ELTEX STATICJET RX22 Operating Instructions Manual

Text of the manual

RX22 Ion Blower Unit

with integrated High Voltage Generator BA-en-2083-1909 F00062y

List of contents

1 Outline of appliance RX22 Ion Blower Unit STATICJET . . . . . . 7 2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1 Identification of risks and hazards . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.2 Contact protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.3 Technical advance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.4 Proper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.5 Work and operational safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3 Installation and assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3.1 Assembling the RX21 Ion Blower Unit STATICJET . . . . . . . . . . . 11 3.2 Ground connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.3 Connecting the air hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.4 Connecting the supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.5 Fault signal connection and external control . . . . . . . . . . . . . . . . . 13 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4.1 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4.2 Function monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 6 Trouble shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 7 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 8 Technical specifications RX22 STATICJET . . . . . . . . . . . . . . . 19 9 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 10 Spare parts and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

The RX22 Ion Blower Unit STATICJET are used mainly in cases where

disruptive static charges on material webs impair production processes and need to be eliminated. The air current carries the ions generated at the emission tip through the nozzle to the object to be discharged. The RX22 Ion Blower Unit STATICJET features the following charac- teristics: • integrated high voltage generation, no internal high voltage wiring required • short-circuit proof • 24 V DC supply voltage • compact design, small dimensions and weight • adaptable and easy to install • three different nozzle designs • To monitor the proper function of the unit, the RX22 ion blower unit STATICJET is equipped with two LEDs which display normal operation or faults. If a fault is detected, the integrated circuit will switch off the high voltage and generate a fault signal. • Contact to the external control Please read the operating instructions carefully before starting the instru- ment. This will help you prevent personal injuries and damage to property. Please give us a call if you have any suggestions, proposals or ideas for improvements. We greatly appreciate the feedback from the users of our appliances.

Outline of appliance RX22 Ion Blower Unit

STATICJET 1 Enclosure with integrated high voltage generator 2 Combined socket contact: supply voltage and fault signal contact 3 Grounding connection 4 Connection for compressed air supply 5 LED red, fault signal 6 LED green, high voltage OK 7.1 Nozzle attachment: circular nozzle RX22/S 7.2 Nozzle attachment: fishtail nozzle RX22/F 7.3 Nozzel attachment: flexible hose RX22/P (length 300 mm) 8 4 x attachment bore holes M4; max. screw-in depth 5 mm Fig. 1: RX22 Ion Blower Unit STATICJET with integrated high voltage generator Z-116821y ��� ��� ��� � �� � � � �

The units have been designed, built and tested using state-of-the-art engi-

neering, and have left the factory in a technically and operationally safe condition. If used improperly, the units may nevertheless be hazardous to personnel and may cause injury or damage. Read the operating instruc- tions carefully and observe the safety instructions. 2.1 Identification of risks and hazards Possible risks and hazards resulting from the use of the units are referred to in these operating instructions by the following symbols: Warning! This symbol appearing in the operating instructions refers to operations which, if carried out improperly, may result in serious personal injuries. Caution! This symbol appearing in the operating instructions refers to operations which, if carried out improperly, may result in damage to property. 2.2 Contact protection As the site of installation and/or use of the units is outside the control of Eltex, contact protection against inadvertent contact of the emission tip by personnel as specified by the employers’ liability insurance association have to be provided (e.g. DGUV V3 in Germany). Contact protection made of conductive material must professionally be grounded. 2.3 Technical advance The manufacturer reserves the right to make changes to the technical specifications without prior notice in order to adapt the units to state-of- the-art engineering. Eltex will provide the latest information on any changes or modifications in the operating instructions on request. 2.4 Proper use The RX22 Ion Blower Unit STATICJET must be used only for discharging static charges from material surfaces. Other uses are not permitted. The manufacturers will not assume any liability and warranty if the units are used improperly or outside the intended purpose. Modifications or changes made to the power supplies are not permitted. Use only original Eltex spare parts and equipment.

