE Press [+] key to select next programming file. Press [MODE] key 3 times. 0.0000kg 0 0 Return to R mode

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 21 of 65 3.3. PLU FILE The following items can be programmed in PLU PROGRAMMING mode. Step Items Step Items S1.0 ID CODE ENTRY S1.7 LOCATION S1.1 UNIT WEIGHT S1.8 INVENTORY S1.2 TARE WEIGHT S1.9 THRESHOLD S1.3 LABEL FORMAT S1.10 SELECT SET POINT TYPE S1.4 PART NAME S1.11 SET POINT 1 S1.5 PART NUMBER S1.12 SET POINT 2 S1.6 LOT NUMBER S1.13 ADDRESS NUMBER (if Address exist) 3.3.1. Program Item File Item data is programmed by the following procedure. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [*] S1.0 NO SET Enter PLU programming mode. [1][2][3][A][B][*] S1.1 0.0000 0 Enter ID Code (Ex. 123AB). [0][.][1][*] S1.2 0.0000 0 Enter Unit Weight (Ex. 0.1). * Note 1 [TARE][*] S1.3 DEF 0 LAB FR Place a tare weight on platter (Ex. 100g). If the tare value is known, enter the tare value by numeric keys. [<<] or [>>] S1.3 T6 6 LAB FR Select Label format by press [<<] or [>>] key. [*] S1.4 P 0101 S1 A 70 Set the Label format (Ex. T6). [P][A]…[E][*] S1.5 N 0101 S1 A 70 Enter Part Name (Ex. PART NAME). * Note 2 [P][N]…[1][*] S1.6 L 0101 S1 A 70 Enter Part No. (Ex. PN001). * Note 2 [L][N]…[1][*] S1.7 C 0101 S1 A 70 Enter Lot No. (Ex. LN001). * Note 2 [L][N]…[1][*] S1.8 INVENT 0 Enter Location (Ex. LC001). * Note 2

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 22 of 65 OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY [1][0][0][0][*] S1.9 THRES 0 Enter Inventory (Ex. 1000). * Note 3 [5][0][*] S1.10 %/QTY Enter Threshold (Ex. 50). * Note 3 [+][*] S1.10 0 0 Select set point type by press [+] key. [2][0][0][*] S1.12 0 0 Enter Set Point 1 (Ex. 200). * Note 4 [4][0][0][*] S1.13 ADDRESS 0 Enter Set Point 2 (Ex. 400%). * Note 5 [3][CODE] S1 PLU FILE Enter Address Number (Ex. 3), save it. Return to S mode. Note 1: Unit Weight per 1000pcs is used to calculate the Quantity with place the product on the platter. There have two ways to enter Unit Weight value, by Numeric Key or by Weight Sampling. 1. Numeric Key Maximum 5 digits & 1 decimal point can be entered for Unit Weight. 2. Weight Sampling 1) Place the product on platter when Insufficient indicator ON. ①� Place the 10pcs of product on platter (Insufficient indicator lighted up) and then press [PIECES] key to do sampling. After a few seconds, a message "ADD 3" will appear on the display. If the samples are heavy enough, the insufficient indicator light will be off. ②� Add 3pcs of product on platter and press [PIECES] key. After a few seconds, the Unit Weight value will appear on Unit Weight column and Unit weight entering column. 2) Place the product on platter when Insufficient indicator OFF ①� Insufficient Indicator light will be OFF, if the weight exceeded the insufficient weight setting. Place the product on platter (Ex. 1kg =100pcs). ②� Enter the known Quantity (Ex. 100) and press [PIECES] key (If the Quantity is 10pcs, press [PIECES] key to sample without entering the Quantity). Wait for a while for Unit Weight computation to be completed. The Unit Weight value will appear on Unit Weight column and the Unit Weight entering column. Note 2: Maximum 1 line can be programmed for Part Name, Part No., Lot No. and location. The number of characters entry is depends on the Character Size entry or size of the print area. If selected label format without print area, maximum 1 line of 32 characters can be entered. Note 3: Maximum of 8 digits can be entered for Inventory and Threshold. Note 4: There have 4 types of Set Point can be select in this parameter. Refer to the following rotation for selecting Set Point type by pressing [+] key. % / QTY % / WEIGHT QTY / QTY WEIGHT / WEIGHT

