1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746

© Copyright 2003. Black Box Corporation. All rights reserved.

AUI to BNC Transceiver

CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: [email protected]

FCC AND IC STATEMENTS

FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio- frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada.

AUI TO BNC TRANSCEIVER

FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS (continued) Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.

TRADEMARKS USED IN THIS MANUAL

TRADEMARKS USED IN THIS MANUAL Any trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.

AUI TO BNC TRANSCEIVER

Contents Chapter Page 1. Specifications . . . . . . . . . . . . . . . . . . 5 2. Introduction . . . . . . . . . . . . . . . . . . . 7 2.1 Description. . . . . . . . . . . . . . . . . 7 2.2 What the Package Includes. . . . 7 2.3 Features . . . . . . . . . . . . . . . . . . . 8 3. Installation. . . . . . . . . . . . . . . . . . . . 10 3.1 Disabling SQE Test . . . . . . . . . 10 3.2 Installing the Transceiver . . . . 11 4. Troubleshooting . . . . . . . . . . . . . . . 13 4.1 Calling Black Box . . . . . . . . . . 13 4.2 Shipping and Packaging . . . . . 14 Appendix. AUI (DB15) Connector Pinout. . . . . . . . . . . . . . . . . . . . 15

CHAPTER 1: Specifications

1. Specifications Standards: IEEE 802.3 User Controls: SQE switch Maximum Coaxial Cable Segment Distance: Up to 606.8 ft. (185 m) Speed: 10 Mbps Connectors: (1) DB15 AUI M, (1) BNC F Indicators: LEDs: (1) Power, (1) SQE Temperature Tolerance: Operating: 32 to 122°F (0 to 50°C); Storage: -40 to +212°F (-40 to +100°C) Relative Humidity: Operating: 8 to 80%, noncondensing; Storage: 5 to 98%, noncondensing

AUI TO BNC TRANSCEIVER

Power: From the AUI interface Size: 0.8"H x 1.6"W x 3.8"D (2 x 4.1 x 9.7 cm) Weight: 0.2 lb. (<0.1 kg)

CHAPTER 2: Introduction

2. Introduction 2.1 Description The AUI to BNC Transceiver lets you connect an Ethernet device (such as a LAN card installed in a PC, or a bridge, router, hub, or repeater) to thin Ethernet coaxial cable. It connects either directly to the AUI port on the Ethernet device or via a standard AUI cable. The transceiver complies with IEEE 802.3 transceiver specifications. 2.2 What the Package Includes Your package should include the following items: • (1) AUI to BNC Transceiver

AUI TO BNC TRANSCEIVER

• (1) BNC T-connector • This users’ manual If anything is missing or damaged, please contact Black Box at 724-746-5500. 2.3 Features • Provides a complete AUI to thin Ethernet (10BASE2) interface, including transmit, receive, collision, and jabber functions, and SQE (signal quality error) test. • Supports message traffic at a data rate of 10 Mbps. • Extends a coaxial cable segment up to 606.8 feet (185 m) without a repeater.

CHAPTER 2: Introduction

• Supports system configurations using the CSMA/CD access mechanism defined in the IEEE Local Area Network specifications.

AUI TO BNC TRANSCEIVER

3. Installation 3.1 Disabling SQE Test When the transceiver is attached to a LAN card, bridge, or router, the SQE switch (located on the bottom of the transceiver) should be ON. When the transceiver is attached to a hub or repeater, the SQE switch should be OFF. NOTE The transceiver is shipped from the factory with the SQE (heartbeat) test enabled (ON).

3.2 Installing the Transceiver

1. Turn the power to the network device off. 2. Connect a BNC T-connector to the transceiver’s BNC female connector, then connect thin coax cable to the T-connector. If only one end of the T-connector is connected, install a 50-ohm BNC terminator on the other end. 3. Use a standard AUI cable (50 ft. [15.2 m] long) to connect an Ethernet device to the transceiver’s DB15 AUI connector, or directly mount the transceiver to a DTE. 4. Turn the power to the network device back on. Verify that the Power LED on the transceiver is on. CHAPTER 3: Installation

AUI TO BNC TRANSCEIVER

Once the transceiver is installed, it operates automatically in half-duplex mode. When the SQE LED lights, a collision is detected on the AUI port.

4.1 Calling Black Box

If you determine that your AUI to BNC Transceiver is malfunctioning, do not attempt to alter or repair the unit. It contains no user-serviceable parts. Contact Black Box at 724-746-5500. Before you do, make a record of the history of the problem. We will be able to provide more efficient and accurate assistance if you have a complete description, including: • the nature and duration of the problem. • when the problem occurs. CHAPTER 4: Troubleshooting

AUI TO BNC TRANSCEIVER

• the components involved in the problem. • any particular application that, when used, appears to create the problem or make it worse. 4.2 Shipping and Packaging If you need to transport or ship your AUI to BNC Transceiver: • Package it carefully. We recommend that you use the original container. • If you are shipping the transceiver for repair, make sure you include everything that came in the original package. Before you ship, contact Black Box to get a Return Authorization (RA) number.

APPENDIX: AUI (DB15) Connector Pinout

Appendix. AUI (DB15) Connector Pinout Pin Symbol Name/Function 1 CI-S Control-In Shield: The shield for the CI twisted pair in the AUI cable. 2 CI-A Control-In Circuit A: The positive signal for the CI circuit. With CI-B, CI-A is an output current driver pair to the CI circuit. This output pair is activated when a collision is detected on the network, either during self-test (heartbeat) as the SQE test sequence or after the watchdog timer has expired to indicate that the transmitter is disabled.

AUI TO BNC TRANSCEIVER

Pin Symbol Name/Function 3 DO-A Data-Out Circuit A: The positive signal for the DO circuit. With DO-B, DO-A is a differential receiver input pair from the DO circuit. This input pair receives 10-Mbps Manchester- encoded data from the AUI transceiver cable, which is driven by the DTE (terminal or computer). 4 DI-S Data-In Shield: The shield for the DI twisted pair in the AUI cable. 5 DI-A Data-In Circuit A: The positive signal for the DI circuit. With DI-B, DI-A is an output current driver pair to the DI circuit. This output pair drives the AUI transceiver cable with 10-Mbps Manchester-encoded data received from the coaxial cable wire of the network. 6 VC Voltage Common 7 NC Not Connected 8 NC Not Connected

APPENDIX: AUI (DB15) Connector Pinout

Pin Symbol Name/Function 9 CI-B Control-In Circuit B: The negative signal for the CI circuit. With CI-A, CI-B is an output current driver pair to the CI circuit. This output pair is activated when a collision is detected on the network, either during self-test (heartbeat) as the SQE test sequence or after the watchdog timer has expired to indicate that the transmitter is disabled. 10 DO-B Data-Out Circuit B: The negative signal for the DO circuit. With DO-A, DO-B is a differential receiver input pair from the DO circuit. This input pair receives 10-Mbps Manchester- encoded data that is driven by the DTE (terminal or computer). 11 DO-S Data-Out Shield: The shield for the DO twisted pair in the AUI cable.

AUI TO BNC TRANSCEIVER

Pin Symbol Name/Function 12 DI-B Data-In Circuit B: The negative signal for the DI circuit. With DI-A, DI-B is an output current driver pair to the DI circuit. This output pair drives the AUI transceiver cable with 10-Mbps Manchester-encoded data received from the coaxial cable wire of the network. 13 VP Voltage Plus: The power supply to the transceiver. 14 VS Voltage Shield 15 NC Not Connected Shell PG Protective Ground: Chassis ground from the DTE. This circuit is connected to the outer shell of the transceiver.