Work and operational safety

Warning! Carefully observe the following notes and the complete chapter 2 "Safety”, page 8! • Before carrying out repairs, cleaning or maintenance work and before resetting after malfunctions, switch off the unit and disconnect the mains supply voltage (see chapter 5 "Maintenance”, page 15, chapter 6 "Trouble shooting”, page 17). • Any work involving the units must be carried out by qualified electri- cians (see chapter 5 "Maintenance”, page 15, chapter 6 "Trouble shoo- ting”, page 17). • Before carrying out any work involving the units, the machine which has the RX22 ion blower unit STATICJET fitted must not be in operation (see chapter 5 "Maintenance”, page 15). • A permanent ground contact must be made via the grounding connec- tion (3, Fig. 1). The ground cable should have a minimum cross section of 1.5 mm² (see chapter 3.2 "Ground connection”, page 12). • A 24 VDC line current, designed for a min. current of 120 mA per unit, is required for operating the RX22 ion blower unit STATICJET (see chap- ter 3.4 "Connecting the supply voltage”, page 12, chapter 4 "Opera- tion”, page 14). • Before starting up the ion blower unit the user must make sure that the unit has been installed and assembled correctly. Then first activate the air and then the supply voltage (see chapter 4.1 "Startup”, page 14). • The maximum rated pressure is 0.2 MPa (see chapter 3.3 "Connecting the air hose”, page 12). • The internal emission tip of the RX22 ion blower unit STATICJET must not be damaged. For trouble-free operation, the tip must be straight and sharply pointed (see chapter 5 "Maintenance”, page 15). • Check the units at regular intervals and before startup for any damage. Any damaged components must be repaired or replaced before conti- nuing to operate the unit, or the units must be disabled. • Make sure that the units are clean at all times. Dirt results in malfunctions and in premature wear of the units. Do not immerse the RX22 ion blower unit STATICJET in solvent. Allow the solvent to evaporate completely before restarting the RX22 ion blower unit STATICJET (see chapter 5 "Maintenance”, page 15). • The operation of the RX22 ion blower units STATICJET can generate ozone. The ozone concentration levels developing near the units depend on many diffe-rent factors such as site of installation, air circu- lation, etc., and can therefore not be specified in general terms. If the maximum allowable concentration of ozone must be observed at

the site of installation of the bar, the concentration must be measured

on site by the operator. The AGW value (maximum admissible concentration) serves to assess the ozone concentration at the workplace. The user must make sure that the appropriate national AGW value is at no times exceeded, e.g. in Germany the ozone concentration occurring during the operation of the system must not exceed the recommended value based on interna- tional limits of 0.06 ml/m³ (0.12 mg/m³). • Mechanical or electrical modifications of the RX22 ion blower units STAITCJET are not permitted. • Depending on the air pressure selected, flow noise developing during the operation of the RX22 ion blower unit STATICJET may generate noise emission levels > 85 dB (A); the appropriate PSA (personal pro- tective equipment / hearing protection) should be provided; for further details, see chapter 8 "Technical specifications RX22 STATICJET”, page 19.

Installation and assembly

3.1 Assembling the RX22 Ion Blower Unit STATICJET The terminals of the ion blower unit must be freely accessible at all times and the display LEDs must be visible. 2 x M4 threaded holes each are provided on either side of the enclosure to mount the RX22 ion blower unit STATICJET. The maximum screw-in depth is 5 mm (assembly dimensions, see Fig. 2). Fig. 2: Installation dimen- sions, RX22 Ion Blower Unit STATICJET Z-116818y �������� �� �� �� �� �� �� �� �� ���

A permanent ground contact must be made via the grounding connection

(3, Fig. 1). The ground cable should have a minimum cross section of 1.5 mm². 3.3 Connecting the air hose Caution! The RX22 ion blower unit STATICJET is fitted with a plug-type connector for outside tolerated compressed air hoses with  8 mm. The maximum rated pressure is 0.2 MPa. If necessary, use a pressure regulator, air filter, oil and water separator. 3.4 Connecting the supply voltage Caution! A 24 VDC line current, designed for a min. current of 120 mA per unit, is required for operating the RX22 ion blower unit STATICJET. Supply voltage is to be provided by the customer and connected via the plug supplied with the unit, see Fig. 4. Alternatively, the power supply available as accessory may be used. To ensure that no high voltage is generated when the material web is at rest, we recommend releasing the high voltage via the remote contact. If the material web is at rest, or if the machine is not in operation, no high voltage will then apply. Fig. 3: Unit connection side Z-116819y_1 1 combined socket contact 24 V DC and fault signal contact 2 grounding connection 3 Status LED (high voltage) 4 Status LED (fault signal) � � � �

Fault signal connection and external control

NPN transistor output, U = max. 27 V DC, I = max. 20 mA The pin assignment is shown in Fig. 4. In case of a short circuit of the remote contact and GND the high voltage supply is switched off. Fig. 4: Pin assignment Z-116822y � � � � � �������������������� ������������������� ������� ������� ����� � � � � � � � ������ �����

The RX22 ion blower unit STATICJET must be operated only with a

24 VDC line voltage. 4.1 Startup Caution! Before starting up the ion blower unit the user must make sure that the unit has been installed and assembled correctly. Then first activate the air and then the supply voltage. 4.2 Function monitoring The LEDs in the connection zone signal the proper function of the unit. • If neither of the two LEDs lights up, the supply voltage is switched off or both LEDs are defective. • If a fault has occurred (e.g. high-voltage sparking, short circuit), the high voltage will be cut off: - the green LED goes off and the red LED will come on, - a fault signal will be sent (open collector) - the discharging effect is interrupted. Note! Faults will not be saved. A disruption of the supply voltage automatically results in the fault message being acknowledged. Green LED Red LED Operations status of the output voltage Error status LED ein High voltage is ON. Internal error LED aus High voltage is OFF. No error

Electric shock hazard!