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 23 of 65 Note 5: Up to 999% can be entered for Set Point 2. Set Point 2 must set according to Set Point 1 setting. For example: If Set Point 1 set to 9999999, the Set Point 2 cannot be set more than 100%. 3.3.2. Delete Item Code OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S1.0 ENTER ID CODE Enter Item Code programming mode. [1][2][3][A][B] S1.0 ENTER ID CODE Enter ID Code (Ex. 123AB). [-] S1.0 DEL ? Y-C N-T Enter delete mode. [C] S1 → ITEM CD [C] for Yes, [T] for No. Delete record, return to S mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 24 of 65 3.3.3. Label Format List Standard label format list is shown as below. LABEL FORMAT NO. FOR STANDARD LABEL SIZE (mm) 0 DEFAULT Label size set in specification setting 1 T1 60 X 28 2 T2 60 X 31 3 T3 60 X 34 4 T4 60 X 40 5 T5 60 X 43 6 T6 60 X 46 7 T7 60 X 49 8 T8 60 X 55 9 T9 60 X 37 10 T10 60 X 40 11 T11 60 X 43 12 T12 60 X 49 13 S 40 X 28 14 A 40 X 46 15 B 40 X 46 16 C 40 X 62.5 17 F1 * 18 F2 * 19 F3 * 20 F4 * 21 F5 * 22 F6 * 23 F7 * 24 F8 * 25~115 F9~F99 * Note: F1 to F99 are available only when free format is programmed.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 25 of 65 3.4. FACTORY NAME FILE Factory name is used for programming a short text describing the name of factory. Maximum 32 factory names can be programmed, each with 3 lines. The number of line depends on the character size. The default Factory Name print on label can be set in SPEC 56 & print centering of Factory Name on label can be select at SPEC 57. Note: Factory Name will not printed on the label if the selected label format without print area for Factory Name or SPEC 55 set to "0: NO PRINT". 3.4.1. Program Factory Name File At Programming Mode, select Factory Name programming mode and then enter new Factory Name No. (Ex. 1). OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [2] or [+] S2 FACTORY FILE Select Factory programming mode. [*] S2.0 0 NO SET Enter Factory programming mode. [1][*] S2.1 S01.01 S1 A 32 Enter Factory No. (Ex. 1). [D][I] … [E] S2.1 S01.10 S1 A 22 Enter Factory Name (Ex. DIGI STORE). [SHIFT UP][X] S2.1 S01.10 S2 A 22 Change font size to S2. (S1~S5; M1~M5) [CODE] S2 FACTORY FILE Store data, return to S mode. 3.4.2. Print Factory Name File The Factory Name report can be printed on receipt paper. A Full Report includes all programmed Factory Names and a Single Report includes one Factory Name data only. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S2.0 0 NO SET Enter Factory Name programming mode. [TARE] TEST2.0 1 ST NUM Enter Factory Name report print mode. [*] TEST2.0 32 EN NUM Enter start No. [*] S2.0 0 NO SET Enter end No. Print Factory Name Full report. [1] S2.0 1 NO SET Enter Factory No. (Ex. No.1). [TARE] S2.0 1 NO SET Print Factory Name Single report. Return to Factory Name programming mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 26 of 65 3.4.3. Delete Factory Name File OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S2.0 0 NO SET Enter Factory Name programming mode. [1] S2.0 1 NO SET Enter Factory No. (Ex. No.1). [-] S2.0 DEL ? Y-C N-T Enter delete mode. [C] S2 FACTORY FILE [C] for Yes, [T] for No. Delete record. Return to S mode. 3.5. PROGRAM DATE AND TIME The built-in clock system can automatically work once they are set. Date (Month/Day/Year): 2 digits for each part; Time (Hour/Minute): 2 digits for each part. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [4] or [+] three times S4 DATE AND TIME Select Date and Time programming mode. [*] S4.0 010100 MMDDYY Enter Date and Time programming mode. [0][8][1][9][0][4][*] S4.1 0000 HHMM Set Month 08, Day 19 and Year 04 (Ex. 2004-08-19). [9][0][0][*] S4 DATE AND TIME Set Hour 9, Minute 05. Store Date and Time. Return to S mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 27 of 65 3.6. ADDRESS FILE Address file is used to program factory address, which can be assigned in each Item and to be printed on the label. Since standard format does not have a print area set for Address, the Address cannot be printed when using these formats. To print Address on the label, a Free Format with an Address print area programmed must be used. Maximum 16 Address (No. 1 ~ 16) can be programmed with each up to 8 programmable lines. Number of line depends on the size of the print area or Character Size entry. 3.6.1. Program Address File OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [5] or [+] four times S5 ADDRESS FILE Select Address programming mode. [*] S5.0 0 NO SET Enter Address programming mode. [1][*] S5.1 P01.01 S1 A 32 Enter Address No. (Ex. 1). [S][H] … [I] S5.1 P01.08 S1 A 24 Enter Address (Ex. SHANGHAI). [SHIFT UP][X] S5.1 P01.10 S2 A 24 Change font size to S2. (S1~S5; M1~M5) [CODE] S5 ADDRESS FILE Store data, return to S mode. 3.6.2. Print Address File The Address report can be printed on receipt paper. A Full Report includes all programmed Address data and a Single Report includes one Address data only. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S5.0 0 NO SET Enter Address programming mode. [TARE] TEST5.0 1 ST NUM Enter Address report print mode. [*] TEST5.0 16 EN NUM Enter start No. [*] S5.0 0 NO SET Enter end No. Print Address Full report. [1] S5.0 1 NO SET Enter Address No. (Ex. No.1). [TARE] S5.0 1 NO SET Print Address Single report. Return to Address programming mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 28 of 65 3.6.3. Delete Address File OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S5.0 0 NO SET Enter Address programming mode. [1] S5.0 1 NO SET Enter Address No. (Ex. No.1). [-] S5.0 DEL ? Y-C N-T Enter Delete mode. [C] S5 ADDRESS FILE [C] for Yes, [T] for No. Delete record. Return to S mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 29 of 65 3.7. TEXT FILE Maximum 20 Texts are available (Text number 1~16 are for Item label and text number 17~20 are for Total label). Text is used for printing the fixed data on label such as “scale number” or “machine no”. Text cannot be printed when using standard format since they do not have any text print area set. A Free Format with a Text print area must be programmed. Maximum 2 lines per text can be programmed and number of line depends on the size of print area of the selected label format or the character size. 3.7.1. Program Text File OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [7] or [+] six times S7 TEXT FILE Select Text programming mode. [*] S7.0 0 NO SET Enter Text programming mode. [1][*] S7.1 T01.01 S1 A 100 Enter Text No. (Ex. 1). [Q][U] … [Y] S7.1 T01.08 S1 A 92 Enter Text data (Ex. QUANTITY). [SHIFT UP][X] S7.1 T01.10 S2 A 92 Change font size to S2. (S1~S5; M1~M5) [CODE] S7 TEXT FILE Store data, return to S mode. 3.7.2. Print Text File The Text report can be printed on receipt paper. A Full Report includes all programmed Text data and a Single Report includes one Text data only. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S7.0 0 NO SET Enter Text programming mode. [TARE] TEST7.0 1 NO SET Enter Text report print mode. [*] TEST7.0 20 EN NUM Enter start No. [TARE] S7.0 0 NO SET Print Text Full report. Return to Text programming mode. [1] S7.0 1 NO SET Enter Text No. (Ex. No.1). [TARE] S7.0 1 NO SET Print Text Single report. Return to Text programming mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 30 of 65 3.7.3. Delete Text File OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S7.0 TEXT 0 Enter Text programming mode. [1] S7.0 TEXT 1 Enter Text No. (Ex. No.1). [-] S7.0 DEL ? Y-C N-T Enter delete mode. [C] S7 TEXT FILE [C] for Yes, [T] for No. Delete record. Return to S mode. 3.8. FREE FORMAT FILE The Free Format enables you to design your own label format, by setting print angles, print positions, character size and other programmable items. You can create a new format by copying an existing label format and use it as a base or make a totally new label format. 3.8.1. General Information Label format within the following height and width can be created.  Up to 99 Free Formats can be stored in the memory, apart from the other 16 standard formats.  Standard format can be used as a basic format for creating a new format.  Print position of each item is programmed using "mm".  One Item label or one Total label is available for each Free Format number (F1~F99).  4 Print Angles can be set for all item data: 0, 90, 180 and 270 degrees.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 31 of 65 3.8.2 Print Area, Print Position and Print Angles The print position of each item is determined by setting the interval from "0" point (X=0, Y=0) to the base position of the programmed item. X and Y values need to be entered by "mm". Print Area The item data should not be printed within 1mm from the edge of the label as the following drawing shows.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 32 of 65 Print Position The printing position of each item data is decided by setting the distance from 0 point (X=0, Y=0) to the base position (X value, Y value). Print Angle Print angle of each Print Item can be selected from 4 different angles, 0 degree, 90 degree, 180 degree, and 270 degree. A whole format base or each Item Data-base may set print angle. According to the selected print angle, the status of print position differs as the following samples.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 33 of 65 3.8.3 Programming Parameter of Print Items Print Item for Item Label Up to 66 different item data can be programmed in Item Label Format. Item Data Type Item Data Type 1. ID CODE 5 42. ID CODE TITLE 1 2. GROSS WEIGHT 1 43. LOCATION TITLE 1 3. UNIT WEIHGT 1 44. PART NAME TITLE 1 4. NET WEIGHT 1 45. PART NUMBER TITLE 1 5. QUANTITY 1 46. LOT NUMBER TITLE 1 6. PACK DATE 1 47. NET WEIGHT TITLE 1 7. PACK TIME 1 48. GROSS WEIGHT TITLE 1 8. PART NUMBER 2 49. TARE TITLE 1 9. QUANTITY UNIT 1 50. UNIT WEIGHT BARCODE 3 10. PART NAME 2 51. TARE WEIGHT BARCODE 3 11. LOT NUMBER 2 52. QUANTITY BARCODE 3 12. ID CODE BARCODE 3 53. IMAGE 1 2 13. FACTORY 2 54. IMAGE 2 2 14. INVENTORY 1 55. IMAGE 3 2 15. THRESHOLD 1 56. IMAGE 4 2 16. LOGO 2 57. IMAGE 5 2 17. TARE WEIGHT 1 58. IMAGE 6 2 18. SCALE NUMBER 1 59. IMAGE 7 2 19. ADDRESS 2 60. IMAGE 8 2 20. LOCATION 2 61. IMAGE 9 2 21. SEQ NUMBER 1 62. IMAGE 10 2 22. STATUS 1 63. MULTI BARCODE 1 3 23. FRAME 1 4 64. MULTI BARCODE 2 2 24. FRAME 2 4 65. LOT NUMBER BARCODE 3 25 ~ 40. TEXT 1 ~ TEXT 16 2 66. PART NUMBER BARCODE 3 41. SEQ TITLE 1

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 34 of 65 Print Item for Total Label Up to 14 different item data can be programmed in Total Label Format. Item Data Type Item Data Type 1. TOTAL QUANTITY 1 9. TEXT 18 2 2. TOTAL QUANTITY UNIT 1 10. TEXT 19 2 3. UNIT WEIGHT 1 11. TEXT 20 2 4. PACK DATE 1 12. SEQ NUMBER 1 5. PACK TIME 1 13. SEQ TITLE 1 6. TOTAL TITLE 1 14. ACCUMULATE 1 7. TOTAL BARCODE 3 15. MULTI BARCODE 1 3 8. TEXT 17 2 16. MULTI BARCODE 2 2

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 35 of 65 Programmable Data Type Programmable data Type 1 Type 2 Type 3 Type 4 Type 5 X position YES YES YES YES YES Y position YES YES YES YES YES Angle YES YES YES NO YES Status YES YES YES YES YES Character Size YES NO NO NO YES Width NO YES NO NO YES Height NO YES YES NO YES Thickness NO NO NO YES NO 3.8.4 Free Format Entry At Programming Mode, select Free Format programming mode and then enter new Free Format number (Ex. 1) programming mode. *For edit, enter existing Free Format number. Basic Setting: (width, height, angle and label type) OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [8] or [+] seven times S8 FREE FORMAT Select Free Format programming mode. [*] S8.0 0 1 - 99 Enter Free Format setting programming mode. [1][*] S8.1 0 WT MM Enter the Free Format File No. (Ex.No.1). [4][8][*] S8.2 0 HT MM Enter Label print width (Ex.48mm). [3][5][*] S8.3 0 ANGLE Enter Label print height (Ex.35mm). [<<] or [>>] S8.3 90 ANGLE [<<] or [>>] key can change the selection of label angle. (0 / 90 / 180 / 270 degree) [*] S8.4 ITEM LABEL Label angle is turned 90 degree. [<<] or [>>] S8.4 TOTAL LABEL Select label type. (Item Label / Total Label) [*] S8.5 ← 1 F ITEM Enter item setting. Refer to Base Type 1 to 5 setting.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 36 of 65 Base Type 1: Item data in Data Base Type1 are Numeric data or Fixed data. The print position of item data can be programmed by setting X / Y value, Print angle and Character size. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Continued from the procedure Basic Setting: (width, height, angle and label type) S8.5 ← 2 F ITEM Item setting: Gross Weight [*] S8.5 0 X MM Enter item data programming mode. [1][*] S8.5 0 Y MM Enter X value (Ex.1mm). [1][*] S8.5 0 DG ANGLE Enter Y value (Ex.1mm). [>>][*] S8.5 0 STATUS Select print angle (Ex. 90 degree). [2][*] S8.5 S1 CHAR SIZE Enter print status (Ex. ALL PRINT). [>>] four times S8.5 S5 CHAR SIZE [<<] or [>>] key can change the selection of the character size. (S1~S5; M1~M5) [*] S8.5 ← 2 F ITEM Note 1: STATUS TYPE: 0 - NO PRINT 1 - WEIGH PRINT 2 - ALL PRINT Note 2: There are two ways to select the Item Data in Free Format programming by using different keys such as:  Enter the Item data number key.  Press [<<] key or [>>] key to search the Item data.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 37 of 65 Base Type 2 Item data in Base Type 2 are Alpha-numeric data. The print position of item data can be programmed by setting the max. print area , X / Y value, width of print area from X value, height of print area from Y value and print angle. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Continued from the procedure Basic Setting: (width, height, angle and label type) S8.5 ← 13 F ITEM Item setting: Factory. [*] S8.5 0 X MM Enter item data programming mode. [1][0][*] S8.5 0 Y MM Enter X value (Ex.10mm). [1][*] S8.5 0 DG ANGLE Enter Y value (Ex.1mm). [>>][>>][*] S8.5 0 WT MM Select print angle (Ex.180 degree). [2][0][*] S8.5 0 HT MM Enter width value. The width of Factory printing area is 20mm (Ex. 20mm). [1][5][*] S8.5 0 STATUS Enter height value. The height of Factory printing area is 15mm (Ex. 15mm). [2] S8.5 2 STATUS Enter print status (Ex. ALL PRINT). [*] S8.5 ← 13 F ITEM