• Disconnect the supply voltage before carrying out any maintenance or repair work. • The machine in which the RX22 ion blower unit STATICJET is installed must not be in operation. • Maintenance work must be carried out by qualified electricians. Caution! The internal emission tip of the RX22 ion blower unit STATICJET must not be damaged. For trouble-free operation, the tip must be straight and sharply pointed. Defective emission tips must be replaced using the proper tools. RX22 Ion Blower Unit STATICJET Dismantle the nozzle attachment to clean the emission tip. • Clean the emission tips at regular intervals using a soft nylon brush or a clean cloth. • For tough dirt (e.g. grease, ink, adhesive etc.), clean the emission tip and the air outlet vent with a suitable solvent (cleaning gasoline). • Caution! Do not immerse the RX22 ion blower unit STATICJET in solvent. Fig. 5: Emission tip and air outlet Z-116819y_2 1 emission tip 2 air outlet holes of the nozzle � �

Risk of deflagration!

Allow the solvent to evaporate completely before restarting the RX22 ion blower unit STATICJET. • Recommended cleaning intervals:after 100 - 200 hours. • Always make sure that the unit is probperly grounded.

Electric shock hazard!

• Disconnect the supply voltage before carrying out any maintenance or repair work. • Maintenance work must be carried out by qualified electricians. Failure Cause Measure No LED lights up No supply voltage Check supply voltage and connections. Inform Eltex Service. Red LED lights up Internal error To acknowledge the fault, switch the supply voltage off and back on. If the fault persists, notify Eltex Ser- vice.

The units are warranted for a period of 12 months provided that the opera-

ting conditions have been maintained, that the units have not been tam- pered with and that the units show no mechanical damage. The warranty applies only if the operating and assembly instructions spe- cified by Eltex have been observed. The warranty period begins on the date of delivery. In the event of defects occurring during the warranty period, the units or defective components will be repaired at Eltex. Defective components will be replaced and installed free of charge. If repairs are required at the customer's premises, the costs for sending a technician (travel, travel time, expenses) will be charged to the customer.

Technical specifications RX22 STATICJET

Supply voltage Power input Output voltage Ambient operating temperature Storage temperature Ambient humidity Optical indicator Fault signal contact Air supply Air temperature Mains power Ground link Enclosure Emission tip Protection class Dimensions Weight 24 V DC +/- 10 % 2.4 VA max. 6 kV AC +/- 250 V / 33 kHz 0 °C...+40°C (+32°F...+104°F) 0 °C...+50°C (+32°F...+122°F) max. 80% r.h., non-dewing LED on enclosure: green: high voltage active red: malfunction NPN - open collector, U = max. 40 V DC, I = max. 20 mA Da 8 mm (outside tolerated hose) max. 0.2 MPa, dry, oil-free, filtered compressed air or nitrogen 0...+40°C (+32...+104°F) non-dewing, always avoid rapid changes in temperature socket contact with plug, power supply as accessory available internal M4 thread on both sides of the enclosure, max. screw-in depth 5 mm stainless steel, polyamide titanium alloy IP20, according to EN 60529 54 x 73 x 31 mm (H x W x D) without nozzle and air hose (see Fig. 6) approx. 175 g without power supply

Noise emission (dBA)

* PSA - personal protective equipment / hearing protection Inlet air pressure for all nozzles typical values [MPa] 0.05 0.1 0.2 [m³/h] 5 7,5 12 [MPa] 0.05 0.1 0.2 RX22/S 80 85 92 PSA* must be provided RX22/P 77 83 88 PSA* must be provided RX22/F 64 68 72

ion blower unit

STATICJET Z-116818y �������� �� �� �� �� �� �� �� �� ���

10. Spare parts and accessories

Please specify the article number when ordering. Article Article No. Power supply for RX22 ion blower unit STATICJET 113677 Circular nozzle 116782 Fishtail nozzle 102954 Emission tip RX22 113261 Bit insert for tip changes 113262 Tube, flexible L=300 mm 113065 Plug-type connector G 1/4", DN10 113019 Combination plug, strip 5-pin 116776 Operating Instructions (specify language) BA-xx-2083

79576 Weil am Rhein | Germany

Phone +49 (0) 7621 7905-422 eMail [email protected] Internet www.eltex.de Eltex offices and agencies The addresses of all Eltex agencies can be found on our website at www.eltex.de Z01007y