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 38 of 65 Base Type 3 Item data in Data Base 3 is Barcode data. The print position of bar-code data can be programmed by setting X / Y value, width of Barcode from X value, height of Barcode from Y value and print angle. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Continued from the procedure Basic Setting: (width, height, angle and label type) S8.5 ← 12 F ITEM Item setting: Barcode. [*] S8.5 0 X MM Enter item data programming mode. [5][*] S8.5 0 Y MM Enter X value (Ex.5mm). [2][0][*] S8.5 0 DG ANGLE Enter Y value (Ex.20mm). [>>][*] S8.5 0 HT MM Select print angle (Ex.90 degree). [1][5][*] S8.5 0 STATUS Enter height value. The height of Barcode printing area is 15mm (Ex. 15mm). [2] S8.5 2 STATUS Enter print status (Ex. ALL PRINT). [*] S8.5 ← 12 F ITEM

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 39 of 65 Base Type 4 Item data in Data Base 4 is Frame data. The print position of Frame data may be programmed by setting X value, Y value, X1 value, Y1 value [the opposite point against the point (X,Y) on a diagonal line], and line weight. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Continued from the procedure Basic Setting: (width, height, angle and label type) S8.5 ← 23 F ITEM Item setting: Frame 1. [*] S8.5 0 X MM Enter item data programming mode. [1][0][*] S8.5 0 Y MM Enter X value (Ex.10mm). [1][*] S8.5 0 X1 MM Enter Y value (Ex.1mm). [2][0][*] S8.5 0 Y1 MM Enter X1 value. The X1 of Frame 1 printing area is 20mm (Ex. 20mm). [1][5][*] S8.5 0 STATUS Enter Y1 value. The Y1 of Frame 1 printing area is 15mm (Ex. 15mm). [2][*] S8.5 0 T MM Enter print status (Ex. ALL PRINT). [2] S8.5 2 T MM Enter thickness. The thickness of Frame 1 printing area is 2mm (Ex. 2mm). [*] S8.5 ← 23 F ITEM

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 40 of 65 Base Type 5 Item data in Base Type 5 are Alpha-numeric data. The print position of item data can be programmed by setting the max. print area , X / Y value, width of print area from X value, height of print area from Y value, print angle and character size. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Continued from the procedure Basic Setting: (width, height, angle and label type) S8.5 ← 1 F ITEM Item setting: ID Code. [*] S8.5 0 X MM Enter item data programming mode. [1][0][*] S8.5 0 Y MM Enter X value (Ex.10mm). [1][*] S8.5 0 DG ANGLE Enter Y value (Ex.1mm). [>>][>>][*] S8.5 0 WT MM Select print angle (Ex.180 degree). [2][0][*] S8.5 0 HT MM Enter width value. The width of ID Code printing area is 20mm (Ex. 20mm). [1][5][*] S8.5 0 STATUS Enter height value. The height of ID Code printing area is 15mm (Ex. 15mm). [2] S8.5 2 STATUS Enter print status (Ex. ALL PRINT). [*] S8.5 S1 CHAR SIZE The status of ID Code printing area is all item printing. [>>] four times S8.5 S5 CHAR SIZE [<<] or [>>] key can change the selection of the character size. (S1~S5; M1~M5) [*] S8.5 ← 1 F ITEM

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 41 of 65 3.8.5 Free Format Copy Function At Free Format programming mode, Select Copy existing Label Format and then select the existing label format want to be copy (Ex. T7) and go to next selection. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [8] or [+] seven times S8 FREE FORMAT Select Free Format programming mode. [*] S8.0 0 1 - 99 Enter Free Format setting programming mode. [1] S8.0 1 1 - 99 Enter the Free Format File No. (Ex. No.1). [+] S8.0 NO 0 COPY Press [+] key to enter free format copy function. [7] or [<<] and [>>] S8.0 T7 7 COPY Press [7] or [<<] and [>>] to select the existing label format to be copied (Ex. T7). [*][CODE] S8 FREE FORMAT Store the free format file 1, return to S mode. 3.8.6 Free Format Delete Function At Free Format programming mode, enter existing Free Format Number (Ex. 1) to be deleted. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S8.0 0 1 - 99 Enter Free Format programming mode. [1] S8.0 1 1 - 99 Enter free format file number 1. [-] S8.0 DEL ? Y-C N-T Enter delete mode. [C] S8 FREE FORMAT [C] for Yes, [T] for No. Delete free format file 1, return to S mode. Note 1: If want to cancel the deletion, press [PIECES] key to exit. Note 2: Non-existing Free Format File cannot be deleted.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 42 of 65 3.8.7 Sample of program a format by modifying the existing format Design a label format by copying an existing format and modifying it as need. Following is the example on how to customize standard format T1. E.g. Add the LOT NO. and remove the PART NAME from the standard Item Label Format OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [8] or [+] seven times S8 FREE FORMAT Select Free Format programming mode. [*] S8.0 0 1 - 99 Enter Free Format setting programming mode. [1] S8.0 1 1 - 99 Enter the Free Format File No. (Ex.No.1). [+] S8.0 NO 0 COPY Press [+] key to enter free format copy function. [1] S8.0 T1 1 COPY Press [1] to select the existing label format you want to be copy (Ex. T1). [*] S8.1 0 WT MM Enter the Free Format File No. (Ex.No.1). [5][6][*] S8.2 0 HT MM Enter Label print width.(Ex.56mm) [5][5][*] S8.3 0 ANGLE Enter Label print height.(Ex.55mm) [*] S8.4 ITEM LABEL Label angle is 0 degree. [*] S8.5 ← 1 F ITEM Enter item setting. Refer to Base Type 1 to 5 setting. [1][1] S8.5 ← 11 F ITEM Item setting: Lot No. [*] S8.5 0 X MM Enter item data programming mode. [1][*] S8.5 0 Y MM Enter X value (Ex.1mm). [2][7][*] S8.5 0 DG ANGLE Enter Y value (Ex.27mm). [*] S8.5 0 WT MM Select print angle (Ex.0 degree). [5][6][*] S8.5 0 HT MM Enter width value (Ex. 56mm). [5][*] S8.5 0 STATUS Enter height value (Ex. 5mm). [2] S8.5 2 STATUS Enter print status (Ex. ALL PRINT). [*] S8.5 S1 CHAR SIZE The status of ID Code printing area is all item printing.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 43 of 65 OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY [>>] four times S8.5 S5 CHAR SIZE [<<] or [>>] key can change the selection of the character size. (S1~S5; M1~M5) [*] S8.5 ← 11 F ITEM [1][0] S8.5 ← 10 F ITEM Item setting: Part Name. [*] S8.5 0 X MM Enter item data programming mode. [*] S8.5 0 Y MM Skip. [*] S8.5 0 DG ANGLE Skip. [*] S8.5 0 WT MM Skip. [*] S8.5 0 HT MM Skip. [*] S8.5 0 STATUS Skip. [0] S8.5 0 STATUS Enter print status (Ex. NO PRINT). [*] S8.5 S1 CHAR SIZE The status of Part Name printing area is NO PRINT. [*] S8.5 ← 10 F ITEM [CODE] S8 FREE FORMAT Save change, return to S mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 44 of 65 3.9 Logo File Logo is the trademark of the factory, which will be printed in Label. (When printing Logo data on Free Format Label, set the print area of Logo data on the Free Format in advance.) Logo data can be programmed up to 4 logos (Logo No. 1 ~ 4). A logo data is formed by a pattern of dots (128 horizontal dots and 64 vertical dots.) However, since the Label logo data is printed within the limits, which are programmed in label formats, program the logo data within the limits of print area on the format. Note: All standard formats have 37 dots x 30 dots for logo print area. 3.9.1 Pre-programming Logo Data 1) Prepare a section paper with 128 horizontal dots and 64 vertical dots. 2) When programming Label Logo, draw the limit of the Logo print area. 3) Draw the desired logo design in the section paper by filling the section with dot. (The dots are necessary to seize the image of the actual logo before programming.) Example: DIGI Logo for label (37 x 30 dots)

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 45 of 65 3.9.2 Program Display & Keys Function Program Display for Logo Set Up The following display appears when entering Logo Program Mode. DISPLAY Key Function for LOGO Set Up Key Function [0] Clear a dot. [1] Fill a dot. [<<] Move the cursor to left. [] [>>] Move the cursor to right. [] [W] Move the cursor to up. [] [X] Move the cursor to down. [] [*] Move up to the first dot in the next line. [CODE] Store the Data.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 46 of 65 3.9.3 Programming Order 1) After filling a section, programming status (the position of the cursor) moves to the next dot automatically. 2) When the programming status reached to the last dot (128 horizontal dots), or [*] key is depress, the programming status moves to the first left section on the next upper line automatically. 3.9.4 Program Logo File At Programming Mode, select Logo programming mode and enter new Logo number (Ex. 1). OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [9] or [+] eight times S9 LOGO FILE Select Logo programming mode. [*] S9.0 0 NO SET Enter Logo programming mode. [1][*] S9.1 0 X-POS Enter X position (Ex. 7 dots). [7][*] S9.2 0 Y-POS Enter Y position (Ex. 1 dot). [1][*] S9.3 000000 007-01 Set Fill or Clear dots you want and the save the setting and go to next upper line (Y 02) (Ex.11101110001). [1][1]……[0][1][*] S9.3 000000 001-02 Press [>>] key to move the cursor to next dot. Press [>>] key 6 times S9.3 000000 007-02 If necessary to change the position of the cursor been set, the following procedure is required. [-][-] S9.3 7 X-POS Change the Horizontal start position (Ex. 5 dots). [5][*] S9.3 2 Y-POS Change the Vertical start position (Ex. NO CHANGE). [*] S9.3 000000 005-02 After complete program Logo data, save it. [CODE] S9 LOGO FILE Store data, return to S mode. Note: If you want to exit without saving, press [PIECES] key follow by [C] key.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 47 of 65 3.9.5 Delete Logo File At Logo programming mode, enter existing Logo Number (Ex. 1) to be deleted. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S9.0 0 NO SET Enter Logo programming mode. [1] S9.0 1 NO SET Enter Logo File number 1. [-] S9.0 DEL ? Y-C N-T Enter delete mode. [C] S9 0 NO SET [C] for Yes, [T] for No. Delete Logo File 1, return to S mode. Note 1: If you want to cancel the deletion, press [PIECES] key to exit. Note 2: Non-existing Logo File cannot be deleted. 3.10 Memory Status The function is used for checking the number of existing PLU and remaining programmable PLU. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [1][0] or [+] nine times S10 MEMORY STATUS Select memory status check mode. [*] S10.0 P 6 LF 37980 [TARE] S10 MEMORY STATUS Return to S mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 48 of 65 3.11 Program Multi-barcode File At Programming Mode, select Multi-barcode programming mode and enter new Multi-barcode number (Ex. 1). 3.11.1. Program Multi-barcode File OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [1] [2] S12 MULTI- BARCODE Select Multi-barcode programming mode. [*] S12.0 0 NO SET Enter Multi-barcode programming mode. [1][*] S12.1 E_A M 0 [+] S12.1 M 0 Select Multi-barcode data type. [1][2][3][*] S12.2 E_B DEFAULT Enter barcode data. [+] S12.2 E_B EAN128 Select Multi-barcode type. [CODE] S12 MULTI- BARCODE Store data, return to S mode. 3.11.2. Delete Multi-barcode File OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S12.0 0 NO SET Enter Multi-barcode programming mode. [1] S12.0 1 NO SET Enter Multi-barcode No. (Ex. No.1). [-] S12.0 DEL ? Y-C N-T Enter delete mode. [C] S12 MULTI- BARCODE [C] for Yes, [T] for No. Delete record. Return to S mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 49 of 65 3.12. 2D BARCODE TEXT FILE Maximum 999999 2D Barcode Texts are available for 2D barcode. 3.12.1. Program 2D Barcode Text File OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY Press [MODE] key 3 times. S1 PLU FILE Enter S mode. Lamp S turns on. [1] [3] S13 2D BAR TEXT Select 2D BarcodeText programming mode. [*] S13.0 0 NO SET Enter 2D Barcode Text programming mode. [1][*] S13.1 T01.01 S1 A 100 Enter 2D Barcode Text No. (Ex. 1). [Q][U] … [Y] S13.1 T01.08 S1 A 92 Enter Text data (Ex. QUANTITY). [SHIFT UP][X] S13.1 T01.10 S2 A 92 Change font size to S2. (S1~S5; M1~M5) [CODE] S13 2D BAR TEXT Store data, return to S mode. 3.12.3. Delete 2D Barcode Text File OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY S13.0 0 NO SET Enter 2D Barcode Text programming mode. [1] S13.0 1 NO SET Enter 2D Barcode Text No. (Ex. No.1). [-] S13.0 DEL ? Y-C N-T Enter delete mode. [C] S13 2D BAR TEXT [C] for Yes, [T] for No. Delete record. Return to S mode.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 50 of 65 4. REGISTRATION MODE 4.1 ON/OFF 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Power on. [ON/OFF] STE70 VRxx.xx Stand-by-status. 0.0000kg 0 0 4.2 Reset and Weighing Check All weighing operations will be performed based on the procedure shown below. Operator should check this operation before any transactions. 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Reset the zero point. [REZERO] 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 0.0000kg 0 0 Place an item on the platter. (e.g. 1.kg) 1.0000kg 0 0 Remove the item from platter. 0.0000kg 0 0 4.3 Tare Subtraction 4.3.1 One touch Tare Subtraction 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Put tare (Ex. 30 g) on platter. 0.0300kg 0 0 Subtract the tare weight. [T] 0.0000kg 0 0 Remove the tare weight -0.0300kg 0 0 Clear the tare weight. [T] 0.0000kg 0 0

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 51 of 65 4.3.2 Digital tare Subtraction 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Key in the tare weight (Ex. 5g). [0][.][0][0][5][T] -0.0050kg 0 0 Clear the tare weight. [T] 0.0000kg 0 0 4.4 Item Call Up 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Enter the ID Code (Ex. 123AB). [1][2][3][A][B] 0.0000kg 0 0 Call up. [CODE] 0.0000kg 0.1000 0 Return to stand-by-status. [C] 0.0000kg 0 0 4.5 Set New Item Code in Registration Mode This function is used to program a New ITEM in Operation Mode and update to ITEM Files. To enable this function, SPEC 4 must set to "0" in advance. 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Enter new ID Code (Ex. 123). [1][2][3] 0.0000kg 0 0 Press [CODE] key to store the New Item in Item Files. [CODE] NEW ITEM SET Enter unit weight (Ex. 1.0000). [1] [UNIT WEIGHT] 0.0000kg 1.0000 0 Update new Unit Weight to the item 123. [UNIT WEIGHT] 0.0000kg 1.0000 0 Return to the stand-by-status. [C] 0.0000kg 0 0 Call up item 123. [1][2][3] [CODE] 0.0000kg 1.0000 0 Note: If you want set new tare value and update to item, after set the tare value and then press [UNIT WEIGHT] key to store.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 52 of 65 4.6 Manual Print 4.6.1 Item Label Printing 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Call up item 123. [1][2][3] [CODE] 0.0000kg 1.0000 0 Place the product on the platter (Ex. 0.5kg). 0.5000kg 1.0000 500 Issue label or receipt. * Note. [*] 0.5000kg 1.0000 500 Note: When the previous label remains at the Dispenser, a message “PLEASE PEEL LABEL” appears when press [*] key. If want to print out next label without removing the previous label, SPEC 48 must set to 0 “DISABLE” in advance. 4.6.2 Total Label Printing 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Call up item 123. [1][2][3] [CODE] 0.0000kg 1.0000 0 Place the product on the platter (Ex. 0.5kg). 0.5000kg 1.0000 500 Accumulate. [+] TOTAL 500 Issue label or receipt. Return from Total mode. * Note. [*] 0.5000kg 1.0000 500 Note: In Label Mode, label print when press [+] or [-] key can be select at SPEC 34.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 53 of 65 4.7 Accumulation and Subtraction There are two ways for individual product to issue total label or receipt. 1. Place the product on the platter. 2. Enter the known quantity of the product. 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Call up item 123. [1][2][3] [CODE] 0.0000kg 1.0000 0 Enter the known Quantity for the product (Ex. 1000Pcs) for accumulation. * Note 1. [1][0][0][0][+] TOTAL 1000 Exit from Total Mode. * Note 2. [C] 0.0000kg 0 0 Place the product on the platter (Ex. 0.5kg). 0.5000kg 1.0000 500 Accumulate. [+] TOTAL 1500 Exit from Total Mode. [C] 0.5000kg 1.0000 500 Enter the known Quantity for the product (Ex. 700Pcs) for subtraction. [7][0][0][-] TOTAL 800 Issue label or receipt. Return from Total mode. [*] 0.5000kg 1.0000 500 Remove the product from platter and then press [C] key to clear the Item. [C] 0.0000kg 0 0 Note 1: Max. 9999999 can be entered. Note 2: Auto exit from Total Mode can be selected using SPEC 14.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 54 of 65 4.8 Unit Weight Operation 4.8.1 Unit Weight Setting in Operation Mode User can set new unit weight by sampling the product or enter the known unit weight by numeric keys. 4.8.1.1 By Sampling 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Place the product on the platter (Ex. 0.1kg). * Note 1. 0.1000kg 0 0 Enter the product quantity (Ex. 50pcs). * Note 2. [5][0] 0.1000kg 0 0 Press [PIECES] key to sample. * Note 3. [PIECES] 0.1000kg 2.0001 50 Note 1: When the samples are placed on the platter, add few more samples if the Insufficient lamp is "ON" until Insufficient lamp is "OFF". Then enter the samples quantity by numeric key and press [PIECES] key. Note 2: For product quantity of 10pcs, skip this step. Note 3: Display Accuracy Unit Weight calculation during re-computing, can be set at SPEC 9. 4.8.1.2 By Numeric Key 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Place the product on the platter (Ex. 0.1kg). 0.1000kg 0 0 Enter the known Unit Weight by numeric key (Ex. 20). [2][0] 0.1000kg 0 0 Press [UNIT WEIGHT] key. [UNIT WEIGHT] 0.1000kg 20.000 5

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 55 of 65 4.8.2 Re-computing Unit Weight in Memory This function is used to set new Unit Weight by sampling and update to Item File in Counting Mode. 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Call up item 1. [1] [CODE] 0.0000kg 1.0000 0 Place the product on the platter until the indicator of RECOMPUTING light up (Ex.0.1kg). 0.1000kg 1.0000 100 Press [PIECES] key to Re- computing. * Note 1. [PIECES] 0.1000kg 1.0002 100 Press [UNIT WEIGHT] key to update new Unit Weight to Item File. * Note 2. [UNIT WEIGHT] 0.1000kg 1.0002 100 Remove the product from platter and then press [C] key to clear the Item. [C] 0.0000kg 0 0 Recall up the item 1. [1][CODE] 0.0000kg 1.0002 0 Note 1: Display Accuracy Unit Weight calculation during re-computing, can be set at SPEC 9. Note 2: SPEC 4 “SET TO NEW ITEM”, must be set to 0: Yes, to be able to save Unit Weight.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 56 of 65 4.9 Inventory Operation This function is used to store the product quantity IN or OUT in Item File. Inventory operation only available after calling up an Item and then by pressing [SHIFT DOWN][I] or [SHIFT DOWN][J] key for IN or OUT Inventory respectively. There are two ways to store the Quantity data to Inventory file of the item, Manual Transaction and Total Transaction of the Individual Item only. (Inventory Operation is not available for Multiple Items Transaction). 4.9.1 Manual Transaction 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Call up item 1. [1] [CODE] 0.0000kg 1.0000 0 Press [SHIFT DOWN] [I] key to select Inventory IN. * Note 1. [SHIFT DOWN] [I] 0.0000kg 1.0000 0 Place the product on the platter (Ex.0.1kg). 0.1000kg 1.0000 100 Store the Quantity into the item Inventory IN. * Note 2. [*] 0.1000kg 1.0000 100 Remove the product from platter and then press [C] key to clear the Item. [C] 0.0000kg 0 0 Note 1: Press [SHIFT DOWN] [I] key for Inventory In and press [SHIFT DOWN] [H] key to clear Inventory operation, Note 2: In order to save the Quantity into the Item Inventory, SPEC 4 “SET TO NEW ITEM” must be set to 0: YES.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 57 of 65 4.9.2 Total Transaction 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Call up item 1. [1] [CODE] 0.0000kg 1.0000 0 Press [SHIFT DOWN] [J] key to select Inventory OUT. * Note. [SHIFT DOWN] [J] 0.0000kg 1.0000 0 Place the product on the platter (Ex.0.1kg). 0.1000kg 1.0000 100 Accumulate. [+] TOTAL 100 Exit from Total Mode. [C] 0.1000kg 1.0000 100 Enter known quantity (Ex. 500Pcs) by numeric key and press [+] key. [5][0][0][+] TOTAL 600 Store the Quantity to Inventory OUT. [*] 0.1000kg 1.0000 100 Remove the product from platter and press [C] key to clear the Item. [C] 0.0000kg 0 0 Note: Press [SHIFT DOWN] [I] key for Inventory In and press [SHIFT DOWN] [H] key to clear Inventory operation,

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 58 of 65 4.10 Function key 4.10.1 Net/Gross Key Gross weight displays are available in Registration Mode by press [SHIFT DOWN] + [M] key to enter Gross Mode. Note: To enable this operation, SPEC 643 must set to "0" in advance. 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Put 300g weight on platter. 0.3000kg 0 0 Subtract the tare weight. [T] 0.0000kg 0 0 Put another 500g weight on platter. 0.5000kg 0 0 Enter GROSS mode. [SHIFT DOWN] [M] 0.8000kg GROSS WEIGHT Return to NET mode. [SHIFT DOWN] [M] 0.5000kg 0 0 Remove all weight from platter and clear the tare value. [T] 0.0000kg 0 0 4.10.2 Switch Platform Key Switching platform is available in Operation Mode by pressing the [SCALE] key to switch between Scale 1 and Scale 2. 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 9 – SCALE 1 10 – SCALE2 OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 9 10 Stand-by-status. 0.0000kg 0 0 Call up item 1. [1][CODE] 0.0000kg 1.0000 0 Press [SCALE] key to change scale form scale 1 to scale 2. [SCALE] 0.0000kg 1.0000 0 Note: Weight Decimal Point position for Scale B depends on SPEC 610 setting.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 59 of 65 4.10.3 Switch Weight Unit Key This function is used to change the Weight Unit between kg and lb in Operation Mode. The default weight unit is set using SPEC 600. To enable this function, SPEC 642 (Kg/Lb Inhibit) must be set to 0: NO in advance. 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Put 0.1kg weight on platter. 0.1000kg 0 0 Change weight unit from kg to lb. [SHIFT DOWN] [N] 0.2204lb 0 0 Change weight unit from lb to kg. [SHIFT DOWN] [N] 0.1000kg 0 0 4.10.4 View Item Key The following view keys list enables user to view the items data in operation mode. Key Operation Remark [SHIFT DOWN][A] To view the ID CODE. [SHIFT DOWN][B] To view the PART NAME. [SHIFT DOWN][C] To view the PART NUMBER. [SHIFT DOWN][D] To view the LOCATION. [SHIFT DOWN][E] To view the INVENTOTY. [SHIFT DOWN][F] To view the THRESHOLD. [SHIFT DOWN][G] To view the SET-POINT DATA. (Set point 1 and Set point 2)

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 60 of 65 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Call up item 1. [1][CODE] 0.0000kg 1.0000 0 To view ID Code. [SHIFT DOWN][A] 0.0000kg 1.0000 0 To view Part Name. [SHIFT DOWN][B] 0.0000kg 1.0000 0 To view Part Number. [SHIFT DOWN][C] 0.0000kg 1.0000 0 To view Location. [SHIFT DOWN][D] 0.0000kg 1.0000 0 To view Inventory quantity. [SHIFT DOWN][E] 0.0000kg 1.0000 0 To view Threshold. [SHIFT DOWN][F] 0.0000kg 1.0000 0 To view Set Point 1. [SHIFT DOWN][G] 0.0000kg 1.0000 0 Press [<<] or [>>] key to view Set Point 2 [>>] 0.0000kg 1.0000 0 Press [C] key to clear the Item. [C] 0.0000kg 0 0 4.10.5 Address No Key 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Call up item 1. [1][CODE] 0.0000kg 1.0000 0 To change the address Number for temporary print on label. [SHIFT DOWN] [L] 0.0000kg 1.0000 0 Enter new Addr No (Ex. 9) and press [*] to store. * Note. [9][*] 0.0000kg 1.0000 0 Place the product on platter (Ex. 0.1kg) and press [*] key. [*] 0.1000kg 1.0000 100 Remove the product from platter and press [C] key to clear the Item. [C] 0.0000kg 0 0 Note: Press [C] key to Exit.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 61 of 65 4.10.6 Lot No Key This Function is for User to set and save new Lot No in Registration Mode and also can be used for all items when called up the item and press [LOT NO] key. To use this function, the SPEC 12 (KEEP LOT NO IN REGISTRATION MODE) must set to 0: ALLOW in advance. 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Call up item 1. [1][CODE] 0.0000kg 1.0000 0 Press [LOT NO] key. * Note. [LOT NO] 0.0000kg 1.0000 0 Enter new Lot No (Ex. 234). [2][3][4] 0.0000kg 1.0000 0 Place the product on platter (Ex. 0.1kg) and press [*] key. [*] 0.1000kg 1.0000 100 Remove the product from platter and press [C] key to clear the Item. [C] 0.0000kg 0 0 Note: If want to print original Item and Lot No on label, place the product on platter and press [*] key. 4.10.7 Sequence No. Key This function is to allow the user to set and save new Sequence No. in Registration Mode. 1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 - ∑ 7 - IN 8 - OUT OPERATION KEYS WEIGHT UNIT WEIGHT QUANTITY 1 2 3 4 5 6 7 8 Stand-by-status. 0.0000kg 0 0 Press [SHIFT DOWN][K] key. [SHIFT DOWN] [K] 0.0000kg 0 0 Enter new Sequence No (Ex. 234). * Note. [2][3][4][*] 0.0000kg 0 0 Note: Press [C] twice to exit.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 62 of 65 5. Report Mode 5.1. Report Type Selection The DC-400 has report function to print out various kinds of transaction reports for analysis and checking. The types of reports are as shown in the table below. Report Type Contents ITEM REPORT Print item data programmed. INVENTORY REPORT Print item inventory data and item in/out count. SHELF LOCATION PRINT Print shelf location label. 5.2. Report Mode Entry OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY 0.0000kg 0 0 R mode. [MODE] [MODE] X1 ITEM REPORT Enter X mode. [+] X2 INVENT REPORT Press [+] key to select next report. [+] X3 SHELF LOCATION Press [+] key to select next report. Press [MODE] key 4 times. 0.0000kg 0 0 Return to R mode 5.3. Item Report The item report can be printed on receipt paper. All Item Report or One Item Report can be selected to print. 5.3.1 One Item Print OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY X1.0 ITEM REPORT Enter X mode. [*] X1.1 ONE ITEM PRINT Enter Item Report mode. [*] X1.2 NO SET Enter One Item Print mode. [1][2][3] X1.2 NO SET Enter the existing Item Code for One Item Report printing (Ex. 123). [*] X1.0 ITEM REPORT Print One Item Report.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 63 of 65 5.3.2 All Item Print OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY X1.0 ITEM REPORT Enter X mode. [*] X1.1 ONE ITEM PRINT Enter Item Report mode. [+] X1.1 ALL ITEM PRINT Select All Item Print. [*] X1.1 PRINT ALL ITEM Print All Item Report. * Note. Note: To stop printing, press [FEED] key.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 64 of 65 5.4. Inventory Report On Inventory Report, there have three report can be select in this mode, Threshold Print, IN and OUT Count Print and Clear IN and OUT count file. The report will print on receipt paper. 5.4.1 Print Threshold Report Threshold Report is to shows under-stocked or over-stocked items at various levels by presetting the optimal stock levels. This prevents stock outs and keeps optimum inventory balance. Threshold report can be printed, by entering the stock level percentage. The formula for Stock Level is shown as follows: Stock Level (%) = [(Inventory - Threshold) / Threshold] x 100 Note: Only the items Stock level equal or below the entering percentage will printed on the report. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY X2.0 INVENTORY REPORT Enter X mode. [*] X2.1 THRESHOLD Enter Threshold Report mode. [*] X2.2 0.00 STOCK % Enter stock level (%) mode. [-][2][0][0][0] X2.2 -20.00 STOCK % Enter the percentage of the stock level (Ex. - 20.00%). [*] X2.0 INVENTORY REPORT Print Threshold Report. * Note. Note: To stop printing, press [FEED] key. 5.4.2 Print In / Out Count Report OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY X2.0 INVENTORY REPORT Enter X mode. [*] X2.1 THRESHOLD Enter Threshold Report mode. [+] X2.1 IN/OUT PRINT Select In/Out Count Report. [*] X2.0 INVENTORY REPORT Print In/Out Count Report. * Note. Note: To stop printing, press [FEED] key.

DC-400 Operation Manual

Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD. 65 of 65 5.4.3 Clear In / Out Count Report OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY X2.0 INVENTORY REPORT Enter X mode. [*] X2.1 THRESHOLD Enter Threshold Report mode. [+][+] X2.1 CLEAR IN/OUT Select clear In/Out Count Report. [*] X2.2 CLEAR DAILY Enter select reset type mode. [+][+] X2.2 CLEAR ALL Select clear all In/Out Count Report. [*] X2.0 INVENTORY REPORT Clear all In/Out Count Report. 5.5. SHELF LOCATION PRINT This section is used to select shipping label format of the item for shipment. If standard format does not have the print area for programmed shipping data, it is required to use a free format with the print area for programmed shipping data. OPERATION DISPLAY REMARK WEIGHT UNIT WEIGHT QUANTITY X3.0 SHELF LOCATION Enter X mode. [*] X3.1 NO SET Enter Shelf Location Print mode. [1][2][A][*] X3.2 DEF 0 LAB FR1 Enter ID Code (Ex. 12A). [<<] or [>>] X3.1 LAB FR T6 6 Select Label format by press [<<] or [>>] key. [*] X3.0 SHELF LOCATION Print Shelf Location label.

Other Scales Manuals